• Title/Summary/Keyword: ECG 데이터

Search Result 214, Processing Time 0.031 seconds

The Transmission of Tele-Information System using BlueTooth (블루투스를 이용한 웹으로의 원격 의료정보 전송 시스템)

  • 채희영;강형원;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.05a
    • /
    • pp.130-133
    • /
    • 2002
  • As a society advances, an aging phenomenon and many diseases which did not exist in old times are happening. Especially, in case of the aged patient, because we cant know the time the condition of the patients health become worse, the study of the Tele-information system has been actively carried out by the necessity of a persistent observation. A ECG signal a kind of a vital signals has been widely used to the medical information system as an usual clinical diagnosis for the patients who possess heart diseases. BlueTooth is a close range wireless communication technology which uses a wireless frequency 2.4GHz and has a high trust and self - error correction technology according to a low power consumption quality and a high-speed frequency hopping. This makes get a high trust concerning a data transmission than an existing modem. In addition, though wireless modem is restricted by a minimal of a wireless terminal, It will be possible to coincide with the function of the portable with the low power consumption quality by using Bluetooth. And as the system on a chip of module progresses, the possibility of the small size is present According to this, Bluetooth module transmits the medical information, which is input from the outside among the operations that use the Bluetooth to the Bluetooth module that is connected the host PC. And the system that the host PC transmits the medical information from the connected Bluetooth module to the Internet has once embedded. this study let the host PC embedded in advance of the existing system and transmit the medical information by the addition of the Tcp/Ip protocol stark under all embedded environments to internet.

  • PDF

Design and Implementation of IEEE 11073/HL7 Translation Gateway Based on U-Healthcare Application Service for M2M (M2M을 위한 U-헬스케어 응용 서비스 기반 IEEE 11073/HL7 변환 게이트웨이 설계 및 구현)

  • Chun, Seung-Man;Nah, Jae-Wook;Park, Jong-Tae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.3B
    • /
    • pp.275-286
    • /
    • 2011
  • As the 21st century paradigm of healthcare service changes from post-therapeutic treatment to disease prevention and management in advance, the M2M-based u-healthcare application service is increasingly important. M2M-based u-healthcare application service uses mobile handsets equipped with sensors to measure vital information, and the medical staff in remote locations can manage the health of the patient or the public in real time. In this paper, IEEE/HL7 translation gateway, utilizing the gateway based on M2M u-healthcare application service structure, which is based on international standards, has been designed and implemented. Specifically, the gateway between ISO/IEEE 11073 standards and ANSI HL7 has been developed. The former defines the protocol for the exchange of information between the agent device and the manger devices for measuring and handling biological signal, and the latter defines the application layer protocol for the exchange of various healthcare information systems. Finally, in order to demonstrate the functionality of the proposed architecture, the M2M-based U-healthcare application service based on IEEE/HL7 translation gateway, utilizing the gateway, has been developed which can measure, collect and process a variety of vital signs such as ECG or SpO2.

Development of Bioelectric Signal Sensor System using Band Type ECG (밴드형 심전도 생체신호 전극시스템의 구현)

  • Kang Sung-Chul;Kim Gi-Ryon;Kim Kwang-Nyeon;Jung Dong-Keun;Kim Min-Sung;Jeong Do-Wun;Jeon Gye-Rok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.1023-1026
    • /
    • 2006
  • There are some cases in trouble with monitoring emergency patient by existing electrode sensor in measuring instrument in home and hospital etc. And there are problem to measure because of coming down electrode in emergency car or vessel of shaking and fat, humidity of patient. In this study, it has designed band-type for patient to put on the breast easily and go around anywhere freely putting band electrode on his body. Gold has used as electrode material in this electrocardiogram because of its excellent electronic resistance peculiarity and no trouble with skin. And it is able to monitor multi-body-signal by additional design of periphery temperature. There are good results of body signal transmission in the breast or the rib, and get a little body signal in abdomen. We get a result it is better case of gold than usual electrode on signal detection, and know usual electrode was disposable, but we have more correct result from gold electrode sensor, being semi-permanent ana. great contact ability even if movement.

  • PDF

A Evaluation Parameter Development of Anesthesia Depth in Each Anesthesia Steps by the Wavelet Transform of the Heart Rate Variability Signal (HRV 신호의 웨이브렛 변환에 의한 마취단계별 마취심도 평가 파라미터 개발)

  • Jeon, Gye-Rok;Kim, Myung-Chul;Han, Bong-Hyo;Ye, Soo-Yung;Ro, Jung-Hoon;Baik, Seong-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.9
    • /
    • pp.2460-2470
    • /
    • 2009
  • In this study, the parameter extraction for evaluation of the anesthesia depth in each anesthesia stages was conducted. An object of the this experiment study has studied 5 adult patients (mean $\pm$ SD age:$42{\pm}9.13$), ASA classification I and II, undergoing surgery of obstetrics and gynecology. Anaesthesia was maintained with Enflurane. HRV signal was created by R-peak detection algorithm form ECG signal. The HRV data were preprocessing algorithm. It has tried find out the anesthesia parameter which responds the anesthesia events and shows objective anesthesia depth according to anesthesia stage including pre-anesthesia, induction, maintenance, awake and post-anesthesia. In this study, proposed algorithm to analysis the HRV(heart rate variability) signal using wavelet transform in anesthesia stage. Three sorts of wavelet functions applied to PSD. In the result, all of the results were showed similarly. But experiment results of Daubeches 10 is better. Therefore, this parameter is the best parameter in the evaluation of anesthesia stage.

Development of a Metamodel-Based Healthcare Service System using OSGi Component Platform (OSGi 컴포넌트 플랫폼을 이용한 메타모델 기반의 건강관리 서비스 시스템 개발)

  • Kim, Tae-Woong;Kim, Hee-Cheol
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.1
    • /
    • pp.121-132
    • /
    • 2011
  • A healthcare system is a type of medical information system that performs early detection and prevention in diseases by checking one's health condition periodically. Such a healthcare system is based on the signal obtained from the body. However, the developed existing system represents certain differences in the storage and description of vital signs according to medicare devices and the evaluation method of the system. It brings some disadvantages, such as lacks in the interoperability between systems, increases in the development cost of systems, and absence of a unified system. Thus, this study develops a healthcare system based on a meta model. For establishing this objective, this study describes and stores vital sign data based on the standard meta model of HL7 and applies OCL, which is a mathematical specification language, for defining wellness indexes and extracting data in order to evaluate health risk appraisals in health. In addition, this study implements components based on OSGi and assemble them in order to easily extend various devices and systems. By describing vital data based on the meta model, it represents some advantages that it makes possible to ensure the interoperability between systems and introduce the standardization of the evaluation method of health conditions through defining the wellness index using OCL. Also, it provides dear specifications.

DSP Embeded Hardware for Non-contact Bio-radar Heart and Respiration Rate Monitoring System (DSP를 이용한 비 접촉식 도플러 바이오 레이더 생체신호 모니터링 시스템 임베디드 하드웨어의 개발)

  • Kim, Jin-Seung;Jang, Byung-Jun;Kim, Ki-Doo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.4
    • /
    • pp.97-104
    • /
    • 2010
  • In this paper, we provide an embedded type non-contact bio-radar heart and respiration rate monitoring system. We implemented the rate finding algorithm into the embedded system. The high-speed and reliable real-time signal processor is then tested. To avoid null-point data loss problem, we applied quadrature demodulation. Among several other combining techniques, we suggest arctangent demodulation for quadrature channel combining and DSP is used for real-time signal processing. We also suggest DC-offset compensation technique to preserve the wanted DC components of the IQ signals for accurate demodulation while keeping the dynamic range of the ADC lower. Using Texas Instrument C6711 series DSP and external 12Bit ADC, we implemented proper elliptic digital filter and autocorrelation detection algorithm for robust commercial hand held device.

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

A probabilistic knowledge model for analyzing heart rate variability (심박수변이도 분석을 위한 확률적 지식기반 모형)

  • Son, Chang-Sik;Kang, Won-Seok;Choi, Rock-Hyun;Park, Hyoung-Seob;Han, Seongwook;Kim, Yoon-Nyun
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.3
    • /
    • pp.61-69
    • /
    • 2015
  • This study presents a probabilistic knowledge discovery method to interpret heart rate variability (HRV) based on time and frequency domain indexes, extracted using discrete wavelet transform. The knowledge induction algorithm was composed of two phases: rule generation and rule estimation. Firstly, a rule generation converts numerical attributes to intervals using ROC curve analysis and constructs a reduced ruleset by comparing consistency degree between attribute-value pairs with different decision values. Then, we estimated three measures such as rule support, confidence, and coverage to a probabilistic interpretation for each rule. To show the effectiveness of proposed model, we evaluated the statistical discriminant power of five rules (3 for atrial fibrillation, 1 for normal sinus rhythm, and 1 for both atrial fibrillation and normal sinus rhythm) generated using a data (n=58) collected from 1 channel wireless holter electrocardiogram (ECG), i.e., HeartCall$^{(R)}$, U-Heart Inc. The experimental result showed the performance of approximately 0.93 (93%) in terms of accuracy, sensitivity, specificity, and AUC measures, respectively.

Classification of the PVC Using The Fuzzy-ART Network Based on Wavelet Coefficient (웨이브렛 계수에 근거한 Fuzzy-ART 네트워크를 이용한 PVC 분류)

  • Park, K. L;Lee, K. J.;lee, Y. S.;Yoon, H. R.
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.4
    • /
    • pp.435-442
    • /
    • 1999
  • A fuzzy-ART(adaptive resonance theory) network for the PVC(premature ventricular contraction) classification using wavelet coefficient is designed. This network consists of the feature extraction and learning of the fuzzy-ART network. In the first step, we have detected the QRS from the ECG signal in order to set the threshold range for feature extraction and the detected QRS was divided into several frequency bands by wavelet transformation using Haar wavelet. Among the low-frequency bands, only the 6th coefficient(D6) are selected as the input feature. After that, the fuzzy-ART network for classification of the PVC is learned by using input feature which comprises of binary data converted by applying threshold to D6. The MIT/BIH database including the PVC is used for the evaluation. The designed fuzzy-ART network showed the PVC classification ratio of 96.52%.

  • PDF

Design and Implementation of Electrocardiogram Data Interpretation system using AdaBoost Algorithm (AdaBoost 알고리즘을 이용한 심전도 정보 판독 시스템의 설계 및 구현)

  • Lim, Myung-Jae;Hong, Jin-Kyoung;Kim, Kyu-Ho;Choi, Mi-Lim
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.2
    • /
    • pp.129-134
    • /
    • 2010
  • Diseases such as cardiovascular illnesses, according to the National Statistical Office opened reveals that 600-800 people were killed, blood pressure, arteriosclerosis, heart disease, stroke, etc. will be a flow of blood disorders that occur in cardiovascular illnesses today are fulfilling the Master / Slave samangryulin disease appears high. Died of cardiovascular disease also told them the correct first aid survival when patients are accounted for approximately 40% of emergency rapid response is required. Therefore, this paper, the weak classifier in the AdaBoost algorithm to generate a strong classifier by combining effects throughout the analysis to measure the ECG, and cardiovascular disease that occurred to you as soon as the emergency management system that can deliver on the proposed Desk was. The electrocardiogram data measured by the ZigBee-based sensors, communication devices and emergency transport for emergency alarms in the determination and monitoring of the management desk by providing health services to enable the delivery was fast.