• Title/Summary/Keyword: ESR

검색결과 678건 처리시간 0.024초

Uncertainty Minimization in Quantitative Electron Spin Resonance Measurement: Considerations on Sampling Geometry and Signal Processing

  • Park, Sangeon;Shim, Jeong Hyun;Kim, Kiwoong;Jeong, Keunhong;Song, Nam Woong
    • 한국자기공명학회논문지
    • /
    • 제24권2호
    • /
    • pp.53-58
    • /
    • 2020
  • Free radicals including reactive oxygen species (ROS) are important chemicals in the research area of biology, pharmaceutical, medical, and environmental science as well as human health risk assessment as they are highly involved in diverse metabolism and toxicity mechanisms through chemical reactions with various components of living bodies. Electron spin resonance (ESR) spectroscopy is a powerful tool for detecting and quantifying those radicals in biological environments. In this work we observed the ESR signal of 2,2,6,6-Tetra-methyl piperidine 1-oxyl (TEMPO) in aqueous solution at various concentrations to estimate the uncertainty factors arising from the experimental conditions and signal treatment methods. As the sample position highly influences the signal intensity, dual ESR tube geometry (consists of a detachable sample tube and a position fixed external tube) was adopted. This type of measurement geometry allowed to get the relative uncertainty of signal intensity lower than 1% when triple measurements are averaged. Linear dependence of signal intensity on the TEMPO concentration, which is required for the quantification of unknown sample, could be obtained over a concentration range of ~103 by optimizing the signal treatment method depending on the concentration range.

Effects of electroslag remelting process and Y on the inclusions and mechanical properties of the CLAM steel

  • Qiu, Guoxing;Zhan, Dongping;Li, Changsheng;Yang, Yongkun;Jiang, Zhouhua;Zhang, Huishu
    • Nuclear Engineering and Technology
    • /
    • 제52권4호
    • /
    • pp.811-818
    • /
    • 2020
  • Y-containing CLAM steels were melted via vacuum induction melting and electroslag remelting. In this study, the evolution, microstructure, and mechanical properties of the alloy inclusions (ESR-1 (0 wt.% Y), ESR-2 (0.016 wt.% Y) and ESR-3 (0.042 wt.% Y)) were investigated. Further, the number of inclusions in ESRed steel was observed to obviously decrease, and the distributions were more uniform. The fine Y-Al-O inclusions (1-2 ㎛) were the main inclusions in ESR-2. The addition of Y affected the prior austenite grain size (PAGZ), increasing the tensile strength at test temperature. Low ductile-brittle transition temperature (DBTT) was obtained because of the fine PAGZ and dispersive inclusions. For the ESRed CLAM steel with 0.016 wt.% Y, the yield strengths were 621 MPa at 20 ℃ and 354 MPa at 600 ℃ in air. Further, the uniform elongation and elongation of the ESR-2 alloy were 5.5% and 20.1% at 20 ℃, respectively. Meanwhile, the DBTT tested using full-size Charpy impact specimen (55 cm × 10 cm × 10 cm) was reduced to -83 ℃.

In vivo ESR measurement of free radical reaction in living mice

  • Han, Jin-Yi;Hideo Utsumi
    • 한국응용약물학회:학술대회논문집
    • /
    • 한국응용약물학회 2000년도 춘계학술대회
    • /
    • pp.6-7
    • /
    • 2000
  • Recently, free radicals such as active oxygen species, nitric oxide, etc are believed to be one of the key substances in physiological and pathological, toxicological phenomena, and oxidative damages, and all organism have defencing system against such as free radicals. Formation and extinction of free radicals may be regulated through bio-redox system, in which various enzymes and compounds should be involved in very complicated manner. Thus, direct and non-invasive measurement of in vivo free radical reactions with living animals must be essential to understand the role of free radicals in pathophysiological phenomena. Electron spin resonance spectroscopy (ESR) is very selective and sensitive technique to detect free radicals, but a conventional ESR spectrometer has large detect in application to living animals, since high frequent microwave is absorbed with water, resulting in generation of high fever in living body. In order to estimate in vivo free radical reactions in living whole animals, we develop in vivo ESR-CT technique using nitroxide radicals as spin probes. Nitroxide radicals and their reduced forms, hydroxylamines, are known to interact with various redox systems. We found that! ! the signal decay due to reduction of nitroxyl radicals is influenced by aging, inspired oxygen concentration, ischemia-referfusion injury, radiation, etc. In the present paper, I will introduce in vivo ESR technique and my laboratory recent results concerning non-invasive evaluation of free radical reactions in living mice.

  • PDF

용액에서의 아미노산 및 단백질 자유기에 관한 ESR 연구 제3보 $Ti-H_2O_2$ Flow System으로 만든 Lysozyme 자유기의 ESR 연구 (An ESR Study of Amino Acid and Protein Free Radicals in Solution Part Ⅲ. ESR Study of Lysozyme Free Radical Produced by $Ti-H_2O_2$ Flow System)

  • 홍순주
    • 대한화학회지
    • /
    • 제15권4호
    • /
    • pp.177-181
    • /
    • 1971
  • Free radicals of lysozyme produced by $Ti-H_2O_2$ system were studied in aqueous solution at room temperature using ESR with a continuous flow-mixing. The spectra, each consisting of a doublet with 5.5 G splitting and a broad resonance covering 80 G splitting are closely similar in shape to that for solid irradiated in vacuum at $77^{\circ}K$ and observed at room temperature immediately on warming. The result is assumed to indicate that the secondary protein radical components formed within 0.01 second, dead time of the mixing chamber, and initiated by hydrogen atom abstraction at ${\alpha}$-carbon atom of peptide chain in liquid solution at room temperature are identical to those resulting from the initial formation of a mixture of positive holes and negative ions by ionization processes as well as radical fragments by the rupture of chemical bonds in the solid during similar time at the same temperature. A broad resonance is observed with considerable amplitude on the high field side of the doublet, which is quite dissimilar to the spectra of irradiated solid lysozyme. This resonance was tentatively attributed to the polypeptide free radical in which unpaired electrons are localized on side chain.

  • PDF

자외선 조사에 따른 게르마늄 함유 다성분계 산화물 유리의 광흑화와 열표백화 현상 (Photodarkening and Thermal Bleaching Effect in Ge-doped Multicomponent Oxide Glasses by UV Irradiation)

  • 이회관;오영석;강원호
    • 한국산학기술학회논문지
    • /
    • 제3권3호
    • /
    • pp.161-165
    • /
    • 2002
  • 게르마늄첨가 다성분계 산화물 유리를 제조하여 자외선(UV) 조사에 따른 유리의 미세 구조변화를 PL(photo-luminescence)과 ESR(electron spin resonance)을 이용하여 관찰하였다. 게르마늄 첨가량이 증가함에 따라 PL방사량은 증가하였으며, UV 조사 후에는 처음과 반대되는 광혹화 현상으로 감소하는 현상을 나타냈다. UV조사로 변화된 특성은 열처리를 통하여 회복이 가능하였으며, ESR 측정에서도 PL결과와 같은 광혹화 현상(phodarkenine effect)과 열표백화 현상(thermal bleaching effect)이 확인되었다. 또한, XRD 분석을 통하여 이러한 현상이 비정질 상은 그대로 유지하는 미세구조 변화임을 알 수 있었다.

  • PDF

DC 전해 커패시터의 고장진단 기준모델 입력을 위한 외부변수의 특성 고찰 (Characteristic Investigation of External Parameters for Fault Diagnosis Reference Model Input of DC Electrolytic Capacitor)

  • 박종찬;손진근
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.186-191
    • /
    • 2012
  • DC Bus Electrolytic capacitors have been widely used in power conversion system because they can achieve high capacitance and voltage ratings with volumetric efficiency and low cost. This type of capacitors have been traditionally used for filtering, voltage smoothing, by-pass and other many applications in power conversion circuits requiring a cost effective and volumetric efficiency components. Unfortunately, electrolytic capacitors are some of the weakest components in power electronic converter. Many papers have proposed different methods or algorithms to determinate the ESR and/or capacitance C for fault diagnosis of the electrolytic capacitor. However, both ESR and C vary with frequency and temperature. Accurate knowledge of both values at the capacitors operating conditions is essential to achieve the best reference data of fault judgement. According to parameter analysis, the capacitance increases with temperature and the ESR decreases. Higher frequencies make the ESR and C to decrease. Analysis results show that the proposed electrolytic capacitor parameter estimation technique can be applied to reference signal of capacitor diagnosis systems successfully.

커패시터의 ESR을 고려한 Quasi Z-소스 인버터의 임피던스 네트워크 설계 (Designing Impedance Network at Quasi Z-Source Inverters by Considering ESR in the Capacitor)

  • 양종호;전태원;이홍희;김흥근;노의철
    • 전력전자학회논문지
    • /
    • 제17권5호
    • /
    • pp.453-460
    • /
    • 2012
  • This paper proposes the method to design the parameters of an impedance network at three-phase QZSI(quasi Z-source inverter) by considering an equivalent series resistance (ESR) in the capacitor. The equations of both two capacitor voltages and two inductor currents are derived at three operating modes of the QZSI. The capacitor voltage ripples caused by the ESR in the capacitor at the transition state of operating modes are calculated. Based on the ripples of both the capacitor voltages and inductor currents, the optimal values of capacitor and inductor are designed. The simulation studies using PSIM and experimental results with DSP are carried out to verify the performance of design method.

전력변환장치에서의 DC 출력 필터 커패시터의 온라인 고장 검출기법 (On-line Failure Detection Method of DC Output Filter Capacitor in Power Converters)

  • 손진근
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.483-489
    • /
    • 2009
  • Electrolytic capacitors are used in variety of equipments as smoothening element of the power converters because it has high capacitance for its size and low price. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. This objective of this paper is to propose a new method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC output filter of power converter. The ESR of electrolytic capacitor estimated from RMS result of filtered waveform(BPF) of the ripple capacitor voltage/current. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity. Simulation and experimental results are shown to verify the performance of the proposed on-line method.

AIM 및 ESR 법에 의해 제조한 Fe-29Ni-17Co 합금의 조직 및 성질 (Structure and Properties of Fe-29Ni-17Co Alloy Manufactured by Air Induction Melting and Electro-Slag Remelting)

  • 이정근;김문현;주대헌;김명호
    • 한국주조공학회지
    • /
    • 제22권4호
    • /
    • pp.160-166
    • /
    • 2002
  • The structure and properties of Fe-29Ni-17Co alloy which had been melted using induction furnace in air atmosphere and than electroslag-remelted were investigated. The oxygen content was reduced to 0.03% when the ingot was refined from $0.09{\sim}0.12%$ of that air melted. The amounts of spheroidal oxides inclusions and gas porosities of ingot were markedly reduced by the ESR process. CTE of ESR ingot contained small amount of oxides and porosities was found to be lower than that of AIM ingot, and tensile properties of ESR ingot and plate were found to be superior than that of AIM ingot and plate.

인버터 직류링크 전압 평활용 전해 커패시터의 고장 진단 (Fault Diagnosis of a Electrolytic Capacitor for Inverter DC-Link Voltage Smoothing)

  • 이광운
    • 전력전자학회논문지
    • /
    • 제12권5호
    • /
    • pp.372-377
    • /
    • 2007
  • 본 논문은 가변속 구동 장치에서 직류링크 전압 평활용으로 사용되는 전해 커패시터의 새로운 고장 진단 방법을 제안한다. 전해 커패시터의 등가직렬저항은 직류링크 전압과 부하 전류로부터 직접 추정되고, 추정된 등가직렬저항으로부터 전해 커패시터의 상태가 결정된다. 온도 변동에 따른 등가직렬저항 변동을 보상하기 위해, 커패시터 주변의 PCB에 다이오드를 부착하고 다이오드의 전압 강하로부터 커패시터의 온도를 간접적으로 검출한다. 시뮬레이션 및 실험은 제안된 방식의 효용성을 보인다.