• Title/Summary/Keyword: ENERGY EFFICIENCY

Search Result 11,101, Processing Time 0.039 seconds

Evaluation of True Metabolizable Energy and the Effect of Corn Distillers Dried Grains with Solubles in the Diets on Broiler Performance and Nutrient Availability (육계에 있어서 옥수수 주정박의 진정 대사 에너지가 측정 및 사료내 첨가가 생산성과 영양소 이용률에 미치는 영향)

  • Hong, E.C.;Chung, W.T.;Kang, G.H.;Park, H.D.;Suh, O.S.;Na, J.C.;Kim, W.;Nho, W.G.;HwangBo, J.
    • Korean Journal of Poultry Science
    • /
    • v.35 no.4
    • /
    • pp.381-389
    • /
    • 2009
  • This study was conducted to investigate the effect of corn distillers dried grains with solubles (CDDGS) in broiler diet on ileal amino acid digestibility and broiler performance. In experiment 1, TMEn of CGGDS ranged from 2,863 to 2,976 kcal/kg and averaged 2,904 kcal/kg on an 86% DM basis. In experiment 2, 192 male Ross broilers (one-day-old) were assigned randomly to 4 dietary treatment groups (12 birds/pen, 4 pens/treatment) as CDDGS levels (0, 6, 12 and 18%) and fed experimental diets for 6 weeks (starter ($0{\sim}2wk$); grower ($2{\sim}4wk$); finisher ($4{\sim}6wk$)). There was no difference in BWG of the chicks. However, feed intake and feed efficiency of chicks fed with non CDDGS groups were better than those of chicks fed with CDDGS fed groups (P<0.05). The amino acid digestibilities of diets containing CDDGS were high for phosphorus but low for lysine, threonine, aspartic acid, cystine and glycine (P<0.05) in the treatments compared to those of the control diet. This study showed that CDDGS has a high ME value and the treatments were low for the ileal amino acid digestibility, but there was no effect on the broiler performances.

Carbon Footprint and Mitigation of Vegetables Produced at Open Fields and Film House using Life Cycle Assessment

  • Lee, Deog Bae;Jung, Sun Chul;So, Kyu Ho;Kim, Gun Yeob;Jeong, Hyun Cheol;Sonn, Yeon Gyu
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.6
    • /
    • pp.457-463
    • /
    • 2014
  • This study was carried out to find out major factors to mitigate carbon emission using Life Cycle Assessment (LCA). System boundary of LCA was confined from sowing to packaging during vegetable production. Input amount of agri-materials was calculated on 2007 Income reference of white radish, chinese cabbage and chive produced at open field and film house published by Rural Development Administration. Domestic data and Ecoinvent data were used for emission factors of each agri-material based on the 1996 IPCC guideline. Carbon footprint of white radish was 0.19 kg $CO_2kg^{-1}$ at open fields, 0.133 kg $CO_2kg^{-1}$ at film house, that of chinese cabbage was 0.22 kg $CO_2kg^{-1}$ at open fields, 0.19 kg $CO_2kg^{-1}$ at film house, and that of chive was 0.66 kg $CO_2kg^{-1}$ at open fields and 1.04 kg $CO_2kg^{-1}$ at film house. The high carbon footprint of chive was related to lower vegetable production and higher fuel usage as compared to white radish and Chinese cabbage. The mean proportion of carbon emission was 35.7% during the manufacturing byproduct fertilizer; white radish at open fields was 50.6%, white radish at film house 13.1%, Chinese cabbage at outdoor 38.4%, Chinese cabbage at film house 34.0%, chive at outdoor 50.6%, and chive at film house 36.0%. Carbon emission, on average, for the step of manufacturing and combustion accounted for 16.1% of the total emission; white radish at open fields was 4.3%, white radish at film house 15.6%, Chinese cabbage at open fields 6.9%, Chinese cabbage at film house 19.0%, chive at open fields 12.5%, and chive at film house 29.1%. On the while, mean proportion of carbon footprint for the step of $N_2O$ emission was 29.2%; white radish at open fields was 39.2%, white radish at film house 41.9%, Chinese cabbage at open fields 34.4%, Chinese cabbage at film house 23.1%, chive at open fields 28.8%, and chive at film house 17.1%. Fertilizer was the primary factor and fuel was the secondary factor for carbon emission among the vegetables of this study. It was suggested to use Heug-To-Ram web-service system, http://soil.rda.go.kr, for the scientific fertilization based on soil testing, and for increase of energy efficiency to produce low carbon vegetable.

DEVELOPMENT OF SAFETY-BASED LEVEL-OF-SERVICE PARAMETERS FOR TWO-WAY STOP-CONTROLLED INTERSECTIONS (무신호 교차로의 안전 -서비스 수준 측정에 관한 연구-)

  • 이수범
    • Proceedings of the KOR-KST Conference
    • /
    • 1996.02a
    • /
    • pp.59-86
    • /
    • 1996
  • Current methods for evaluating unsignalized intersections, and estimating level-of-service (LOS) is determined from efficiency-based criteria such as little or no delay to very long delays. At present, similar procedures to evaluate intersections using safety-based criteria do not exist. The improvement of sight distances at intersections is the most effective way of improving intersection safety. However, a set of procedures is necessary to account for the limitations in current methodology. Such an approach would build upon such methods, but also account for: deficiencies in the current deterministic solution for the determination of intersection sight distances; opportunity for an accident and severity of an accident; and cost-effectiveness of attaining various levels of sight distances. In this research, a model that estimates the degree of safety at two-way stop-controlled intersections is described. Only crossing maneuvers are considered in this study because accidents caused by the crossing maneuvers are the dominate type among intersection accidents. Monte Carlo methods are used to estimate the hazard at an intersection as a function of roadway features and traffic conditions. Driver`s minimum gap acceptance in the crossing vehicles and headway distribution on the major road are used in the crossing vehicles and headway distribution on the major road are used in the model to simulate the real intersectional maneuvers. Other random variables addressed in the model are: traffic speeds; preception-reaction times of both drivers in the crossing vehicles and drivers in oncoming vehicles on the major road; and vehicles on the major roads. The developed model produces the total number of conflicts per year per vehicle and total potential kinetic energy per year per vehicle dissipated during conflicts as measurements of safety at intersections. Based on the results from the developed simulation model, desirable sight distances for various speeds were determined as 350 feet, 450 feet and 550 feet for 40 mph, 50 mph and 60 mph prevailing speed on the major road, respectively. These values are seven to eight percent less than those values recommended by AASHTO. A safety based level-of-service (LOS) is also developed using the results of the simulation model. When the total number of conflicts per vehicle is less than 0.05 at an intersection, the LOS of the intersection is `A' and when the total number of conflicts per vehicle is larger than 0.25 at an intersection, the LOS is `F'. Similarly, when the total hazard per vehicle is less than 350, 000 1b-ft2/sec2, the LOS is `F'. Once evaluation of the current safety at the intersection is complete, a sensitivity analysis can be done by changing one or more input parameters. This will estimate the benefit in terms of time and budget of hazard reduction based upon improving geometric and traffic characteristics at the intersection. This method will also enable traffic engineers in local governments to generate a priority list of intersection improvement projects.

  • PDF

Development of Graphene Nanocomposite Membrane Using Layer-by-layer Technique for Desalination (다층박막적층법을 이용한 담수화용 그래핀 나노복합체 분리막 개발)

  • Yu, Hye-Weon;Song, Jun-Ho;Kim, Chang-Min;Yang, Euntae;Kim, In S.
    • Membrane Journal
    • /
    • v.28 no.1
    • /
    • pp.75-82
    • /
    • 2018
  • Forward osmosis (FO) desalination system has been highlighted to improve the energy efficiency and drive down the carbon footprint of current reverse osmosis (RO) desalination technology. To improve the trade-off between water flux and salt rejection of thin film composite (TFC) desalination membrane, thin film nanocomposite membranes (TFN), in which nanomaterials as a filler are embeded within a polymeric matrix, are being explored to tailor the separation performance and add new functionality to membranes for water purification applications. The objective of this article is to develop a graphene nanocomposite membrane with high performance of water selective permeability (high water flux, high salt rejection, and low reverse solute diffusion) as a next-generation FO desalination membrane. For advances in fabrication of graphene oxide (GO) membranes, layer-by-layer (LBL) technique was used to control the desirable structure, alignment, and chemical functionality that can lead to ultrahigh-permeability membranes due to highly selective transport of water molecules. In this study, the GO nanocomposite membrane fabricated by LBL dip coating method showed high water flux ($J_w/{\Delta}{\pi}=2.51LMH/bar$), water selectivity ($J_w/J_s=8.3L/g$), and salt rejection (99.5%) as well as high stability in aqueous solution and under FO operation condition.

Synthesis of Porous $TiO_2$ Thin Films Using PVC-g-PSSA Graft Copolymer and Their Use in Dye-sensitized Solar Cells (PVC-g-PSSA 가지형 공중합체를 이용한 다공성 $TiO_2$ 박막의 합성 및 염료감응 태양전지 응용)

  • Byun, Su-Jin;Seo, Jin-Ah;Chi, Won-Seok;Shul, Yong-Gun;Kim, Jong-Hak
    • Membrane Journal
    • /
    • v.21 no.2
    • /
    • pp.193-200
    • /
    • 2011
  • An amphiphilic graft copolymer comprising a poly(vinyl chloride) (PVC) backbone and poly (styrene sulfonic acid) (PSSA) side chains (PVC-g-PSSA) was synthesized via atom transfer radical polymerization (ATRP). Mesoporous titanium dioxide $(TiO_2)$ films with crystalline anatase phase were synthesized via a sol-gel process by templating PVC-g-PSSA graft copolymer. Titanium isopropoxide (TTIP), a $TiO_2$ precursor was selectively incorporated into the hydrophilic PSSA domains of the graft copolymer and grew to form mesoporous $TiO_2$ films, as confirmed by scanning electron microscopy (SEM) and X-ray diffraction (XRD) analysis. The performances of dye-sensitized solar cell (DSSC) were systematically investigated by varying spin coating times and the amounts of P25 nanoparticies. The energy conversion efficiency reached up to 2.7% at 100 mW/$cm^2$ upon using quasi-solid-state polymer electrolyte.

A Study on the Integrated Control and Safety Management System for 9% Ni Steel LNG Storage Tank (9% 니켈강재식 LNG 저장탱크용 통합제어안전관리시스템에 관한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.5
    • /
    • pp.13-18
    • /
    • 2010
  • This paper presents the development of an integrated control and safety management system for 9% nickel steel LNG storage tank. The new system added the measuring equipment of pressure, displacement and force compared to the conventional measurement and control system. The measured data has simultaneously been processed by integrating and analyzing with new control equipments and safety management systems. The integrated control and safety management system, which may increase a safety and efficiency of a super-large full containment LNG storage tank, added additional pressure gauges and new displacement/force sensors at the outer side wall and a welding zone of a stiffener and top girder of an inner tank, and the inner side wall of a corner protection tank. The displacement and force sensors may provide failure clues of 9% nickel steel structures such as an inner tank and a corner protection, and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on 9% nickel steel tank fracture even though LNG is leaked until the leak detector, which is placed at the insulation area between an inner tank and a corner protection tank, sends a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force, and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from control systems such as displacement and force of 9% nickel steel tank safety, LNG level and density, cool-down process, leakage, and pressure controls.

A Sludge Collector Selection Model by Life Cycle Cost Analysis (LCC분석에 의한 슬러지수집기 선정 모델)

  • Lee, Seung-Hoon;Woo, Yu-Mi;Lee, Sung-Rak;Koo, Kyo-Jin;Hyun, Chang-Taek;Hong, Tae-Hoon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.6
    • /
    • pp.175-184
    • /
    • 2006
  • This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.

The Study on the Utilization of TPM program Affecting the Productivity Increase (TPM 프로그램의 활동요인이 경영성과에 미치는 효과)

  • Oh, Yon-Woo;Lee, Kee-Chai
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.969-974
    • /
    • 2005
  • TPM program, which is a methodology for improving the management results through the management innovation activity of a company, has been widely introduced in the field of a service industry as well as a manufacturing industry. The main purpose of this study is to present the theoretical model by the relationship between active factors of TPM program and management results for a productivity increase, and to investigate the direct and indirect effects on the management of a company through a parametric study. A questionnaire survey of 300 companies that presently utilize the TPM program has been conducted. In order to verify the validity and the reliability of the contents of the questionnaire survey, a confirmatory factor analysis has been done. A frequency analysis has also been performed to examine the characteristics of the respondent. The factor analysis and the frequency analysis were done by using SAS Ver. 8.2, and the verification of a research model was done by using LISREL Ver. 8.52. The active factors of TPM in the research model consist of 'an independent preservation', 'an individual improvement', 'a planned reservation' and 'an education & training'. Among those active factors, the individual improvement and the education & training significantly influence on the facility efficiency and the organization and personnel management. The organization and personnel management has a greater influence on the management results. Therefore, the education and training for employes is most important for the improvement of the management results through TPM program, and the individual improvement activity is also important.

  • PDF

Vacuum Web-coater with High Speed Surface Modification Equipment for fabrication of 300 mm wide Flexible Copper Clad Laminate (FCCL) (초고속 대면적 표면 처리 장치가 부착된 300 mm 폭 연성 동박적층 필림 제작용 진공 웹 코터)

  • Choi, H.W.;Park, D.H.;Kim, J.H.;Choi, W.K.;Sohn, Y.J.;Song, B.S.;Cho, J.;Kim, Y.S.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.79-90
    • /
    • 2007
  • Prototype of $800{\ell}$ vacuum web coater (Vic Mama) consisting of ion source with low energy less than 250 eV for high speed surface modification and 4 magnetron sputter cathodes was designed and constructed. Its performance was evaluated through fabricating the adhesiveless flexible copper clad laminate (FCCL). Pumping speed was monitored in both upper noncoating zone pumped down by 2 turbo pumps with 2000 l/sec pumping speed and lower surface modification and sputter zone vacuumed by turbo pumps with 450 1/sec and 1300 1/sec pumping speed respectively. Ion current density, plasma density, and uniformity of ion beam current were measured using Faraday cup and the distribution of magnetic field and erosion efficiency of sputter target were also investigated. With the irradiation of ion beams on polyimide (Kapton-E, $38{\mu}m$) at different fluences, the change of wetting angle of the deionized water to polyimide surface and those of surface chemical bonding were analyzed by wetting anglometer and x-ray photoelectron spectroscopy. After investigating the deposition rate of Ni-Cr tie layer and Cu layer was investigated with the variations of roll speed and input power to sputter cathode. FCCL fabricated by sputter and electrodeposition method and characterized in terms of the peel strength, thermal and chemical stability.

A Study on Integrated Control and Safety Management Systems for LNG Membrane Storage Tank (멤브레인식 LNG 저장탱크용 통합제어안전관리시스템에 대한 연구)

  • Kim, Chung-Kyun
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.2
    • /
    • pp.40-46
    • /
    • 2010
  • In this study, the integrated control and safety management system for a super-large LNG membrane storage tank has been presented based on the investigation and analysis of measuring equipments and safety analysis system for a conventional LNG membrane storage tank. The integrated control and safety management system, which may increase a safety and efficiency of a super-large LNG membrane storage tank, added additional pressure gauges and new displacement/force sensors at the steel anchor between an inner tank and a prestressed concrete structure. The displacement and force sensors may provide clues of a membrane panel failure and a LNG leakage from the inner tank. The conventional leak sensor may not provide proper information on the membrane panel fracture even though LNG is leaked until the leak detector, which is placed at the insulation area behind an inner tank, send a warning signal. Thus, the new integrated control and safety management system is to collect and analyze the temperature, pressure, displacement, force and LNG density, which are related to the tank system safety and leakage control from the inner tank. The digital data are also measured from measurement systems such as displacement and force of a membrane panel safety, LNG level and density, cool-down process, leakage, and pressure controls.