• 제목/요약/키워드: ECG analysis system

검색결과 170건 처리시간 0.024초

뇌파와 심전도 분석을 통한 색채와 색온도가 주거공간에서의 집중도에 미치는 영향 (Effect of Color and Color Temperature on the Attention in the Residential Space by the Analysis of EEG and ECG)

  • 김영중;지두환;류영재;김성현;서상혁;곽승현;강진규;민병찬
    • 산업경영시스템학회지
    • /
    • 제40권1호
    • /
    • pp.124-130
    • /
    • 2017
  • This study is aimed to find out whether there is difference in the physiological change of a human body according to the illumination and color of interior space or not and to specify the effect of the condition of illumination and color, respectively on the attention. In order to do so, White and Green were selected for colors and 4,000k, 5,000k, and 6000k were done for color temperature, and then attention was identified. Examining the results, the more color temperature increased, the more attention improved (P < 0.05), and in the case of EEG, ${\alpha}$ wave decreased while performing the task of attention (P < 0.01), and ${\beta}$ wave decreased more in Green than White in color condition, and it increased more in 4,000k than 5,000k and 6,000k (p < 0.05) in color temperature condition. To sum up, color condition didn't contribute to the attention much, in the case of color temperature, when it is 6,000k, it is judged that it helped to improve attention. It is considered that relaxation contributed to improving attention, as ${\beta}$ wave and sympathetic nerve decreased in 6,000k (p < 0.05). It is judged that the relaxation of tensions which happened due to a beta wave and the reduction of sympathetic nervous system activity in 6,000k, a condition of high color temperature, contributed to the improvement of concentration. In further researches, it is intended that a test will be conducted for the subjects of different ages, and the correlation between color temperature and color stimulation and the influence of them on human body would be observed in subdivided, various test conditions through various color temperature and color stimulation.

자동차 그래픽 시뮬레이터에서 사이렌 소리 자극에 따른 청각 자극의 마스킹 효과 (The Ability of Auditory Stimuli to Mask Siren Sounds in a Vehicle Graphic Simulator)

  • 박정순;김규범;조형석;김경래;김형준;민병찬
    • 감성과학
    • /
    • 제22권3호
    • /
    • pp.47-54
    • /
    • 2019
  • 본 연구는 운전 중 외부 소음으로 유발된 스트레스를 줄이기 위한 방법으로 심박변화율의 상관관계 분석의 선행연구와 음원의 주파수에서 운전자로 하여금 안정상태를 유발하는 음악과 소음 발생 시 심전도의 변화 가 있는 지의 여부를 규명하기 위한 목적이다. 매년 자동차의 증가로 인하여 운전자 및 동승자가 외부 소음으로부터 스트레스가 증가하는 추세이다. 자동차 운전 시 외부 소음에 의한 스트레스는 불안, 면역약화, 우울, 심장 질환 등 여러 가지 질병을 일으키고 있다. 따라서 외부 소음으로부터 스트레스를 줄이기 위한 자동차 시뮬레이터를 실시하여 여러 가지 청각 자극을 주어 운전자가 반응하는 연구를 진행하였다. RM-ANOVA (Repeated Measures-ANOVA) 통계분석 결과, 집단별 유의차가 인정되었다(ρ<0.05). 사후 검정을 통해 어떤 요인 간의 차이가 발생하는지를 알아보았다. 사후검정 결과는 요인1(안정)과 요인2(시뮬레이션운전), 요인1(안정)과 요인3(운전+경찰사이렌), 요인1(안정)과 요인4(운전+경찰사이렌+음악)에서 유의한 차이를 발견할 수 있었다. 또한, 교감신경계 활성도가 가장 높은 집단은 운전+경찰사이렌+음악을 실시한 요인 4이며, 다음으로 운전+경찰사이렌인 요인 3이며, 다음으로 운전을 실시한 요인 2, 마지막으로 안정기 순으로 나타났다. 결론적으로 운전 중 경찰 사이렌 소리를 들려주어도 심전도의 변화는 유의차가 인정되지 않았다. 또한, 사이렌 소리에 안정된 주파수의 음악을 들려주어도 심전도의 변화에 차이가 발생하지 않았다(ρ<0.01). 향후 연구에서는 운전 중 심전도의 안정을 찾을 수 있는 여러 가지 음악을 들려주어서 심전도가 안정화되는 음악을 찾는 연구방법이 선행되어야 할 것이다.

Hilbert-Huang 변환을 이용한 제세동 성공 예측 (Prediction of the Successful Defibrillation using Hilbert-Huang Transform)

  • 장용구;장승진;황성오;윤영로
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.45-54
    • /
    • 2007
  • 시/주파수 분석은 생체 신호 처리에서 널리 사용되어왔다. 전기 생리학적 신호로부터 중요한 특징들을 추출함으로써 이 방법들은 특정 질병의 임상 병리학적 기전 해석이 가능하다. 하지만 이 방법은 신호가 안정하다는 가정 아래 적용되었으며 불안정한 시스템에서의 적용은 제한이 되어 있다. 본 연구에서는 비선형적이고 비정상적인 심실세동 심전도 파형의 분석을 위해 Hilbert-Huang 변환을 사용한 새로운 신호처리 방법을 제안하였다. Hilbert-Huang 변환은 경험모드분리법(EMD)과 힐버트 변환으로 크게 두 가지로 구성된다. Hilbert-Huang 변환은 EMD를 사용하여 각각의 특성을 지니고 있는 독립적인 내부모드함수들로 나누어지며, 힐버트 변환에 의해 순간 주파수와 크기를 구할 수 있게 된다. 이런 특성으로 신호의 국부적인 작용에 대하여 정확하게 설명할 수 있게 된다. 본 연구에서는 Hilbert-Huang 변환을 기반으로 심실세동 심전도 파형으로부터 두 종류의 파라미터(EMD-IF, EMD-FFT)를 추출하고 서포트 벡터 머신(Support Vector Machine)을 이용하여 소생성공 및 실패 여부 예측에 관하여 연구하였다. 평균적으로 민감도와 특이도는 각각 87.57%와 76.92%로 나타났다. Hilbert-Huang 변환은 더욱 정확하게 심실세동에서의 소생성공 예측을 가능하게 하였다.

편백나무로 제작된 힐링 침대에서의 색체 자극이 스트레스 완화에 미치는 효과 (The Effect of Stress Reduction on Color Stimulus Using Healing Bed in Cypress Tree)

  • 신선혜;유미;오승용;김주리;송의선;문명철;임승택;박희준;권대규
    • 재활복지공학회논문지
    • /
    • 제10권2호
    • /
    • pp.163-170
    • /
    • 2016
  • 본 연구에서는 삼림욕을 즐기는 것과 같은 편안한 상태의 휴식을 유도하기 위하여 편백나무를 이용하여 힐링 침대 시스템과 색체자극을 위한 LED 감성 모듈을 개발하였고, 8가지 조명과 3가지 색온도의 색체 자극에 따른 휴식이 스트레스 완화에 미치는 효과를 비교 분석하였다. 피험자는 건강한 20대 성인 남여 7명(age $23.3{\pm}0.7yr$; height $165{\pm};10cm$ body mass $59{\pm}10kg$)을 대상으로 하였으며, 8가지 색상(red, orange, yellow, green, blue, indigo, violet, white)과 3가지 색온도(3,000K, 5,000K, 8,000K)에 따른 휴식 시 심박변이도, 피험자의 주관적 인지평가를 진행하였다. 그 결과, 심박변이도의 경우 한색계열인 green, blue, indigo의 조명과 3000K의 낮은 온도 조명이 부교감신경을 활성화시켜 심리적으로 안정되는 결과를 얻었으며, 피험자가 주관적으로 느끼는 인지시간의 결과 동일 시간을 자극받았을 지라도 green 색상과 3,000K 온도 자극 시 인지 시간이 가장 느렸으며, 감성어휘 평가에서는 orange 색상과 3,000K온도에서 가장 높은 점수를 얻었다. 따라서, 본 연구 결과 3,000K의 낮은 온도자극과 green 색상 자극 시 심리정 안정이 가장 높은 결과를 얻었으며, 추후 연구에서는 작업 환경에 따른 조명 자극 시 피로도 회복과 뇌파 변화를 비교 분석 할 것이다.

광학 센서를 이용한 비관혈적 혈압 측정의 오차 보정 (Compensation of Error in Noninvasive Blood Pressure Measurement System Using Optical Sensor)

  • 고재일;정인철;이동희;박신우;황성오;박소미;김기연;주현실;윤형로
    • 대한의용생체공학회:의공학회지
    • /
    • 제28권2호
    • /
    • pp.178-186
    • /
    • 2007
  • This study is attempted to correct an error of electronic blood pressure meter with an optical sensor. In general, for a hospitalized patient, ECG, blood pressure, oxygen saturation, and respiration are basically measured to monitor the patient's condition. Opening of a blood vessel after it is occluded by pressurizing the cuff influences the blood flow of peripheral blood vessels as well as oscillation changes in the cuff. Blood vessels are occluded and peripheral blood flow disappears at cuff pressure above the examinee's blood pressure, while blood vessels are opened and peripheral blood flow appears again at cuff pressure under the examinee's blood pressure. Then Disappear-Appear Point Length(DAPL) of peripheral blood flow can be judged with the signal of peripheral blood flow, thus is available as a factor of error correction for electronic blood pressure meter. Also, systolic or diastolic blood pressure can be corrected with Appear-Point-Pressure(APP) of cuff pressure at a point where blood flow occurs and Appear-Maximum Pressure(AMP) of cuff pressure at the maximum amplitude point of peripheral blood flow after peripheral blood flow appears again. For verification, 27 examinees were selected, and their blood value was obtained through experimental procedure of 4 stages including induction of blood pressure change. The examinees were divided into two groups of experimental group and control group, regression analysis was conducted for experimental group, and correction of a blood pressure error was verified with optical signal by applying the regression equation calculated in experimental group to control group. As an experimental result, mean of the whole measurement errors was 5mmHg or more, which did not meet the standard fur blood pressure meter. As a result of correcting blood pressure measurements with data of DAPL, APP, and AMP as drawn out of PPG signal, systolic blood pressure, mean blood pressure, and diastolic blood pressure were $-0.6{\pm}4.4mmHg,\;-1.0{\pm}3.9mmHg$ and $-1.3{\pm}5.4mmHg$, respectively, indicating that mean of the whole measurement errors was greatly improved, and standard deviation was decreased.

지능형 교통체계 기반 인간-기계 인터페이스 시스템 평가를 위한 정신적부하 측정방법의 비교 연구 (Comparative Study of Subjective Mental Workload Assessment Techniques for the Evaluation of ITS-oriented Human-Machine Interface Systems)

  • Cha, Doo-Won;Park, Peom
    • 대한교통학회지
    • /
    • 제19권3호
    • /
    • pp.45-58
    • /
    • 2001
  • 교통시스템 및 차량의 인간-기계 상호작용 및 인간공학적 평가에 널리 사용되는 운전자의 시각행위분석, 생체신호측정(심박수, 호흡수, 뇌파, 피부전기반사 등), 부가작업의 수행도분석, 반응시간 분석, 차량조작변수 분석(속도, 핸들조작, 가속페달조작) 등의 방법들과 함께 운전자 판단에 의한 주관적평가(Subjective Mental Workload Assessment)는 기존 시스템의 평가뿐만 아니라, ITS(Intelligent Transport Systems) 기반 인간-기계 시스템(항법장치, Head-UP Display, AHS Flat Panel Display, Changeable Message Sign, Cellular Phone, 등)의 인간-기계 상호작용 평가, 안전도 평가, 경쟁시스템 및 디자인 대안의 의사결정, 설계가이드라인 제작 등을 위한 하나의 표준화된 평가도구로 자리 잡고 있다. 이에 본 연구에서는 가장 많은 적용빈도와 효과 및 감도를 제시하는 주관적 평가방법인 NASA-TLX (National Aeronautics and Space Administration-Task Load Index), SWAT(Subjective Workload Assessment Technique), MCH(Modified Cooper-Harper) scale, RNASA-TLX(Revision of NASA-TLX)를 대상으로 항법 장치를 사용한 운전자 부하 비교평가 실험결과를 이용하여, 제시된 방법들의 감도 및 피 실험자의 주관적 판단을 통한 상호 비교분석을 실시하였으며, 결과로 위에 제시된 방법들의 사용가이드라인과 ITS 기반 인간-기계 시스템의 인간공학적 평가를 위한 주관적 평가방법의 비교평가결과를 제시하였다.

  • PDF

다중 생체 신호를 통한 손목 혈압 측정의 정확도 향상 (Improvement of the Accuracy of Wrist Noninvasive Blood Pressure Measurement Using Multiple Bio-signals)

  • 정운모;심명헌;정상오;김민용;윤찬솔;정인철;윤형로
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1606-1616
    • /
    • 2011
  • The blood pressure measuring equipment, which is being supplied and used most widely by being recognized convenience and accuracy now generally, is oscillometric blood pressure monitor. However, a change in blood pressure is basically influenced by diverse elements such as each individual's physiological status and physical condition. Thus, the measurement of blood pressure, which used single element called oscillation in blood pressure of being conveyed to cuff, is not considered on physiological elements such as cardiovascular system status and blood vessel stiffness index, and on external elements, thereby being quite in error. Accordingly, this study detected diverse bio-signals and body informations in each individual as the measurement subject such as ECG, PPG, and Korotkoff Sound in order to enhance convenience and accuracy of measuring blood pressure in the complex measurement equipment, thereby having extracted regression method for compensation in error of oscillometric blood pressure measurement on the wrist, and having improved accuracy of measuring blood pressure. To verify a method of improving accuracy, the blood pressure value in each of SBP, DBP, MAP was acquired through 4-stage experimental procedure targeting totally 51 subjects. Prior to experiment, the subjects were divided into two groups such as the experimental group for extracting regression method and the control group for verifying regression method. Its error was analyzed by comparing the reference blood pressure value, which was obtained through the auscultatory method, and the oscillometric blood pressure value on the wrist. To reduce the detected error, the blood pressure compensation regression method was calculated through multiple linear regression analysis on elements of blood pressure, individual body information, PTT, HR, K-Sound PSD change. Verification was carried out on improving significance and accuracy by applying the regression method to the data of control group. In the experimental results, as a result of confirming error on the reference blood pressure value in SBP, DBP, and MAP, which were acquired through applying regression method, the results of $-0.47{\pm}7.45$ mmHg, $-0.23{\pm}7.13$ mmHg, $0.06{\pm}6.39$ mmHg could be obtained. This is not only the numerical value of satisfying the sphygmomanometer reference of AAMI, but also shows the lower result than the numerical value in SBP : $-2.5{\pm}12.2$ mmHg, DBP : $-7.5{\pm}8.4$ mmHg, which is the mean error in the experimental results of Brram's research for verifying accuracy of Omron RX-M, which shows relatively high accuracy among wrist sphygmomanometers. Thus, the blood pressure compensation could be confirmed to be made within significant level.

사향소합원(麝香蘇合元)이 정상인의 심박변이도에 미치는 영향 (The Effect of Sahyangsohapwon on Heart Rate Variability of Healthy Subjects)

  • 김창현;황재웅;민인규;김미영;변형식;나병조;박성욱;박정미;고창남;배형섭;정우상;문상관;조기호;김영석
    • 대한한의학회지
    • /
    • 제30권1호
    • /
    • pp.120-127
    • /
    • 2009
  • Objectives: Sahyangsohapwon (SS) is a herbal medication that has been widely used with circulatory and neural diseases. This study was conducted to assess the effect of SS on the autonomic nervous system by using heart rate variability measurement. Methods: The eligible subjects were enrolled from the healthy male group of ages 20 to 35 years. They were divided into two groups, the SS group (n=26) and the control (n=24). We monitored the ECG of subjects from the time period 14:00 to 18:00. In the SS group, subjects were administered with a dose of SS at the time 15:00, whereas the control group had none. For each hour HRV measurement was monitored every 15 minutes for 512 seconds from the time period 14:00 to 18:00. The mean value, which was calculated using the 4 values during each hour (i.e. 14:00, 14:15, 14:30, 14:45), was used as the representative value for each individual hour. For the measurement values, RR-interval and SDNN (standard deviation of the NN intervals) were used as time domain analysis, and HF (high frequency), LF (low frequency), and LF/HF ratio were used as frequency domain analysis. Results: The LF value showed an increase after one hour of SS administration and showed gradual diminution for each and every hour. The repeated measures of ANOVA for the comparison of the LF value between the SS group and the control group showed significant differences. While, RR interval, SDNN, HF, and LF/HF ratio values showed no significant differences between the two groups. Conclusions: We suggest that the SS might be useful for stabilizing autonomic nervous system by inhibiting sympathetic nerve activation in healthy people.

  • PDF

Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects

  • Im Jae-Joong;Lee, Nak-Bum;Rhee Moo-Yong;Na Sang-Hun;Kim, Young-Kwon;Lee, Myoung-Mook;Cockcroft John R.
    • International Journal of Vascular Biomedical Engineering
    • /
    • 제4권2호
    • /
    • pp.19-24
    • /
    • 2006
  • Background: Pulse wave velocity (PWV), which is inversely related to the distensibility of an arterial wall, offers a simple and potentially useful approach for an evaluation of cardiovascular diseases. In spite of the clinical importance and widespread use of PWV, there exist no standard either for pulse sensors or for system requirements for accurate pulse wave measurement. Objective of this study was to assess the reproducibility of PWV values using a newly developed PWV measurement system in healthy subjects prior to a large-scale clinical study. Methods: System used for the study was the PP-1000 (Hanbyul Meditech Co., Korea), which provides regional PWV values based on the measurements of electrocardiography (ECG), phonocardiography (PCG), and pulse waves from four different sites of arteries (carotid, femoral, radial, and dorsalis pedis) simultaneously. Seventeen healthy male subjects with a mean age of 33 years (ranges 22 to 52 years) without any cardiovascular disease were participated for the experiment. Two observers (observer A and B) performed two consecutive measurements from the same subject in a random order. For an evaluation of system reproducibility, two analyses (within-observer and between-observer) were performed, and expressed in terms of mean difference ${\pm}2SD$, as described by Bland and Altman plots. Results: Mean and SD of PWVs for aorta, arm, and leg were $7.07{\pm}1.48m/sec,\;8.43{\pm}1.14m/sec,\;and\;8.09{\pm}0.98m/sec$ measured from observer A and $6.76{\pm}1.00m/sec,\;7.97{\pm}0.80m/sec,\;and\;\7.97{\pm}0.72m/sec$ from observer B, respectively. Between-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.14{\pm\}0.62m/sec,\;0.18{\pm\}0.84m/sec,\;and\;0.07{\pm}0.86m/sec$, and the correlation coefficients were high especially 0.93 for aortic PWV. Within-observer differences ($mean{\pm}2SD$) for aorta, arm, and leg were $0.01{\pm}0.26m/sec,\;0.02{\pm}0.26m/sec,\;and\;0.08{\pm}0.32m/sec$ from observer A and $0.01{\pm}0.24m/sec,\;0.04{\pm}0.28m/sec,\;and\;0.01{\pm}0.20m/sec$ from observer B, respectively. All the measurements showed significantly high correlation coefficients ranges from 0.94 to 0.99. Conclusion: PWV measurement system used for the study offers comfortable and simple operation and provides accurate analysis results with high reproducibility. Since the reproducibility of the measurement is critical for the diagnosis in clinical use, it is necessary to provide an accurate algorithm for the detection of additional features such as flow wave, reflection wave, and dicrotic notch from a pulse waveform. This study will be extended for the comparison of PWV values from patients with various vascular risks for clinical application. Data acquired from the study could be used for the determination of the appropriate sample size for further studies relating various types of arteriosclerosis-related vascular disease.

  • PDF

간호교육기관의 실험실습설비 보유실태 조사 (A Survey on the Actual State of Laboratory Facilities and Equipments at Nursing Schools)

  • 임난영;이선옥;서문자;김혜숙;김문실;오경옥
    • 대한간호
    • /
    • 제36권1호
    • /
    • pp.108-117
    • /
    • 1997
  • This study was carried out to examine the standards for evaluation of laboratory facilities and equipment. These constitute the most important yet vulnerable area of our system of higher education among the six school evaluation categories provided by the Korean Council for University Education. To obtain data on the present situation of holdings and management of laboratory facilities and equipment at nursing schools in Korea, questionnaires were prepared by members of a special committee of the Korea Nursing Education Society on the basis of the Standards for University Laboratory Facilities and Equipment issued by the Ministry of Education. The questionnaires were sent to nursing schools across the nation by mail on October 4, 1995. 39 institutions completed and returned the questionnaires by mail by December 31 of the same year. The results of the analysis of the survey were as follows: 1. The Physical Environment of Laboratories According to the results of investigation of 14 nursing departments at four-year colleges, laboratories vary in size ranging from 24 to 274.91 pyeong ($1{\;}pyeong{\;}={\;}3.3m^2).$. The average number of students in a laboratory class was 46.93 at four-year colleges, while the number ranged from 40 to 240 in junior colleges. The average floor space of laboratories at junior colleges, however, was almost the same as those, of laboratories at four-year colleges. 2. The Actual State of Laboratory Facilities and Equipment Laboratory equipment possessed by nursing schools at colleges and universities showed a very wide distribution by type, but most of it does not meet government standards according to applicable regulations while some types of equipment are in excess supply. The same is true of junior colleges. where laboratory equipment should meet a different set of government standards specifically established for junior colleges. Closer investigation is called for with regard to those types of equipment which are in short supply in more than 80 percent of colleges and universities. As for the types of equipment in excess supply, investigation should be carried out to determine whether they are really needed in large quantities or should be installed. In many cases, it would appear that unnecessary equipment is procured, even if it is already obsolete, merely for the sake of holding a seemingly impressive armamentarium. 3. Basic Science Laboratory Equipment Among the 39 institutions, five four-year colleges were found to possess equipment for basic science. Only one type of essential equipment, tele-thermometers, and only two types of recommended equipment, rotators and dip chambers, were installed in sufficient numbers to meet the standards. All junior colleges failed to meet the standards in all of equipment categories. Overall, nursing schools at all of the various institutions were found to be below per in terms of laboratory equipment. 4. Required Equipment In response to the question concerning which type of equipment was most needed and not currently in possession, cardiopulmonary resuscitation (CPR) machines and electrocardiogram (ECG) monitors topped the list with four respondents each, followed by measuring equipment. 5. Management of Laboratory Equipment According to the survey, the professors in charge of clinical training and teaching assistants are responsible for management of the laboratory at nursing schools at all colleges and universities, whereas the chief of the general affairs section or chairman of the nursing department manages the laboratory at junior colleges. This suggests that the administrative systems are more or less different. According to the above results, laboratory training could be defined as a process by which nursing students pick up many of the nursing skills necessary to become fully qualified nurses. Laboratory training should therefore be carefully planned to provide students with high levels of hands-on experience so that they can effectively handle problems and emergencies in actual situations. All nursing students should therefore be thoroughly drilled and given as much on-the-job experience as possible. In this regard, there is clearly a need to update the equipment criteria as demanded by society's present situation rather than just filling laboratory equipment quotas according to the current criteria.

  • PDF