• Title/Summary/Keyword: EMG-measurement

Search Result 175, Processing Time 0.026 seconds

Usefulness of Myotonometer for Measurement of Tissue Compliance on Medialis Gastrocnemius in Patients with Stroke (뇌졸중 환자에서 내측 비복근의 조직탄성 측정을 위한 Myotonometer의 유용성)

  • Bae, Sea-Hyun;Lee, Jeong-In;Kim, Kyung-Yoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.3
    • /
    • pp.1129-1137
    • /
    • 2012
  • The aim of this study was to find useful parameters of the between myotonometer and surface electromyography(sEMG) on the medialis gastrocnemius of stroke patients and investigate between these parameters and modified Ashworth scale(MAS) relationship. 5 years clinical experience physical therapist using the Modified Ashworth Scale(MAS) was selected 15 patients with ankle spasticity and divided randomly MAS2, MAS3, MAS4 groups. Myotonometer and sEMG was measured during relaxed and maximum voluntary contractions of the gastrocnemius muscle. The results of this study, the higher MAS score was the lowered the relaxation and contraction state tissue compliance and muscle activity and in the correlation analysis the higher MAS score during voluntary contraction in the cylinder receiving low-intensity correlation could see that increased than relaxation. Therefore, the myotonometer is a useful clinical and research tool with spasticity muscle and can provide objective quantitative data about the efficacy of physical therapy interventions.

Changes in Electromyogram Signals from the Tibialis Anterior Muscle Resulting from Maximal Voluntary Contraction Exercise (최대수의적 수축훈련에 의한 앞 정강근의 근전도 신호의 변화)

  • Song, Su-Young;Hwang, Ki-Kyeong;Kim, Moon-Jeong;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.9 no.2
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose : This study aims to examine changes in electromyogram (EMG) signals detected from the tibialis anterior muscle during repetitive contraction exercises in normal female adults. Methods : The subjects of this study were 10 normal adult females without any musculoskeletal or nervous system disorders. A total of 30 contractions were made repetitively with maximal voluntary contraction exercise for six seconds and a resting time for three seconds. Changes in muscle contractions were measured using dynamometer and EMG signals such as root mean square (RMS), integrated EMG (IEMG), and median frequency (MDF). Results : The result of measurement showed no significant differences in IEMG and RMS in accordance with the increase in the number of contractions. MVIC and MDF showed significant differences in accordance with the increase in the number of contractions (p<0.05). Conclusion : This study demonstrated that repetitive tibialis anterior muscle contraction resulted in a significantly different MVIC and MDF but no significant differences in IEMG and RMS. Therefore, compared to other lower leg muscles, the tibialis anterior muscle is a low-frequency muscle and therefore electrophysiological characteristics of the muscle should be considered in different exercise methods.

A Comparison of EEG and Forearms EMG Activity depend on the Type of Smartphone when Inputting Text Messages (스마트폰 유형에 따른 문자 입력 시 뇌파 및 아래팔 근활성도 비교)

  • Lee, Hyoungsoo;Go, Gyeongjin;Kim, Jinwon;Park, Songyi;Park, Jiseon;Park, Jinri;Seok, Hyer;Yang, Gureum;Yang, Sieun;Yun, Gwangoh
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.2 no.2
    • /
    • pp.79-88
    • /
    • 2014
  • Purpose: This study investigated the relationship between smartphone addiction propensities and compare muscle activity of the forearms and brain wave depend on the type of smartphone when inputting text messages. Method: We used an EMG to measure the change in muscle activity by attaching pads to the four muscles in both forearms of all 16 participants. We simultaneously conducted EEG measurements by observing the changes in alpha and beta waves recorded from electrode attached to both ears and the forehead of the participants. The participants had to input a given text using three different types of smartphones for ten minutes each. Result: The comparison of the EMG when inputting text involved a one way analysis of variance and the results showed that the iPad3 was highest for muscle activity followed by GALAXY Note2 and iPhone4. For EEG measurement, a one way analysis of variance was also used and the results showed iPhone4 was higest followed by GALAXY Note2 and finally iPad3 for EEG stress score. Conclusion: The results are thought to be used as reference data for smart phone users.

Changes of Muscle Activity and Cephalometric Variables Related to Head Posture (두부자세에 따른 근활성과 측모두부방사선계측치의 변화에 관한 연구)

  • Kim, Byung-Wook;Han, Kyung-Soo
    • Journal of Oral Medicine and Pain
    • /
    • v.24 no.2
    • /
    • pp.189-206
    • /
    • 1999
  • This study was performed to investigate the factors affecting muscle activity and cephalometric variables according to change of head postures. For this study, 150 patients with temporomandibular disorders and 80 dental students without any signs and symptoms of temporomandibular disorders were selected as the patients group and as the normal group, respectively. Head position to body-midline in frontal plane and upper quarter posture to body plumb line in sagittal plane were observed clinically and electromyographic(EMG) activity of anterior temporalis, masseter, sternocleidomastoideus, and trapezius on clenching were recorded with $BioEMG^{(R)}$ in four head postures, which were natural head posture(NHP), forward head posture(FHP), $20^{\circ}$ upward head posture(UHP), and $20^{\circ}$ downward head posture(DHP). Cephaloradiographs were also taken in the same head postures as in EMG taking, but that was taken only in NHP for the patient group. Cephalometric variables measured were SN angle, CVT angle, atlas inclination angle, occlusal plane angle, Me-C2 angle, pharyngeal width, occiput~axis distance, area of pharyngeal space, and cervical curvature. The data were analyzed by SAS statistical program. The results of this study were as follows : 1. Between the patient and the normal group, there were significant difference in distance from plumb line to acromion, eye-tragus angle, electromyographic activity of the four muscles, and cephalometric variables of linear measurement. 2. There was no consistent pattern of correlation between upper quarter posture, EMG activity and cephalometric variables in any case without relation to cervical curvature and head position in frontal plane. 3. Sternocleidomastoid muscle only showed variation of electromyographic activty with changes of head postures, but all the muscles did show correlation with head postures. 4. All the cephalometric variables measured in this study showed difference of mean value by head posture, and CVT angle, pharyngeal width, occiput-atlas distance, and area of pharyngeal space showed correlation between these variables with change from NHP to FHP, and from NHP to UHP.

  • PDF

A Study on the Effect of Arch Support for Improvement of Muscle Activity (운동효과 증진을 위한 Arch Support 효과에 관한 연구)

  • Lee, Chang-Min;Kim, Jin-Hoon;Oh, Yeon-Ju;Kim, Dae-Woong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.3
    • /
    • pp.71-79
    • /
    • 2008
  • Walking shoes for walking and jogging have been used to enjoy lots of leisure time. Functional shoes such as walking shoes have special functions to improve body motility by changing of shoe shapes. The walking shoes could improve the motility by structural transformation of outsole as increase degrees of heel and toe. The study on insoles has not been conducted enough on the contrary of the study of outsole. The purpose of this study is to perform ergonomics analysis whether the Arch Supported insoles have an improving effect of muscle activities or not. Experiments were performed with 6 subjects who are health and haven't experienced any diseases past. EMG(Electromyography) and Foot Pressures were measured repeatedly for 5 seconds at 0 hour, after 1 hour and after 2 hours of walking. Insoles used for experiment are normal insole, insole inserted Arch Support and pad. The electrodes for EMG measurement were set on waist (erector spinae), and thigh (vastus lateralis), calf (gastrocnemius). Evaluations of EMG were analyzed by shift of MF (Median Frequency) and MPF (Mean Power Frequency). Foot Pressure was analyzed by mean pressure of feet and change of walking time. As results, Arch Support insole had larger frequency shift value than that of normal insole. Frequency shift between Arch Support insoles and normal insole showed significant difference on 95% confidence interval. And insole 1 has the highest value of frequency shift. For results of foot pressure, Arch Support insoles show continuous decreasing tendency when comparing with normal insoles by changing of times. Also, insole 1 has the highest decreasing value of foot pressure. Therefore, this study presented that the Arch Support insole can promote muscle activities and improves comfort for a prolonged walking.

An Analysis of Kinematics and EMG for Bandal Chagi in Taekwondo (태권도 반달차기 시 운동학적 변인 및 근전도 분석)

  • Ha, Chul-Soo;Choi, Man-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.3
    • /
    • pp.11-21
    • /
    • 2008
  • The purpose of this study was to investigate the most optimum way of performing the bandal chagi during Taekwondo Kyorugi competition. By analyzing the EMG data and the kinematic data it was hoped that scientific data would be provided to instructors and players about the optimization of the Bandal Chagi. The results of the analysis are as follows: During competition while performing the Bandal Chagi the most important factors that affect the impact point are the range of motions of the upper body hyper extension and knee joints. Through the measurement of the muscles EMG activity of a well performed Bandal Chagi with the right leg it was observed that the left side erector spinae muscle was highly activated and so it was concluded that this muscle should be trained to improve the performance of the Bandal Chagi. Likewise it was observed that for the right side of the abdominal muscle's EMG there was a high activity level and thus showed that there was a large contribution of this muscle for the optimum performance of the Bandal Chagi.

Knee Rehabilitation System through EMG Signal analysis and BLDC Motor Control (근전도 신호 분석 및 BLDC모터 제어를 통한 무릎재활시스템)

  • Kwon, Hyeong-Gi;Ko, Hyeong-Gyu;Song, Yoon-Oh;Son, Eui-Seong;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.14 no.5
    • /
    • pp.1009-1018
    • /
    • 2019
  • This paper describes the design and implementation of a rehabilitation medical device based on a EMG measurement. Rehabilitation systems are controlled using BLDC motors and motor drives. The BLDC motor drive controls the operation and the speed controls the drive through the external servo motor. In addition, potentiometer coupled to the outside of the motor transmits information about the position of the load being rotated by the motor. The rehabilitation algorithm is controlled by limiting the maximum angle of 0 to 120 by utilizing the motor according to the user setting stage during the rehabilitation exercise. The walking algorithm compensates motor control for the low leg of the signal using the difference value of the signal obtained with the surface denser attached to both inner muscles. The motor and surface denser are utilized for the walk motion to control the maximum angle of 0 to 80.

A Study of a Module of Wrist Direction Recognition using EMG Signals (근전도를 이용한 손목방향인식 모듈에 관한 연구)

  • Lee, C.H.;Kang, S.I.;Bae, S.H.;Kwon, J.W.;LEE, D.H.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.7 no.1
    • /
    • pp.51-58
    • /
    • 2013
  • As it is changing into aging society, rehabilitation, welfare and sports industry markets are being expanded fast. Especially, the field of vital signals interface to control welfare instruments like wheelchair, rehabilitation ones like an artificial arm and leg and general electronic ones is a new technology field in the future. Also, this technology can help not only the handicapped, the old and the weak and the rehabilitation patients but also the general public in various application field. The commercial bio-signal measurement instruments and interface systems are complicated, expensive and large-scaled. So, there are a lot of limitations for using in real life with ease. this thesis proposes a wireless transmission interface system that uses EMG(electromyogram) signals and a control module to manipulate hardware systems with portable size. We have designed a hardware module that receives the EMG signals occurring at the time of wrist movement and eliminated noises with filter and amplified the signals effectively. DSP(Digital Signal Processor) chip of TMS320F2808 which was supplied from TI company was used for converting into digital signals from measured EMG signals and digital filtering. We also have used PCA(Principal Component Analysis) technique and classified into four motions which have right, left, up and down direction. This data was transmitted by wireless module in order to display at PC monitor. As a result, the developed system obtains recognition success ratio above 85% for four different motions. If the recognition ratio will be increased with more experiments. this implemented system using EMG wrist direction signals could be used to control various hardware systems.

  • PDF

A Non-invasive Measurement of Abdominal Pressure on Ambulatory Urodynamics Study Using Surface Electromyography (휴대용 요역동학 검사 시 근전도 신호를 이용한 복압측정 방법)

  • Kim, Keo-Sik;Song, Chul-Gyu;Seo, Jeong-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.132-140
    • /
    • 2008
  • Conventional rectal catheters which are used for the measurement of abdominal pressure can cause erroneous result affecting detrusor pressure, and the catheter itself is not comfortable to the patients. To reduce these problems, we invented a new method for measuring abdominal pressure in non invasive manner using surface electromyography (EMG) signals of the rectus abdominis muscle. Our results showed that the correlation coefficient and root mean square error (RMSE) between the measured abdominal pressures by the conventional rectal catheters and the estimated values by our proposed algorithm were $0.79{\pm}0.06$ and $0.10{\pm}0.07$, respectively. These findings suggest that the surface EMG of rectus abdominis muscle might be used indirectly for more convenient measurement of abdominal pressure on ambulatory urodynamic study.

Biological Signal Measurement, Archiving, and Communication System (SiMACS) (생체신호 측정 및 종합관리 시스템 (SiMACS))

  • Woo, Eung-Je;Park, Seung-Hun
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.49-52
    • /
    • 1994
  • We have developed a biological signal measurement, archiving, and communication system (SiMACS). The front end of the system is the intelligent data processing unit (IDPU) which includes ECG, EEG, EMG, blood pressure, respiration, temperature measurement modules, module control and data acquisition unit, real-time display and signal processing unit. IDPUS are connected to central data base unit through LAN(Ethernet). Workstations which receive signals from central DB and provide various signal analysis tools are also connected to the network. The developed PC-based SiMACS is described.

  • PDF