• Title/Summary/Keyword: ESR1

Search Result 435, Processing Time 0.021 seconds

Relative Anticipated Erythrocyte Sedimentation Rate of Cattle Blood, as Measured by 45 Degree-Angled Capillary Hematocrit Tube, for Ambient Temperature and PCV Value (소 혈액의 45도 경사 모세관에 의한 ESR측정에 있어서 환경온도 및 PCV에 상관하는 관계적 예기ESR치)

  • Lee, Bang-whan
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.339-345
    • /
    • 1987
  • Each of twenty blood samples taken from apparently healthy Korean Cows was used to produce five different mixtures of autologous plasma and blood corpuscles such that their values of packed cell volume (PCV) lay between 10 to 50ml/l00ml. The measurements of erythrocyte sedimentation rate (ESR) using 45 degree-angled capillary hematocrit tube, 1.1-1.2mm bore, ($45^{\circ}-micro-ESR$) were practised for the blood of various levels of PCV under the ambient temperature of ${10^{\circ}C}$, ${20^{\circ}C}$ and ${30^{\circ}C}$. Correlation of ESR to ambient temperature showed linear regression each in five levels of PCV. ESR increased with ascending ambient temperature, and magnitude of the increase of ESR became greater as the level of PCV lowered. Correlation of ESR, of which values were transformed by the linear regression equation correlated to ambient temperature to PCV showed curvilinear regression each in three levels of ambient temperature, and ESR was increased with decreasing PCV. The data were statistically analysed and a list of relative anticipate $45^{\circ}-micro-ESR$ values for PCV and ambient temperature was presented.

  • PDF

Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$ ($SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가)

  • Lee, Jung-Ee;Kim, Kyung-Dong;Lee, Chae-Hoon;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.110-115
    • /
    • 1996
  • The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using $SEDIsystem^{TM}$ automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between $SEDIsystem^{TM}$ and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), $SEDIsystem^{TM}$ and Wintrobe y = 1.14x - 14.7 (r=0.789), respectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, $SEDIsystem^{TM}$ automated ESR measurement correlated with modified Westergren and Wintrobe methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that $SEDIsystem^{TM}$ automated ESR measurement may be useful tool for clinical practice.

  • PDF

Detection of Gamma-Irradiated Dried Vegetable Using ESR Spectroscopy (감마선 조사 건조채소의 ESR 검지)

  • Han, Jeong-Eun;Yang, Jae-Seung
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.345-348
    • /
    • 2004
  • Dried cabbage, spinach, carrot, mugwort and yam were irradiated at 1, 5 and 10 kGy using a $^{60}Co$ irradiator at room temperature. Effects of irradiation dose and storage time on irradiated dried vegetables were investigated through electron spin resonance (ESR) spectroscopy. Strong positive correlation coefficients ($R^{2}=0.9698-0.9915$) were obtained between irradiation dose and corresponding ESR signal intensity. ESR signal of mugwort was most stable at 9 weeks storage, followed by carrot, yam, and spinach, whereas that ESR signal of cabbage was not distinguishable.

Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat (경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Shin, Sung-shik;Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

Identification of Irradiated Crabs by ESR Spectrometry

  • Nam, Hye-Seon;Ly, Sun-Yung;Yang, Jae-Seung
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.1
    • /
    • pp.1-4
    • /
    • 2000
  • Electron spin resonance (ESR) spectroscopy was used to investigate the effect of irradiation dose on the ESR signal intensity of irradiated crabs and the stability of these radicals under 9 weeks of storage. Swimming and small crabs were irradiated with doses of 0, 1, 3, 5 and 7 kGy using a Co-60 irradiator at ambient temperature. A claw, a walking leg and a cars- pace of the crab pieced and dried were placed in a resonant quart tube within an EPR X-band spectrometer. The irradiated crabs presented an asymmetric absorption in shape at g$_1$=2.002 $\pm$ 0.003 and g$_2$=1.998$\pm$0.005, and were different from the non-irradiated ones. The intensity of the ESR signals was greatest in the claw, intermediate in the carapace and lowest in the walking leg. Samples given low and high doses of irradiation could also be distinguished. The ESR signal after irradiation was stable, even after a 9-week storage.

  • PDF

Detection Characteristics of Irradiated Aloe vera by the Analysis of PSL, TL and ESR (감마선 조사된 알로에 베라의 PSL, TL 및 ESR 검지 특성)

  • Kim Byeong-Keun;Lim Sang-Yong;Song Hyun-Pa;Yun Hye-Jeong;Kwon Joong-Ho;Kim Dong-Ho
    • Food Science and Preservation
    • /
    • v.13 no.1
    • /
    • pp.61-65
    • /
    • 2006
  • Photostimulated luminescence (PSL), thermoluminescence(TL) and electron spin resonance (ESR) analyses were conducted to detect irradiation treatment of aloe vera powder, which was gamma-irradiated at 1, 3, 5 and 7 kGy. The non-irradiated aloe vera powder indicated below 700 of photon count in PSL, whereas, irradiated at 1 kGy and more, it showed more than 5,000 photon counts, indicating that it is feasible to detect the irradiation of aloe vera powder through PSL In the result of TL, from the minerals of the samples that were irradiated at more than 1 kGy, TL glow curve was able to be seen at around $150^{\circ}C$. As the quantity of irradiation goes up, the ratio of $TL_1\;and\;TL_2$ also increased in proportion to that of irradiation. In the result of ESR analysis, unspecific centeral ESR signal was could be seen. As the amount of irradiation on the samples increased to the level of $R^2=0.97$, the signal intensity also rose similarly. In conclusion, the PSL, TL and ESR exhibited the typical signals induced by irradiation treatment and were able to successfully detect all of the irradiated aloe vera powder. In addition, we found a positive correlation between the intensity of ESR and TL signals and irradiation doses.

Detection of Gamma-Irradiated Korean Medicinal Herbs by ESR Spectroscopy (ESR Spectroscopy에 의한 감마선 조사된 한약재의 검지)

  • Lee, Eun-Jeong;Yang, Jae-Seung
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.717-721
    • /
    • 2002
  • Study was carried out with electron spin resonance (ESR) spectroscopy to identify irradiated Korean medicinal herbs. Pueraria thunbergiana Benth., Angelica gigas Nakai, Agaricus blazei Murill and Astragalus membranaceus Bunge were irradiated with doses of 0, 1, 5 and 10 kGy at room temperature using a Co-60 irradiator. The irradiated Korean medicinal herbs exhibited an asymmetric absorption, which was different from the non-irradiated ones. The strength of ESR signals linearly increased by dose-dependent manner (1~10 kGy) and highly positive correlation coefficients ($R^2$=0.9428~0.9942) were obtained between the irradiation doses and the corresponding ESR signal intensities. Detection of the irradiated Korean medicinal herbs was possible even after 6 weeks of storage although the signal intensities of the irradiated samples decreased until 2 weeks at room temperature.

Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate (ESR) of blood diluted with isotonic dextrose solution in cattle (소에 있어서 등장 dextrose액으로 희석한 혈액의 적혈구 침강율(ESR) 측정에 의한 적혈구 침층용적(VPRC)치의 간접계산법)

  • Lee, Bang-whan;Bahk, Young-woo;Min, Byeong-man
    • Korean Journal of Veterinary Research
    • /
    • v.30 no.1
    • /
    • pp.107-112
    • /
    • 1990
  • The purpose of this study is to derive indirect values of volume of packed red cell(VPRC), without centrifugation, from erythrocyte sedimentation rate(ESR) of blood diluted with isotonic dextrose solution in cattle. Each of ten blood samples taken from apprently healthy Korean cows and Holstein cows was used to produce eight different mixture of autologous plasma and blood corpuscles such that their values of VPRC lay between 15 to 50ml/100ml, and then each of the blood mixture was again diluted with 5% dextrose solution. The measurements of ESR using 45 degree-angled capillary hematocrit tube, 1.1~1.2mm bore, ($45^{\circ}$-micro-ESR) were practised for the diluted blood of various levels of VPRC under the ambient temperature of $10^{\circ}$, $20^{\circ}$ and $30^{\circ}C$. Reliable values of VPRC on the basis of the correlating linear regressive equation to the ESR could be derived from the values of $45^{\circ}$-micro-ESR/hr in the mixture of one part of whole blood and one part of 5% dextrose solution(1:1). For an aid of practical use, authors suggested a list of the $45^{\circ}$-micro-ESR/hr values of the diluted blood equivalent to VPRC of whole blood.

  • PDF

Genetic Variations of ESR1 Gene are Associated with Bone Mineral Density Traits in Korean Women

  • Jin, Hyun-Seok;Eom, Yong-Bin
    • Biomedical Science Letters
    • /
    • v.18 no.3
    • /
    • pp.244-253
    • /
    • 2012
  • Bone mineral density (BMD) is used in the clinical diagnosis of osteoporosis and the assessment of fracture risk. Osteoporosis, characterized mainly by decreased BMD, is a highly heritable complex disorder and a major public health concern to hundreds of millions of elderly persons worldwide. However, the specific genetic variants determining risk for low bone density are still largely unknown. Here, we performed association analysis to elucidate the possible relations of genetic polymorphisms in ESR1 gene with low bone density. By examining genotype data of a total of 1813 women in the Korean Association REsource (KARE) study, we discovered the ESR1 gene polymorphisms are associated with decreased BMD and osteoporosis. The results on the BD-RT (bone density estimated by T-score at distal radius), three SNPs (rs2248586, rs9371557, and rs1569788) within the ESR1 gene were significantly associated with bone density. The results on the BD-TT (bone density estimated by T-score at midshaft tibia), five SNPs (rs9371552, rs2248586, rs712221, rs7772475, and rs3798577) were significantly associated with bone density. The SNP rs2248586 within the ESR1 gene had commonly significance in both BD-RT (${\beta}$=-0.151, dominant P=0.049) and BD-TT (${\beta}$=-0.156, dominant P=0.039). In the SNP rs2248586, their ${\beta}$-values in BD-RT and/or BD-TT showed consistent trends with the odds ratios (ORs) of osteoporosis. In summary, we found statistically significant SNPs in ESR1 gene that are associated with both decreased BMD and osteoporosis traits. Therefore, our findings suggest ESR1 gene could be related to pathogenesis of osteoporosis.

Erythrocyte Sedimentation Rate and C-reactive Protein Values in Patients with Hip Arthroplasty (인공고관절 치환술 전후의 CRP 및 ESR의 변화)

  • Kim, Se-Dong;Lee, Dong-Chul;Park, Dong-Gu
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.2
    • /
    • pp.218-223
    • /
    • 1992
  • Serum C-reactive protein(CRP) levels and erythrocyte sedimentation rates(ESR) were measured in 46 patients treated with uncomplicated primary hip replacements, 39 total tip replacements and 7 bipolar hip replacements. In uncomplicated primary hip replacements, ESR levels were slightly elevated preoperatively and were variable postoperatively. But CRP was normal before surgery and elevated in postoperative course, but back to normal within three weeks in most cases. Early success of hip arthroplasty is indicated by normalization of CRP within three weeks, regardless of ESR. Since ESR seems to react somewhat differently from the CRP, both methods are useful in the monitoring of complications after hip arthroplasty.

  • PDF