• Title/Summary/Keyword: ESR

Search Result 679, Processing Time 0.029 seconds

ESR spectrum change for the a-C : H films exposed in the atmosphere (공기 중에 노출된 a-C : H 박막의 ESR 스펙트럼 변화)

  • 윤원주;이정근
    • Journal of the Korean Vacuum Society
    • /
    • v.13 no.2
    • /
    • pp.65-71
    • /
    • 2004
  • ESR spectrum change has been investigated for the PECVD deposited a-C : H films exposed in the atmosphere. Though depending on the deposition conditions, it was observed that generally ESR signal height decreased and linewidth increased as the exposure time increased. The spin density decreased down to 40-80% depending on samples. The decrease of spin density of the a-C : H films in the air was attributed to permeation of moisture into the films and subsequent migration and redistribution of hydrogens. And the ESR signal height increased again and the linewidth decreased when the a-C : H samples were placed again in the vacuum, which was attributed to oxygens extracted from the samples. Consequently, the ESR spectrum change for the a-C : H films exposed in the air was regarded to be associated with the decrease of spin density as well as the permeation of oxygens into films.

Comparative Evaluation of Erythrocyte Sedimentation Rate by the Test 1 Analyzer and Westergren method in Patients with Anemia (빈혈환자에서 자동 ESR 기기인 Test 1과 Westergren법의 비교)

  • Kim, Il Taek;Kim, Jong Seok;Park, Yeon Bo;Lim, Jae Sil
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.36 no.2
    • /
    • pp.137-143
    • /
    • 2004
  • Erythrocyte sedimentation rate(ESR) measurements were performed in a total of 191 blood samples from patients below a hematocrit of 35% by both the Test-1(SIRE Analytical Systems, Udine, Italy) and the Westergren method, endorsed as the reference method for ESR by the International Council for Standardization in Hematology(ICSH). The corrected Westergren ESR values were also obtained applying the formula of Fabry (corrected ESR = ESR measured x 15/55-Hct). Linear regression analysis showed a close correlation (r=0.85) between the two methods both before and after ESR correction in total samples. There was no significant correlation difference between two methods in both two groups with hemoglobin $${\geq_-}9g/dl$$ and <9g/dl before and after ESR correction (r=0.873, r=0.827 respectively before correction and r=0.867, r=0.830 respectively after correction). Also, for two groups with hematocrit $${\geq_-}24%$$ and <24%, no significant difference was observed (r=0.859, r=0.792 respectively before correction and r=0.782, r=0.842 respectively after correction). However, for samples with <60mm of Westergren ESR before correction, a better correlation coefficient was obtained than samples with $${\geq_-}60mm$$(r=0.701, r=0.541 respectively). In corrected Westergren ESR, also samples that were obtained with <40mm showed better correlation than samples with $${\geq_-}40mm$$ (r=0.690, r=0.347 respectively). In conclusion, we found a good correlation between Test-1 and Westergren measurements in patients with anemia but an expert group discussion is required to solve discrepancy between two methods in blood samples with very high ESR.

  • PDF

Relative Anticipated Erythrocyte Sedimentation Rate of Cattle Blood, as Measured by 45 Degree-Angled Capillary Hematocrit Tube, for Ambient Temperature and PCV Value (소 혈액의 45도 경사 모세관에 의한 ESR측정에 있어서 환경온도 및 PCV에 상관하는 관계적 예기ESR치)

  • Lee, Bang-whan
    • Korean Journal of Veterinary Research
    • /
    • v.27 no.2
    • /
    • pp.339-345
    • /
    • 1987
  • Each of twenty blood samples taken from apparently healthy Korean Cows was used to produce five different mixtures of autologous plasma and blood corpuscles such that their values of packed cell volume (PCV) lay between 10 to 50ml/l00ml. The measurements of erythrocyte sedimentation rate (ESR) using 45 degree-angled capillary hematocrit tube, 1.1-1.2mm bore, ($45^{\circ}-micro-ESR$) were practised for the blood of various levels of PCV under the ambient temperature of ${10^{\circ}C}$, ${20^{\circ}C}$ and ${30^{\circ}C}$. Correlation of ESR to ambient temperature showed linear regression each in five levels of PCV. ESR increased with ascending ambient temperature, and magnitude of the increase of ESR became greater as the level of PCV lowered. Correlation of ESR, of which values were transformed by the linear regression equation correlated to ambient temperature to PCV showed curvilinear regression each in three levels of ambient temperature, and ESR was increased with decreasing PCV. The data were statistically analysed and a list of relative anticipate $45^{\circ}-micro-ESR$ values for PCV and ambient temperature was presented.

  • PDF

Erythrocyte Sedimentation Rate: Its Determinants and Relationship with Risk Factors Involved in Ischemic Stroke

  • Kaur, Kirandeep;Kaur, Amandeep;Kaur, Anupam
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Erythrocyte sedimentation rate (ESR) evaluation is a useful tool for monitoring disease activity in various inflammatory and non-inflammatory conditions. ESR is known to be influenced by a multitude of confounding factors. The present study aimed to assess the possible determinants of the ESR and its relationship with various risk factors involved in ischemic stroke. ESR and other hematological and biochemical parameters were investigated in 163 ischemic stroke patients (107 males and 56 females) selected based on imaging techniques including magnetic resonance imaging (MRI) or computed tomography (CT) scans. Statistical analysis was performed using the SPSS 16.0 software. Linear regression analysis showed a significant inverse relationship of hemoglobin (Hb) and hematocrit or packed cell volume (PCV) (P<0.001 for females; P<0.01 for males) with the ESR. It was observed that the red blood cell (RBC) count was not strongly correlated with the ESR (P<0.05 for both males and females). It was also observed that sex significantly affected the variables determining the ESR levels, whereas age had no effect. Gender differences were also observed with respect to Hb, RBC, PCV, mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), and ESR. The possible determinants of higher ESR levels in ischemic stroke may be sex, Hb, hematocrit, and RBC count, but the role of other clinical and laboratory parameters cannot be underestimated.

Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$ ($SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가)

  • Lee, Jung-Ee;Kim, Kyung-Dong;Lee, Chae-Hoon;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.110-115
    • /
    • 1996
  • The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using $SEDIsystem^{TM}$ automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between $SEDIsystem^{TM}$ and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), $SEDIsystem^{TM}$ and Wintrobe y = 1.14x - 14.7 (r=0.789), respectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, $SEDIsystem^{TM}$ automated ESR measurement correlated with modified Westergren and Wintrobe methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that $SEDIsystem^{TM}$ automated ESR measurement may be useful tool for clinical practice.

  • PDF

A Study on a control algorithm and determinant of an optimal process condition based upon ESR process analysis. (ESR공정분석 밑 해석 모델렁을 통한 최적 공정 선정 밑 제어에 대한 연구)

  • 부광석;위철민;임태균
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.352-352
    • /
    • 2000
  • ESR(ElectroSlag Remelting) Process is secondary fine process and melts steels by electric resistance heat and fines the melting steels by an appropriate solidification process parameters which affects the melting and solidification processes to get the high quality products. This paper describes a method to derive the mathematical model and analysis the dynamic characteristics for designing a controller of the ESR processes. The ESR process consists of a melting and solidificating processes and electrical system include the contact resistance mechanism. In this paper, we consider only the static relationship between inputs and outputs of the electric system because the dynamics of the electric system is so fast compared with the melting and solidificating processes which are analysed by using finite difference method. As the results, the fine processing in ESR is analysed and the process controller could be designed based on the process dynamic analysis.

  • PDF

Development of High-Field ESR System Using SQUID Magnetometer and its Application to Measurement under High Pressure

  • Sakurai, T.;Fujimoto, K.;Okubo, S.;Ohta, H.;Uwatoko, Y.
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.168-172
    • /
    • 2013
  • We have developed a high-field and high-frequency ESR system using a commercially available magnetometer equipped with the superconducting quantum interference device (SQUID). This is magnetization detection type ESR and ESR is observed as a change of the magnetization at the resonance condition under irradiation of the electromagnetic wave. The frequency range is from 70 to 315 GHz and the maximum magnetic field is 5 T. The sensitivity is estimated to be $10^{13}$ spins/G. The advantage of this system is that the high-field ESR measurements can be made very easily and quantitatively. Moreover, this high-field ESR can be applied to the measurements under pressure by using a widely used piston-cylinder pressure cell.

Angled Capillary Method for Determining Erythrocyte Sedimentation Rate of Goat (경사모세관법(傾斜毛細管法)에 의한 산양혈액(山羊血液)의 적혈구침강율(赤血球沈降率) 측정(測定))

  • Shin, Sung-shik;Lee, Bang-whan;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.26 no.1
    • /
    • pp.187-194
    • /
    • 1986
  • The purpose of this study is to develop a new method which enables the goat ESR to be used as an effective clinical test. Blood samples were taken from 61 Korean native goats aged above one year old and the effect of tube inclinations, tube bores, tube lengths, environmental temperatures during tests and packed erythrocyte volumes (PCV) on the ESR were observed. The results were summarized as follows. 1. The ESR/hr using capillary hematocrit tube (Micro-Ht-tube) was gradually increased as the tube angle inclined from 90 (vertical) to 15 degrees and the best angle in view of both security and fast sedimentation rate was found to be an angle of 45 degrees. 2. The 45-degree angled ESR ($45^{\circ}$-ESR) increased as the diameter of tube bore decreased. 3. The tube length did not affect the $45^{\circ}$-ESR in percent. 4. The $45^{\circ}$-ESR increased with the increased environmental temperature during the ESR test. 5. The heparinized Micro-Ht tubes did not affect the $45^{\circ}$-ESR of EDTA-blood in healthy group but in anemic group. In the anemic group, the ESRs by the heparinized Micro-Ht-tubes were slightly higher than those by non-heparinized Micro-Ht-tubes. 6. By using the autologous plasma, PCV of the blood was adjusted to be 10, 20, 30, 40 and 50ml/100ml and $45^{\circ}$-ESRs were determined in the Micro-Ht-tubes. The $45^{\circ}$-ESRs increased as the values of PCV decreased. The regression of the $45^{\circ}ESR$ to PCV was curvilinear with the second degree polynomial, $Y=42.1838-1.7355X+0.0180X^2$(r=0.9997). 7. The $45^{\circ}$-ESR/hr, using non-heparinized Micro-Ht-tubes at $20^{\circ}C$, was determined in 35 healthy Korean native goats. The average PCV was $30.6{\pm}1.4ml/100ml$. The observed ESR values averaged $6.8{\pm}1.7%$ and the corrected ESR values to the standard PCV of 31ml/100ml averaged $6.5{\pm}1.2%$. From these results, the angled capillary tube method was found to be desirable ESR test of goat blood in which EDTA-blood is filled in nonheparinized Micro-Ht-tubes held at an angle of 45 degrees for an hour at $20^{\circ}C$.

  • PDF

Relative Anticipated Erythrocyte Sedimentation Rate of Cattle Blood, as Measured by 45 Degree-Angled Wintrobe Hematocrit Tube, for Ambient Temperature and PCV Value (소 혈액의 45도-경사-Wintrobe관에 의한 적혈구침강율 측정에 있어서 환경온도 및 적혈구침층용적치에 상관하는 관계적 예기 적혈구침강율)

  • Lee, Bang-whan;Park, Young-woo;Shin, Jong-uk
    • Korean Journal of Veterinary Research
    • /
    • v.28 no.1
    • /
    • pp.187-192
    • /
    • 1988
  • Each of twenty blood samples taken from apparently healthy Korean cows was used to produce five different mixtures of autologous plasma and blood corpuscles such that their values of packed cell volume(PCV) lay between 10 to 50ml/100ml. The measurement of erythrocyte sedimentation rate (ESR) using 45 degree-angled Wintrobe hematocrit tube, 3mm bore, ($45^{\circ}$-Wintrobe-ESR) was practiced for the blood of various levels of PCV under the ambient temperature of $10^{\circ}C$, $20^{\circ}C$ and $30^{\circ}C$. Correlation of the ESR to the ambient temperature showed linear regression each in five levels of PCV. The ESR increased with ascending ambient temperature, and magnitude of the increase of the ESR became greater as the level of PCV lowered. Correlation of the ESR to PCV showed curvilinear regression each in three levels of the ambient temperature, and the ESR was increased with decreasing PCV. The data were statistically analysed and a list of relative anticipated $45^{\circ}$-Wintrobe-ESR values for PCV and ambient temperature was presented.

  • PDF

sRNA EsrE Is Transcriptionally Regulated by the Ferric Uptake Regulator Fur in Escherichia coli

  • Hou, Bingbing;Yang, Xichen;Xia, Hui;Wu, Haizhen;Ye, Jiang;Zhang, Huizhan
    • Journal of Microbiology and Biotechnology
    • /
    • v.30 no.1
    • /
    • pp.127-135
    • /
    • 2020
  • Small RNAs (sRNAs) are widespread and play major roles in regulation circuits in bacteria. Previously, we have demonstrated that transcription of esrE is under the control of its own promoter. However, the regulatory elements involved in EsrE sRNA expression are still unknown. In this study, we found that different cis-regulatory elements exist in the promoter region of esrE. We then screened and analyzed seven potential corresponding trans-regulatory elements by using pull-down assays based on DNA affinity chromatography. Among these candidate regulators, we investigated the relationship between the ferric uptake regulator (Fur) and the EsrE sRNA. Electrophoresis mobility shift assays (EMSAs) and β-galactosidase activity assays demonstrated that Fur can bind to the promoter region of esrE, and positively regulate EsrE sRNA expression in the presence of Fe2+.