• 제목/요약/키워드: ENERGY SAVING REPLACEMENT

검색결과 25건 처리시간 0.024초

Application of zeolite/kaolin combination for replacement of partial cement clinker to manufacture environmentally sustainable cement in Oman

  • Abdul-Wahab, Sabah A.;Hassan, Edris M.;Al-Jabri, Khalifa S.;Yetilmezsoy, Kaan
    • Environmental Engineering Research
    • /
    • 제24권2호
    • /
    • pp.246-253
    • /
    • 2019
  • This study was conducted to explore the optimum proportion of zeolite and zeolite-kaolin as additives to cement clinker and gypsum samples, while maintaining the strength properties of produced environmentally sustainable cements. According to the British standard method, zeolite was added to cement clinker in proportions of 5-12% and 10-12% by weight, respectively, in the preparation of samples of zeolite-containing cement and zeolite-kaolin-based cement. Kaolin was used as a second additive as 10-20% of the total weight. The compressive strength tests were performed on base cement samples according to a standard procedure given in ASTM C109 Compressive Strength of Hydraulic Cement. These values were compared with those of the reference sample and the Omani allowable limits. The results indicated that the best compressive strength values were obtained with 88% cement clinker, 5% gypsum, and 7% zeolite for the zeolite-containing cement. Quantities of 70% cement clinker, 5% gypsum, 10% zeolite, and 15% kaolin gave the best results for zeolite-kaolin-based cement, resulting in a substitution of than 25% cement clinker. The study concluded that the partial cement clinker replacement using zeolite/kaolin combination may have a great influence on the reduction of $CO_2$ emission and energy saving in cement manufacturing.

하수처리시설의 에너지자립화 및 경제적 효과분석 (Study on Energy Independence Plan and Economic Effects for Sewage Treatment Plant)

  • 박기학;이호식;하준수;김극태;임채승
    • 한국물환경학회지
    • /
    • 제37권2호
    • /
    • pp.128-136
    • /
    • 2021
  • It is generally known that a wastewater treatment plant (WWTP) consumes immense energy even if it can produce energy. With an aim to increase the energy independence rate of WWTP from 3.5% in 2010 to 50% in 2030, the Korean government has invested enormous research funds. In this study, cost-effective operating alternatives were investigated by analyzing the energy efficiency and economic feasibility for biogas and power generation using new and renewable energy. Based on the US EPA Energy Conservation Measures and Korea ESCO projects, energy production and independence rate were also analyzed. The main energy consumption equipment in WWTP is the blower for aeration, discharge pump for effluent, and pump for influent. Considering the processes of WWTP, the specific energy consumption rate of the process using media and MBR was the lowest (0.549 kWh/㎥) and the highest (1.427 kWh/㎥), respectively. Energy-saving by enhancing anaerobic digester efficiency was turned out to be efficient when in conjunction with stable wastewater treatment. The result of economic analysis (B/C ratio) was 2.5 for digestive gas power generation, 0.86 for small hydropower, 0.49 for solar energy, and 0.15 for wind energy, respectively. Furthermore, it was observed that the energy independence rate could be enhanced by installing energy production facilities such as solar and small hydropower and reducing energy consumption via the replacement of high-efficiency operating.

산업용 클린룸에서의 Teardrop LED 등기구 개발 및 경제성 분석에 관한 연구 (A Study on Developing a Teardrop LED Lighting Fixture and Economic Analysis at Industrial Clean Rooms)

  • 이상춘;최여진;최영준
    • KIEAE Journal
    • /
    • 제13권4호
    • /
    • pp.63-68
    • /
    • 2013
  • On the electricity consumption in Korea, the lighting sector takes about 17% of annual total electricity consumptions. In the midst of higher interests on energy conservation measures, design and choice of energy-saving lighting fixtures have been more important. With growth of technology-intensive industries like advanced material, semiconductor, and biotechnology from the 1980s, needs for clean room and thus illumination at clean rooms have been increased. In this paper, development, specification, and features of a Teardrop LED(hereinafter TD LED) lighting fixture as replacement of Teardrop florescent lighting one that has been popularly installed at clean rooms were presented. Also we performed the economic analysis of return on investment(ROI) about energy savings by the installation of the TD LED lighting fixture at a new-built clean room. The economic analysis showed that the new-developed TD LED lighting fixture would be able to withdraw the initial installation cost within 4 years. Lastly, improvement directions and development plans of the next TD LED lighting fixture for wider applications at clean rooms were described.

홍콩 친환경 재생공간의 친환경성 분석 (An Environment-friendly Analysis of Hong-kong Environment-friendly Reuse Space)

  • 김사라;남경숙
    • 한국실내디자인학회논문집
    • /
    • 제21권3호
    • /
    • pp.194-202
    • /
    • 2012
  • The purpose of this study is to extract environment-friendly planning elements to apply in Korea by putting together and reclassifying four foreign environment-friendly certification systems related to regeneration spaces - LEED in USA, CASBEE in Japan, BREEAM in England and BEAM in Hong Kong - and analyze and evaluate domestic and foreign spaces which were certified as Environment-friendly spaces in order to offer plan guidelines to raise awareness of the importance of environment-friendly elements in regeneration spaces and to encourage them. The concept and the characteristics of green building were studied through documentary survey. In addition, green certification system of the present domestic new spaces and foreign regeneration spaces was studied and assessment tools for indoor regenerated spaces-related green certification system were developed. With checklists which are developed in this study, level of going green of foreign spaces certified environment-friendly was assessed. Based on the results of this study, conclusions are as follows. As a result of case research of spaces-certified green of Hong-Kong's existing buildings with a developed checklist, application of general assessment part was all alike, but that of detailed assessment part was different. However, Hong Kong showed superiority in lighting energy saving, separate collection of recyclable domestic waste, recycling by-product and management. In addition, Hong Kong applied eco-friendly planning elements maintaining buildings in their condition as possible as it could with management, use of green program, replacement with high efficiency lighting, monitoring system, installation of recycling bins and energy saving by attaching reflective film.

  • PDF

형광램프대체용 LED FDL 개발 (Development of The LED FDL for Replacing Fluorescent Lamp)

  • 양병문;장우진;차재상
    • 조명전기설비학회논문지
    • /
    • 제29권1호
    • /
    • pp.9-14
    • /
    • 2015
  • Due to the declining LED price and environment-friendly energy policies, CO2 emission reduction and energy-saving, the LED lighting industry is accelerating rapidly. In particular, the needs for LED lamp, replacing the existing fluorescent lamp without exchange luminaire or driver circuits, are also rapidly increasing. Therefore, replacement for T8 fluorescent lamp, LED T8 lamp was developed and standardized. However, except LED T8 lamps, other lamps' regulations or standards were not enacted. Also, the stability of fluorescent lamp substitutable LED lamp is low due to the difference in electrical characteristics and mismatch between the existing fluorescent lamp ballast and LED lamp. Therefore, many are struggling while developing fluorescent lamp substitutable LED lamp. In this paper describes the properties of existing fluorescent lamp ballasts and the considerations while developing fluorescent lamp substitutable LED lamp : demonstrating its validity by experiments the developed fluorescent lamp substitutable LED lamp prototype.

지속가능 섬유 소재 추적성과 저탄소화 공정 (Low Carbonization Technology & Traceability for Sustainable Textile Materials)

  • 최민기;김원준;심명희
    • 한국의류산업학회지
    • /
    • 제25권6호
    • /
    • pp.673-689
    • /
    • 2023
  • To realize the traceability of sustainable textile products, this study presents a low-carbon process through energy savings in the textile material manufacturing process. Traceability is becoming an important element of Life Cycle Assessment (LCA), which confirms the eco-friendliness of textile products as well as supply chain information. Textile products with complex manufacturing processes require traceability of each step of the process to calculate carbon emissions and power usage. Additionally, an understanding of the characteristics of the product planning-manufacturing-distribution process and an overall understanding of carbon emissions sources are required. Energy use in the textile material manufacturing stage produces the largest amount of carbon dioxide, and the amount of carbon emitted from processes such as dyeing, weaving and knitting can be calculated. Energy saving methods include efficiency improvement and energy recycling, and carbon dioxide emissions can be reduced through waste heat recovery, sensor-based smart systems, and replacement of old facilities. In the dyeing process, which uses a considerable amount of heat energy, LNG, steam can be saved by using "heat exchangers," "condensate management traps," and "tenter exhaust fan controllers." In weaving and knitting processes, which use a considerable amount of electrical energy, about 10- 20% of energy can be saved by using old compressors and motors.

An experimental study on effect of Colloidal Nano-Silica on tetranary blended concrete

  • Reddy, Avuthu Narender;Meena, T.
    • Advances in concrete construction
    • /
    • 제7권2호
    • /
    • pp.107-115
    • /
    • 2019
  • The possibility of using a combination of mineral admixtures as a replacement for cement may reduce the $CO_2$ emission which causes global warming and climatic changes on the environment. By using the combination of different byproducts from various industries, for replacing cement in concrete leads to saving in energy and natural resources. In this article, an attempt has been made to study the mechanical and water absorption properties of concrete incorporated with combination of Fly ash (FA), Alccofine (ALC) and Collodial Nano Silica (CNS) at 7, 28 and 56 days curing period. Cement has been partially replaced by combination of FA at 25%, ALC at 10% and CNS at 0.5%, 1%, 2% and 3% with water cement ratio of 0.43. The result indicates that the incorporation of combination of FA, ALC and CNS can be very effective in improvement of mechanical and water absorption properties of concrete. The Mix with a combination of 25% FA, 10% ALC and 1% CNS is most effective in improvement of mechanical and water absorption properties as compared with all other mixes.

메탈핼라이드 집어등용 전자식 안정기 개발 (Development of a metal-halide lamp's electronic ballast)

  • 박성욱;배봉성
    • 수산해양기술연구
    • /
    • 제49권2호
    • /
    • pp.116-125
    • /
    • 2013
  • Jigging and angling fishery is prevalent in the East Sea of Korea and this fishery needs many lamps to attract the fish. And the fishing boat uses 24~47 ballasts by the vessel's tonnage to turn on the fishing lamp. A 3.5kW magnetic-type ballast being currently used at many fishing boats can drive two 1.5kW metal-halide lamps. Meanwhile, this ballast has large weight (25kg) and volume. Therefore it is one of reason for the over-consumption of energy and the fire, resulted from overheat and electrical short, occurs occasionally because the ballast is installed at narrow and hot engine room. In addition, most of magnetic ballast has several problems such as periodic condenser replacement, low energy efficiency and making lamp short life, etc. So it is necessary to improve or develop newly the electronic ballast, which has to be smaller, lighter and more efficient. An electronic ballast was designed for the fishing boat by considering duration and electromagnetic interference in the study. Its weight and volume are respectably 40% and 66% compared to current ballast on the basis of PCB. The metal-halide lamp's spectrum of the designed ballast was nearly same to that of the current ballast in the test of lighting. In particular, the light stability was improved and there isn't any radio interference. As mentioned above, it is expected that the developed electronic ballast can replace current magnetic ballast because of many advantages related to energy-saving.

중앙난방방식을 지역난방.소형열병합난방방식으로 전환시의 경제성 비교 분석 (Analysis for the Economic efficiency of District Heating and Gas Engine Co-generation System comparing with Central Heating System)

  • 김규생;이상혁;홍경표;원영재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.459-465
    • /
    • 2007
  • This study was conducted to calculate the LCC of a apartment complex with a type of heating system, district heating and cogeneration system. For the purpose of analyzing LCC according to size of apartment complex, 500, 1,500 and 4,000 houses of model apartment selected. This research performs design of heating system and the life cycle cost analysis including an initial cost, energy cost, maintenance and operation cost, replacement cost and renovation cost during the project period(15years). According to the calculated results, 1) Initial cost of cogeneration system with 500, 1500 and 4000 houses is higher than district heating system each of 20%, 13%, 12%. 2) In case of cogeneration system, the payback period by electric generation is 5.21, 4.92 and 4.47 years and saving cost was calculated 29 billion won, 94 billion won and 262 billion won after payback period. 3) Cogeneration system LCC was 1.12, 1.07 and 1.06 times larger than district system with the size of apartment complex. According to the case of this study district heating system is more efficient than cogeneration system in terms of the reduction of LCC. 4) Gas Engine Co-generation System is more efficient than other systems because it can collect progressive part from electric charge progressive stage system. However, the efficiency is decreasing because of raising of fuel bills(LNG) and lowering of power rate for house use. Especially the engine is foreign-made so the cost of maintenance and repair is high and the technical expert is short. 5) District heating is also affected by fuel bills so we should improve energy efficiency through recovering of waste heat(incineration heat, etc.). Also, we should supply district cooling on the pattern of heat using of let the temperature high in winter and low in summer.

  • PDF

에드 혹 네트워크에서 최적 경로의 유효성 있는 클러스터링 알고리즘에 관한 연구 (A Study of Optimal path Availability Clustering algorithm in Ad Hoc network)

  • 오영준;이강환
    • 한국정보통신학회논문지
    • /
    • 제17권1호
    • /
    • pp.225-232
    • /
    • 2013
  • 본 논문에서는 노드의 위치 정보와 유효성 경로에 따라 클러스터링내의 헤드 노드를 선출하는 방법 중 하나로 에너지 효율성을 고려한 ECOPS(Energy Conserving Optimal path Schedule) 알고리즘을 제안한다. 기존 LEACH 알고리즘은 헤드 노드를 선출할 때 노드의 에너지 확률적 분포 함수에 기반 하여 헤드 노드의 주기를 선택적으로 관리하게 된다. 그러나 이 경우 중계노드의 거리 정보 등 상황 정보 인자가 반영되지 않아 위치적으로 또는 중계노드로 적당하지 않은 노드들이 확률분포에 포함되어 헤드노드로 선택 되는 경우가 발생한다. 따라서 본 논문에서는 기존의 LEACH 기반에서 계층적인 클러스터 구조의 토폴로지로부터 헤드 노드를 선택함에 있어 인접한 노드와의 위치상황 정보인자 및 잔존에너지의 상황정보를 이용하는 ECOPS 알고리즘을 제안 한다. 제안된 ECOPS 알고리즘은 헤드 노드 교체 상황에서 후보 헤드노드 중 최적의 효율적인 에너지 보존 경로를 가지는 멤버 노드가 새로운 헤드노드로 선출됨으로써 전체 노드 수명 및 네트워크의 관리를 향상시키는 것으로 모의실험 결과를 나타내었다.