• Title/Summary/Keyword: EMI Test

Search Result 143, Processing Time 0.031 seconds

A Study on Optimal Deployment for Improvement of EMI between MOSCOS and ES DF Antenna on a Surface Ship (수상함 MOSCOS와 ES 방향탐지 안테나간의 전자기 간섭 개선을 위한 최적배치 연구)

  • Chang, Hoseong;Son, Yoonjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.197-205
    • /
    • 2017
  • During the sea trial, we discovered EMI between MOSCOS and ES DF antenna. CW emitted by MOSCOS raised the threshold level of ES DF antenna. As a result, direction finding rate of ES has been decreased. This is a study for the improvement of EMI between the antennas mounted on a surface ship. An analysis is accomplished for MOSCOS, ES DF antenna and Jamming transmitter. This paper presents the method how to solve EMI based on the measurements and calculations about the ES DF antenna receiving level, MOSCOS radiation pattern and Jamming transmitter thermal noise. The test was performed with optimal deployment of MOSCOS on a surface ship. After changing the position of MOSCOS, EMI has been decreased significantly.

Performance Evaluation of the New Smart Passive Control Device using Shaking Table Test (진동대 실험을 통한 신개념 스마트 수동제진장치의 제진성능 평가)

  • Jang, Dong-Doo;Jung, Hyung-Jo;Moon, Seok-Jun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2010
  • This paper presents the vibration control performance of the smart passive control system to suppress the undesired vibration of the structure subjected to the earthquake loadings. Smart passive control system is the MR damper-based control system augmented with electromagnetic induction(EMI) device which consists of permanent magnets and solenoid coils. According to the Faraday's law of electromagnetic induction, an EMI device produces electrical energy from the mechanical energy due to the reciprocal motions of the structure and provide it to the MR damper. The smart passive control system can be the simple and easy to implement and maintain control system by replacing the feedback control system including sensors, controllers and external power sources of the conventional MR damper-based semiactive control system with the EMI device. The control performance of the smart passive control system is evaluated through the set of shaking table test considering the various historical earthquake loadings.

A study of EMI Prevention and test method for VVVF Inverter electric car (철도차랑용 VVVF인버터의 노이즈 대책과 유도장에 시험)

  • Kim, Gil-Dong;Han, Young-Jae;Park, Hyun-Jun;Baek, Jong-Hyen
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1442-1444
    • /
    • 2000
  • High speed switching action of PWM inverter is being further advanced for electric motor vehicles. Due to this high speed switching action, extensive high frequency electromagnetic noise emerges. Therefore counterm-easures against electromagnetic interference of electric motor vehicles become increasingly important. This paper describes the theory and countermeasure principle of EMI prevention and EMI test method for Korean Standard EMU.

  • PDF

Design of a Biconical Antenna with Cylindrical Loads for EMI Test Site Validation above 1 GHz

  • Kong, Sung-Sik;Choi, Jae-Hoon
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, a biconical type antenna is proposed for EMI test site validation above 1 GHz. To achieve broadband and omni-directional radiation patterns required by international standard(CISPR), the proposed antenna consists of general bicones with cylindrical loads and adopts side feeding method to minimize the influence on H-plane pattern due to feeding cable, balun, and connector. The radiation patterns of the fabricated antenna are measured and the results are compared with CISPR criteria and commercial antenna in our interest frequencies. Although the proposed antenna has a few problems in frequency range of 1 GHz to 2 GHz, it has relatively better performance than commercial antenna.

Pspice ABM MOSFET Model for Conducted EMI Analysis (전도 전자파 장애 분석을 위한 Pspice ABM MOSFET 모델)

  • Lee, J.H.;Lee, D.Y.;Cho, B.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.1876-1878
    • /
    • 1998
  • For an analysis and simulation of the conducted EMI of switching converters, an accurate simulation model for MOSFET is needed. This paper presents a new modeling approach, which incorporates DC output characteristics and AC dynamics especially the parasitic capacitances. It uses Pspice ABM(Analog Behavioral Model) and the MOSFET parameters can be obtained from the Data sheet in the frequency range of interest for EMI analysis. The model verified with an experimental setup and the EMI for a test converter is analyzed with respect to the MOSFET switching waveforms.

  • PDF

Electric Vehicle Wireless Charging Control Module EMI Radiated Noise Reduction Design Study (전기차 무선충전컨트롤 모듈 EMI 방사성 잡음 저감에 관한 설계 연구)

  • Seungmo Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.104-108
    • /
    • 2023
  • Because of recent expansion of the electric car market. it is highly growing that should be supplemented its performance and safely issue. The EMI problem due to the interlocking of electrical components that causes various safety problems such as fire in electric vehicles is emerging every time. We strive to achieve optimal charging efficiency by combining various technologies and reduce radioactive noise among the EMI noise of a weirless charging control module, one of the important parts of an electric vehicle was designed and tested. In order to analyze the EMI problems occurring in the wireless charging control module, the optimized wireless charging control module by applying the optimization design technology by learning the accumulated test data for critical factors by utilizing the Python-based script function in the Ansys simulation tool. It showed an EMI noise improvement effect of 25 dBu V/m compared to the charge control module. These results not only contribute to the development of a more stable and reliable weirless charging function in electric vehicles, but also increase the usability and efficiency of electric vehicles. This allows electric vehicles to be more usable and efficient, making them an environmentally friendly alternative.

Serviceability Assessment of a K-AGT Test Bed Bridge Using FBG Sensors (광섬유 센서를 이용한 경량전철 교량의 사용성 평가)

  • Kang, Dong-Hoon;Chung, Won-Seok;Kim, Hyun-Min;Yeo, In-Ho
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.305-312
    • /
    • 2007
  • Among many types of light rail transits (LRT), the rubber-tired automated guide-way transit (AGT) is prevalent in many countries due to its advantages such as good acceleration/deceleration performance, high climb capacity, and reduction of noise and vibration. However, AGT is generally powered by high-voltage electric power feeding system and it may cause electromagnetic interference (EMI) to measurement sensors. The fiber optic sensor system is free from EMI and has been successfully applied in many applications of civil engineering. Especially, fiber Bragg grating (FBG) sensors are the most widely used because of their excellent multiplexing capabilities. This paper investigates a prestressed concrete girder bridge in the Korean AGT test track using FBG based sensors to monitor the dynamic response at various vehicle speeds. The serviceability requirements provided in the specification are also compared against the measured results. The results show that the measured data from FBG based sensors are free from EMI though electric sensors are not, especially in the case of electric strain gauge. It is expected that the FBG sensing system can be effectively applied to the LRT railway bridges that suffered from EMI.

Electrochemical Characteristics of Supercapacitor Using Ionic Liquid Electrolyte (Supercapacitor용 이온성 액체 전해질의 전기화학적 특성)

  • Kim, Sang-Gil;Hwang, Gab-Jin;Kim, Jae-Chul;Ryu, Cheol-Hwi
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.4
    • /
    • pp.201-207
    • /
    • 2011
  • Supercapacitor has been studied actively as one of the most promising electrochemical energy storage system for a wide range of applications. To increase the energy density of supercapacitor, the introduction of ionic liquids is required. In this study, two types of EMI-$BF_4$ based on quaternary imidazolium salt were prepared with quaternary reaction and anion exchange. The structural characterization and thermal stability were analyzed by nuclear magnetic resonance($^1H$-NMR) and thermogravimetric analysis(TGA), respectively. Thermal stability of the EMI-$BF_4$ using TGA confirmed that, after heat treatment, the decomposition temperature of EMI-$BF_4$ was increased. Supercapacitors were fabricated with synthesized and commercial ionic liquids, and charge/discharge characteristics were also investigated. The capacity of supercapacitor, for synthesized and commercial EMI-$BF_4$ were determined to be 0.067 F and 0.073 F respectively, by means of charge/discharge test.

EMI database analysis focusing on relationship between density and mechanical properties of sedimentary rocks

  • Burkhardt, Michael;Kim, Eunhye;Nelson, Priscilla P.
    • Geomechanics and Engineering
    • /
    • v.14 no.5
    • /
    • pp.491-498
    • /
    • 2018
  • The Earth Mechanics Institute (EMI) was established at the Colorado School of Mines (CSM) in 1974 to develop innovations in rock mechanics research and education. During the last four decades, extensive rock mechanics research has been conducted at the EMI. Results from uniaxial compressive strength (UCS), Brazilian tensile strength (BTS), point load index (PLI), punch penetration (PP), and many other types of tests have been recorded in a database that has been unexamined for research purposes. The EMI database includes over 20,000 tests from over 1,000 different projects including mining and underground construction, and analysis of this database to identify relationships has been started with preliminary results reported here. Overall, statistically significant correlations are identified between bulk density and mechanical strength properties through UCS, BTS, PLI, and PP testing of sedimentary, igneous, and metamorphic rocks. In this paper, bulk density is considered as a surrogate metric that reflects both mineralogy and porosity. From this analysis, sedimentary rocks show the strongest correlation between the UCS and bulk density, whereas metamorphic rocks exhibit the strongest correlation between UCS and PP. Data trends in the EMI database also reveal a linear relationship between UCS and BTS tests. For the singular case of rock coral, the database permits correlations between bulk density of the core versus the deposition depth and porosity. The EMI database will continue under analysis, and will provide additional insightful and comprehensive understanding of the variation and predictability of rock mechanical strength properties and density. This knowledge will contribute significantly toward the increasingly safe and cost-effective geostructures and construction.

Limits of Fully Anechoic Room for Radiated Disturbance Using Correlation Factor (야외시험장과 전자파 완전 무반사실과의 상관계수를 이용한 완전 무반사실의 허용 기준 제안)

  • Lee, Soon-Yong;Chung, Yeon-Choon;Choi, Jea-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1401-1411
    • /
    • 2010
  • In this paper, we suggested the tolerance limits of FAR(Fully Anechoic Room) using correlation factor between OATS(Open area Test Site) to measure EMI(Electromagnetic Interference) and FAR to measure EMS(Electromagnetic Susceptibility). FAR Project(SMT4-CT96-2133), CISPR/A/665/DTR, and CISPR A/665/DTR documents are analyzed and theoretical correlation factor based on the documents and theoretical equations is drawn. To obtain the experimental correlation factor, EUT(Equipment Under Test) is fabricated as well as measured at the 10 m distance OATS and in the 3 m distance FAR. Also, to suggest the tolerance limits of EUT with multi sources, radiation theory for electric and magnetic dipoles is programmed. We drew the correlation factor for EUT with multi sources through the programs. As the tolerance limits of FAR is newly defined, It can be used alternative test site for OATS to measure EMI, efficiently.