• 제목/요약/키워드: EDG

검색결과 65건 처리시간 0.03초

Coil Spring & Viscose Damper System의 동적거동특성분석 (Mechanical Characteristics Analysis of Coil Spring & Viscous Damper System)

  • 김민규;전영선
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.471-478
    • /
    • 2006
  • This paper presents the results of experimental studies of the mechanical characteristics of the Coil Spring and Viscous Damper system. The Coil Spring and Viscous Damper systems were selected for the isolation of Emergency Diesel Generator (EDG) which is located in Nuclear Power Plant (NPP). The Coil Spring and Viscous Damper systems were developed for, the operating vibration isolation and seismic isolation for scaled Model EDG System. The damping properties of the viscous damper changes as the variation of velocity. As a results, nonlinear damping characteristics of viscous damper system were evaluated.

  • PDF

중수로형 원자력 발전소 비상디젤발전기 주기적 안전성 평가 (Periodic Safety Review of EDG for CANDU Type Nuclear Power Plant)

  • 하체웅;한성흠;임우상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.666_667
    • /
    • 2009
  • 원자력발전소의 비상전력계통은 소외정전 시 발전소 안전정지에 필요한 안전관리 설비에 비상전력을 공급하는 계통으로 비상전력계통 모선에 비상디젤발전기(Emergency Diesel Generator : EDG)가 설치되어 있다. 본 논문에서는 국내 중수로형 원자력 발전소에 대해서 최초로 주기적 안전성 평가(Periodic Safety Review : PSR)을 수행한 결과를 기술하였다.

  • PDF

면진된 모형 비상디젤발전기의 지진응답 실험 (Shaking Table Test of Isolated EDG Model)

  • 김민규;전영선
    • 한국지진공학회논문집
    • /
    • 제11권3호
    • /
    • pp.33-42
    • /
    • 2007
  • 본 연구에서는 원전내 주요 안전관련 기기중 비상디젤발전기를 대상으로 한 진동대 실험을수행하였다. 원전의 비상디젤 발전기는 원전 전체의 노심손상빈도에 미치는 영향이 매우 크며 또한 면진장치를 설치하여 지진력을 저감시킬 경우 큰 폭으로 노심손상빈도를 감소시킬 수 있으며, 가동중 발생하는 소음과 진동으로 인하여 주변 구조물과 기기에 영향을 미치기도 한다. 따라서 지진력 저감과 기계 진동의 저감효과를 동시에 고려하기 위한 면진장치를 적용하여 그 효과를 평가하여 보고자하였다. 면진장치로는 코일스프링과 점성 댐퍼가 결합된 형태의 면진장치를 선정하였다. 실험의 대상으로 하는 비상디젤발전기는 영광 5,6호기에 설치되어 있는 모델로서 축소모형을 제작하였으며, 제작된 모형에 적합한 코일스프링-점성댐퍼 시스템을 설계하여 제작하였다. 제작된 면진장치를 축소모형에 설치하여 설계지진을 이용한 진동대 시험을 수행하여 지진력 저감효과를 분석하였다 본 연구를 통하여 설계지진의 경우 20% 그리고 Scenario 지진의 경우 70% 까지의 지진력 저감이 가능한 것을 확인하였으며, 면진장치의 기계적 특성이 설계값과 일치하지 않음으로 인하여 실제 지진력 저감효과가 크게 변할 수 있음을 확인할 수 있었다.

리스크정보를 활용한 비상디젤발전기 허용정지시간 연장시 안전성평가 (Safety Assessment for Emergency Diesel Generator(EDG) Allowed Outage Time(AOT) Extension using Risk-informed)

  • 임혁순;김두현
    • 한국안전학회지
    • /
    • 제25권3호
    • /
    • pp.118-122
    • /
    • 2010
  • 원자력발전소의 운전 유연성 증대, 안전성 및 경제성 향상, 정비 부담을 완화하기 위해 비상디젤발전기의 허용정지시간 연장이 요구된다. 확률론적안전성평가(probabilistic safety assessment) 기법으로 현재의 비상디젤발전기의 허용정지 시간을 3일에서 7일, 10일, 14일로 연장시 안전성 영향을 평가하였다. 종합적으로 평가결과, 비상디젤발전기의 허용정지시간 연장시 EDG 점검 또는 정비기간 중 인적실수으로 인한 발전소 불시정지 예방 및 안전성을 향상 시키는 것으로 분석되었다.

Coil Spring & Viscous Damper System의 동특성분석 (Mechanical Characteristic Analysis of Coil Spring & Viscous Damper)

  • 김민규;전영선
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.19-26
    • /
    • 2007
  • 본 연구에서는 Coil Spring과 Viscous Damper 시스템의 동특성 분석을 위한 특성실험을 수행하였다. Coil Spring과 Viscous Damper 시스템은 원자력발전소 비상디젤발전기의 진동저감 및 지진력 저감을 위한 장치로 선정되었다. Viscous Damper 가진 속도에 따라서 그 특성이 다르게 나타나기 때문에 그 영향을 평가하여 진동저감과 지진력 저감효과를 동시에 고려할 수 있는 장치로서의 성능을 평가하고자 하는 것이다. 실험결과 수평방향의 경우 속도의존 비선형 거동이 두드러지게 나타나고 있는 반면 연직방향은 그러한 특성이 미미한 것으로 나타났다. 강성과 감쇠 모두 설계값보다 고평가 되고 있는 것으로 나타나서 전체 시스템의 면진 및 진동저감시 영향을 미칠 수 있는 것으로 나타났다.

원자력발전소 Tandem 형 비상디젤발전기의 최적 정비 방안 연구 (A study on the overhaul method for a Tandem type EDG on Nuclear Power Plant)

  • 한성흠;임우상;하체웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.2036-2037
    • /
    • 2008
  • An Emergency Diesel Generator (EDG) manufactured by a French company Wartsila SACM, is a tandem type engine, consisted of two 10 cylindered diesel engines on each side. Manual provided by the manufacturer states that engine bearing requires inspection every 15 years. However, it is difficult for an inspector to access through a manhole located in the lower compartment of engine. Furthermore, during a routine or scheduled maintenance, it is not possible to disassemble main engine bearing and crank shaft, and perform inspection. Two methodologies are suggested here to resolve the problem. One method is to lift the engine and partially perform the maintenance service, and the other method is to disassemble the engine completely and to perform maintenance service by the manufacturer. Pros and cons of two methodologies were thoroughly compared.

  • PDF

존 조정하에서의 AGV 고착 방지 (AGV Deadlock Avoidance Under Zone Control)

  • 임동순
    • 대한산업공학회지
    • /
    • 제26권4호
    • /
    • pp.392-401
    • /
    • 2000
  • In this work, a deadlock avoidance strategy is proposed in order to effectively handle conflicts and deadlocks occurring in zone-control AGV (Automated Guided Vehicle) systems. The basic idea is based on Capacity-designated Directed Graph (CDG) theory that was developed to avoid from deadlocks in manufacturing systems. However, to enforce the effectiveness of detecting impending and restricted deadlocks, AGV routings are explicitly described in Extended Directed Graph (EDG). From EDG, a non-conservative deadlock-avoidance strategy is derived. The superiority of the proposed strategy lies on the applicability to diverse AGV path configurations using zone control. Also, because of its insensibility and robustness, it can be effectively used when the system has randomness and stochastic nature.

  • PDF

비상디젤발전기 엔진 상태진단 초음파 탐촉자 개발 (Development of Ultrasonic Sensor for Engine Condition Diagnosis of EDG)

  • 이상국;최광희
    • 동력기계공학회지
    • /
    • 제17권4호
    • /
    • pp.31-35
    • /
    • 2013
  • The emergency AC power supply system of the nuclear power plant is designed to supply the power to the nuclear power plant at the emergency operating condition. The safety function of the diesel generator at the nuclear power plant is to supply AC electric power to the safety system whenever the preferred AC power supply is unavailable. The reliable operation of onsite standby diesel generator should be ensured by a condition monitoring system designed to maintain, monitor and forecast the reliability level of diesel generator. The purpose of this paper is to improve the existing ultrasonic sensor used for condition diagnosis of engine fuel pump and cylinder head for the accurate diagnosis in actual engine condition of emergency diesel generator(EDG). As a result of this study, we could design and develop much more reliable ultrasonic sensor than existing ones.

Dynamic reliability analysis framework using fault tree and dynamic Bayesian network: A case study of NPP

  • Mamdikar, Mohan Rao;Kumar, Vinay;Singh, Pooja
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1213-1220
    • /
    • 2022
  • The Emergency Diesel Generator (EDG) is a critical and essential part of the Nuclear Power Plant (NPP). Due to past catastrophic disasters, critical systems of NPP like EDG are designed to meet high dependability requirements. Therefore, we propose a framework for the dynamic reliability assessment using the Fault Tree and the Dynamic Bayesian Network. In this framework, the information of the component's failure probability is updated based on observed data. The framework is powerful to perform qualitative as well as quantitative analysis of the system. The validity of the framework is done by applying it on several NPP systems.