• 제목/요약/키워드: ESR estimation

검색결과 15건 처리시간 0.023초

Estimation of ESR in the DC-Link Capacitors of AC Motor Drive Systems with a Front-End Diode Rectifier

  • Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.411-418
    • /
    • 2015
  • In this paper, a new method for the online estimation of equivalent series resistances (ESR) of the DC-link capacitors in induction machine (IM) drive systems with a front-end diode rectifier is proposed, where the ESR estimation is conducted during the regenerative operating mode of the induction machine. In the first place, a regulated AC current component is injected into the q-axis current component of the induction machine, which induces the current and voltage ripple components in the DC-link. By processing these AC signals through digital filters, the ESR can be estimated by a recursive least squares (RLS) algorithm. To acquire the AC voltage across the ESR, the DC-link voltage needs to be measured at a double sampling frequency. In addition, the ESR current is simply reconstructed from the stator currents and switching states of the inverter. Experimental results have shown that the estimation error of the ESR is about 1.2%, which is quite acceptable for condition monitoring of the capacitor.

PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단 (An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters)

  • 손진근;나채동
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

직류 링크 전해 커패시터의 수명 추정 (Life Estimation of DC Link Electroytic Capacitors)

  • 이동춘
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.57-60
    • /
    • 2000
  • An aluminum electrolytic capacitor is used in DC Link of ac motor drive system. In this case it usually has the shortest lifetime in the system and then determines the system lifetime. Therefore life estimation of the electrolytic capacitor is needed for maintenance of th circuit. In this paper a method for life estimation is presented with a ESR(equivalent series resistance) model and a heat transfer model of capacitor that can be used to estimate operating temperature it is investigated through a simple example using ESR and heat transfer.

  • PDF

DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법 (A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter)

  • 손진근;김진식
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

ESR Spectroscopy에 의한 전자선 조사 건조 채소의 검지와 흡수선량 예측 (Detection and Absorbed-Dose Estimation of Electron Beam-Irradiated Dried Vegetable Using ESR Spectroscopy)

  • 권중호;정형욱
    • 한국식품영양과학회지
    • /
    • 제28권4호
    • /
    • pp.882-885
    • /
    • 1999
  • Along with the increasing demands for food irradiation technology, proper detection methods for controlling irradiated foods are required. Dried vegetable(chunggyungchae), which is permitted to be irradiated in Korea, was subjected to a detection study by ESR spectroscopy. Pre established threshold value was successfully applicable to the detection of 50 coded unknown samples of dried clean vege tables, both nonirradiated and electron beam irradiated. Three calibration curves obtained from the samples irradiated at 2.5~15 kGy were not practically adopted to estimate actual absorbed doses ranging from 4 to 7 kGy.

  • PDF

DC 전해 커패시터의 고장진단 기준모델 입력을 위한 외부변수의 특성 고찰 (Characteristic Investigation of External Parameters for Fault Diagnosis Reference Model Input of DC Electrolytic Capacitor)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.186-191
    • /
    • 2012
  • DC Bus Electrolytic capacitors have been widely used in power conversion system because they can achieve high capacitance and voltage ratings with volumetric efficiency and low cost. This type of capacitors have been traditionally used for filtering, voltage smoothing, by-pass and other many applications in power conversion circuits requiring a cost effective and volumetric efficiency components. Unfortunately, electrolytic capacitors are some of the weakest components in power electronic converter. Many papers have proposed different methods or algorithms to determinate the ESR and/or capacitance C for fault diagnosis of the electrolytic capacitor. However, both ESR and C vary with frequency and temperature. Accurate knowledge of both values at the capacitors operating conditions is essential to achieve the best reference data of fault judgement. According to parameter analysis, the capacitance increases with temperature and the ESR decreases. Higher frequencies make the ESR and C to decrease. Analysis results show that the proposed electrolytic capacitor parameter estimation technique can be applied to reference signal of capacitor diagnosis systems successfully.

Menopausal Status Modifies Breast Cancer Risk Associated with ESR1 PvuII and XbaI Polymorphisms in Asian Women: a HuGE Review and Meta-analysis

  • Li, Li-Wen;Xu, Lei
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제13권10호
    • /
    • pp.5105-5111
    • /
    • 2012
  • Background: Published data on the association between single nucleotide polymorphisms (SNPs) in the ESR1 gene and breast cancer susceptibility are inconclusive or controversial. The aim of this Human Genome Epidemiology (HuGE) review and meta-analysis was to derive a more precise estimation of this relationship. Methods: A literature search of Pubmed, Embase, Web of science and CBM databases was conducted from inception through September 1th, 2012. Crude odds ratios (ORs) with 95% confidence intervals (CIs) were used to assess the strength of association. Results: A total of five studies including 1,678 breast cancer cases and 1,678 general population controls in Asian populations were involved in this meta-analysis. When all the eligible studies were pooled into the meta-analysis, the higher transcriptional activity variant allele T of ESR1 PvuII (C>T) (rs2234693) in pre-menopausal breast cancer women showed a significant relation to increased risk (OR = 1.13, 95%CI: 1.01-1.28, P = 0.040) in contrast to their post-menopausal counterparts which showed non-significant increased risk (OR = 1.01, 95%CI: 0.87-1.18, P = 0.858). Nevertheless, no significant association between ESR1 XbaI (A>G) (rs9340799) polymorphism and the risk of breast cancer was observed in pre-menopausal and post-menopausal individuals. Conclusion: Based on a homogeneous Asian population, results from the current meta-analysis indicates that the ESR1 PvuII (C>T) polymorphism places pre-menopausal breast cancer women at risk for breast cancer, while ESR1 XbaI (A>G) polymorphism is not likely to predict the risk of breast cancer.

두경부 감염 환자에서 혈청 내 C-Reactive Protein의 변화 (THE CHANGES OF SERUM C-REACTIVE PROTEIN IN THE HEAD AND NECK INFECTION)

  • 이주현;김진수;이상한;김철환
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제29권1호
    • /
    • pp.5-13
    • /
    • 2003
  • 본 연구의 목적은 두경부 감염 환자에서 적혈구침강속도(ESR), 백혈구와 비교해 혈장 내 C-Reactive Protein(CRP)이 가지는 진단과 경과관찰에서의 기여도를 아는 데 있다. 본 연구를 위해 31명의 감염환자를 실험군으로, 32명의 악교정 수술 환자를 대조군으로 설정하여 다음과 같은 결과를 얻었다. 1. 실험군에서의 C-Reactive Protein(CRP)은 대조군의 CRP에 비해 더 높은 수치를 나타내며 감염이 지속되었던 증례를 제외하고는 지속적으로 감소하는 경향을 나타내었다(P<0.001). 2. ESR은 실험군과 대조군에서 모두 일정한 경향이 없었다. 3. 각 변수간의 상관관계는 CRP와 백혈구가 상관계수 0.664로 가장 높은 양의 상관관계를 나타내었다(r=0.664, P<0.01). 4. 설정된 ROC curve에서 분류기준값(cut-off value)의 변화에 따라 CRP 곡선의 증가가 빠르게 나타나고 측정된 곡선의 아래 면적(AUC: Area Under the Curve)이 0.744로 높은 값을 나타내어 예측의 정확도가 높다고 판단된다. 5. 실험군에서 회복일(recovery day)에 각 변수의 민감도는 CRP가 83%, ESR이 17%, 백혈구가 71%로 나타났다. 이상의 연구로 미루어 볼 때, 두경부 영역에서 CRP는 감염을 진단하고 경과관찰을 하는데 있어 ESR이나 Leukocyte에 비해 더 민감하게 환자를 감시(monitoring)할 수 있는 유용한 검사라고 사료된다.

인버터용 전해커페시터의 수명 추정 (Life Estimation of Electrolytic Capacitors in Inverters)

  • 이동춘
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.243-245
    • /
    • 2000
  • In general, aluminum electrolytic capacitors are used in the DC link of PWM inverters fur ac motor drives. The capacitor usually has the shortest lifetime in the system and then determines the lifetime of the inverter system. In this paper, a method of capacitor lifetime estimation is proposed by using an ESR(equivalent series resistance) model and a heat transfer model of capacitor, from which internal operating temperature is estimated. Then, the lifetime is predicted by Arrhenius's equation. A practical example is presented.

  • PDF

단상 하프-브리지 부스트 컨버터에서 DC 전해 커패시터의 고장예측 모니터링 (Failure Prediction Monitoring of DC Electrolytic Capacitors in Half-bridge Boost Converter)

  • 서장수;손진근;전희종
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.345-350
    • /
    • 2014
  • DC electrolytic capacitor is widely used in the power converter including PWM inverter, switching power supply and PFC Boost converter system because of its large capacitance, small size and low cost. In this paper, basic characteristics of DC electrolytic capacitor vs. frequency is presented and the real-time estimation scheme of ESR and capacitance based on the bandpass filtering is adopted to the single phase boost converter of uninterruptible power supply to diagnose its split dc-link capacitors. The feasibility of this real-time failure prediction monitoring system is verified by the computer simulation of the 5[kW] singe phase PFC half-bridge boost converter.