• Title/Summary/Keyword: EQUIPMENT PERFORMANCE

Search Result 3,567, Processing Time 0.033 seconds

Comparative Analysis on Competitiveness between Ports in Northeast Asia Employing Shift-share Analysis and DEA (변이할당기법과 DEA를 활용한 동북아시아 항만간 경쟁력 비교 분석)

  • Lee, Choongbae;Kwon, A Rim
    • Journal of Korea Port Economic Association
    • /
    • v.30 no.4
    • /
    • pp.219-254
    • /
    • 2014
  • Due to the recent development of globalization and supply chain management, growth of international trade has led to increasing cargo volume around the world. Since maritime logistics environments have changed, increased container ship size, improvement of harbor equipment, global port operation and rapid technological development have had an significant effects on shipping and port industry, which is contributing to competitiveness of port. Since a larger volume of port throughputs are generally regarded as an indicator of the more competitive port, inefficient port operation could reduce its competitiveness. On the other hand, high efficient ports could increase their competitive power while increasing cargo volume. This study aims at comparing competitiveness of the ports in the Northeast Asia by investigating changes of container throughputs and evaluating efficiency performance of ports. Shift-Share analysis and Data Envelopment Analysis(DEA) have been conducted with 21 Northeast Asian ports and then separated them into 4 groups for comparative analysis to identify competitive position of each port. The results of this study show that Incheon and Gwangyang port have been decreased container cargo volume, while volume of Busan port would increase by means of active marketing, various route development and incentive policy for the port.

A Study on Characteristics of Exhaust Gas Emissions of Water-Bunker Oil Mixed by Homogenizer (균질기에 의해 혼합된 물-벙커유의 배기가스 배출 특성에 관한 연구)

  • Choi, Jung-Sik;Han, Sang-Goo;Choi, Jae-Hyuk;Park, Sang-Kyun;Park, Ro-Seong;Kim, Dae-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.5
    • /
    • pp.518-524
    • /
    • 2013
  • In this study, we conducted a study on characteristics of exhaust gas emissions from boiler when water-bunker oil mixed by homogenizer was burned in boiler. The results showed that NOx concentration and CO concentration of the homogenized bunker oil was decreased by 19% and 54% compared to pure bunker oil pretreatment was not being performed. And, in the case of water-bunker A oil, the NOx concentration was decreased with increasing water mixing ratio in bunker A oil. In particular, the NOx concentration in exhaust gas of 20 %water-80 %bunker A oil decrease by 45 % compared with pure bunker-A. However, the CO concentration in exhaust gas of 20 %water-80 %bunker A oil shows irregular changes. This means that the mixing of water more than a certain amount can cause a decrease in combustion performance. From this result, it can be found that critical mixing ratio of water in bunker A oil for normal combustion is 15% in this study. Deposition amount of soot that is collected in the vicinity of the chimney was decreased with increasing water mixing ratio.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Establishment of Dissolution Specifications for Generic Drugs in Korea Pharmaceutical Codex Monograph - Nicametate Citrate Tablet, Norfloxacin Capsule (고시 수재 의약품의 용출규격 설정 - 구연산니카메테이트 정, 노르플록사신 캡슐)

  • Kim, Hee-Yun;Choi, Seon-Hee;Bang, Su-Jin;Han, Kyung-Jin;Choi, Sung-Hee;Baek, Ji-Yun;Kim, Dong-Sup;Kim, Young-Ok;Sohn, Kyung-Hee;Song, Young-Me;Sah, Hong-Kee;Choi, Hoo-Kyun
    • YAKHAK HOEJI
    • /
    • v.54 no.5
    • /
    • pp.362-369
    • /
    • 2010
  • Despite the fact that the dissolution test can serve as an effective tool for drug quality control and prediction of in vivo drug performance, there are a number of drugs with no established dissolution specifications because they were developed quite a long time ago. Under this circumstances, KFDA started the new project that establishes dissolution method and specifications for drugs with no dissolution specifications listed in the Korea Pharmaceutical Codex (KPC). This project aims for promoting the appropriate management of oral solid dosage forms. Seoul regional KFDA selected 2 items, Nicametate citrate tablet and Norfloxacin capsule, for establishing dissolution specifications. We went through the following procedures to develop the dissolution method and specifications: (1) Validation of dissolution test equipment, (2) Purchase of test drugs, (3) Preliminary test with one of the test products (1 lot), (4) Validation of analysis methods (3 lots), (5) Final tests and cross tests among other laboratory to establish dissolution specifications, (6) Additional test with the other test drugs. The outcome of this study will be reflected in revision of the KPC. It is believed that the quality control and evaluation of oral solid dosage forms listed in KPC will be advanced with the revision which adds additional dissolution test and specifications for the drugs with no established dissolution specifications.

Real-Time Construction Resource Monitoring using RFID/USN Inter-working System (RFID/USN 연동 시스템을 활용한 건설자원 실시간 모니터링 시스템)

  • Ryu, Jeoung-Pil;Kim, Hyoung-Kwan;Kim, Chang-Yoon;Kim, Chang-Wan;Han, Seung-Heon;Kim, Moon-Kyum
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.90-94
    • /
    • 2007
  • Location tracking automation of resources in construction industry is one of the most important procedures to improve construction project performance and reduce the period of construction. Recently, location tracking technologies have proven to be effective in tracking construction materials and equipment in real time through the instrumentality of RFID (Radio Frequency Identification). By using wireless communication and inter-working system between RFID and USN, it is possible that construction engineers receive the location information of construction resources without additional efforts that move the RFID reader to read tags periodically. In the inter-working system, RFID reader delivers the acquired materials information to sensor node which is connected by serial interface. Then sensor node transmits the received data to the data aggregation terminal that is a sink node. The data aggregation terminal can transmit collected data to construction manager who is out of construction site using infrastructure such as CDMA(Code Division Multiple Access) network. The combination model of the two system and field test scenarios are presented in this paper.

  • PDF

A Frame Stress and Integration Monitoring System based on Continuous Track Type for Multipurpose Application of Electric Wheelchair (전동휠체어의 다목적 활용을 위한 무한궤도형 기반의 프레임 응력 및 통합 모니터링 시스템)

  • Jo, Kyeong-Ho;Jung, Se-Hoon;Park, Jae-Sung;Yoo, Seung-Hyun;Sim, Chun-Bo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.5
    • /
    • pp.1135-1144
    • /
    • 2018
  • An electric wheelchair used to be utilized as a piece of equipment for the disabled and the elderly in the past, but the recent changes to its functions and forms have made it available across various fields and purposes. In this paper, we propose a continuous track type of electric wheelchair prototype to be used in various fields and environments and a monitoring system to control it. A frame stress design was applied to improve its stability during driving compared with the previous wheelchairs. In addition, we provide a convenience for free and easy operation of them using the App. based on android. A monitoring system based on C# was also added to control a large number of electric wheelchairs. As a result of the implementation and performance evaluation, the von Mises stress value was measured 4.401% within the normal range through five times of stress interpretations, and its accuracy of communication for system manipulation was recorded about 98.75%, which means that it has been proven to be safer than the previous wheelchairs.

A Study on Protection Depending on Mesh Size of Expanded Metal for Slope Reinforcement (사면보강용 Expanded Metal 격자크기에 따른 인발 특성 연구)

  • Ji, Younghwan;Kim, Kihwan;Kim, Sungho;Hwang, Yeongcheol;Lee, Seungho
    • Journal of the Korean GEO-environmental Society
    • /
    • v.11 no.12
    • /
    • pp.47-56
    • /
    • 2010
  • The construction of new roads and the consistent extension of already-existing roads or the line-shape revision of those roads are increased with the governmental investment to SOC facilities currently. Accordingly, the road cut slopes are in the trend of rapidly increasing. As the road slope has increased, a lot of human and property damages has entailed consequently and in the local case, numerous studies have carried out aiming at minimizing this damages caused by the rockfall and landslide. In general, standard falling rock prevention facility has employed for most of the local road slope based on "Guide for Installation and Management of Road Safety Facilities" published by MLTM(the Ministry of Land, Transport, and Maritime Affairs) but profound doubt has raised as to whether this rockfall prevention facility would function properly enough to prevent rockfall efficiently without any damages in case of actual occurrence of rockfall. In addition, it is a reality that in most cases, such work is relied on overseas technology as a whole as the local technical level is low and in case of rockfall prevention net, it is judged that a study on rockfall prevention net that is able to endure more powerful rockfall energy is required as the problem including net bursting is taken place as a result of enough bearing force being failed to be demonstrated due to its partial weak point(not uniformly made). Under this background, in this study, three kinds of model depending on mesh size of expanded metal that is considered to have an adoptability as rockfall prevention net, as target are selected and characteristics depending on mesh size of expanded metal is intended to be researched through a pull-out test performance by using pull-out test equipment rockfall prevention net.

The Operating Objective of Automated Container Terminal by the AHP Techniques : The Case of Port of Gwangyang Automated Container Terminal (AHP기법을 활용한 자동화 컨테이너터미널 운영목표 설정에 관한 연구 : 광양항 자동화 컨테이너터미널을 대상으로)

  • 박남규;최형림;이창섭
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.223-230
    • /
    • 2003
  • KCTA(Korea Container Terminal Authority) is going to introduce automated operating system in the port of Gwangyang container terminal to enhance the efficiency. Prior to developing the container terminal, defining the objective of container terminal operation is essential. This research used AHP technique to define the operation objective of automated container terminal objectively, and the questionnaire to collect the opinions of future customer, operator and research institution. The objectives mix of the automated container terminal are composed of the minimization of initial investments, the minimization of operational expenses, the performance of automation system, the raising of operation efficiency and productivity and the improvement of customer service. The result of the analysis revealed that most important factor among objectives mix was “the minimization of operation expense”. Especially, the user group preferred to select the factor of “the improvement of customer service”as objective rather than select other objectives. The result of this research will suggest some guidelines for deciding the level of investment of terminal construction. information system, automation equipment, terminal worker and etc., which are to be considered in terminal development and the system development hereafter.

  • PDF

The Restructuring of the Chemical Industry in Jilin City, China (중국 지린(吉林)시 화학공업의 재구조화)

  • Lu, Bi-Shun;Zhan, Jun
    • Journal of the Korean association of regional geographers
    • /
    • v.15 no.6
    • /
    • pp.720-735
    • /
    • 2009
  • This paper studies the characteristics of the restructuring of chemical industrial complex in JiLin city since 1978 focusing on enterprise organization, the process of production, labor, and consumer market. The number of chemical industrial enterprises and their partnership with subcontractors have increased since 2001. As for the type of cooperation group, research institutes and local government are accounted for the greatest portion. The chemical industrial enterprise in JiLin which has adopted Fordism production method still has the highest percentage in 2007. And in the shift process of production system after China's entry into WTO(in 2001), chemical industrial enterprise in JiLin city takes allowing more investment in production technologies as core strategy, while taking improvement in equipment and development of new products as core strategy in the shift process of production technology. The degree of labor re-education was highest in 2007, and as for the relationship between labor and management, enterprises which evaluate the ability of performance of duty are increasing. The characteristics of restructuring of chemical industrial complex on consumer market, domestic market accounted for the greatest portion, on the other side the export is feeble. As for strategy of market restructuring, industrial enterprise in JiLin city should use Quality improvement and high-value added as core strategies to cope with alteration of market.

  • PDF

Study on the Change of Absorbed Dose and Image Quality according to X-ray Condition of Detector in Digital Radiography(DR) (Digital Radiography(DR)에서 검출기의 X선 조건에 따른 흡수선량 및 영상화질 변화에 관한 연구)

  • Hwang, Jun-Ho;Jeong, Jae-Ho;Kim, Hyun-Soo;Lee, Kyung-Bae
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.9
    • /
    • pp.99-106
    • /
    • 2017
  • This study focused on the issue that when a diagnostic detector is found to have a defect, a patient would be exposed to radiation and image quality would be degraded. Though dose analysis, an experiment was conducted to evaluate detector performance as Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Absorbed dose, SNR and CNR were measured using a dosimeter and a tissue equivalent phantom. The experiment was conducted to compare whether the dose value shown after being attached to the back side of the phantom matches the dose value attached behind the detector, where in the conditions of skull, chest and abdomen were set at 75 kVp, 25 mAs, 110 kVp, 8 mAs, and 80 kVp, 20 mAs, respectively. As a result, there was a difference in that the dose values attached to the back side of the detector were 0.004 mGy, 0.006 mGy, 0.003 mGy, whereas those of the back side of the phantom were 0.006 mGy, 0.016 mGy, 0.017 mGy. In order to match both values, the condition was increased and SNR and CNR also increased from 88.32, 88.10, 4.09, 1.63, 87.94, 79.97 to 93.87, 93.75, 4.91, 4.03, 92.02, 84.92. Though this study, we found that when a detector is found to have a aging, it shortens the life of equipment and increases the dose of a patient, also the improvement effect of image quality is inadequate.