• Title/Summary/Keyword: EQUIPMENT PERFORMANCE

Search Result 3,531, Processing Time 0.031 seconds

Seismic behavior of simplified electrical cabinet model considering cast-in-place anchor in uncracked and cracked concretes

  • Bub-Gyu Jeon;Sung-Wan Kim;Sung-Jin Chang;Dong-Uk Park;Hong-Pyo Lee
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4252-4265
    • /
    • 2023
  • In the case of nuclear power plants near end of their design life, a reassessment of the performance of safetyrelated equipment may be necessary to determine whether to shut down or extend the operation of the power plant. Therefore, it is necessary to evaluate the level of performance decline due to degradation. Electrical cabinets, including MCC and switchgear, are representative safety-related equipment. Several studies have assessed the degradation and seismic performance of nuclear power plant equipment. Most of those researches are limited to individual components due to the size of safety-related equipment and test equipment. However, only a few studies assessed the degradation performance of electrical cabinets. The equipment of various nuclear power plants is anchored to concrete foundations, and crack in concrete foundations is one of the most representative of degradation that could be visually confirmed. However, it is difficult to find a study for analysis through testing the effect of cracks in concrete foundations on the response of electrical cabinet internal equipment fixed by anchors. In this study, using a simple cabinet model considering cast-in-place anchor in uncracked and cracked concretes, a tri-axial shaking table tests were performed and the seismic behavior were observed.

Test Method for Particle Removal Characteristic of Equipment Fan Filter Unit (EFFU) (Equipment Fan Filter Unit (EFFU)의 Particle 제거 성능평가 방법)

  • Lee, Yang-Woo;Ahn, Kang-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.2
    • /
    • pp.59-62
    • /
    • 2012
  • This test method covers a procedure for measuring particle removal characteristic of equipment fan filter unit(EFFU) installed inside of semiconductor process equipments, FPD manufacturing equipments and so on. Since EFFU is a combination of air filter and the assembly of fan, motor and frame, the integrity of these parts is very important for the performance of EFFU. So a conventional particle removal test method for air filters is not suitable for EFFU particle removal performance. This test method defines an evaluation method for EFFU which is installed inside an enclosed space to remove particles that are generated inside process equipment. The particle removal performance of EFFUs is usually depending on the performance of filter media and air flow rate. To understand a performance of an EFFU, the filter media characteristic, air flow rate and the integrity of EFFU parts should be considered simultaneously. This test method is intended to demonstrate the system performance of an EFFU and successfully evaluated EFFU performance characteristics.

A Study on the Performance Analysis of Degasser System with Vacuum Pump for Onshore and Offshore Drilling (육상 및 해양 시추용 디개서 시스템의 진공펌프 성능해석)

  • Kwon, Seong-Yong;Park, Sung-Gyu;Shin, Chul-Soon;Kim, Seung-Chan;Lim, Hee-Yeon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.6_2
    • /
    • pp.1063-1069
    • /
    • 2022
  • In modern industry, vacuum has grown into an indispensable industrial field. The performance of the vacuum pump in the degasser system among mud treatment system facilities was verified by a numerical analysis method. The degasser system is an equipment for removing the gas contained in the mud, and it is a work process that requires a vacuum. This study analyzed the vacuum pump performance of the degasser used in drilling for resource development of onshore and offshore plants. The vacuum pump used in the degasser system was designed with a discharge rate of 0.099kg/s. The DM(Design Modeler) program of ansys workbench 17.2 was used to modify the model of the vacuum pump used in the degasser system. And for performance analysis, CFX, which is known to be suitable for rotating system analysis, was used. Finally the performance analysis results of the vacuum pump and the prototype performance test results were compared and analyzed.

Development of Hydraulic Device Performance Test Equipment Automation Process (유압 디바이스 성능 검사 장비 자동화 공정 개발)

  • Kim, Hong-Rok;Chung, Won-Jee;Seol, Sang-Seok;Park, Sang-Hyeok;Lee, Kyeong-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.10
    • /
    • pp.74-80
    • /
    • 2020
  • Crawler-type hydraulic devices facilitate forward and backward driving of construction equipment by converting power into mechanical energy. The existing hydraulic device performance test process is time- and labor-intensive. This study aims to improve efficiency and productivity by automating the hydraulic device production performance test processes, which have been separately conducted so far. We also used SolidWorksⓇ, a 3D modeling program, and ANSYSⓇ, a structural analysis tool, for structural analysis and to verify the suitability of fixing pins required for connecting a hydraulic device to performance test equipment. Our results that employing an automated hydraulic device performance test process improves efficiency.

A study on improving the performance of special ambulances (특수구급차 성능 개선을 위한 조사 연구)

  • Yoon, Byoung-Gil;Yang, Hyun-Mo;Kim, Gyoung-Yong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.26 no.1
    • /
    • pp.87-99
    • /
    • 2022
  • Purpose: This study aimed to provide basic data for the improvement of the standards related to the performance improvement of the firefighting equipment standards for special ambulances. Methods: Among the domestic firefighting equipment standards, the special ambulance standard was compared with the NFPA 1917 standard for the United States automobile ambulance 2019 and European Union European standard EN 1789 medical vehicle and its equipment, a road ambulance. Results: Anti-skid performance based on indoor noise standards, performance standards for interior lights, seat belt warning device, child car seat fixing device, safety handle, auxiliary footrest, and flooring materials should be supplemented. Conclusion: It is necessary to strengthen the production and performance standards for improvement to a level corresponding to the national standards, such as the United States and European Union.

Design and Basic Performance Test of 4 Inch QC/DC Bellows for LNG Bunkering (LNG 벙커링용 4인치 QC/DC의 설계 및 기초 성능 실험)

  • Jang, Sung-Cheol;Seo, Chang-Myung;Kwen, Min-Soo;Eom, Jeong-Pil;Jung, Hyun-Cheol
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.2
    • /
    • pp.81-86
    • /
    • 2019
  • Although the localization rate of shipbuilding and marine equipment goods is set to be 70 percent by 2020, but the localization rate of equipment and materials for shipbuilding and marine facilities is currently 10 to 30 percent. For Korea's Big 3 shipbuilders, which build 70 percent of the world's largest shipbuilders, localization of shipbuilding equipment and equipment is an essential factor. In particular, there is a growing need to localize equipment and materials in terms of the number of lead standards and A/S. It is expected that there will be a rapid expansion of LNG carriers in the future, and it is necessary to develop equipment and equipment materials of LNG ships. In this study, the design and manufacture of LNG vessel equipment was conducted. Design and basic performance tests of 4-inch QCDC for LNG bunkering were conducted.

Analysis of Safety and Performance Vulnerabilities Using Heat-Using Equipment(Industrial Boiler) Inspection Results (열사용기자재 검사대상기기(산업용 보일러) 검사결과를 활용한 안전 및 성능 취약점 분석)

  • Kim, Hyung-Jun;Oh, Choong-Hyeon
    • Journal of the Korean Institute of Gas
    • /
    • v.26 no.4
    • /
    • pp.18-26
    • /
    • 2022
  • The Korean government is conducting heat-using equipment(industrial boiler) inspection in accordance with the Energy Use Rationalization Act because of the heat-using equipment(industrial boiler)'s risks such as explosion and fire, and safe use and management. This paper aimed to setup the safe and performance vulnerabilities from database based on the inspection results for heat-using equipment(industrial boiler). This study surveyed the inspection results of 1,249 heat-using equipment(industrial boiler) which were failed inspection of heat-using equipment(industrial boiler) from january 2016 to december 2020. And the analysis method is to inform safety and performance vulnerability categories of heat-using equipment(industrial boiler) by statistically analyzing the failure reasons of boiler type and inspection type which are high variance in failure rate. The safety and performance vulnerability categories was abbreviated into 18 cases. And each catagory's main reason for failure was suggested by additional analyzing the opinions of inspectors. This paper would be the basic source and the comprehensive information dealing with the safety and performance vulnerability of heat-using equipment(industrial boiler).

Analysis of Awareness Performance for Applying RFID in Electric Power Equipment (발전설비장치에서 RFID 적용을 위한 인식성능 분석)

  • Hong, Jin-Keun;Han, Gun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2313-2318
    • /
    • 2009
  • In this paper, when the power equipment, which is based on RFID, is managed, it is reviewed the performance of RFID frequency recognition and its scheme is required to manage status information efficiently. The proposed paper is studied for optimization of recognition performance, when tags are attached the power equipment & major components, to diagnosis failure status of power equipment in monitoring service. The results of paper is valuable applying environment of power equipment.

Evaluation of the seismic performance of butt-fusion joint in large diameter polyethylene pipelines by full-scale shaking table test

  • Jianfeng Shi;Ying Feng;Yangji Tao;Weican Guo;Riwu Yao;Jinyang Zheng
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3342-3351
    • /
    • 2023
  • High-density polyethylene (HDPE) pipelines in nuclear power plants (NPPs) have to meet high requirements for seismic performance. HDPE pipes have been proved to have good seismic performance, but joints are the weak links in the pipelines, and pipeline failures usually initiate from the defects inside the joints. Limited data are available on the seismic performance of butt-fusion joints of HDPE pipelines in NPPs, especially in terms of defects changes inside the joints after earthquakes. In this paper, full-scale shaking table tests were performed on a test section of suspended HDPE pipelines in an NPP, which included straight pipes, elbows, and 10 butt-fusion joints. During the tests, the seismic load-induced strain of the joints was analyzed by strain gauges, and it was much smaller than the internal pressure and self-weight-induced strain. Before and after the shaking table tests, phased array ultrasonic testing (PA-UT) was conducted to detect defects inside the joints. The locations, numbers, and dimensions of the defects were analyzed. It was found that defects were more likely to occur in elbows joints. No new defect was observed after the shaking table tests, and the defects showed no significant growth, indicating the satisfactory seismic performance of the butt-fusion joints.

A Study on Reliability, Safety Analysis and Related Performance Improvement of Avionics Equipment (항공전자장비 신뢰성, 안전성 분석 및 관련 성능 개선 방안 연구)

  • Seo, Joon-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.9
    • /
    • pp.1220-1227
    • /
    • 2018
  • Avionics electronic equipment refers to the electronic equipment installed on an aircraft. Failure of avionics equipment can have a significant impact on aircraft operations as well as threaten the safety of pilots and passengers. Therefore, avionics electronic equipment is required to have higher reliability and safety than electronic equipment used for other purposes. Avionics equipment must consider various component selection and system design to meet reliability and safety-related requirements from the initial design stage. In this paper, we describe safety, reliability performance analysis method of avionics equipment, and introduce various design improvement methods that can be performed to meet safety requirement performance. Finally, the safety performance of the improved avionics equipment was reanalyzed and compared with the value before the improvement, the validity of the proposed design change was verified.