• Title/Summary/Keyword: EMI Test

Search Result 144, Processing Time 0.037 seconds

Frequency Spectrum Analysis of Corona Discharge as Electrode Structures (전극 구조에 따른 코로나 방전의 주파수 스펙트럼 분석)

  • Jung, Kwang-Seok;Kim, Sun-Jae;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.118-118
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves which is generated by corona discharges as a basic study to develop a on-line diagnostic technique for power facilities installed in a closed-switchboard. Five types of electrode system were arranged to simulate corona discharge. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. These results showed that the frequency spectrum of corona discharges exists widely in ranges from 30 to 1,000 [MHz].

  • PDF

Diagnostic Technique of a Switchboard by Frequency Analysis of Radiated Electromagnetic Wave (방사전자파의 주파수분석에 의한 배전반 진단기술)

  • Park, Dae-Won;Kim, Sun-Jae;Jung, Kwang-Seok;Kil, Gyung-Suk;Jo, Eun-Je
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.41-45
    • /
    • 2010
  • In this paper, we analyzed the frequency spectrum of radiated electromagnetic waves generated by series arc- and corona- discharges as a basic study to develop an online diagnostic technique for power facilities installed inside switchboards. To simulate corona and series arc discharges, an arc generator specified in UL1699 and a corona generator were fabricated. The experiment was carried out in an electromagnetic shielding room, and the measurement system consists of an Ultra Log Antenna and an EMI Test Receiver. The frequency spectrum exists in ranges from 30 to 500 [MHz] for series arc discharge and 30 [MHz] to 2 [GHz] depending on defects for corona discharge. The peak frequency of series arc discharge and corona were 40 [MHz], 80 [MHz] and 35 [MHz]~160 [MHz], respectively.

  • PDF

Measurements and Analysis of Electromagnetic Shielding Effectiveness of PDP TV Screen Filters (PDP TV Screen Filter의 Shielding Effectiveness 측정 및 분석)

  • Park, Gyu-Bok;Kim, Yoon-Jung;Kim, Young-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.47-53
    • /
    • 2003
  • Screen filter of PDP TV plays an important role in satisfying the EMI/EMC specifications. Two types of filters, the mesh type and the sputter type, are used in PDP TVs, and this paper presents measurement results of the shielding effectiveness (SE) in the frequency range from 50MHz to 1GHz. Two methods were used for the measurement, one using network analyzer (NA) in an open area test site(OATS), and the other using the screen room. The overall conclusion is that the shielding effectiveness of the screen filter is related to the surface resistance of the screen filter. The mesh type screen filters are superior to the sputter types in the shielding effectiveness, which is varying with the frequency.

  • PDF

전원단자 방해파 전력측정의 불확실성 개선

  • Shin, Kook-Sun;Choi, Seong-Ho;Kim, Nam;Park, Seong-Wook
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.1
    • /
    • pp.81-88
    • /
    • 2003
  • CISPR has published the limits on the noises emitting from power lines and signal lines. But different measurement environment and measurement methods are used in every countries. This difference causes much confusion in understanding the results measured by different test laboratories. In this paper, we measure EMI noise using the absorbing clamp method that takes short measurement time and is described in CISPR 13, 14-1, 16-2. We analyze the cause of the difference of measurement results and propose the method for improving the uncertainty

Analysis of Electro-magnetic Interference Noise for Eco-friendly Vehicle (친환경 자동차의 전자파 방사 노이즈 특성 분석)

  • Kim, Hae-Sung;Yong, Boo-Joong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.76-81
    • /
    • 2011
  • Fossil fuel, the energy source of internal combustion engine automobiles, is limited in resource and has caused environmental issues for decades. Accordingly, automobile manufacturers from many countries around the world are developing or producing eco-friendly vehicles that utilize alternative sources of energy. These vehicles are equipped with many electronic and electrical components which operate on high voltage and/or large current that were not used in conventional combustion engine automobiles. In this paper, in order to analyze the electro-magnetic interference noise, electric vehicles and fuel cell electric vehicles are tested under the guidelines of KMVSS (Korean Motor Vehicle Safety Standards) as well as under test modes that are not stipulated under the guidelines.

FDTD Analysis of the Absorption Characteristics for Grid Ferrite Electromagnetic Wave Absorber (FDTD를 이용한 격자형 페라이트 전파흡수체 특성 해석)

  • 이재용;정연춘;명노훈
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.483-490
    • /
    • 1998
  • The reflectivity of a grid ferrite electromagnetic wave absorber is analyzed using finite difference time domain (FDTD) method, which is usually used in anechoic chambers for EMI / EMS test. The frequency dispersive characteristics of ferrite medium and its boundary condition are modeled using magnetic flux in addition to E- and H-fields. By applying Floquets theorem, FDTD analysis of the grid ferrite absorber with periodic infinite array is simplified as a unit cell problem. The method of homogenization which is mainly utilized in the calculation of absorber reflectivity as a low frequency technique takes only into account volume fraction of the unit cell of the absorber except for the structure of medium geometry. However, the presented method in this paper can analyze the geometry effect of the unit cell with its medium characteristics up to high frequency region.

  • PDF

BITSE Filter Wheel Assembly using a Piezo-ceramic module

  • Yang, Heesu;Choi, Seong-hwan;Kim, Jihun;Park, Jongyeob;Baek, Jihye;Kim, Yeon-Han;Newmark, Jeffrey;Gopalswamy, Nat
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.44 no.2
    • /
    • pp.57.3-57.3
    • /
    • 2019
  • Space applications of the motion have been served with DC motors for decades. But their functionality with a gearbox and lubricants and their weights are always an issue for its application. A piezo-motor has an advantage on the direct driving with higher accuracy, smaller size, and no-EMI. We use the piezo-motor to rotate a filter wheel directly in a balloon-borne coronagraph launched on September 2019. The piezo-motor works well in a temperature range from -10 to 40 Celsius with high reliability and high positioning / tilt accuracy (~0.1degree) with a photo-encoder. We verify its functionality for 7 days. In this talk, we report the design, test processes of the filter wheel including its balloon flight result.

  • PDF

Performance and Reliability Characteristics of the Free Piston Free Displacer Stirling Cryocooler

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Koh, Deuk-Yong;Kim, Yang-Hoon
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.46-51
    • /
    • 2004
  • This paper presents the results of a series of performance and reliability tests for the Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate specification for the performance and reliability. FPFD Stirling cryocooler is currently under development for cooling infrared detector. Manufactured Stirling cryocooler delivers approximately 0.9W cooling at 80K for 30W∼40W of input power. It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$. Performance characteristics for the vibration, acoustic noise, EMI and leak rate of the Stirling cryocooler are evaluated. We performed low and high temperature keeping test from -32$^{\circ}C$ to +52$^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity is determined as a function of the temperatures at the compressor, hot end and cold tip at the expander. Finally, we describe the experimental facility for the MTTF evaluation and some typical results of the Stirling cryocooler.

A study on development of Power Cable countermeasuring EFT IEC801-4 (EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구)

  • 김형근;배대환;민경찬;김동일
    • Journal of the Korean Institute of Navigation
    • /
    • v.19 no.2
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF

A Study on the Tasks 119 Fire Service -The Two City of Fire & Disaster Management Department- (119 구급대원들의 업무에 관한 연구 -2개 광역시 소방구급대를 중심으로-)

  • Kim, Mi Sook;Yeo, Jin Dong
    • The Korean Journal of Health Service Management
    • /
    • v.1 no.1
    • /
    • pp.90-109
    • /
    • 2007
  • This Study aims to examine the relative importants of various tasks of EMT and to examine knowledge level and problems associated with AED. It is based on the survey of paramedics and rescurers. The instrument by Hoe Sum Lim(1999) was used. as the questionaire for this research. The collected data were analyzed by means of $x^2$ test, t-test, and measured by percents. The results for this study were follows: 1) Among the tasks of EMI, "Basic Life Support" were rated as the most important, followed by "O2 supply" and foreign-body removal from mouth. 2) Some of the lower level of importance in task were Intubation, IV, dextrose infusion of Hypoglycemia, NTG S/L for chest pain, hydration for fluid therapy, brochodilator IV for Bronchial Asthma. 3) Some of the lower level of importance in task were apply of MAST, Vital Sign check and administration of traction & spine immobilization & air splint. 4) The most important reason that the used of AED is delayed is "unclear boundary of treatment directed by medical control".

  • PDF