• Title/Summary/Keyword: EIS

Search Result 549, Processing Time 0.033 seconds

Electrochemical Performance of Pitch coated Nano Silicon Sheets / Graphite Composite as Anode Material (피치로 코팅된 Nano Silicon Sheets/Graphite 음극복합소재의 전기화학적 특성)

  • Lee, Tae Heon;Lee, Jong Dae
    • Korean Chemical Engineering Research
    • /
    • v.59 no.4
    • /
    • pp.487-492
    • /
    • 2021
  • In this study, the electrochemical properties of pitch coated silicon sheets/graphite anode materials were investigated. Using NaCl as a template, silicon sheets were prepared through the stöber method and the magnesiothermic reduction methode. In order to synthesize the anode composite, the silicon sheets and graphite were combined with SDBS. The pitch coated silicon sheets/graphite was synthesized using THF as a solvent for the anode material composite. The physical properties of the prepared anode composites were analysed by XRD, SEM, EDS and TGA. The electrochemical performances of the prepared anode composites were performed by the current charge/discharge, rate performance, cyclic voltammetry and EIS tests in the electrolyte LiPF6 dissolved solvents (EC:DMC:EMC=1:1:1 vol%). As the silicon composition of silicon sheets/graphite composite material increased, the discharge capacity also increased, but the cycle stability tended to decrease. The anode material of pitch coated silicon sheets/graphite composite (silicon sheets:graphite=3:7 weight ratio) showed the initial discharge capacity of 1228.8 mAh/g and the capacity retention ratio of 77% after 50 cycles. From these results, it was found that the cycle stability of pitch coated silicon sheets/graphite was improved.

Survey on the Perception of Stakeholders on the EIA System in Korea (한국 환경영향평가 제도에 대한 이해관계자의 인식 조사)

  • Kim, Minkyung;Lee, Sangdon
    • Journal of Environmental Impact Assessment
    • /
    • v.30 no.1
    • /
    • pp.49-60
    • /
    • 2021
  • Environmental impact assessment (EIA) practitioners play a very pivotal role in establishing EIA policies, and when implementing EIA environmental conflicts can be prevented and resolved by sharing information with stakeholders and coordinating opinions. For this reason, grasping the perceptions of stakeholders including practitioners about the overall system, such as EIA policies and implementation, can be helpful in setting improvement directions and policy directions for EIA. However, there is an insufficient information on the perception and understanding of stakeholders about the EIA system and operation currently in effect in Korea. Therefore, this study diagnoses operational and procedural problems for the EIA system, which is a decision-making tool and a precautionary technique that can minimize adverse effects through the environmental information analysis method, and improvement points and systems of the EIA system in the future. We tried to find a complement of an online survey of 37 questions,responses from 95 responses from stakeholders of EIA were summarized. Stakeholders were aware of the problems of the operation of the current system and the preparation of the evaluation form, and this was reflected. Period and cost of preparation of EIS (49%), the introduction of a new method (26%) and the items of collecting opinions and conflict management (41%), which showed high negative response rates (dissatisfied and very dissatisfied), are considered to be areas that we need to supplement further in the future. As society develops rapidly, the system needs to be supplemented accordingly, and policy improvement efforts are needed for items with high negative responses as a result of the survey.

Enzyme-Free Glucose Sensing with Polyaniline-Decorated Flexible CNT Fiber Electrode (Polyaniline을 이용한 CNT fiber 유연 전극 기반의 비효소적 글루코스 검출)

  • Song, Min-Jung
    • Korean Chemical Engineering Research
    • /
    • v.60 no.1
    • /
    • pp.1-6
    • /
    • 2022
  • As the demand for wearable devices increases, many studies have been studied on the development of flexible electrode materials recently. In particular, the development of high-performance flexible electrode materials is very important for wearable sensors for healthcare because it is necessary to continuously monitor and accurately detect body information such as body temperature, heart rate, blood glucose, and oxygen concentration in real time. In this study, we fabricated the nonenzymatic glucose sensor based on polyaniline/carbon nanotube fiber (PANI/CNT fiber) electrode. PANI layer was synthesized on the flexible CNT fiber electrode through electrochemical polymerization process in order to improve the performance of a flexible CNT fiber based electrode material. Surface morphology of the PANI/CNT fiber electrode was observed by scanning electron microscopy. And its electrochemical characteristics were investigated by chronoamperometry, cyclic voltammetry, electrochemical impedance spectroscopy. Compared to bare CNT fiber electrode, this PANI/CNT fiber electrode exhibited small electron transfer resistance, low peak separation potential and large surface area, resulting in enhanced sensing properties for glucose such as wide linear range (0.024~0.39 and 1.56~50 mM), high sensitivity (52.91 and 2.24 ㎂/mM·cm2), low detection limit (2 μM) and good selectivity. Therefore, it is expected that it will be possible to develop high performance CNT fiber based flexible electrode materials using various nanomaterials.

An Experimental Study on Relationship Between Half-Cell Potential and Corrosion Current Density of Chloride-Induced Corroded Steel in Concrete (염해에 따라 콘크리트 속에서 부식된 철근의 반전지전위와 부식전류밀도의 상관관계에 관한 실험적 연구)

  • Jo, Sang-Hyeon;Kim, Dong-Won;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.1-13
    • /
    • 2022
  • This study aims to investigate the feasibility of the half-cell potential (HCP) measurements on the concrete surface for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete. A series of experimental study is performed to measure HCP (or corrosion potential, Ecorr) and corrosion current density (icorr) of reinforcing steel in concrete cube specimens, with a side length of 200 mm. Various corrosion levels in a range of 0% to 20% of the test specimens are accelerated by impressing current to the reinforcing steel in concrete immersed in 3.0 % NaCl solution. HCP is measured in accordance with ASTM C876-15, and corrosion current density is determined by using the Stern-Geary equation and measured polarization resistance measured by electrochemical impedance spectroscopy (EIS). As a result, a numerical formula that relates HCP and icorr in the test specimen is established by a regression analysis of the measured data in this study. It is observed that HCP is linearly correlated with log(icorr) with a R2 greater than 0.87, which is less affected by the experimental variables such as concrete mixture proportion, diameter of reinforcing steel and the amount of applied current in this study. These results exhibit that HCP measurements could be effective for evaluation of corrosion rate (or corrosion levels) of reinforcing steel in concrete in the case of exposed to a certain consistent environment.

Changes of The Epidemiologic Competences after Introductory Course of The Korea - Field Epidemiologist Training Program(K-FETP) in Epidemiologic Intelligence Servise(EIS) Officers (한국 역학조사관 기본교육(K-FETP) 전후 역량 평가)

  • Kim, Eun-Young;Lee, Moo-Sik;Lee, Tae-Jun;Lee, Kwan;Nam, Hae-Sung;Lee, Ju-Hyoung;Kim, Hong-Bin;Chun, Byung-Chul;Lee, Sang-Won;Lee, Dong-Han;Kim, Hee-Jung;Kwon, Sung-Whe;Yoon, Na-Bi;Shin, Moon-Chul;Lim, Mee-Jee
    • Journal of agricultural medicine and community health
    • /
    • v.47 no.2
    • /
    • pp.78-89
    • /
    • 2022
  • 목적: 이 연구는 2019학년도 역학조사관 입문교육 과정에 참여한 29명의 수습과정생에게 참여형 자기주도 학습 역학조사관 연수 프로그램(FETP)의 효과와 만족도 등 역량 변화를 분석해 그 결과를 향후 과정 개발의 참고 자료로 활용하고자 하였다. 방법: 교육 프로그램의 만족도와 교육 후 모듈에 대한 역량 변화를 평가하는 연구가 수행되었다. 만족도와 역량의 차이 비교는 크루스칼 왈리스 검정(Kruskal-Wallis test)를 실시하였고, 역량의 차이는 윌콕슨 부호순위검정(Wilcoxon signed rank test)에 의해 이루어 졌다. 결과: 2019년 FETP에 참여한 역학조사관 중 여성은 48.3% 였으며, 40세 미만은 9.4% 였다. 역학조사관 입문교육과정 모듈(역학조사, 보건통계 및 정보통계, 감염병 국가 체계, 감염병 질환 감시 체계, 진단 및 실험실 검사, 생물 안전 및 관리, 주요 감염성질환 관리와 조사, 커뮤니케이션, 협동과 리더십, 일반과정)별 만족도는 실무적 도움, 전문성, 기능, 태도 등에서 4점(5점 만점)을 초과하였고, 전체 4.2±0.21(5점 만점)점으로 높은 수준이였다, 모듈의 교육훈련 전후 평균 점수는 2.25±0.91, 3.68±0.63점 등으로 유의한 향상이 있었으며, 모든 모듈 및 하위 주제들도 유의한 향상이 있었다(p<0.001). 그 중에서 현장역학조사 경험이 가장 높은 변화가 있었고, 표본 수집과 실무가 가장 낮은 역량 변화가 있었다. 결론: 2019년 진행된 입문교육 과정은 수료 후 학생들의 역량은 개선되었고, 만족도는 높은 편이었다. 참여형 자기주도학습의 촉진은 역량을 향상시킬 뿐만 아니라 보건 종사자들의 자신감을 높일 수 있었다.

Electrochemical Characteristics of Dopamine coated Silicon/Silicon Carbide Anode Composite for Li-Ion Battery (리튬이온배터리용 도파민이 코팅된 실리콘/실리콘 카바이드 음극복합소재의 전기화학적 특성)

  • Eun Bi Kim;Jong Dae Lee
    • Korean Chemical Engineering Research
    • /
    • v.61 no.1
    • /
    • pp.32-38
    • /
    • 2023
  • In this study, the electrochemical properties of dopamine coated silicon/silicon carbide/carbon(Si/SiC/C) composite materials were investigated to improve cycle stability and rate performance of silicon-based anode active material for lithium-ion batteries. After synthesizing CTAB/SiO2 using the Stöber method, the Si/SiC composites were prepared through the magnesium thermal reduction method with NaCl as heat absorbent. Then, carbon coated Si/SiC anode materials were synthesized through polymerization of dopamine. The physical properties of the prepared Si/SiC/C anode materials were analyzed by SEM, TEM, XRD and BET. Also the electrochemical performance were investigated by cycle stability, rate performance, cyclic voltammetry and EIS test of lithium-ion batteries in 1 M LiPF6 (EC: DEC = 1:1 vol%) electrolyte. The prepared 1-Si/SiC showed a discharge capacity of 633 mAh/g and 1-Si/SiC/C had a discharge capacity of 877 mAh/g at 0.1 C after 100 cycles. Therefore, it was confirmed that cycle stability was improved through dopamine coating. In addition, the anode materials were obtain a high capacity of 576 mAh/g at 5 C and a capacity recovery of 99.9% at 0.1 C/0.1 C.

Changes of General Components and Aromatic Constituents in Codonopsis lanceolata Grown at The Native and Cultivated Area (재배장소에 따른 더덕의 일반성분과 향기성분의 조성변화)

  • 이승필
    • Korean Journal of Plant Resources
    • /
    • v.9 no.3
    • /
    • pp.230-238
    • /
    • 1996
  • The experiment was carried out to find aromatic constituent composition of Codonopsis lanceolata species grown in the native(Mt. lrwol, Youngyang, Kyungpuk Province) and the cultivated(Andong, Kyungpuk Province) areas from 1994 to 1995. The results were as follows : Air temperature and soil temperature at the native area were lower to $2{\sim}3^{\circ}C$, and to $2^{\circ}C$ than the cultivated area. Organic matter contents of plant grown at the native area higher than that of plants at the cultivated area by 4.8%. Crude protein content was higher in plant grown at native area than the plant grown in wild area but in case of crude saponin, plants grown at wild area was higher than that of native area. For inorganic element contents. K content is much higher than in the domesticated area as compared with wild area above ten over. And other elements such as Cu, Mn, Na and Mg were not remarkably different in contents. In the free amino acid compositions, argine was highest compared with other free amino acids, and Arginine content was higher in dometicated area. Recovery yield of essential oil of wild species grown at the cultivated showed 0.005%, but domesticated species was 0.004%. But both species at the native area were the same by 0.004%. Although composition of aromatic constituents in the two areas and species varied, total aromatic constituent was 21 kinds. Most aromatic constituents were aliphatic alcohols such as 1-hexanol, eis-3-hexanol, and trans-2-hexanol occupied by approximately 90% over. But three constituets as amylalcohol, furfuryl acetate, and 2-methoxy-4-vinyl phenol(MVP) were detected only in domesticated species.

  • PDF

Degradation evaluation of paint films on surface treated steel by electrochemical impedance spectroscopy (전기화학적 임피던스 분광법에 의한 표면처리한 강재 도장의 부식-도막 열화도 평가)

  • Park, Jun-Mu;Park, Jae-Hyeok;Kim, Sun-Ho;U, Sang-Gyun;Gwon, Yong-Min;Mun, Gyeong-Man;Lee, Myeong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.95-95
    • /
    • 2018
  • 강재의 방식법 중 도장은 부식을 억제하는데 효과적이고 편리한 방법으로 선박 및 해양 강 구조물의 방식법으로 사용되고 있다. 한편, 강 구조물의 효율적인 유지관리를 위해서는 방식 도장의 도막 열화도를 평가하고 잔존 수명을 예측하여 최적 시기에 보수도장 혹은 재도장하는 것이 필요하다. 일반적으로 선박 및 해양구조물에 적용되는 도막의 방식 성능 평가 방법으로 해수 침지 시험, 염수 분무 시험, 옥외 폭로 시험 등이 있다. 그러나 이러한 시험들은 그 시험 방법에 따라서 정량적인 평가에 한계가 있음은 물론 장기간 소요되는 등 곤란한 문제점이 있다. 그러므로 선박 및 해양구조물을 비롯하여 교량, 각종 강 구조물의 도장 방식에 사용되는 방식용 도료의 성능을 단기간에 적절하게 평가할 수 있는 가속시험법이 제시되며 연구-사용되고 있다. 그 중 도막 방식 성능을 보다 효율적, 비파괴적, 정량적으로 평가할 수 있는 임피던스 분광법(EIS)과 같은 전기화학적 방법은 상대적으로 시험 기간을 크게 단축시킬 수 있고, 대상 방식 도장의 미세한 성능 차이도 분별 가능하다는 장점이 있다[1]. 따라서 본 연구에서는 선박 및 해양구조물 등 가혹한 부식환경에서 강력한 내구성을 가질 수 있도록 다양한 종류의 표면처리 도장 시편을 제작하여 자외선 조사-염수분무-침지환경 등의 열악한 환경조건 하에서 부식-열화 촉진 시험을 실시하였다. 그리고 그 촉진 열화 과정에서 도막의 외관 상태를 관찰 분석함은 물론 전기화학적 임피던스 분광법을 병행 측정하며 그 표면막의 부식 및 도막 열화도를 비교-종합 평가하였다.본 연구에 사용된 시편은 Al 및 Zn 도금 강판에 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편으로 Scribe, No Scribe 및 비교재 Al 및 Zn 도금 시편으로 분류하여 각각 실험을 진행하였다. 즉, 도막 열화 시험은 복합 노화 시험법으로 UV 조사 36 시간(ASTM G53), 염수분무 32 시간(ISO 7253), 수분 응축 10 시간을 1 Cycle로 100 Cycle(7800 시간) 동안 실험을 진행하였다. 이때 도막 열화도 평가는 전기화학적 임피던스 분광법을 이용하여 각 실험 조건별로 주파수에 따른 임피던스(Z) 값을 평가하였다. 즉, 상온 $25^{\circ}C$의 3.5% NaCl 100 ml 수용액에 작동 전극(Working Electrode)과 구리 도선을 통해 연결하였고, 노출 면적은 $1cm^2$로 일정하게 유지 하였으며, 상대 전극(Counter Electrode)은 탄소봉, 기준 전극(Reference Electrode)으로 포화카로멜전극(Saturated Calomel Electrode)을 사용하여 측정하였다. No Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편이 우수한 도막 저항성을 나타내었으며, 에폭시-우레탄 도장시편은 23사이클 이후의 저항값이 가장 낮게 나타났다. Zn 기판의 경우는 에폭시, 에폭시-실리콘 우레탄, 에폭시-우레탄 도장 시편 모두 저항 값이 유사하였으며, Al 및 Zn 도금 시편은 도장 처리된 시편에 비해 훨씬 낮은 저항 값을 보였다. 또한 Scribe 시편의 경우에는 Al 기판 에폭시-실리콘 우레탄 도장 시편에서 높은 초기 저항 값을 보였으며, 23 사이클 후의 저항 값은 세 종류의 도막에서 약 1~0.1 Gohm 으로 나타났다. 그리고 Zn 기판 에폭시-실리콘 우레탄 도장 시편에서 가장 낮은 도막 저항 값이 나타났다. 이상의 실험을 통해서 본 연구 내용은 실내촉진시험으로 선박 및 해양 강 구조물에 사용되는 다양한 종류의 도막의 열화도를 평가하는 기초 설계 지침으로 응용될 수 있을 것으로 사료된다. 한편, 도막은 노출 환경에 따라 방식 성능이 다르므로 실제 도막의 사용환경을 고려하여 도장 사양별 적용 부위에 따른 적정 가속 실험 방법을 선정할 필요가 있다고 사료된다.

  • PDF

Electrochemical Characterization of Anti-Corrosion Film Coated Metal Conditioner Surfaces for Tungsten CMP Applications (텅스텐 화학적-기계적 연마 공정에서 부식방지막이 증착된 금속 컨디셔너 표면의 전기화학적 특성평가)

  • Cho, Byoung-Jun;Kwon, Tae-Young;Kim, Hyuk-Min;Venkatesh, Prasanna;Park, Moon-Seok;Park, Jin-Goo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.61-66
    • /
    • 2012
  • Chemical Mechanical Planarization (CMP) is a polishing process used in the microelectronic fabrication industries to achieve a globally planar wafer surface for the manufacturing of integrated circuits. Pad conditioning plays an important role in the CMP process to maintain a material removal rate (MRR) and its uniformity. For metal CMP process, highly acidic slurry containing strong oxidizer is being used. It would affect the conditioner surface which normally made of metal such as Nickel and its alloy. If conditioner surface is corroded, diamonds on the conditioner surface would be fallen out from the surface. Because of this phenomenon, not only life time of conditioners is decreased, but also more scratches are generated. To protect the conditioners from corrosion, thin organic film deposition on the metal surface is suggested without requiring current conditioner manufacturing process. To prepare the anti-corrosion film on metal conditioner surface, vapor SAM (self-assembled monolayer) and FC (Fluorocarbon) -CVD (SRN-504, Sorona, Korea) films were prepared on both nickel and nickel alloy surfaces. Vapor SAM method was used for SAM deposition using both Dodecanethiol (DT) and Perfluoroctyltrichloro silane (FOTS). FC films were prepared in different thickness of 10 nm, 50 nm and 100 nm on conditioner surfaces. Electrochemical analysis such as potentiodynamic polarization and impedance, and contact angle measurements were carried out to evaluate the coating characteristics. Impedance data was analyzed by an electrical equivalent circuit model. The observed contact angle is higher than 90o after thin film deposition, which confirms that the coatings deposited on the surfaces are densely packed. The results of potentiodynamic polarization and the impedance show that modified surfaces have better performance than bare metal surfaces which could be applied to increase the life time and reliability of conditioner during W CMP.