• 제목/요약/키워드: ELF(extremely low frequency)

검색결과 73건 처리시간 0.026초

전위계차센서 기반 스마트TV 제어를 위한 극저주파 전자기간섭 제거 연구 (Study on Elimination of EMI in ELF-Band for EPS-Based Smart TV Control)

  • 장진수;김영철
    • 한국멀티미디어학회논문지
    • /
    • 제18권3호
    • /
    • pp.401-407
    • /
    • 2015
  • In this paper, we propose the method to eliminate EMI (Electro-Magnetic Interference) in ELF (Extremely Low Frequency) band below 2 KHz for extending the gesture-recognition distance of smart TVs to more than 3m using electric potential sensor. First, we measure the electric field generated from the back panel of a TV and propose the effective arrangement of two sets of differential sensors as well as the shielding method using metal fiber. Also, we eliminate the PLN (Power Line Noise) and other noise generated from the TV and sensors as well as surrounding environments using filters. Using the proposed EMI eliminating methods, we evaluate displacement ratio on measured signals according to distance between sensors and a moving hand. Experiment results show that our proposed method can extend the hand-gesture sensing distance using EPS (Electric Potential Sensor) up to more than 3m, which is enough to satisfy applicability of EPS based remote control to Smart TVs.

옥천대내(沃川帶內) 신당(新堂)-도전리(道田里) 지역(地域)에 대한 ELF-MT 탐사(探査) 연구(硏究) (ELF-MT Survey Between Sindangri and Dojonri Area in the Okchon Zone)

  • 민경덕;전정수;정승환
    • 자원환경지질
    • /
    • 제21권3호
    • /
    • pp.277-285
    • /
    • 1988
  • The ELF-MT survey has been conducted at 9 points along the national road between the Sindangri and Dojonri area to study on the boundary between the Okchon and Choson systems, and subsurface geological structure of these two systems. Natural electromagnetic fields of 7.8, 14, and 20 Hz in the Schumann resonant frequency band were used for ELF-MT measurement. Apparent resistivity values were calculated from the measured magnetic and electric fields at each frequency, and resistivity sections were obtained by means of a trial and error method for one-dimensional analysis and finite element method for two-dimensioal analysis. The results of this study show that the resistivities of the Okchon and Choson systems are 700-3500 ohm-m and 40-5000 ohm-m, respectively. The boundary between these two systems is a fault with the width of 1 km fault zone and resistivity value of 200 ohm-m, and is located around Koburangjae. Another fault is appeared in Sindangri, and its resistivity value is 130 ohm-m. Intrusion of biotite granite is distributed in Jungchijae, and its resistivity value is 750 ohm-m. The area between Susanri and Koburangjae shows the highest resistivity value of 3500 ohm-m because metabasite and amphibolite are distributed in that area. Extremely low resistivity value of 40 ohm-m around Yongamsan is due to the Yongam formation, which is composed of graphitic black slate and overlying Choson Great Limestone group.

  • PDF

개인 노출량 조사를 통한 한국인의 극저주파 자기장 노출 수준 (Estimation of ELF-MF Exposure Levels in the Korean Population through 24-Hour Personal Exposure)

  • 정준식;김근영;홍승철;조용성;김윤신
    • 한국환경보건학회지
    • /
    • 제38권1호
    • /
    • pp.18-30
    • /
    • 2012
  • Objectives: The purpose of this study was to estimate the exposure level to extremely low frequency-magnetic fields (ELF-MF) among a selected Korean population using 24-hour personal exposure measurement. Methods: Participants were randomly selected for the measurement of MF exposure under the assumption that the subjects are representative of the overall Korean population. Levels of personal exposure to MF were measured according to the subject's daily activities. Results: The 24-hour time-weighted average (TWA) of 250 participants was $1.56{\pm}4.56$ mG (GM, GSD: 0.79, 2.46 mG). Personal exposure levels for females were higher than for males. The highest personal exposure level was shown in the age group between 20-60 years old. Personal exposure levels according to job category were higher for the non-occupational group than for the occupational group. Conclusions: Our results showed MF exposure exceeding 2 mG per day among 11.3% of the Korean population, indicating a somewhat higher percentage compared to the EMF RAPID Program's results for the U.S population.

근로자들의 극저주파 전자파 노출 수준에 따른 인체 영향 평가 (Health Status of Electric Utility Workers Exposed to Extremely Low Frequency Electromagnetic Field (ELF-EMF))

  • 박경호;안용호;김태전
    • 대한임상검사과학회지
    • /
    • 제37권3호
    • /
    • pp.220-227
    • /
    • 2005
  • Recently, the use of an electrical apparatus has brought up concerns of health risks from exposure to electromagnetic fields. EMF is composed of electric fields and magnetic fields. Heavy exposure to EMF can occur only in the vicinity of high-voltage overhead transmission lines, close to transformers and underground cables, and also close to large electrical machinery. In this thesis I have investigated the hypothesis of the correlation between occupational exposure to ELF-EMF and the risks of leukemia, anemia, cancer. Therefore, the aim of this study is to investigate whether or not ELF-EMF emitted from electric power stations and transformer substations affect some hematological parameters and tumor markers of electric utility workers. The hematological test results and tumor markers under investigation were similar in the two groups but some of parameters such as RBC, AFP, LDH showed significant difference between the two groups from two sample t-test (p<0.05). The exposure group showed increased LDH level compared to the control group by two sample t-tests. In addition, the abnormal LDH level in the exposure group was observed to be clinically significant by ${\chi}^2$-test. However, the levels of RBC, AFP observed were not clinically significant by ${\chi}^2$-test (p>0.05). These results suggested that ELF-EMF does not affect most blood test parameters except LDH of electric utility workers.

  • PDF

발전기의 전자기장 분포 특성에 따른 작업자 노출공간 분석 (Analysis of Worker Exposure Space according to Distribution of Electromagnetic Field of Generator)

  • 성민영;김두현;김승태
    • 한국안전학회지
    • /
    • 제36권4호
    • /
    • pp.20-28
    • /
    • 2021
  • With an increase in the commercialization of electricity, and the development of advanced and large electric devices and various wireless radio wave services, concerns over the effects of electromagnetic fields on human health have increased. Accordingly, the World Health Organization encouraged the development of international standards by establishing the 'International Electromagnetic Fields Project' in 1996 based on studies on the harmful effects of electromagnetic fields on the human body. Moreover, the National Institute of Environmental Health Sciences (NIEHS) classified electromagnetic fields as possible carcinogens under Group 2B category, even though they have been found to have a weak correlation with those effects on human health. Mid-to-large-sized electric facilities used at industrial sites mostly adopt a commercial frequency of 60 Hz, and workers handling these facilities are exposed to such extremely low frequency (ELF) fields for a long time. A previous study suggested that exposure to ELF electromagnetic fields with frequency ranges from 0 to 300 Hz, even for a short time, at densities higher than 100 μT may have harmful effects on human body as it affects the activation of nerve cells in the central nervous system by inducing an electric field and current and stimulating muscles and the nervous system in the body. Such studies, however, focused on home appliances used by ordinary people, and research on facilities utilizing high-capacity current and operated by workers at industrial sites is lacking. Therefore, in this study, a 3000 kilowatt generator, which is a high-capacity electric facility employed at industrial sites, was investigated, and the size of the magnetic fields generated during its no-load and high-load operations per distance to produce a map was measured to reveal spots deemed hazardous according to domestic and international exposure standards. The findings of this study is expected to alleviate workers' anxiety about the harmful effects of magnetic fields on their body and to minimize the level of exposure during operations.

변전소 주변 자계 실태조사 및 자계 특성이 이해증진 방안 (Survey on Magnetic Field around Substations and Proposals to Broaden Understanding of the Magnetic Field Characteristics)

  • 이성수;신현식
    • 한국전자파학회논문지
    • /
    • 제20권6호
    • /
    • pp.526-534
    • /
    • 2009
  • 본 논문은 전력공급설비 중 변전설비에서 발생하는 극저주파에 의한 자계의 실태를 조사하고 자계의 특성에 관한 이해증진 방안을 제시하는데 그 목적이 있다. 본고에서는 수도권 25개 변전설비를 중심으로 변전소 주변과 감사실 내부의 자계 수준을 IEC에서 제시하는 CISPR의 측정 방법(IEC/TC106 PT 62110)에 의거하여 변전설비에서 발생하는 자계를 측정하였다. 아울러 전력설비와 관련된 자계의 속성에 대한 정확한 이해를 위해 전자계 인증표시제와 같은 객관적이고 신뢰성 높은 정책적 접근방안을 제시한다.

Benzodiazepine System is Involved in Hyperalgesia in Rats Induced by the Exposure to Extremely Low Frequency Magnetic Fields

  • Jeong Ji Hoon;Choi Kyung Bum;Moon Nam Ju;Park Eon Sub;Sohn Uy Dong
    • Archives of Pharmacal Research
    • /
    • 제28권2호
    • /
    • pp.238-242
    • /
    • 2005
  • Many reports demonstrate that extremely low frequency magnetic fields (ELF MFs, 60 Hz) may be involved in hyperalgesia. In a previous investigation, we suggested that MFs may produce hyperalgesia and such a response may be regulated by the benzodiazepine system. In order to further confirm this effect of MFs, we used diazepam and/or flumazenil with MFs exposure. When testing the pain threshold of rats using hot plate tests, MFs or diazepam ($0.5\;{\mu}g$, i.c.v.; a benzodiazepine receptor agonist) induced hyperalgesic effects with the reduction of latency. These effects were blocked by a pretreatment of flumazenil (1.5 mg/kg, i.p.; a benzodiazepine receptor antagonist). When the rats were exposed simultaneously to MFs and diazepam, the latency tended to decrease without statistical significance. The induction of hyperalgesia by co-exposure to MFs and diazepam was also blocked by flumazenil. However, the pretreatment of GABA receptor antagonists such as bicuculline ($0.1\;{\mu}g$, i.c.v.; a $GABA_A$ antagonist) or phaclofen ($10\;{\mu}g$, i.c.v.; a $GABA_B$ antagonist) did not antagonize the hyperalgesic effect of MFs. These results suggest that the benzodiazepine system may be involved in MFs-induced hyperalgesia.

반도체 제조 근로자의 극저주파 자기장 노출 평가 (Occupational Exposure of Semiconductor Workers to ELF Magnetic Fields)

  • 정은교;김갑배;정광재;이인섭;유기호;박정선
    • 한국산업보건학회지
    • /
    • 제22권1호
    • /
    • pp.42-51
    • /
    • 2012
  • Objectives: To compare the exposure level of extremely low frequency (ELF) magnetic fields among semiconductor workers, shipyard welders and office workers. Methods: To measure the ELF magnetic field concentration, EMDEX LITE (Enertech, USA) were used and monitored for eight hours continuously. Five companies handling the electric and magnetic field (EMF) source were investigated, which the exposure groups were classified into three groups: semiconductor workers, welders, and office workers. Welder group was chosen as a high exposed group and office group as a low exposed group. Results: The arithmetic mean (${\pm}SD$) and geometric mean (GSD) of personal exposure level of semiconductor workers were 0.73 (${\pm}1.33$) ${\mu}T$, 0.43 (2.88) ${\mu}T$, respectively. The ceiling value ranged between 0.18 and 123.2 ${\mu}T$. Welders were exposed high with the arithmetic mean value of 3.46 (${\pm}\;13.46$) ${\mu}T$ and geometric mean value of 0.45 (4.70) ${\mu}T$, respectively, and ceiling value range of 75.5~129.6 ${\mu}T$. The exposure levels of office workers were low compared to other exposed groups; the arithmetic mean 0.05 (${\pm}0.13$) ${\mu}T$, geometric mean 0.03 (2.38) ${\mu}T$ and ceiling value range 0.37~3.35 ${\mu}T$. This study revealed statistically significant differences of the mean ELF magnetic field exposure doses among three groups (p < 0.01). Conclusions: The average ELF magnetic field exposure doses of semiconductor workers were much higher than those of office workers in control group, but were lower than those of welders in high exposure group.

Extremely Low Frequency Magnetic Field is an Environmental Stress Factor by Exerting Oxidative Stress

  • Park, Yong-Jin;Park, Won-Joo;Yim, Sung-Hyuk;Yang, Seong-Jun;Sun, Yuan Lu;Jeong, Ji-Hoon;Park, Eon-Sub
    • Biomolecules & Therapeutics
    • /
    • 제15권1호
    • /
    • pp.58-64
    • /
    • 2007
  • The previous study reported the biological effect of magnetic field exerted by acting on endocrine and anti-oxidant system. The present study aims to study whether ELF-MF (extremely low frequency magnetic field) affects the physiological endocrine systems such as thyroid and whether ELF-MF affects the defense system against oxidative stress when it alters the function of thyroid. Finally, we correlate the effects of MF on oxidative stress, and adrenal and thyroid with an environmental stress factor. We exposed sham or MF to rats for 5 or 25 days. After the exposure, we determined pain sensitivity, level of TSH, $T_3$ and free $T_4$ in plasma. We also assayed in whole brain, lipid peroxidation, the activity of enzymatic anti-oxidant defense including superoxide dismutase(SOD) and glutathione peroxidase (GPx), and non enzymatic defense such as reduced or oxidized glutathione contents. MF induced the hypersensitivity to thermal stimuli with the reduction of latency. $T_3$ and $T_4$ levels were also increased by the exposure of MF. In addition, we observed the rise of MDA level in rat brain by MF although the MF did not change superoxide dismutase and glutathione peroxidase activity. The effect of MF on both reduced and oxidized glutathione results in decrease in reduced or oxidized glutathione in whole brain. In every experiment, there was no significant difference in MF influence between short term (5 days) and long term (25 days) exposure. Taken together, MF exposure affects the thyroid hormonal control in brain. The elevated thyroid hormone acts on brain, leading to hyper-utilization of oxygen. This phenomenon may be correlated with oxidative stress resulting from MF exposure. In conclusion, we suggest that MF exposure may be an environmental stress by exerting oxidative stress.

상용전원 주파수(60Hz)를 사용한 중전력 무선전력전송 연구 (Research on Medium-power Wireless Power Transmission using Commercial Power Frequency (60Hz))

  • 이기범
    • 한국전자통신학회논문지
    • /
    • 제19권3호
    • /
    • pp.497-506
    • /
    • 2024
  • 본 논문에서는 상용전원 주파수(60 Hz)를 사용하여 중전력 무선전력전송을 구현한 것이다. 일반적인 자기유도 무선전력전송 장치는 수십 kHz 이상 사용하기 때문에 상용전원 주파수(60 Hz)를 그대로 사용할 수 없고, 교류/직류 변환기를 사용하여 60 Hz 전원주파수를 DC로 만들고, 고주파 파워앰프를 사용하여 DC를 수십 KHz로 만들어서 사용한다. 자기유도 무선전력전송에서 교류/직류 변환기와 고주파 파워앰프를 제거하고, 송전 공진탱크, 송전코일, 수전 공진탱크, 수전코일 만으로 구성한 상용전원 주파수를 사용하는 극저주파 무선전력전송 시스템을 구현하고, 무선전력전송 실험으로 검증하였다.