• Title/Summary/Keyword: END OF SONG

Search Result 1,056, Processing Time 0.035 seconds

A Study on the Analysis of Export Structure in Jeollabuk-do for the Activation of Saemangeum New Port (새만금신항 활성화를 위한 전라북도 수출구조 분석에 관한 연구)

  • Min-Ju Song
    • Korea Trade Review
    • /
    • v.47 no.4
    • /
    • pp.293-309
    • /
    • 2022
  • The purpose of this paper is to analyze the import and export volume of Jeollabuk-do to establish a plan to activiation Saemangeum New Port. To this end, this study utilized the HHI(Herfindahl-Hirschman Index), LQ(Location Quotient) analysis using the annual data set from the Korea Trade Statistics Promotion Institution between 2015 to 2020. As a result, it has been confirmed that the degree of export volume concentration (HHI (Herfindahl-Hirschman Index)) in Jeollabuk-do has been increasing over the past 5 years. According to results of LQ(Location Quotient) analysis, Brazil had the highest index in the case of exporting countries, and Meat, edible meat offal (HS 2) had the highest index in the case of export items. This paper is meaningful in analyzing the export structure using import and export volumes and proposing a plan to improve the competitiveness of Saemangeum New Port.

Mechanical Characteristics of Reinforced Soil(I) -Cement Reinforced Soil- (보강 혼합토의 역학적 특성(I) -시멘트 혼합토-)

  • Song, Chang-Seob;Lim, Seong-Yoon
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.5 no.6
    • /
    • pp.9-13
    • /
    • 2002
  • This study has been performed to investigate the physical and mechanical characteristics of compaction, volume change and compressive strength for reinforced soil mixed with cement. And confirm the reinforcing effects with admixture such as cement. To this end, a series of compaction test and compression test was conducted for clayey soil(CL) and cement reinforced soil. In order to determine proper moisture content and mixing ratio, pilot test was carried out for soil and cement reinforced soil. And the mixing ratio of cement admixture was fixed 3%, 6%, 9% and 12% by the weight of dry soil. As the experimental results, the maximum dry unit weight(${\gamma}_{dmax}$) was increased with the mixing ratio and then shown the peak at 10% reinforced soil, but the optimum moisture content(OMC) and the volume change was decreased with the ratio increase. And the compressive strength volume change was decreased with mixing ratio increased.

An Oscillator and a Mixer for 140-GHz Heterodyne Receiver Front-End based on SiGe HBT Technology

  • Yoon, Daekeun;Song, Kiryong;Kaynak, Mehmet;Tillack, Bernd;Rieh, Jae-Sung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This paper reports a couple of key circuit blocks developed for heterodyne receiver front-ends operating near 140 GHz based on SiGe HBT technology. Firstly, a 123-GHz oscillator was developed based on Colpitts topology, which showed -5 dBm output power and phase noise of -107.34 dBc/Hz at 10 MHz. DC power dissipation was 25.6 mW. Secondly, a 135 GHz mixer was developed based on a modified Gilbert Cell topology, which exhibited a peak conversion gain of 3.6 dB at 1 GHz IF at fixed LO frequency of 134 GHz. DC power dissipation was 3 mW, which mostly comes from the buffer.

Double-Circuit Transmission Lines Fault location Algorithm for Single Line-to-Ground Fault

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.4
    • /
    • pp.434-440
    • /
    • 2007
  • This paper proposes a fault location algorithm for double-circuit transmission lines in the case of single line-to-ground fault. The proposed algorithm requires the voltage and current from the sending end of the transmission line. The fault distance is simply determined by solving a second order polynomial equation which is achieved directly by the analysis of the circuit. In order to testify the performance of the proposed algorithm, several other conventional approaches have been taken out to compare with it. The test results corroborate its superior effectiveness.

Effect of Simulation-based Practice by applying Problem based Learning on Problem Solving Process, Self-confidence in Clinical Performance and Nursing Competence (문제중심학습을 적용한 시뮬레이션 실습이 간호학생의 문제해결과정, 임상수행자신감과 간호수행능력에 미치는 효과)

  • Song, Young A
    • Women's Health Nursing
    • /
    • v.20 no.4
    • /
    • pp.246-254
    • /
    • 2014
  • Purpose: The purpose of this study was to analyze the effectiveness of simulation-based maternity nursing practice by applying problem based learning (PBL) on the problem solving process, self-confidence in clinical performance and nursing competence of nursing students. Methods: This study was one group pre-posttest design, with 123 third year nursing students. Data were collected from March 19 to May 29, 2013 as the students completed their simulation practice class. Students completed a survey about their problem solving process, self-confidence, and nursing competence at the beginning and the end of the class. Results: Students' problem solving process, self-confidence, and nursing competence showed significant improvements after the simulation-based maternity nursing practice. Conclusion: Therefore, it is recommended that current maternity nursing curriculum should be reviewed and improved, and the students should be provided variety of simulation-based education and maternity nursing skills.

Anhydrous Proton Conducting Polymer Electrolytes Based on Poly(phosphonic acid)s and Oligomeric Triazole Compounds

  • Song, Myeong-Soo;Lee, Sung-Il;Bingoel Bahar;Meyer Wolfgang H.;Yoon, Do-Y.
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.272-272
    • /
    • 2006
  • In recent years, water-free polymer electrolyte membranes are attracting serious attention due to the possibility of the fuel cell operation at intermediate temperatures ($100{\sim}200^{\circ}C$). It was reported that phosphonic acids have proton conductivity under anhydrous conditions and in particular, relatively high proton conductivity could be obtained from the composite materials with heterocycles such as imidazole, pyrazole, etc. In this work, styrene based polymers, poly((4-vinylbenzyloxy)alkylphosphonic acid), which have phophonic acid group at the end of alkyl chain was synthesized. These polymers were analyzed in terms of thermal stability and proton conductivity. Additionally, cyclic oligosiloxanes tethered with triazole were prepared and analyzed.

  • PDF

Deubiquitinase USP35 as a novel mitotic regulator via maintenance of Aurora B stability

  • Park, Jinyoung;Song, Eun Joo
    • BMB Reports
    • /
    • v.51 no.6
    • /
    • pp.261-262
    • /
    • 2018
  • Aurora B is an important kinase involved in dynamic cellular events in mitosis. Aurora B activity is controlled by several post-translational modifications (PTMs). Among them, E3 ubiquitin ligase-mediated ubiquitination plays crucial roles in controlling the relocation and degradation of Aurora B. Aurora B, ubiquitinated by different E3 ligases, moves to the exact site for its mitotic function during metaphase-anaphase transition and is then degraded for cell cycle progression at the end of mitosis. However, how the stability of Aurora B is maintained until its degradation has been poorly understood. Recently, we have found that USP35 acts as a deubiquitinating enzyme (DUB) for Aurora B and affects its stability during cell division, thus being involved in the regulation of mitosis. In this review, we discuss the USP35-mediated deubiquitination of Aurora B and the regulation of mitotic progression by USP35.

Influences of Mach Number and Flow Incidence on Aerodynamic Losses of Steam Turbine Blade

  • Yoo, Seok-Jae;Ng, Wing Fai Ng
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.456-465
    • /
    • 2000
  • An experiment was conducted to investigate the aerodynamic losses of high pressure steam turbine nozzle (526A) subjected to a large range of incident angles ($-34^{\circ}\;to\;26^{\circ}$) and exit Mach numbers (0.6 and 1.15). Measurements included downstream Pitot probe traverses, upstream total pressure, and end wall static pressures. Flow visualization techniques such as shadowgraph and color oil flow visualization were performed to complement the measured data. When the exit Mach number for nozzles increased from 0.9 to 1.1 the total pressure loss coefficient increased by a factor of 7 as compared to the total pressure losses measured at subsonic conditions ($M_2<0.9$). For the range of incidence tested, the effect of flow incidence on the total pressure losses is less pronounced. Based on the shadowgraphs taken during the experiment, it' s believed that the large increase in losses at transonic conditions is due to strong shock/ boundary layer interaction that may lead to flow separation on the blade suction surface.

  • PDF

RELIABILITY TEST DESIGN Of REMANUFACTURED STEERING GEAR OIL SEAL

  • Gafurov, Alisher;Jung, Do-Hyun;Song, Hyun-Seok
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2011.06a
    • /
    • pp.265-270
    • /
    • 2011
  • This paper describes a reliability/durability test of the remanufactured steering gear units. There used to be government restrictions to remanufacture certain types of automotive components regarding safety of passengers. Nevertheless, scientific approach to sustainability and remanufacturing process provided solid evidence of highly beneficial sides of reusing the products. Failure mode analysis of the steering gear unit is performed and main failure is found out. The unit is remanufactured by fixing the failure and its quality is assessed through designing a new sequence of loading events. Oil leakage is witnessed as a possible failure and its volume is measured. Conclusions based on laboratory condition durability test are given at the end.

  • PDF

A Study on the measurement and Method of Partial Discharge in High Voltage CV Cable (고압 CV 케이블에서의 부분방전 측정과 위치검출 방법에 관한 연구)

  • Song Jae-Yong;Seo Hwang-Dong;Park Dae-Won;Kil Gyung-Suk;Han Moon-Sup;Jang Dong-Wook
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.867-872
    • /
    • 2005
  • This paper describes the measurement and location method of partial discharges in high voltage CV cables. Coupling capacitors were used to detect partial discharge signal. Impedance characteristic of the coupling circuit and an amplifier with a high Common Mode Rejection Ratio(CMRR) were studied to improve sensitivity of the circuit. From the calibration experiment, the sensitivity of the partial discharge detection circuit was about 100pC. Also, we confirmed that the location of partial discharges in cables can be estimated by calculation of time difference between the first pulse and the second one reflected from the other end of the cable.