• 제목/요약/키워드: EES

검색결과 81건 처리시간 0.024초

전기에너지 저장 시스템 국제 표준화 동향 (A Survey on the Standards of EES (Electrical Energy Storage) Systems)

  • 정상진;안윤영
    • 전자통신동향분석
    • /
    • 제34권2호
    • /
    • pp.101-109
    • /
    • 2019
  • Electrical energy storage (EES) systems store generated electricity in energy storage devices such as batteries and discharge the stored energy when necessary. Individual subsystems of the EES system are being standardized independently; however, a holistic understanding of the whole system is necessary because the EES system is large and complex. IEC TC 120 has developed international standards of EES systems. In this paper, EES systems standards in IEC TC 120, including the planning and installation of EES systems, are presented. Further, ongoing standardization for the application of EES systems to backup power and emergency support is described.

EES 프레임워크를 위한 하이브리드 생산설비 데이터 습득 시스템(HEDAS)의 설계 및 구현 (Design and Implementation of a Hybrid Equipment Data Acquisition System(HEDAS) for Equipment Engineering System(EES) Framework)

  • 김경배
    • 한국컴퓨터정보학회논문지
    • /
    • 제17권2호
    • /
    • pp.167-176
    • /
    • 2012
  • 본 논문은 장비엔지니어링 시스템(EES) 프레임워크에서 반도체와 광전자 제조장비를 위한 새로운 하이브리드 생산설비데이터 습득 시스템을 설계하고 구현한다. 장비엔지니어링 분야에서 장비로부터 수집되는 데이터 량이 급격히 증가하고 있다. 제안된 HEDAS(Hybrid Equipment Data Acquisition System)는 EES 프레임워크에서 발생하는 대용량의 실시간 데이터를 효율적으로 처리한다. 또한, 제안된 시스템은 실시간 EES 응용 뿐만 아니라 비실시간 EES 응용을 지원할 수 있다. 실시간 EES 응용을 위해서 HEDAS는 메모리 기반의 연속질의와 필터링 기술을 이용하여 고속의 실시간 처리를 수행한다. HEADS는 비 실시간 장비 데이터를 HEADS 기반의 데이터베이스 또는 기존의 데이터베이스에 선택적으로 저장할 수 있다. 특히, 급격하게 증가하는 장비 데이터에 대해 디스크 저장 비용을 절감하기 위해 타임스템프 기반의 압축 인덱싱과 질의처리 기법을 제공한다. HEDAS는 EES 프레임워크에서 대용량의 실시간 및 비 실시간 장비 데이터를 수집하여 다양한 EES 응용에 수집된 데이터를 전송할 수 있는 효율적인 시스템이다.

EES 기반 비상발전기의 타당성 연구 (A Study on Validity of EES based Emergency Generator)

  • 한혜승;정범진;손성용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.57-58
    • /
    • 2015
  • 본 논문은 기존의 디젤엔진 기반의 비상발전기와 EES 기반의 비상발전기의 장단점과 경제성을 토대로 EES기반 비상발전기의 도입이 타당한지에 대하여 분석하고자 하였다. 디젤엔진 기반의 비상발전기의 환경오염, 순시정전, 유지보수 등의 많은 문제들을 EES로 대체 함으로써 해결 또는 개선할 수 있다. 비상발전기와 EES의 경제성을 비교하여 EES 기반 비상발전기의 도입 타당성과 시기를 제시하였다.

  • PDF

수요관리용 3상 EES시스템의 성능시험 및 고찰 (Performance Test and Consideration of Three Phase EES System for Demand Side Management)

  • 이태승;이동주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.486-488
    • /
    • 2018
  • 본 연구에서는 3상 EES(전기에너지저장시스템: Electrical Energy Storage) 시스템의 성능시험에 관한 내용을 소개 및 분석하고, 시험데이터를 통한 시험방법의 적절성에 관한 의견을 제시한다. EES 시스템의 단체표준 규격을 검토하기 전에, 전력변환장치의 단체표준규격 (SPS-SGSF-025-4-1972 : 2016)과 EES 시스템의 일반사항 및 시험방법을 제시하는 단체표준 규격 (SGSF-025-5-1, SGSF-025-5-2)에 각각 명시된 형식시험 항목을 상호 비교 및 분석하고, EES 시스템의 형식시험 항목 중 특정 항목은 시험을 수행하여 결과 데이터를 분석하고 규격내의 평가기준 및 시험방법의 적절성 여부를 고찰하였다.

  • PDF

EES 제어를 위한 Micro-EMS 구현 및 실증 분석 (Implementation and Verification Analysis of Micro-EMS for Controlling EES)

  • 김광호;김규식
    • 전자공학회논문지
    • /
    • 제52권1호
    • /
    • pp.155-161
    • /
    • 2015
  • 스마트 그리드 확산사업으로 에너지 저장시스템의 보급이 활발히 이루어지고 있다. 대규모 EES(Electric Energy Storage system)의 경우 수용가에 설치된 BEMS(Building Energy Management System) 또는 BAS(Building Automation System)등과 연동하여 효율적인 제어가 가능하나 일반 주택에 설치되는 EES는 운전 및 제어를 위한 전문 인력이 없어 이를 원격에서 통합관리할 수 있는 시스템이 필요하다. 또한, 태양광 발전과 EES가 동시에 설치된 경우 태양광 발전이나 전력부하에 따라 효율적인 제어를 할 수 있는 소규모의 EMS(Energy Management System)가 필요하게 된다. 본 논문에서는 주택에 설치된 태양광 발전과 EES를 효율적으로 제어하기 위한 EMS를 구현하고 그 유용성을 실험을 통해 확인하였다.

간호대학생의 정서와 사회심리적 건강의 관련성 연구 (A Study on the Relations of the Emotional Experience, Expression and Psychosocial Well-being of Nursing Students)

  • 권영미
    • 한국간호교육학회지
    • /
    • 제7권2호
    • /
    • pp.183-195
    • /
    • 2001
  • The purpose of this study was to identity the relationship among emotional expression, emotional support, and psychosocial well-being, to analyze the factor affect the psychosocial well-being and to provide the data-based for effective development of emotional education program. The subjects for this study were 553 undergraduate college nursing students. The period of data collection was from 16 to 30, June, 2001. The instruments used for this study were emotional expressiveness scale (EES), ambivalence over emotional expressiveness questionnaire (AEQ), affect intensity measure (AIM), social support scale (SSS), and psychosocial well-being index (PWI). Data were analyzed by use of Descriptive Statistics, ANOVA, t-test, Stepwise multiple regression, Pearson's correlation coefficient with SPSS WIN program. The Major results were as follows: 1. The average score of items for the AIM, EES, AEQ were moderate at 3.8, 3.7 and 3.4. The level of SSS was high at 7.2 and PWI was low at 52.1. 2. Significant correlation were found between the AIM, EES, and AEQ. The EES was positively correlated with the SSS and negatively correlated with the PWI. On the other hand, the AEQ was positively associated with the PWI and negatively associated with the SSS. There was significantly negative correlation between the SSS and PWI. 3. In demographic characteristics, significant difference was shown only in the EES. The EES was significantly different according to grade. The difference in the SSS and PWI between 3groups were significant at the EES and AEQ. 4. Results from hierarchical multiple regression analysis indicated that the EES, AEQ, and AIM had influence on the SSS. And perceived the AEQ and SSS together explained 18.7% of variance in the PWI. The results of study provide evidence about the roles of emotion in psychosocial well-being. As a result, this study suggests that later study would be required to identify factors affect the psychosocial well-being and to develop the emotional education program to enhance emotional expression.

  • PDF

전력계통 주파수응답 기여도 기반의 전기저장장치 주파수추종서비스 유효용량 산정 (Effective Capacity Calculation of the Electrical Energy Storage providing the Primary Frequency Control Service based on the Contribution to the Frequency Response of Power Systems)

  • 임현옥;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1561-1567
    • /
    • 2017
  • This paper calculates the effective capacity of EES providing the primary frequency control service based on its contribution to the frequency response of the power system. The amount of governor response from conventional generators which can be replaced by the primary frequency control from EES keeping the frequency response of the power system is defined as the effective capacity. The proposed method for calculating the effective capacity of EES is verified through case studies employing Korean power system. Furthermore, the application of the effective capacity of EES to power system operation is also discussed.

실시간 시뮬레이터를 활용한 EES 기능분석 (Operational Characteristic Analysis of EES using Real-Time Simulator)

  • 박아련;류강열;이충우;강호현;강병관;고광수;오승훈;최은식;이윤재;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.504-505
    • /
    • 2014
  • In this paper, by using hardware in the loop(HIL) of the EES, which is an inverter of high-rated technique and analyze the function. By exchanging information between the simulation and system controller to be used in a live system, HIL approach, approach experimental is used to interpret the system mass analysis is not possible in a real system some. This paper presents the implementation of the EES and the RTDS DSP28335 is a real-time connection to the electrical signal, and to verify the actual system is difficult, it was possible to analyze the performance of the system. Thus, it is expected to contribute I raise the stability and reliability of the operation during the actual EES is built.

  • PDF

오미자(Schizandra chinensis) 추출물이 김치의 과숙억제에 미치는 영향 (Effect of Ethanolic Extract of Schizandra chinensis for the Delayed Ripening Kimchi Preparation)

  • 문영자;박선;성창근
    • 한국식품영양학회지
    • /
    • 제16권1호
    • /
    • pp.7-14
    • /
    • 2003
  • 오미자 에탄올 추출물의 항균활성을 조사하고, 오미자 추출물에 함유된 유기산을 분석하여 오미자 추출물 및 유기산을 첨가하여 제조한 김치의 이화학적 변화와 미생물학적 특성을 살펴본 결과는 다음과 같았다. 1.시중에 유통되는 김치에서 분리한 CS6은 김치의 숙성과 부패에 관여하는 미생물인 Lactobacillus plantarum으로 동정되었으며, 이 균주에 대해 오미자 ethanol 추출물은 항균활성을 보였다. 최소 저해농도는 62.5mg/$m\ell$이었고, 액체배지의 경우 0.5$\mu\textrm{g}$/$m\ell$ 첨가시 미생물의 증식을 완전히 저해하였다. 2. 오미자 ethanol 추출물을 첨가한 김치에서 미생물의 생육을 저해하여 산도는 증가하지 않았다. 0.5% 이하 첨가시에 색상에 영향을 미치지 않으며, 0.4% 첨가시에 맛에 영향을 주지 않았다. 3. 오미자 ethanol 추출물에 succinic acid, malic acid, tartaric acid, oxalic acid등이 포함되어 있었고, 이 중 가장 강한 항균활성을 보인 유기산은 succinic acid였으며, 이의 항균활성은 오미자 ethanol 추출물과 비슷한 저해효과를 보여주었다. 4. Succinic acid를 첨가한 김치의 경우, 미생물의 생육저해로 김치의 신선도 유지에 효과적으로 밝혀졌고, 배양말기까지 일정한 경도를 유지하였고, 역시 0.4% 이하 첨가시 맛에 큰 영향을 주지 않았다. 5. 오미자 ethanol 추출물은 $\beta$-amylase에 대해서는 낮은 저해율을 보였지만 $\alpha$-amylase, glucoamlase에 대해서 강한 저해효과를 나타내어 조직의 연화방지에 효과가 있을 것으로 생각된다. 6. 오미자 ethanol 추출물의 Avicelase 저해효과는 CMCase에 대한 저해효과보다 더 강했으며, 과숙김치에서의 경도 유지효과가 기대된다. 7. 연화와 직접적으로 관련된 효소로 생각되는 polygalacturonase에 대한 저해효과는 오미자 ethanol 추출물 25$\mu\textrm{g}$/$m\ell$ 첨가시에 66.7%의 저해율을 보였고, 30$\mu\textrm{g}$/$m\ell$ 첨가시에는 92.6%의 저해율을 보였으나, pectinesterase의 경우 15~30$\mu\textrm{g}$/$m\ell$ 첨가시에 15~20%의 낮은 저해율을 보였다.

Evaluation Algorithms for Multiple Function of Dispersed Electrical Energy Storage Systems

  • Son, Joon-ho;Choi, Sung-Sik;Rho, Dae-Seok
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2245-2253
    • /
    • 2018
  • With the increase of electrical consumption and the unbalance of power demand and supply, power reserve rate is getting smaller and also the reliability of the power supply is getting deteriorated. Under this circumstance, the electrical energy storage (EES) System is considered as one of essential countermeasure for demand side management. This paper proposes efficient evaluation algorithms of multiple functions for EES systems, especially the secondary battery energy storage systems, in the case where they are interconnected with the power distribution systems. It is important to perform the economic evaluation for the new energy storage systems in a quantitative manner, because they are very costly right now. In this paper, the multiple functions of EES systems such as load levelling, effective utilization of power distribution systems and uninterruptible power supply are classified, and then the quantitative evaluation methods for their functions are proposed. From the case studies, it is verified that EES systems installed at distribution systems in a dispersed manner have multiple functions involved with direct and indirect benefits and also they can be expected to introduce to distribution systems with respects to economical point of view.