• Title/Summary/Keyword: E.coil

Search Result 311, Processing Time 0.031 seconds

Enhanced Enzyme Activities of Inclusion Bodies of Recombinant ${\beta}$-Galactosidase via the Addition of Inducer Analog after L-Arabinose Induction in the araBAD Promoter System of Escherichia coli

  • Jung, Kyung-Hwan
    • Journal of Microbiology and Biotechnology
    • /
    • v.18 no.3
    • /
    • pp.434-442
    • /
    • 2008
  • We observed that an inclusion body (IB) of recombinant ${\beta}$-galactosidase that was produced by the araBAD promoter system in Escherichia coli (E. coil) showed enzyme activity. In order to improve its activity, the lowering of the transcription rate of the ${\beta}$-galactosidase structural gene was attempted through competition between an inducer (L-arabinose) and an inducer analog (D-fucose). In the deep-well microtiter plate culture and lab-scale fermentor culture, it was demonstrated that the addition of D-fucose caused an improvement in specific ${\beta}$-galactosidase production, although ${\beta}$-galactosidase was produced as an IB. In particular, the addition of D-fucose after induction led to an increase in the specific activity of ${\beta}$-galactosidase IB. Finally, we confirmed that the addition of D-fucose after induction caused changes in the structure of ${\beta}$-galactosidase IB, with higher enzyme activity. Based on these results, we expect that an improved enzyme IB will be used as a biocatalyst of the enzyme bioprocess, because an enzyme IB can be purified easily and has physical durability.

The Clinical Study for Empyema: 176 Cases (농흉의 임상적 고찰[176예])

  • Oh, Bong-Seok;Choi, Jong-Beom;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.475-485
    • /
    • 1980
  • For the past 5 year 6 months from January 1975 to June 1980, 176 patients with empyema have been treated in Chonnam University Hospital. They were 134 males and 42 females ranging from ] 8 days to 69 years of age. [mean age: 26.1 years] The duration of illness prior to treatment was relatively shorter in pediatric group than in adult group, that is, the duration of less than 1 month was 89.5% in pediatric group and 38.0% in adult group. In bacteria study there were Staphylococcus 26.1%, Streptococcus 17.6%, E. coil 10.8%, Pseudomonas 10.8%, Diplococcus pneumoniae 5.7% and Candidia. And 4 children and 3 adults had infections of two species of bacteria. The underlying pathologic lesions were pyogenic pneumonia 34.7%, tuberculosis 29.5%, paragonimiasis 15.3%, trauma 9.7% and postoperative state. The over-all mortality rate was 1.7% [3 patients]. The causes of death were sepsis In 1 child and sepsis secondary to esophageal fistula in 2 adults. Adequate drainage and obliteration of the pleural space seems to be the most important aspect of treatment and can frequently be achieved by initial tube drainage in acute empyema, especially in the pediatric group. The chronic thick walled or loculated cavities required open window therapy, decortication, resection therapy and sterilization. Modified Eloesser`s operation and 0.3-0.5% potadine irrigation brought good result in the patients who had general weakness, marked pulmonary parenchymal destruction due to pyothorax, and pyothorax with severe bronchopleural fistula.

  • PDF

Analysis of Novel Helmholtz-inductively Coupled Plasma Source and Its Application for Nano-Scale MOSFETs

  • Park, Kun-Joo;Kim, Kee-Hyun;Lee, Weon-Mook;Chae, Hee-Yeop;Han, In-Shik;Lee, Hi-Deok
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.2
    • /
    • pp.35-39
    • /
    • 2009
  • A novel Helmholtz coil inductively coupled plasma(H-ICP) etcher is proposed and characterized for deep nano-scale CMOS technology. Various hardware tests are performed while varying key parameters such as distance between the top and bottom coils, the distance between the chamber ceiling and the wafer, and the chamber height in order to determine the optimal design of the chamber and optimal process conditions. The uniformity was significantly improved by applying the optimum conditions. The plasma density obtained with the H-ICP source was about $5{\times}10^{11}/cm^3$, and the electron temperature was about 2-3 eV. The etching selectivity for the poly-silicon gate versus the ultra-thin gate oxide was 482:1 at 10 sccm of $HeO_2$. The proposed H-ICP was successfully applied to form multiple 60-nm poly-silicon gate layers.

Recent Advance in High Pressure Induction Plasma Source

  • Sakuta, T.
    • Journal of Surface Science and Engineering
    • /
    • v.34 no.5
    • /
    • pp.395-402
    • /
    • 2001
  • An induction thermal plasma system have been newly designed for advanced operation with a pulse modulated mode to control the plasma power in time domain and to create non-equilibrium effects such as fast quenching of the plasma to produce new functional materials in high rate. The system consists of MOSFET power supply with a maximum power of 50 kW with a frequency of 460 kHz, an induction plasma torch with a 10-turns coil of 80 mm diameter and 150 mm length and a vacuum chamber. The pulse modulated plasma was successfully generated at a plasma power of 30 kW and a high pressure of 100 kPa, with taking the on and off time as 10 ms, respectively. Measurements were carried out on the time-dependent spectral lines emitted from Ar species. The dynamic behavior of plasma temperature in a pulse cycle was estimated by the Boltzmann plot and the excitation temperature of Ar atom was found to be changed periodically from around 0.5 to 1.7 eV during the cycle. Two application regions of the induction thermal plasma newly generated were introduced to material processing with high rate synthesis based on non equilibrium effects, and to the finding of new arc quenching gases coming necessary for power circuit breaker, which is friendly with earth circumstance alternative to SF6 gas.

  • PDF

Estimation Method for Kinematic Constraint of Unknown Object by Active Sensing (미지 물체의 구속상태에 관한 실시간 추정방법)

  • Hwang Chang-Soon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.2 s.233
    • /
    • pp.188-200
    • /
    • 2005
  • Control of a multi-fingered robotic hand is usually based on the theoretical analysis for kinematics and dynamics of fingers and of object. However, the implementation of such analyses to robotic hands is difficult because of errors and uncertainties in the real situations. This article presents the control method for estimating the kinematic constraint of an unknown object by active sensing. The experimental system has a two-fingered robotic hand suspended vertically for manipulation in the vertical plane. The fingers with three degrees-of-freedom are driven by wires directly connected to voice-coil motors without reduction gears. The fingers are equipped with three-axis force sensors and with dynamic tactile sensors that detect slippage between the fingertip surfaces and the object. In order to make an accurate estimation for the kinematic constraint of the unknown object, i.e. the constraint direction and the constraint center, four kinds of the active sensing and feedback control algorithm were developed: two position-based algorithms and two force-based algorithms. Furthermore, the compound and effective algorithm was also developed by combining two algorithms. Force sensors are mainly used to adapt errors and uncertainties encountered during the constraint estimation. Several experimental results involving the motion of lifting a finger off an unknown object are presented.

Molecular characterization and functional analysis of a protease-related protein in Chang-liver cells

  • Wang, Congrui;Zhang, Huiyong;Feng, Huigen;Yang, Baosheng;Pramanik, Jogenananda;Guo, Zhikun;Lin, Juntang
    • BMB Reports
    • /
    • v.43 no.5
    • /
    • pp.375-381
    • /
    • 2010
  • In this study, the cDNA library of Chang-liver cells was immunoscreened using common ADAMs antibody to obtain ADAM related genes. We found one positive clone that was confirmed as a new gene by Blast, which is an uncharacterized helical and coil protein and processes protease activity, and named protease-related protein 1 (ARP1). The submitted GenBank accession number is AY078070. Molecular characterizations of ARP1 were analyzed with appropriate bioinformatics software. To analyse its expression and function, ARP1 was subcloned into glutathione S-transferase fusion plasmid pGEX-2T and expressed by E. coli system. The in vitro expression product of ARP1 was recognized by common ADAMs antibody with western blot. Interestingly, ARP1 cleaves gelatine at pH9.5, which suggests it is an alkaline protease. Semi-quantitative RT-PCR result indicates that ARP1 mRNA is strongly transcribed in the liver and the treated Chang-liver cells.

Growth-Inhibiting Effects of Various Traditional Drinks of Plant Origin on Human Intestinal Bacteria

  • Jeon, Ho-Joung;Roh, Jung-Yeon;Kim, Do-Hyoung;Lee, Wan-Kyu;Ahn, Young-Joon
    • Applied Biological Chemistry
    • /
    • v.41 no.8
    • /
    • pp.605-607
    • /
    • 1998
  • A total of 28 traditional drinks derived from 23 plant species in 19 families were tested for their in vitro growth-inhibiting effects against Bifidobacterium adolescents, Bifidobacterium bifidum, Lactobacillus acidophilus, Lactobacillus casei, Clostridium perfringens, and Escherichia coil using a paper disc agar diffusion method under anaerobic condition. The responses varied with bacterial strain, plant species and tissue sampled. In a test with C. perfringens at 5 and 10 mg/disc, potent growth inhibition was produced from the extracts of Eucommia ulmoides stems, Pinus densiflora leaves and shoots, Thea sinensis leaves (green and oolong teas) and Zingiber officinale roots. All materials tested did not adversely affect the growth of bifidobacteria, lactobacilli, and E. coli. These results may be an indication of at least one of the pharmacological activities of these plant-derived drinks.

  • PDF

Prevalence and Characterization of Enterohemorrhagic Escherichia coli (EHEC) Isolated from Ground Beefs Distributed in Gyeong-In Region (경인지역에 유통되는 분쇄육 중 장출혈성대장균의 분포 조사 및 특성 연구)

  • Kim, Eun-Jeong;Park, Yong-Chjun;Cho, Joon-Il;Lee, Jong-Ok;Kim, Hee-Yun
    • Korean Journal of Food Science and Technology
    • /
    • v.38 no.6
    • /
    • pp.773-778
    • /
    • 2006
  • The objective of this study was to evaluate three verocytotoxin-producing Escherichia coli (VTEC) detection kits to detect the presence of VT genes: Doupath Verocytotoxin (GLISA) developed by MERCK, ProsPect Shiga Toxin E. coil (STEC) Microplate Assay (ELISA) developed by Remel, and a polymerase chain reaction method. Our laboratory verified artificially inoculated samples. All three methods could detect very low numbers of VTEC, but VT-PCR had the best sensitivity for VTEC detection. From April through September 2005, 257 ground-beefs from supermakets and traditional markets were examined for the presence of VTEC by polymerase chain reaction immediately after purchase and total viable counts (TVC) were determined. VTEC was isolated from 30 of 257 ground-beefs. A variety of serogroups was found, including 10 stains belonging to the virulence type EHEC, but major serogroups such as O157, O26 and O111 were nor found.

Development of In-Process Polishing Pressure Control System (실시간 폴리싱 압력 제어시스템 개발)

  • 오창진;전문식;김옥현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.1
    • /
    • pp.109-115
    • /
    • 2004
  • Polishing process has been applied to get extremely fine surfaces, e.g., mirror surfaces such as optical mirrors, lens, molds and etc. Nowadays not only fine surface quality but also submicron order of dimensional accuracy is required for many applications. To meet the requirements polishing process should be provided with an active control of polishing pressure especially for automation of polishing process. In this paper a study on development of an active polishing pressure control system has been presented. A new type of tool assembly has been developed to facilitate the control. The tool is attached to an axis of a polishing machine with a coil spring and control of the polishing pressure is done by the position control of the axis, which needs no additional actuator. The polishing pressure is successfully measured by the measurement of the spring deformation. Control specifications were quantitatively considered by weighting functions and a controller was designed by using loop-shaping technique based on the no synthesis. Some experiments have been executed on a polishing machine with a PC-NC controller. It is shown that the results were coincident well with the theoretical analyses and satisfied the design specifications.

Seismic protection of base isolated structures using smart passive control system

  • Jung, Hyung-Jo;Choi, Kang-Min;Park, Kyu-Sik;Cho, Sang-Won
    • Smart Structures and Systems
    • /
    • v.3 no.3
    • /
    • pp.385-403
    • /
    • 2007
  • The effectiveness of the newly developed smart passive control system employing a magnetorheological (MR) damper and an electromagnetic induction (EMI) part for seismic protection of base isolated structures is numerically investigated. An EMI part in the system consists of a permanent magnet and a coil, which changes the kinetic energy of the deformation of an MR damper into the electric energy (i.e. the induced current) according to the Faraday's law of electromagnetic induction. In the smart passive control system, the damping characteristics of an MR damper are varied with the current input generated from an EMI part. Hence, it does not need any control system consisting of sensors, a controller and an external power source. This makes the system much simpler as well as more economic. To verify the efficacy of the smart passive control system, a series of numerical simulations are carried out by considering the benchmark base isolated structure control problems. The numerical simulation results show that the smart passive control system has the comparable control performance to the conventional MR damper-based semiactive control system. Therefore, the smart passive control system could be considered as one of the promising control devices for seismic protection of seismically excited base isolated structures.