• Title/Summary/Keyword: EHV

Search Result 154, Processing Time 0.024 seconds

Effect of arcing time on the interruption Performance of EHV class GCB (아크시간이 초고압 가스차단기의 차단성능에 미치는 영향)

  • Park, K.Y.;Shin, Y.J.;Song, K.D.;Chong, J.K.;Song, W.P.;Kwon, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.161-163
    • /
    • 1998
  • The interruption performance of EHV class gas circuit breakers critically depends on the flow conditions inside interrupter and the external circuit conditions. In case of puffer type gas circuit breakers the flow conditons are significantly influenced by arcing time. In this paper the calculated results of RRRV and pressure rise at current zero with varying arcing time are presented and the effect of arcing time on the thermal interruption performance of EHV class gas circuit breakers is analyzed.

  • PDF

Partial Discharge Diagnosis technology of EHV Underline Transmission XLPE cable applied FSA (FSA를 적용한 초고압 지중송전 XLPE케이블의 부분방전 진단기술)

  • Shin, D.H.;Lee, Y.S.;Yang, J.S.;Park, N.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.153-154
    • /
    • 2006
  • We studied the improved detecting method on Partial Discharge occurred in EHV power cable. In this field, we usually applied the several sensor for partial discharge. This is metal foil employed with the capacity foil-sensor. We detected the partial discharge through regularly array standard foil-sensor for the better improvement of existed foil-sensor in this research. This test is progressed in real EHV liveline, we analyzed that compare existed foil-sensor to detect character of FSA(Foil Sensor Array) for this test. From this result, detective character of fabricated FSA showed better result than existed foil-sensor.

  • PDF

Development of a 170kV 50kA Capacitorless Gas Circuit Breaker

  • Park, K. Y.;K. D. Song;Y. H. Oh;W. P. Song;J. H. Kang;Park, S. W.
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.3
    • /
    • pp.73-76
    • /
    • 2003
  • In modern EHV (Extra High Voltage) class GCBs (Gas Circuit Breakers), the interruption capability for SLF (Short Line Fault) is one of the most important aspects of performance required for GCBs. Up to now, the SLF interruption capability of EHV class GCBs was partially assisted by the adoption of capacitors able to decrease the dV/dt of the TRV (Transient Recovery Voltage), particularly the TRV on the line side. This paper describes the technique to increase the SLF interruption capability of EHV class GCBs as well as the procedure to develop capacitorless l70kV 50kA GCB.

A STUDY ON THE DESIGN, JOINTING, CHARACTERISTIC OF CONDENSER CONE OF SEALING-END FOR 154KV OF CABLE (154KV OF 종단 접속함용 CONDENSER CONE의 설계.접속.특성에 관한 연구)

  • Lee, H.S.;Oh, E.J.;Lee, K.B.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.621-623
    • /
    • 1993
  • This paper describes the research in condenser cone of sealing-end for 154kV oil-filled underground cable. We conducted the design based on the results of electric field analysis by electrostatics theory and FEM. In case that condenser cone type EB-A was compared with bell mouth type EB-A, the results of the AC and lightening impulse voltage test showed improvment of 10 percents.

  • PDF

The construction or 765kV test line (765kV 실규모 실증시험장 건설)

  • Cho, S.B.;Lee, D.I.;Kim, J.B.
    • Proceedings of the KIEE Conference
    • /
    • 1991.11a
    • /
    • pp.431-434
    • /
    • 1991
  • To develop the EHV transmission technology, the electrical environment problems such as Audible Noise etc. have been studied by the use of Corona Cage with artifical water spray equipment. However, this study has difficulties in simulating the amount of natural conditions. Therefore, We will plan to install full scale EHV test line to prove the measuring values of Corona Noise, and to selection of Conductors, Insulators, and to economical design, construction data.

  • PDF

The Effect Analysis of Series and Shunt Compensation Schemes for EHV Long Transmission Lines (직병렬보상방법에 의한 초고압장거리송전선로의 보상효과분석)

  • Chung, J.K.;Kang, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.224-227
    • /
    • 1997
  • This study discuss two subjects : maximization of transmission capability and regulation of voltages along line within the permissible bounds. Series and parallel line compensation methods have been applied for those purposes using capacitors and reactors. In this paper, the effect of series and shunt line compensation for symmetrical line is analyzed. The results obtained in this paper can be applied 765kV class EHV transmission system.

  • PDF

Tests of the arc-resistant characteristics of nozzle and arcing contact for EHV class GCB (초고압급 가스차단기용 노즐 및 아크접점의 내아크 특성시험)

  • Song, K.D.;Chong, J.K.;Park, K.Y.;Kweon, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07a
    • /
    • pp.89-93
    • /
    • 1997
  • Various types of nozzles and arcing contacts for EHV class GCB have been made to investigate the arc-resistant characteristics of them during short-circuit tests. The tested results are presented and analyzed to give useful information for GCB nozzle and contact manufacturers.

  • PDF

Protective Immune Reponses Induced by Non-infectious L-particles of Equine Herpesvirus Type-1: Implication of Cellular Immunity

  • Mohd Lila Mohd Azmi;Field, Hugh-John;Frazer Rixon;Lauchlan, John-Mc
    • Journal of Microbiology
    • /
    • v.40 no.1
    • /
    • pp.11-19
    • /
    • 2002
  • Mice immunized with equine herpesvirus type-1(EHV-1) L-particles skewed a significant increase (p<7.75) in serum antibody titers. Upon a booster dose four weeks lateral antibody titers increased significantly. Interestingly, immunization via intravenous or intramuscular route induced significantly higher (p<0.75) antibody titers. However, mice iummunized with UV-treated L-particles, visions or immunization via intranasal route induced lower antibody titers. Upon challenge inoculation with wildtype EHV-1, our data showed there was a poor correlation between antibody titers and protection against virus replication. Therefore, the role of cell-mediated immunity Inwards protection was investigated. As predicted, the strongest cell-mediated immunity, as measured by delayed-hypersensitivity test, was detected in mice immunized with live virus particles. The magnitude of cell-mediated immune response correlated with the efficacy of L-particles as immunizing agent. The highest efficacy, as indicated in mice immunized via intranasal routed was highly correlated with cell-mediated immunity. A similar phenomenon was also demonstrated in mice immunized intranasally with UV-treated L-particles. However, the degree of protection was reduced when mice immunized intravenously or intramuscularly with UV-treated L-particles. In conclusion, protection conferred in these animals was highly implicated by immune cells and the least by antibodies. The route of immunization and the nature of the antigen also contributed to the efficacy of L-particles as immunizing agent. In contrast to that of herpes simplex virus type 1, our data showed EHV-1 non-infectious L-particles are highly suitable for immunization of the host against EHV-1 disease.

Detection of equine herpesvirus type-1 in naturally aborted equine fetuses in Jeiu by polymerase chain reaction (제주도내 자연발생한 말유산태아에서 PCR을 이용한 Equine Herpesvirus Tyre-1 검출)

  • Moon, Hyuk;Kang, Wan-Cheul;Kim, Eun-Joo;Kim, Jin-Hoe;Ko, Hyun-Joo;Yang, Jae-Hyuk;Son, Won-Geun;Lee, Du-Sik
    • Korean Journal of Veterinary Service
    • /
    • v.24 no.1
    • /
    • pp.83-88
    • /
    • 2001
  • It is impotent to identify the causative agents of abortion in equine for minimizing the loss of breeding costs in equine Industry. Recently, the abortion has often occurred in equine herds and thus the purpose of the study was aimed at the identification of equine herpesvirus-1, one of the frequent pathogens to abortion, using polymerase chain reaction. Six fetuses to be aborted at nine to ten months in pregnancy reared in six herds were used in the study. Two primers in the PCR were made from glycoprotein B gene of EHV-1. The primers specific for EHV-1 amplified 1880 bp of PCR products from DNA extracts from thorax fluids, livers, lungs, and spleens of four in six aborted fetuses. Consequently, PCR could be applied to diagnose the abortion of EHV-1 and also confirmed to play a major role of the viral pathogen associated with equine abortion in Jeju island.

  • PDF

Effect of CNTs on Electrical Properties and Thermal Expansion of Semi-conductive Compounds for EHV Power Cables

  • Jae-Gyu Han;Jae-Shik Lee;Dong-Hak Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.603-608
    • /
    • 2023
  • Carbon black with high purity and excellent conductivity is used as a conductive filler in the semiconductive compound for EHV (Extra High Voltage) power cables of 345 kV or higher. When carbon black and CNT (carbon nanotube) are applied together as a conductive filler of a semiconductive compound, stable electrical properties of the semiconductive compound can be maintained even though the amount of conductive filler is significantly reduced. In EHV power cables, since the semi-conductive layer is close to the conductor, stable electrical characteristics are required even under high-temperature conditions caused by heat generated from the conductor. In this study, the theoretical principle that a semiconductive compound applied with carbon black and CNT can maintain excellent electrical properties even under high-temperature conditions was studied. Basically, the conductive fillers dispersed in the matrix form an electrical network. The base polymer and the matrix of the composite, expands by heat under high temperature conditions. Because of this, the electrical network connected by the conductive fillers is weakened. In particular, since the conductive filler has high thermal conductivity, the semiconductive compound causes more thermal expansion. Therefore, the effect of CNT as a conductive filler on the thermal conductivity, thermal expansion coefficient, and volume resistivity of the semiconductive compound was studied. From this result, thermal expansion and composition of the electrical network under high temperature conditions are explained.