• Title/Summary/Keyword: EMTP-ATPDraw

Search Result 62, Processing Time 0.037 seconds

Analysis of Common Grounding Effect during the Transient State in Underground Transmission and Distribution Systems (지중송배전계통에서 과도상태시 공통접지의 영향 분석)

  • Lim, Kwang-Sik;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.191-197
    • /
    • 2008
  • This paper describes the effect of transient state in underground transmission and distribution lines installed together in the same tunnel. Two systems installed in the same tunnel are operated by the common grounding. This paper analyzed that how much one of the two kinds of systems influences the other systems during the transient state by EMTP/ATPDraw. Single line-to-ground fault and lightning surge were selected in transient state condition. These cases were simulated variously according to the variation of common grounding magnitude, fault location and lightning surge magnitude. It is evaluated that the analyzed results will be used for establishment and operating materials of common grounding in the same tunnel.

A Study on Recloser Operation According to Recovery Characteristics of Superconducting Fault Current Limiter (초전도 한류기 회복특성에 따른 재폐로 차단기 동작 연구)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.379-380
    • /
    • 2008
  • For proper application and operation of a SFCL(Superconducting Fault Current Limiter), the prior investigation of fundamental characteristics and its effects to the distribution systems are needed. In this paper, the resistive type SFCL and recloser were developed by using EMTP/ATPDraw and MODELS language. To analyze the effect of recovery characteristics of SFCL according to recloser operation in distribution systems, case studies have been simulated and investigated.

  • PDF

Asymmetry Components Reduction using Superconducting Fault Current Limiter Operation in Transient Period (비대칭 고장전류 저감을 위한 초전도 한류기 동작 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.381-382
    • /
    • 2008
  • This paper presents a novel scheme for reducing an asymmetry current with SFCL (Superconducting Fault Current Limiter) operation during transient period, when a fault occurs in power systems. The main idea is installation an auxiliary SFCL with characteristics, which reduces the asymmetry fault current in first half cycle before the operating of main SFCL. For proper activities of SFCLs, the principle of asymmetry current nature is reviewed. A scheme of asymmetry components reduction with SFCL is then explained. The EMTP/ATPDraw model of SFCLs using MODELS language developed and simulated to verify the performance and effectiveness.

  • PDF

Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge (뇌서지로 인한 피뢰기 열화시 과도상태 분석)

  • Lim, Sung-Yong;Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

An Algorithm for Electric Vehicle Charging in PV integrated Power System (태양광 발전 연계 계통에서의 전기자동차 충전 알고리즘)

  • Lee, Woong-Hee;Kim, Jun-Hyuk;Lee, Soon-Jeong;Kim, Chul-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.341-342
    • /
    • 2015
  • Attention has been focused on how to charge an electric vehicle in accordance with the increase of interest in the electric vehicle in recent years. The charging of an electric vehicle with a solar power is way to increase the stability of the grid and to supplement the grid power demand. In this paper, the EMTP / ATPDraw presents a method of charging an electric vehicle in connection to the grid and the solar power system, and analyze the trends in supply power from the solar power system according to changes in temperature and irradiation.

  • PDF

System Effects by Operation Characteristics of Superconducting Fault Current Limiters in Distribution Systems (배전계통 초전도 한류기 동작특성에 따른 계통 영향 분석)

  • Rhee, Sang-Bong;Kim, Chul-Hwan;Kim, Kyu-Ho;Kim, Jae-Chul;Hyun, Ok-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1135-1140
    • /
    • 2008
  • Superconducting fault current limiters (SFCL) have been progressing due to the development of superconducting technology. The resistor type SFCL is one of the promising current limiting devices in power system for its effective operation. For proper application and operation of a SFCL, the prior investigation of fundamental characteristics and its effects to the distribution systems are needed. The most important current limiting behavior of a SFCL is dominated by quenching and recovery characteristics. In this paper, the resistive type SFCL was developed by using EMTP/ATPDraw and MODELS language. The operating characteristics and current limiting behaviors of the SFCL in distribution systems have been simulated and investigated.

A Study on the Characteristic and Rising Cause of Sheath Circulating Current by Analysis and Measurement (해석 및 측정을 통한 시스순환전류 특성 및 상승원인 검토)

  • Gang, Ji-Won;Yang, Hae-Won
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.10
    • /
    • pp.525-533
    • /
    • 2002
  • It is common to install multiple lines in the same route. Recently, excessive sheath circulating current was partially measured in underground cable systems of KEPCO. Especially, the installation type, unbalance section length between joint boxes and zero sequence current by distribution cable have an effect on the rising of sheath circulating current in the underground transmission system. If excessive current flows in sheath, sheath loss which is reduced the transmission capacity is produced. This paper describes the relation analysis of sheath circulating current and burying types. And also, a detailed analysis on rising cause and characteristic of sheath circulating current by considering various unbalanced conditions presents using analysis and measurement regarding cable systems which have the problem of excessive sheath circulation current.

Protection of Insulation Joint Box and Analysis of Overvoltage in Underground Power Cable Systems (지중송전케이블계통에서 절연통 보호대책 및 과전압 해석)

  • Hong, Dong-Suk;Jin, Hye-Young;Jung, Che-Kyun;Lee, Jong-Beom;Cho, Han-Ku
    • Proceedings of the KIEE Conference
    • /
    • 2001.11b
    • /
    • pp.380-382
    • /
    • 2001
  • This paper describes the protection of insulation joint box in combined transmission line which is connected with the 154kV underground power cables. An actual power cable system was selected to establish modeling and to analyze. Modeling was established in EMTP and ATPDraw. Simulation was carried out according to the buried method of cable and connection method of CCPU. Results presented in this paper will be applied to another power cable systems.

  • PDF

A Study on the Optimal Position of Lightning Arrester on Joint Operation of Neutral Wire and Overhead Grounding Wire through Lightning Surge Analysis in Combined Distribution System (혼합배전계통에서 뇌과전압 해석을 통한 중성선과 가공지선 혼용 운전시 적정 피뢰기 위치에 관한 연구)

  • Jeong, Seok-San;Jang, Hwa-Youn;An, Chun-Yong;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.535-536
    • /
    • 2011
  • This paper studies the validity about a joint operation of neutral wire and overhead grounding wire in combined distribution systems. The overhead grounding wire and neutral wire are currently installed separately and grounded by common. However there is no any ineffectiveness or electrical problem in case of the proposed system, such system can be operated at real distribution system. Therefore this paper describes the suitability of a joint operation through lightning surge analysis on combined distribution systems and analyzes the optimal position of lightning arrester on joint operation of neutral wire and overhead grounding wire. Lightning surge analysis is carried out by EMTP/ATPDraw to obtain the overvoltage of overhead line and underground cable in various conditions such as location and current types of lightning stroke. Over voltage gained by the analysis show that the insulation strength of the joint operation case is not stable compare with the current operation case.

  • PDF

Open-Phase Condition Detecting System for Transformer Connected Power Line in Nuclear Power Plant (원자력발전소 변압기 연결 선로 결상 검출 시스템)

  • Ha, Che-Wung;Lee, Do-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.254-259
    • /
    • 2015
  • On January 30, 2012 an auxiliary component of Byron Unit 2 was tripped on bus under voltage. The cause of the event was the failure of the C-phase insulator track for the Unit 2 station auxiliary transformer(SAT) revenue metering transformer. In addition to this event, other events have occurred at other plants resulting in an open-phase condition.[1] Therefore, Nuclear Regulatory Commission(NRC) has requested that not only nuclear power plant(NPP) operating company but also its Design Certification(DC) applicant have to prepare open-phase detecting system in their operating plants and design document. In this paper, various open-phase conditions are simulated in NPP using Electromagnetic Transient Program(EMTP) and Atpdraw, and open-phase condition detecting system is proposed for Main Transformer(MT), Unit Auxiliary Transformer(UAT) and SAT connected power line in NPP.