• 제목/요약/키워드: ED2

검색결과 1,287건 처리시간 0.029초

새로운 경구용 세팔로스포린의 약효평가 (Studies of Pharmacological Activity on New Oral Cephalosporins)

  • 나성범;김완주;지웅길
    • 약학회지
    • /
    • 제38권2호
    • /
    • pp.140-148
    • /
    • 1994
  • ${\beta}-Lactamase$ stability, chemotherapeutic activity, and pharmacokinetics of 7-[(Z)-2-(2-aminothiazole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyridyl)piperazinyl]thiocarbonylthiomethyl-3-cephem-4-carboxylic acid(CEN1), 7-[(Z)-2-(2-aminothiazole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyrimidyl)piperazinyl]thiocarbonylthiomethyl-3-cephem-4-carboxylic acid(CEN2), pivaloyloxymethyl-7-[(Z)-2-(2-aminothizaole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyridyl)piperazinyl]thiocarbonyl-thiomethyl-3-cephem-4-carboxylate(CEN1P), and pivaloyloxymethyl-7-{(Z)--2-(2-aminothizaole-4-yl)-2-methoxyiminoacetamido]-3-[4-(2-pyridyl)piperazinyl]thiocarbonyl-thiomethyl-3-cephem-4-carboxylate(CEN2P) were examined. CEN1, CEN2, CEN1P, and CEN2P were very stable to the ${\beta}-lactamase$ obtained from three strains(Enterobacter cloacae P99, Escherichia coli TEM, and Citrobacter freundii). Chemotherapeutic activities$(ED_{50})$ of CEN2 and CEN2P against experimental systemic infections due to Streptococcus pyogenes 77A and Escherichia coli 078 were superior to those of CEN1 and CEN1P, respectively. The $ED_{50}$ values of CEN1, CEN2 were 5.82 mg/kg, 0.89 mg/kg(s.c., S. pyogenes 77A) while those of CEN1P, CEN2P were 14.56mg/kg, 6.40mg/kg(p.o., S. pyogenes 77A), respectively. The pharmacokinetics of CEN1, CEN2, CEN1P, and CEN2P were investigated in mice and rats. In mice, peak blood levels of $1.25\;{\mu}g/ml$ were recorded within 20 min after oral administration of a single dose equivalent to 40 mg/kg CEN1P. Cmax of CEN1P was much higher than that of CEN1 in mice and rats. Oral absorption of CEN2P was much higher than that of CEN2.

  • PDF

폐종양 환자에서 방사선치료에 의한 폐손상 (Radiation-induced Pulmonary Damage in Lung Cancer Patients)

  • 정수미;최일봉;강기문;김인아;신경섭
    • Radiation Oncology Journal
    • /
    • 제11권2호
    • /
    • pp.321-330
    • /
    • 1993
  • Purpose: A retrospective analysis was performed to evaluate the incidence of radiation induced lung damage after the radiation therapy for the patients with carcinoma of the lung. Method and Materials: Sixty-six patients with lung cancer (squamous cell carcinoma 27, adenocarcinoma 14, large cell carcinoma 2, small cell carcinoma 13, unknown 10) were treated with definitive, postoperative or palliative radiation therapy with or without chemotherapy between July 1987 and December 1991. There were 50 males and 16 females with median age of 63 years (range: 33~80 years). Total lung doses ranged from 500 to 6,660 cGy (median 3960 cGy) given in 2 to 38 fractions (median 20) over a range or 2 to 150 days (median in days) using 6 MV or 15 MV linear accelerator. To represent different fractionation schedules of equivalent biological effect, the estimated single dose (ED) model, $ED=D{\dot}N^{-0.377}{\dot}T^{-0.058}$ was used in which D was the lung dose in cGy, N was the number of fractions, and T was the overall treatment time in days. The range of ED was 370 to 1357. The endpoint was a visible increase in lung density within the irradiated volume on chest X-ray as observed independently by three diagnostic radiologists. Patients were grouped according to ED, treatment duration, treatment modality and age, and the percent incidence of pulmonary damage for each group was determined. Result: In 40 of 66 patients, radiation induced change was seen on chest radiographs between 11 days and 314 days after initiation of radiation therapy. The incidence of radiation pneumonitis was increased according to increased ED, which was statistically significant (p=0.001). Roentgenographic changes consistent with radiation pneumonitis were seen in $100\%$ of patients receiving radiotherapy after lobectomy or pneumonectomy, which was not statistically significant. In 32 patients who also received chemotherapy, there was no difference in the incidence of radiation induced change between the group with radiation alone and the group with radiation and chemotherapy, among the sequence of chemotherapy No correlation was seen between incidence of radiation pneumonitis and age or sex. Conclusions: The occurrence of radiation pneumonitis varies. The incidence of radiation pneumonitis depends on radiation total dose, nature of fractionation, duration of therapy, and modifying factors such as lobectomy or pneumonectomy.

  • PDF

Preparation of N'-Substituted Anilino-N-Methyl-N-Nitorsoureas as Candidate Antitumor Agents

  • Kim, Jack-C;Kim, Yeon-Gweon;Min, Byoung-Tack;Park, Jin-Il
    • Archives of Pharmacal Research
    • /
    • 제17권6호
    • /
    • pp.420-423
    • /
    • 1994
  • Various N'-substituted anilino-N-methyl-N'-nitrosoureas(2a-n) were easily prepared from the reaction of substituted phenylhydraines $(3, 4-CH_3, {\;} 3-, {\;} 4-OCH_3, {\;} 3-, {\;} 4-F, {\;} 3, {\;} 4-Cl, {\;} 4-Br, {\;} 2-, {\;} 3-, {\;} 4-NO_2, 4-(NO_2)_2)$ with methyl isocyanate, followed by the nitrosation with 99% HCOOH and dry sodium lnitrite powder. Surprisingly, of these series of analogus, the anilino-nitrocosureas substituted with eletron-withdrawing nitro groups (2k-a) showed significantly low $ED_{30}$ values of $1.4-3.4 {\mu}g/ml.$ In addition, none of these copounds subtituted with electron-donating groups exhibited cytotoxicities.

  • PDF

전북지역 양돈장에서의 돼지 부종병 항체 및 톡신 양성률 조사 (Prevalence of antibody and toxin against edema disease from pig farms in Jeonbuk province)

  • 조선영;유정희;유영주;이한준;허진
    • 한국동물위생학회지
    • /
    • 제46권4호
    • /
    • pp.325-334
    • /
    • 2023
  • Edema disease (ED) in pigs is enterotoxemia caused by Shiga toxin type 2e (Stx2e)-producing Escherichia coli (STEC) and frequently occurs in young piglets. Therefore, ED causes enormous economic losses in pig farms. In this study, a modified Stx2e (mStx2e) antigen was expressed and purified using commercial E. coli expression system. Monoclonal antibody was serviced by Ynto Ab Inc., using Phage Display Technique. Anti-Stx2e antibodies in piglets were measured by indirect ELISA using mStx2e antigens. Naive Stx2e in piglets were detected by Sandwich ELISA using Stx2e-monoclonal antibodies and commercial Stx2e-polyclonal antibodies. Among 3,480 piglets, anti-Stx2e antibodies were observed in 2,573 piglets. The 49.4% among 830 piglet serum samples possessed 0.625 ㎍/mL or more of Stx2e proteins. The 18.3% of 830 sera had 0.313 ㎍/mL of Stx2e proteins. The 32.3% of 830 samples held 0.156 ㎍/mL or less of Stx2e proteins. These results show that indirect ELISA using mStx2e antigen and Sandwich ELISA using Stx2e-monoclonal and polyclonal antibodies can be useful to detect ED in piglets.

Semiautomatic Three-Dimensional Threshold-Based Cardiac Computed Tomography Ventricular Volumetry in Repaired Tetralogy of Fallot: Comparison with Cardiac Magnetic Resonance Imaging

  • Hyun Woo Goo
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.102-113
    • /
    • 2019
  • Objective: To assess the accuracy and potential bias of computed tomography (CT) ventricular volumetry using semiautomatic three-dimensional (3D) threshold-based segmentation in repaired tetralogy of Fallot, and to compare them to those of two-dimensional (2D) magnetic resonance imaging (MRI). Materials and Methods: This retrospective study evaluated 32 patients with repaired tetralogy of Fallot who had undergone both cardiac CT and MRI within 3 years. For ventricular volumetry, semiautomatic 3D threshold-based segmentation was used in CT, while a manual simplified contouring 2D method was used in MRI. The indexed ventricular volumes were compared between CT and MRI. The indexed ventricular stroke volumes were compared with the indexed arterial stroke volumes measured using phase-contrast MRI. The mean differences and degrees of agreement in the indexed ventricular and stroke volumes were evaluated using Bland-Altman analysis. Results: The indexed end-systolic (ES) volumes showed no significant difference between CT and MRI (p > 0.05), while the indexed end-diastolic (ED) volumes were significantly larger on CT than on MRI (93.6 ± 17.5 mL/m2 vs. 87.3 ± 15.5 mL/m2 for the left ventricle [p < 0.001] and 177.2 ± 39.5 mL/m2 vs. 161.7 ± 33.1 mL/m2 for the right ventricle [p < 0.001], respectively). The mean differences between CT and MRI were smaller for the indexed ES volumes (2.0-2.5 mL/m2) than for the indexed ED volumes (6.3-15.5 mL/m2). CT overestimated the stroke volumes by 14-16%. With phase-contrast MRI as a reference, CT (7.2-14.3 mL/m2) showed greater mean differences in the indexed stroke volumes than did MRI (0.8-3.3 mL/m2; p < 0.005). Conclusion: Compared to 2D MRI, CT ventricular volumetry using semiautomatic 3D threshold-based segmentation provides comparable ES volumes, but overestimates the ED and stroke volumes in patients with repaired tetralogy of Fallot.

How Effective Are Radiation Reducing Gloves in C-arm Fluoroscopy-guided Pain Interventions?

  • Kim, Ah Na;Chang, Young Jae;Cheon, Bo Kyung;Kim, Jae Hun
    • The Korean Journal of Pain
    • /
    • 제27권2호
    • /
    • pp.145-151
    • /
    • 2014
  • Background: The physician's hands are close to the X-ray field in C-arm fluoroscopy-guided pain interventions. We prospectively investigated the radiation attenuation of Proguard RR-2 gloves. Methods: In 100 cases, the effective doses (EDs) of two dosimeters without a radiation-reducing glove were collected. EDs from the two dosimeters-one dosimeter wrapped with a glove and the other dosimeter without a glove-were also measured at the side of the table (Group 1, 140 cases) and at a location 20 cm away from the side of the table (Group 2, 120 cases). Mean differences such as age, height, weight, radiation absorbed dose (RAD), exposure time, ED, and ratio of EDs were analyzed. Results: In the EDs of two dosimeters without gloves, there were no significant differences ($39.0{\pm}36.3{\mu}Sv$ vs. $38.8{\pm}36.4{\mu}Sv$) (P = 0.578). The RAD ($192.0{\pm}182.0radcm^2$) in Group 2 was higher than that ($132.3{\pm}103.5radcm^2$) in Group 1 (P = 0.002). The ED ($33.3{\pm}30.9{\mu}Sv$) of the dosimeter without a glove in Group 1 was higher than that ($12.3{\pm}8.8{\mu}Sv$) in Group 2 (P < 0.001). The ED ($24.4{\pm}22.4{\mu}Sv$) of the dosimeter wrapped with a glove in Group 1 was higher than that ($9.2{\pm}6.8{\mu}Sv$) in Group 2 (P < 0.001). No significant differences were noted in the ratio of EDs ($73.5{\pm}6.7%$ vs. $74.2{\pm}9.3%$, P = 0.469) between Group 1 and Group 2. Conclusions: Proguard RR-2 gloves have a radiation attenuation effect of 25.8-26.5%. The radiation attenuation is not significantly different by intensity of scatter radiation or the different RADs of C-arm fluoroscopy.

3.4-Diaryl-2(5H)-Furanone Derivatives: Synthesis. Cytotoxicity, and Antitumor Activity

  • Kim, Yong;Bang, Seong-Cheol;Ahn, Byung-Zun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.354.2-354.2
    • /
    • 2002
  • Fifty of 3.4-diaryl-2(5H)-furanone derivatives were synthesized and evaluated for their cytotoxicity in a small panel of cancer cell lines. Eleven compounds in this series, were found to have significant cytotoxic activities with ED$_{50}$ values of less than 1 4{\mu}$M in most of the cell lines tested. Compound RTMSI, 3-(3.4, 5-trimethoxyphenyl)-4-(3-amino-4-methylamino)-2(5H)-furanone exhibited the most potent cytotoxic activity with ED$_{50}$ value of 0.003 4{\mu}$M and antitumor activity on BDF1 mice bearing Lewis lung carcinoma cells with inhibition ratio of 72 %.%.

  • PDF

독서의 본질과 그 과정

  • 김효정
    • 도서관문화
    • /
    • 제31권3호통권262호
    • /
    • pp.28-35
    • /
    • 1990
  • 이 글은 Gray, W.S. Reading.ed by Guthrie J.T. I.R.A.1984. 중 제2장 Nature of Reading and Basic Involved의 완역임.

  • PDF