• 제목/요약/키워드: ESR

검색결과 678건 처리시간 0.028초

Association between ESR1 rs1884051 polymorphism and dietary total energy and plant protein intake on obesity in Korean men

  • Doo, Mi-Ae;Kim, Yang-Ha
    • Nutrition Research and Practice
    • /
    • 제5권6호
    • /
    • pp.527-532
    • /
    • 2011
  • ESR1 has been listed in the Human Obesity Gene Map as candidate gene associated with obesity. Thus, in this study, we investigated the effect of the ESR1 rs1884051 polymorphism on obesity-related variables, together with their modulations by dietary intake in Korean men. The obesity-related variables and dietary intake of 3,039 Korean men aged 40-59 years from KoGES database were analyzed. Body weight (P = 0.007), BMI (P = 0.003), waist-hip ratio (= 0.011), fat body mass (P = 0.010), and body fat percentage (P = 0.040) were significantly lower in subjects with the minor T allele of ESR1 rs1884051 than in subjects carrying the C allele. Moreover, the rs1884051 T allele was associated with a decreased risk of obesity prevalence (P = 0.040). Among the subjects whose total energy intake was below the median, carrier of the minor T allele of ESR1 rs1884051 had a lower BMI (P = 0.003) when compared with subjects carrying the C allele. In addition, among subjects whose plant protein intake was above the median, carrier of the minor T allele of ESR1 rs1884051 had a lower BMI (P = 0.044) compared with subjects carrying the C allele. Our findings demonstrate that there is a significant association between the ESR1 rs1884051 variant and obesity-related variables and this association can be potentially modified by dietary energy and plant protein intake.

Estimation of ESR in the DC-Link Capacitors of AC Motor Drive Systems with a Front-End Diode Rectifier

  • Nguyen, Thanh Hai;Le, Quoc Anh;Lee, Dong-Choon
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.411-418
    • /
    • 2015
  • In this paper, a new method for the online estimation of equivalent series resistances (ESR) of the DC-link capacitors in induction machine (IM) drive systems with a front-end diode rectifier is proposed, where the ESR estimation is conducted during the regenerative operating mode of the induction machine. In the first place, a regulated AC current component is injected into the q-axis current component of the induction machine, which induces the current and voltage ripple components in the DC-link. By processing these AC signals through digital filters, the ESR can be estimated by a recursive least squares (RLS) algorithm. To acquire the AC voltage across the ESR, the DC-link voltage needs to be measured at a double sampling frequency. In addition, the ESR current is simply reconstructed from the stator currents and switching states of the inverter. Experimental results have shown that the estimation error of the ESR is about 1.2%, which is quite acceptable for condition monitoring of the capacitor.

ESR Spectroscopy에 의한 감마선 조사된 한약재의 검지 (Detection of Gamma-Irradiated Korean Medicinal Herbs by ESR Spectroscopy)

  • 이은정;양재승
    • 한국식품영양과학회지
    • /
    • 제31권4호
    • /
    • pp.717-721
    • /
    • 2002
  • ESR spectroscopy를 이용하여 한약재의 방사선 조사여부를 확인하였다. 국내산 한약재 4종으로 칡, 당귀, 아가리쿠스, 황기를 0, 1, 5 및 10 kGy의 Co-60 감마선을 조사한 후, 이를 시료로 Bruker-EPR spectrometer를 이용하여 조사로 생성된 라디칼을 측정하였다. 실험결과 조사직후 감마선 조사된 한약재 4종은 ESR 특성 신호를 나타내어 비조사시료와 확실하게 구별할 수 있었다. 적용선량의 범위에서(1~10 kGy) 조사선량이 증가함에 따라 ESR 신호 크기는 직선적으로 증가하였으며, 선량의 증가에 따른 신호 크기의 증가를 나타낸 $R^2$값은 0.9428~0.9942의 높은 값을 나타내었다. 또, 이들 신호는 상온에서 2주까지는 감소하였으나 저장기간 후에도 관찰할 수 있었으므로 ESR spectroscopy를 이용한 한약재의 방사선 조사여부 판별은 6주간의 저장 후에도 측정 가능한 방법임을 알 수 있었다.

Holstein의 임신기간별 경사시험관법에 의한 적혈구 침강율 연구 (Study on the Erythrocyte Sedimentation Rate by Angled Tube Method during Pregnant Period in Holstein)

  • 신종욱;김형욱
    • 한국임상수의학회지
    • /
    • 제16권1호
    • /
    • pp.8-12
    • /
    • 1999
  • The erythrocyte sedimentation rate (ESR) test could be applied well in clinic of men, horses or dogs. But the ESR test was not applied to clinic ruminants except for buffaloes since it was too low measure. To overcome this problem angled tube method was developed. This method was found to be useful for making diagnosis and prognosis. The results were summarized as follows. 1. In the early pregnancy condition, corrected ESR did not changed when compared with normal valures. 2. In the middle pregnancy condition, corrected ESR was increased when compeared with normal valures. 3. In the latter pregnancy condition, corrected ESR was increased when compeared with normal valures. 4. After parturition condition, corrected ESR did not changed when compeared with normal valures.

  • PDF

PWM 전력 컨버터에서 DC 링크 커패시터의 개선된 온라인 고장 진단 (An Improvement On-Line Failure Diagnosis of DC Link Capacitor in PWM Power Converters)

  • 손진근;나채동
    • 전기학회논문지P
    • /
    • 제59권1호
    • /
    • pp.40-46
    • /
    • 2010
  • DC link electrolytic capacitors are widely used in various PWM power converter system, such as adjustable speed driver(ASD) or DC/DC converter. Electrolytic capacitors, which is the most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. This objective of this paper is to propose a improvement method to detect the rise of equivalent series resistor(ESR) in order to realize the online failure prediction of electrolytic capacitor for DC link of PWM power converter. The ESR detection scheme is based on the determination of the electrolytic capacitor AC losses calculated from voltage/current measurement using AC coupling. Therefore, the preposed online failure prediction method has the merits of easy ESR computation and circuit simplicity compare with BPF method. Simulation results show the veridity of the proposed on-line ESR estimation method.

Investigation of High-Sensitivity C-reactive Protein and Erythrocyte Sedimentation Rate in Low Back Pain Patients

  • Park, Chan-Hong;Lee, Sang-Ho
    • The Korean Journal of Pain
    • /
    • 제23권2호
    • /
    • pp.147-150
    • /
    • 2010
  • Background: Chronic low back pain can be a manifestation of lumbar degenerative disease, herniation of intervertebral discs, arthritis, or lumbar stenosis. When nerve roots are compromised, low back pain, with or without lower extremity involvement, may occur. Local inflammatory processes play an important role in patients with acute lumbosciatic pain. The purpose of this study was to assess the value of erythrocyte sedimentation rate (ESR) and high sensitivity C-reactive protein (hsCRP) measurements in patients with chronic low back pain or radiculopathy. Methods: ESR and hsCRP were measured in 273 blood samples from male and female subjects with low back pain and/or radiculopathy due to herniated lumbar disc, spinal stenosis, facet syndrome, and other diseases. The hsCRP and ESR were measured prior to lumbar epidural steroid injection. Results: The mean ESR was 18.8 mm/h and mean hsCRP was 1.1 mg/L. ESR had a correlation with age. Conclusions: A significant systemic inflammatory reaction did not appear to arise in patients with chronic low back pain.

전자스핀공명을 이용한 자성체연구 소개 (ESR and its Application to Magnetic Research)

  • 최광용
    • 한국자기학회지
    • /
    • 제20권3호
    • /
    • pp.120-128
    • /
    • 2010
  • 전자스핀공명은 전자의 고유한 자기모멘트인 스핀과 마이크로파와의 상호작용을 통하여 물질 내의 상자성 이온에 관한 정보를 얻어내는 실험방법이다. 자성물성에 관한 연구를 포함하여 물리, 화학, 생물학, 의학 및 양자계산과 같은 넓은 분야에 응용되고 있다. 전자스핀공명실험으로 어떻게 상자성 이온의 g-텐서, 스핀 및 오비탈 상태에 대한 정보를 얻고 스핀간의 교환 상호작용력과 스핀-격자 및 스핀-스핀 완화시간을 측정할 수 있는가를 간단한 예들과 함께 소개한다.

DC/DC 컨버터를 이용한 DC Bus 커패시터의 간단한 ESR 측정 기법 (A Simple ESR Measurement Method for DC Bus Capacitor Using DC/DC Converter)

  • 손진근;김진식
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.372-376
    • /
    • 2010
  • Electrolytic capacitors have been widely used in power electronics system because of the features of large capacitance, small size, high-voltage, and low-cost. Electrolytic capacitors, which is most of the time affected by aging effect, plays a very important role for the power electronics system quality and reliability. Therefore it is important to estimate the parameter of an electrolytic capacitor to predict the failure. The estimation of the equivalent series resistance(ESR) is important parameter in life condition monitoring of electrolytic capacitor. This paper proposes a simple technique to measure the ESR of an electrolytic capacitor. This method uses a switching DC/DC boost converter to measure the DC Bus capacitor ESR of power converter. Main advantage of the proposed method is very simple in technique, consumes very little time and requires only simple instruments. Simulation results are shown to verify the performance of the proposed method.

소에 있어서 등장 dextrose액으로 희석한 혈액의 적혈구 침강율(ESR) 측정에 의한 적혈구 침층용적(VPRC)치의 간접계산법 (Indirect calculation for volume of packed red cell(VPRC) by means of erythrocyte sedimentation rate (ESR) of blood diluted with isotonic dextrose solution in cattle)

  • 이방환;박영우;민병만
    • 대한수의학회지
    • /
    • 제30권1호
    • /
    • pp.107-112
    • /
    • 1990
  • The purpose of this study is to derive indirect values of volume of packed red cell(VPRC), without centrifugation, from erythrocyte sedimentation rate(ESR) of blood diluted with isotonic dextrose solution in cattle. Each of ten blood samples taken from apprently healthy Korean cows and Holstein cows was used to produce eight different mixture of autologous plasma and blood corpuscles such that their values of VPRC lay between 15 to 50ml/100ml, and then each of the blood mixture was again diluted with 5% dextrose solution. The measurements of ESR using 45 degree-angled capillary hematocrit tube, 1.1~1.2mm bore, ($45^{\circ}$-micro-ESR) were practised for the diluted blood of various levels of VPRC under the ambient temperature of $10^{\circ}$, $20^{\circ}$ and $30^{\circ}C$. Reliable values of VPRC on the basis of the correlating linear regressive equation to the ESR could be derived from the values of $45^{\circ}$-micro-ESR/hr in the mixture of one part of whole blood and one part of 5% dextrose solution(1:1). For an aid of practical use, authors suggested a list of the $45^{\circ}$-micro-ESR/hr values of the diluted blood equivalent to VPRC of whole blood.

  • PDF

경주마(競走馬)에서 Westergren법(法)에 의한 적혈구 침강속도(沈降速度) 측정의 평가(評價) (Evaluation of erythrocyte sedimentation rate in racehorse measured by westergren method)

  • 김병진;이방환;이채용
    • 대한수의학회지
    • /
    • 제32권3호
    • /
    • pp.421-427
    • /
    • 1992
  • The study was basically carried out to establish the appropriate condition for applying the Westergren method for erythrocyte sedimentation rate(W-ESR) in Throughbred racehorses at recess. To do this, we examined the correlationship among some factors including the kind of anticoagulants, optimal ambient temperature and reading time for W-ESR in healthy racehorses. The difference between the blood samples treated with only 3.8% solution of sodium citrate(SC) and both EDTA and SC as a coagulant, there was not recognized any significant difference(p<0.05) in the levels of W-ESR irrespective of the ambient temperature of $20^{\circ}C$ or $30^{\circ}C$. The best optimal ambient temperature for W-ESR in horses was proved at $30^{\circ}C$ resulting from the tendency of the most reduced dispersion in mean values analyaed from repeatly 4 times to the same blood samles compared with those of $10^{\circ}C$ and $20^{\circ}C$. The optimal reading time was determined as 60 minutes(Y=237.2~4.1X, $r^2=0.998$) and 70 minutes(Y=247.8~4.2X, $r^2=0.999$) under the same temperature of $30^{\circ}C$; the latter showed the better result on the basis of the correlation of packed cell volume(PCV) and ESR values. About 13 healthy racehorses, we compared the real values of W-ESR respectively obtained at 60 minutes and 70 minutes at $30^{\circ}C$ with the anticipated values of PCV by means of the analysis of linear regression equitation. As the result of this, the strong correlation between both of them was confirmed. For practical use of W-ESR in Thoroughbred racehorese, we can recommend the condition of 60 or 70 minutes for the optimal reading time as well as $30^{\circ}C$ for the best ambient temperature.

  • PDF