• Title/Summary/Keyword: EM 120

Search Result 49, Processing Time 0.023 seconds

The Exploration Methodology of Seafloor Massive Sulfide Deposit by Use of Marine Geophysical Investigation (해양 지구물리 탐사를 이용한 해저열수광상 부존지역 탐지 방법)

  • Kim, Hyun-Sub;Jung, Mee-Sook;Kim, Chang-Hwan;Kim, Jong-Uk;Lee, Kyeong-Yong
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.167-176
    • /
    • 2008
  • Lau basin of the south Pacific, as an active back arc basin, is promising area bearing seafloor massive hydrothermal deposit that is located in a subduction zone between the Pacific ocean plate and Indo-Australian continental plate. We performed multi-beam bathymetry survey in the Lau basin using EM120, to find out high hydrothermal activity Bone. Fonualei Rift and Spreading Center (FRSC) and Mangatolou Triple Junction (MTJ) area were selected for precise site survey through seafloor morphology investigation. The result of surface and deep-tow magnetometer survey showed that Central Anomaly Magnetization High (CAMH) recorded which is associated with active ridge in FRSC-2 and revealed very low magnetic anomalies that can be connected to past or present high hydrothermal activity in MTJ-1 seamount area. Moreover, the physical and chemical tracers of hydrothermal vent flume, i.e., transmission, hydrogen ion concentration (pH), adenosine triphosphate (ATP), methane (CH4) by use of CTD system, showed significant anomalies in those areas. From positive vent flume results, we could conclude that these areas were or are experiencing very active volcanic activities. The acquired chimney and hydrothermal altered bed rock samples gave us confidence of the existence of massive hydrothermal deposit. Even though not to use visual exploration equipment such as ROV, DTSSS, etc., traditional marine geophysical investigation approach might be a truly cost-effective tool for exploring seafloor hydrothermal massive deposit.

Study for Progress Rate of Standard Deviation of Irregularity Based on Track Properties for the Railway Track Maintenance Cycle Analysis (궤도 유지보수 주기 예측을 위한 구간 특성에 따른 궤도틀림 표준편차 진전정도 분석)

  • Jeong, Min Chul;Kim, Jung Hoon;Lee, Jee Ha;Kang, Yun Suk;Kong, Jung Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.31-40
    • /
    • 2012
  • The irregularity of railway track affects not only the comfort of ride such as noise or vibration but also the safety of train operation. For this reason, it is an interesting research area to design a reliable and sustainable railway track system and to analyze the train movement mechanism based on systematic approaches considering reasons of track irregularity possible in a specific local environment. Irregularity data inspected by EM-120, an railway inspection system in Korea includes unavoidable incomplete and erratic information, so it is encountered lots of problem to analyse those data without appropriate pre-data-refining processes. In this research, for the efficient management and maintenance of railway system, progress rate of standard deviation of irregularity is quantified. During the computation, some important components of railways such as rail joint, ballast, roadbed, and fastener have been considered. Probabilistic distributions of irregularity growth with respect to time are computed to predict the remaining service life of railway track and to be adapted for the safety assessment.

Design of Small-Area eFuse OTP Memory for Line Scan Sensors (Line Scan Sensor용 저면적 eFuse OTP 설계)

  • Hao, Wenchao;Heo, Chang-Won;Kim, Yong-Ho;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.8
    • /
    • pp.1914-1924
    • /
    • 2014
  • In this paper, a small-area cell array method of reducing number of SL drivers requiring large layout areas, where the SL drivers supplying programming currents are routed in the row direction in stead of the column direction for eFuse OTP memory IPs having less number of rows than that of columns such as a cell array of four rows by eight columns, and a core circuit are proposed. By adopting the proposed cell array and core circuit, the layout area of designed 32-bit eFuse OTP memory IP is reduced. Also, a V2V ($=2V{\pm}10%$) regulator necessary for RWL driver and BL pull-up load to prevent non-blown eFuse from being blown from the EM phenomenon by a big current is designed. The layout size of the designed 32-bit OTP memory IP having a cell array of four rows by eight columns is 13.4% smaller with $120.1{\mu}m{\times}127.51{\mu}m$ ($=0.01531mm^2$) than that of the conventional design with $187.065{\mu}m{\times}94.525{\mu}m$ ($=0.01768mm^2$).

Effect of Sound Velocity on Bathymetric Data Aquired by EM120(multi-beam echo sounder) (EM120(multi-beam echo sounder)을 이용한 지형조사 시 적용되는 해수 중 음속 측정의 중요성; 수중음속 측정장비의 특성 비교)

  • Ham, Dong-Jin;Kim, Hyun-Sub;Lee, Gun-Chang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.295-301
    • /
    • 2008
  • Bathymetric data collected using a multi-beam echo sounder during marine scientific survey is essential for geologic and oceanographic research works. Accurate measurment of sound velocity profile(SVP) in water-column is important for bathymetric data processing. SVP can vary at different locations during the survey undertaken for wide areas. In addition, an observational error can occur when different equipments(Sound Velocity Profiler, Conductivity Temperature Depth, eXpendable BathyThermograph) are used for measuring SVP at the same water column. In this study, we used an MB-system software to show changes in bathymetry caused by variation of SVP. The analyses showed that the sound velocity(SV) changes due to the depth and thickness of thermocline had more significant effects on the resulting bathymetric data than those of surface mixed layer. The observational errors between SVP measuring instruments did not cause much differneces in the processed bathymetric data. Bathymetric survey line is better to be established to the direction that the change of temperature can be minimize to reduce the variation of SVP during the data acquisition along the survey line.

Cloning of Autoregulator Receptor Gene form Saccharopolyspora erythraea IFO 13426 (Saccharopolyspora erythraea IFO 13426으로부터 Autoregulator Receptor Protein Gene의 Cloning)

  • 김현수;이경화;조재만
    • Microbiology and Biotechnology Letters
    • /
    • v.31 no.2
    • /
    • pp.117-123
    • /
    • 2003
  • For screening of autoregulator receptor gene from Saccharopolyspora erythraea, PCR was performed with primers of receptor gene designed on the basis of amino acid sequences of autoregulator receptor proteins with known function. PCR products were subcloned into the BamHI site of pUC19 and transformed into the E. coli DH5$\alpha$. The isolated plasmid from transformant contained the fragment of 120 bp, which was detected on 2% gel after BamHI treatment. The insert, 120 bp PCR product, was confirmed as the expected internal segment of gene encoding autoregulator receptor protein by sequencing. Southern and colony hybridization using Saccha. erythraea chromosomal DNA were performed with the insert as probe. The plasmid (pEsg) having 3.2 kbp SacI DNA fragment from Saccha. erythraea is obtained. The 3.2 kbp SacI DNA fragment was sequenced by the dye terminator sequencing. The nucleotide sequence data was analyzed with GENETYX-WIN (ver 3.2) computer program and DNA database. frame analyses of the nucleotide sequence revealed a gene encoding autoregulator receptor protein which is a region including KpnI and SalI sites on 3.2 kbp SacI DNA fragment. The autoregulator receptor protein consisting of 205 amino acid was named EsgR by author. In comparison with known autoregulator receptor proteins, homology of EsgR showed above 30%.

Effect of the Heat Input on the Tensile Properties in Arc Brazing of Ferritic Stainless Steel using Cu-Si Insert Alloy (Cu-Si계 삽입금속을 사용한 페라이트계 스테인리스강의 아크 브레이징에서 인장성질에 미치는 입열량의 영향)

  • Kim, Myung-Bok;Kim, Sang-Ju;Lee, Bong-Keun;Yuan, Xin Jian;Yoon, Byoung-Hyun;Woo, In-Su;Kang, Chung-Yun
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.289-296
    • /
    • 2010
  • The effects of heat input and different microstructureswere investigated on the tensile-shear properties of an arc-brazed joint of theferritic stainless steel 429EM using a Cu-Si insert alloy. The brazing speed was fixed at 800 mm/min whilethe brazing current varied from 80 to 120A. For abrazing current lower than 100A, fracturing occurred at the joint root in the direction perpendicular to the tensile load. As the brazing current increased to 120A, fracturing occurred at the base metal or the joint root. The joint and the base metal had very similar yield and tensile load values. However, the amount of elongation was decreased considerably compared to when the base metal was used. The fracturing began at the triple point of the root part and was classified into three types. The difference in the tensile-shear properties was closely related to the three fracture types.

Analysis method for the Measured Track Geometry Data using Wavelet Transform (웨이브렛 변환을 이용한 궤도틀림 분석)

  • Lee, In-Kyu;Kim, Sung-Il;Yeo, In-Ho
    • Journal of the Korean Society for Railway
    • /
    • v.9 no.2 s.33
    • /
    • pp.187-192
    • /
    • 2006
  • The regularity of railway track alignment is a crucial component fur maintaining travel safety and the smoothness of passenger ride. The conventional spectral analysis has been considered to estimate the severity of the track irregularity from measured data. The time domain data used to be changed into the frequency domain by Fourier transform. Because the measuring points can be regarded as the time points, the spatial-frequency can be introduced instead of the time-frequency. Although FFT(Fast Fourier Transform) and/or PSD(Power Spectral Density) function could provide fairly localized information within frequency domain, but chronical configurations of data could be missed. In this study, we attempt to apply the Morlet wavelet transform for the purpose of a frequency-time-domain analysis rather than a frequency-domain analysis. The applicability of wavelet transform is examined for the estimation of the track irregularity with real measured track data on the section of Kyoung-bu line by EM-120 measuring vehicle. It is shown that the wavelet transform can be an effective tool to manage the track irregularity.

A Sensitive Fluorescent Detection Method for Prostaglandins by High Performance Liquid Chromatography (고속액체크로마토그라피에 의한 프로스타글란딘류의 고감도 형광 분석법)

  • Lee, Yong-Moon;Moon, Dong-Cheul
    • YAKHAK HOEJI
    • /
    • v.36 no.5
    • /
    • pp.506-511
    • /
    • 1992
  • The Prostaglandins were derivatized rapidly with monodansyl cadaverine as a fluorophore in mild conditions. The carboxylic moiety of prostaglandins was activated with diethyl phosphorocyanidate and successively coupled with fluorophore in dimethylformamide at room temperature. The labeling yield was reached about 95% at 15 min using arachidic acid $(C_{20:0})$ as a test sample. This derivative showed constant fluorescent intensity at $4^{\circ}C$ for 180 days. The derivatives of prostaglandins were shown high solvent selectivity with tetrahydrofuran in reversed-phase column. therefore, these derivatives could be successfully separated on YMC pack A-212(S-5 120A C8) column in tetrahydrofuran-based eluents. The detection limits of these derivatives was ca. 500 fmol and determination limits was ca. 5 pmol as injected amount in fluorescent detection $({\lambda}ex.\;340\;nm,\;{\lambda}em.\;520\;nm)$. In this method, the ranges of recovery and coefficient of variation were $93.6{\sim}102.7%$ and $4.3{\sim}5.8%$, respectively.

  • PDF

Design and Implementation of Compact Ultra Wideband Patch Antenna Using L-Feed and Slot-Feed (L 급전 및 Slot 급전을 동시에 적용하는 광대역 소형 패치 안테나의 설계 및 구현)

  • Choi, Jong-In;Lee, Bomson
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.5
    • /
    • pp.484-491
    • /
    • 2013
  • In this paper, the method of designing a wideband antenna has been introduced through the design technique that simultaneously employs L- and slot-type feeds. Using the two kinds of feeds and additional fence structure, a compact wideband patch antenna has been realized. The size of the patch has been reduced by about 30 % based on the low frequency(824 MHz) and the full fractional bandwidth is wider than 100 %. The L-feed element is for the EM coupling feeding at the low frequency, while it functions as a feeding line for the power coupling through the slot at the high frequency. The proposed antenna has been designed not only for wideband operations but also for a proper array element with a reduced size. Thus, the foundation for developing the ultra wideband patch array antennas has been prepared. The fabricated antenna has been found to have good characteristics on V.S.W.R and the radiation patterns over the full bands. The experimental and computed results are shown to be in good agreement.

Determination and survey of fluoroquinolones in meats and eggs (II) (식육 및 계란에서 플루오로퀴놀론계 항균물질 정량분석 및 잔류조사 (II))

  • Choi, Yoon-Hwa;Kim, Yeon-Ju;Lee, Kyung-Hye;Kang, Young-Il;Lee, Jung-Hark
    • Korean Journal of Veterinary Service
    • /
    • v.32 no.3
    • /
    • pp.281-286
    • /
    • 2009
  • Fluoroquinolones in muscle and egg were separated by liquid extraction and determined. The analysis was carried out using following conditions; C18 column ($150{\times}4.6mm$, $5{\mu}m$), mobile phase composed of D.W. (containing 0.4% triethylamine and phosphoric acid) : methanol : acetonitrile (780:100:120, v/v/v), quarternary pump at a flow rate of 0.9ml/min and $20{\mu}l$ of injection volume, fluorescence detector with EX 278nm/Em 456nm. The calibration range of seven fluoroquinolones showed linearity ($r^2{\geq}0.999$) at concentration range of $0.025{\sim}0.8{\mu}g/ml$. The recoveries in fortified muscle and egg represented more than 81.3%. The detection limits for ofloxacin, norfloxacin, ciprofloxacin, enrofloxacin, danofloxacin, saraloxacin and orbifloxacin were 3.1, 2.5, 3.6, 1.7, 0.9, 2.5 and $2.1{\mu}g/kg$, respectively. We also monitored fluoroquinolones residue in the sample (chicken muscle 182, cattle muscle 140, pig muscle 139, egg 212) using EEC-plate (E. coli ATCC 11303) screening and HPLC confirmation methods. The screening test results, fluoroquinolones, antibacterial substances were all negative.