• Title/Summary/Keyword: ECG signal

Search Result 564, Processing Time 0.024 seconds

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF

Development of Respiration Monitor using Impedance Pneumograph (Impedance Pneumograph법을 이용한 호흡 감시장치의 개발)

  • 고한우;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.15-18
    • /
    • 1984
  • In this paper we developed a respiration monitor by an impedane pneumography. This technique, measuring the electrical impedance change of the lungs due to breath, provides the accurate data for the respiration trend and rates. To measure the small impedance difference we designed a special current source which was considered the electrical safety and the interference with the ECG signal.

  • PDF

Study on the Biomedical Signal Processing System (신호처리 알고리즘을 적용한 생체신호처리 시스템에 관한 연구)

  • 박차훈;김태선
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2001.05a
    • /
    • pp.252-255
    • /
    • 2001
  • The purpose of this study is to realize the real time monitoring ECG telemetry system applied by the telemetry unit, in which transmission is made through the electronic wave and reception is made through the light, and by the wavelet algorithm as well. A light receiver via existing telemetry unit which is based on baseband, the reception length was 50cm, but when the frequency modulation is used, the reception length is extended to 3m. In addition to this, we have found that the full-duplex method of transmission became available by using dual-mechanism.

  • PDF

A Study of the Atrial Arrhythmia Diagnosis Algorithm (심방성 부정맥 진단 알고리즘에 관한 연구)

  • 황선철
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.1
    • /
    • pp.17-24
    • /
    • 1989
  • This papaer presents a new algorithm for the P-wave detection in the ECG signal. Digital differentiation method (7-point derivative) is used for detecting P-waves exactly. This algorithm can detect various parameters of PR, PP, RR interval, which are important to diagnosis AV blocks and WPW syndrome. Especially, this algorithm can detect P-waves very efficiently not only in well-preprocessed waves but in pccr waves with noise and artifact. And it enables to develope more reliable automatic diagnosis algorithm.

  • PDF

청각 감성의 생리적 신호변화에 대한 연구

  • 황민철;김지은;김철중
    • Proceedings of the ESK Conference
    • /
    • 1996.04a
    • /
    • pp.259-263
    • /
    • 1996
  • Psychological action is physiological response of outernal stimulus. Physiological response is accompanied b physiological signals which are EEG, EMG, GSR, ECG, BP, and tec. Physiological signals are recently studied for determination of human phychological state. Psychological activity causes electric potential of brain. Physiological signal is considered as measurement of human psychological state. Aditory sensibility which is one of the sense of human may determine differences between positive and negative feeling. EEG and GSR variation with auditory quality of stimulus can be define human negative and positive mental state. This study is to characterize parameters which can determine negative and positive psycholigical state of human.

  • PDF

Noise Rejection of EMG Signals for the Control of Rehabilitation Robotic Am System (재활 로봇 팔 제어를 위한 근전도 신호의 잡음제거에 관한 연구)

  • 오승환;백승은;나승유;이희영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.65-68
    • /
    • 2001
  • In the rehabilitation robotic arm systems for the disabled with spinal code injury, EMG signals are used in the control of the robotic arm. EMG signals are corrupted by many kinds of noises such as ECG signal, power noise and contact noise of electrode. Noise rejection improves the performance of the EMG pattern classification. In this paper, a variable bandwidth filter (VBF) and wavelet transform are used for the noise rejection of EMG signals and the comparison of SNR is given. Also, some statistical characteristics of features are investigated.

  • PDF

Inhibition of Angiotensin II-Induced Vascular Smooth Muscle Cell Hypertrophy by Different Catechins

  • Zheng, Ying;Song, Hye-Jin;Yun, Seok-Hee;Chae, Yeon-Jeong;Jia, Hao;Kim, Chan-Hyung;Ha, Tae-Sun;Sachinidis, Agapios;Ahn, Hee-Yul;Davidge, Sandra T.
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.9 no.2
    • /
    • pp.117-123
    • /
    • 2005
  • A cumulative evidence indicates that consumption of tea catechin, flavan-3-ol derived from green tea leaves, lowers the risk of cardiovascular diseases. However, a precise mechanism for this cardiovascular action has not yet been fully understood. In the present study, we investigated the effects of different green tea catechins, such as epigallocatechin-3 gallate (EGCG), epigallocatechin (EGC), epicatechin-3 gallate (ECG), and epicatechin (EC), on angiotensin II (Ang II)-induced hypertrophy in primary cultured rat aortic vascular smooth muscle cell (VSMC). [$^3H$]-leucine incorporation was used to assess VSMC hypertrophy, protein kinase assay, and western blot analysis were used to assess mitogen-activated protein kinase (MAPK) activity, and RT-PCR was used to assess c-jun or c-fos transcription. Ang II increased [$^3H$]-leucine incorporation into VSMC. However, EGCG and ECG, but not EGC or EC, inhibited [$^3H$]-leucine incorporation increased by Ang II. Ang II increased phosphorylation of c-Jun, extracellular-signal regulated kinase (ERK) 1/2 and p38 MAPK in VSMC, however, EGCG and ECG , but not EGC or EC, attenuated c-Jun phosphorylation increased by Ang II. ERK 1/2 and p38 MAPK phosphorylation induced by Ang II were not affected by any catechins. Ang II increased c-jun and c-fos mRNA expression in VSMC, however, EGCG inhibited c-jun but not c-fos mRNA expression induced by Ang II. ECG, EGC and EC did not affect c-jun or c-fos mRNA expression induced by Ang II. Our findings indicate that the galloyl group in the position 3 of the catechin structure of EGCG or ECG is essential for inhibiting VSMC hypertrophy induced by Ang II via the specific inhibition of JNK signaling pathway, which may explain the beneficial effects of green tea catechin on the pathogenesis of cardiovascular diseases observed in several epidemiological studies.

Applying of SOM for Automatic Recognition of Tension and Relaxation (긴장과 이완상태의 자동인식을 위한 SOM의 적용)

  • Jeong, Chan-Soon;Ham, Jun-Seok;Ko, Il-Ju;Jang, Dae-Sik
    • Journal of the Korea Society of Computer and Information
    • /
    • v.15 no.2
    • /
    • pp.65-74
    • /
    • 2010
  • We propose a system that automatically recognizes the tense or relaxed condition of scrolling-shooting game subject that plays. Existing study compares the changed values of source of stimulation to the player by suggesting the source, and thus involves limitation in automatic classification. This study applies SOM of unsupervised learning for automatic classification and recognition of player's condition change. Application of SOM for automatic recognition of tense and relaxed condition is composed of two steps. First, ECG measurement and analysis, is to extract characteristic vector through HRV analysis by measuring ECG after having the player play the game. Secondly, SOM learning and recognition, is to classify and recognize the tense and relaxed conditions of player through SOM learning of the input vectors of heart beat signals that the characteristic extracted. Experiment results are divided into three groups. The first is HRV frequency change and the second the SOM learning results of heart beat signal. The third is the analysis of match rate to identify SOM learning performance. As a result of matching the LF/HF ratio of HRV frequency analysis to the distance of winner neuron of SOM based on 1.5, a match rate of 72% performance in average was shown.

The changes of electrocardiography and signal-averaged electrocardiography after surgical repair of Tetralogy of Fallot (활로씨 4징의 교정 수술 후 심전도와 신호 평준화 심전도의 변화)

  • Seo, Hye-Eun;Lim, Hae-Ri;Kim, Yeo-Hyang;Hyun, Myung-Chul;Lee, Sang-Bum
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.5
    • /
    • pp.462-468
    • /
    • 2007
  • Purpose : The purpose of this study was to analyze the changes of the late potential of Signal- averaged electrocardiography (SAECG) and Electrocardiography (ECG) parameters during follow up of those who had taken surgical repair of Tetralogy of Fallot (TOF). Methods : Nine patients who had taken surgical repair of TOF since 1985 checked SAECG and standard 12 leads ECG twice in 1999 and 2005 in Kyungpook national university hospital. We evaluated changes of QRS duration, QT interval and JT interval, QRS dispersion, QT dispersion and JT dispersion of standard 12 leads ECG and Filtered QRS (f-QRS), High frequency low amplitude potential (HFLA), Root mean square in terminal 40 ms (RMS) and Mean voltage in terminal 40 ms (MV) of SAECG between in 1999 and 2005. Results : There were significant decrease of JT dispersion ($101.11{\pm}50.11$ vs $71.11{\pm}22.61ms$, P< 0.05) and significant increase of HFLA ($24.67{\pm}13.19$ vs $32.89{\pm}14.21ms$, P<0.05). But there were no significant changes in other parameters. Conclusion : In repaired TOF patients, we evaluated ECG and SAECG to detect possible late complications such as tricuspid regurgitation, right ventricular enlargement, ventricualar arrythmia and sudden death. And there were significant changes of ECG and SAECG in some parameters (JT dispersion, HFLA). But to see the relationships between the changes of these parameters and the long term prognosis, we need to check more patients and longer follow-up.

The Unconstrained Sleep Monitoring System for Home Healthcare using Air Mattress and Digital Signal Processing (공기 매트리스와 디지털 신호처리를 이용한 홈헬스케어용 무구속 수면 모니터링 시스템)

  • Chee, Young-Joon;Park, Kwang-Suk
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.493-496
    • /
    • 2005
  • For home healthcare, the unconstrained measurement of physiological signal is highly required to avoid the inconvenience of users. The recording and analysis of the fundamental parameters during sleep like respiration and heart beat provide valuable information on his/her healthcare. Using the air mattress sensor system, the respiration and heart beat movements can be measured without any harness or sensor on the subject's body. The differential measurement technique between two air cells is adopted to enhance the sensitivity. The balancing tube between two air cells is used to increase the robustness against postural changes during the measurement period. The meaningful frequency range could be selected by the pneumatic filter with balancing tube. ECG (Electrocardiography) and respiration sensor (plethysmography) were measured for comparison with the signal from air mattress. To extract the heart beat information from air pressure sensor, digital signal processing technique was used. The accuracy for breathing interval and heart beat monitoring was acceptable. It shows the potentials of air mattress sensor system to be the unconstrained home sleep monitoring system.

  • PDF