• Title/Summary/Keyword: E. coil

Search Result 310, Processing Time 0.027 seconds

Structure of Ti and Al Films Prepared by Cylindrical Sputtering System (원통형 스퍼터링 장치로 제작한 Ti 및 Al 박막구조)

  • Oh, Chang-Sup;Han, Chang-Suk
    • Korean Journal of Materials Research
    • /
    • v.24 no.7
    • /
    • pp.344-350
    • /
    • 2014
  • Metal films (i.e., Ti, Al and SUH310S) were prepared in a magnetron sputtering apparatus, and their cross-sectional structures were investigated using scanning electron microscopy. The apparatus used consisted of a cylindrical metal target which was electrically grounded, and two anode rings attached to the top and to the bottom of the target. A wire was placed along the center-line of the cylindrical target to provide a substrate. When the electrical potential of the substrate was varied, the metal-film formation rate depended on both the discharge voltage and the electrical potential of the substrate. As we made the magnetic field stronger, the plasma which appeared near the target collected on the plasma wall surface and thereby decreased the bias current. The bias current on the conducting wire was different from that for cation collection. The bias current decreased because the collection of cations decreased when we increased the magnetic-coil current. When the substrate was electrically isolated, the films deposited showed a slightly coarse columnar structure with thin voids between adjacent columns. In contrast, in the case of the grounded substrate, the deposited film did not show any clear columns but instead, showed a densely-packed granular structure. No peeling region was observed between the film and substrate, indicating good adhesion.

Draft genome sequences of Enterococcus faecium JB00008 (KACC 92186P) isolated from Korean fermented soybean paste (Cheonggukjang) (한국 전통유래식품(청국장)에서 분리한 Enterococcus faecium JB00008 (KACC 92186P) 유산균주의 유전체 분석)

  • Park, Jongbin;Jin, Gwi-Deuk;Kim, Eun Bae
    • Korean Journal of Microbiology
    • /
    • v.54 no.2
    • /
    • pp.171-173
    • /
    • 2018
  • Enterococcus faecium was commonly used as a probiotics and feed additives to human and animals because of their beneficial effects. We sequenced the genome of E. faecium JB00008 (KACC 92186P) isolated from a Korean fermented soybean paste (Cheonggukjang) that showed antibacterial activity against Escherichia coli. A 2,847,295-bp draft genome was obtained, and it has in 37.84% G + C content in 34 contigs (length, ${\geq}500bp$).

Design Considerations of 1MW Class HTS Synchronous Motor (1MW급 고온초전도 동기 모터 설계 고찰)

  • Baik S.K.;Sohn M.H.;Lee E.Y.;Kwon Y.K.;Moon T.S.;Kim Y.C.;Cho C.H.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.809-811
    • /
    • 2004
  • A 1MW class superconductng synchronous motor is designed considering several conditions such as superconducting wire length, machine efficiency and size. As the machine is larger and larger, the superconducting machine shows the advantages more and more over the conventional machines. Although the advantages at 1MW rating are not so great, the design approach to get an appropriate result would be very helpful for larger superconducting synchronous machine design. Major design concerns are focused on reducing expensive Bi-2223 HTS(High Temperature Superconducting) wire which is used for superconducting field coil carrying the rating current around 30K($-243^{\circ}C$) while the machine efficiency is higher than conventional motors or generators with the same rating. Furthermore, some iron cored structure is considered to reduce the HTS wire requirement without bad effect on machine performances such as sinusoidal armature voltage waveform, synchronous reactance and so on.

  • PDF

Design of Current PI Controller for 2-Axis Linear Actuator (2축 선형 엑츄에이터의 전류 PI제어기 설계)

  • Zun, Chan-Young;Kim, Jae-Han;Mok, Hyung-Soo;Choe, Gyu-Ha;Lee, Jung-Min;Kim, Sang-Hoon;Kim, Tae-Hoon
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.321-324
    • /
    • 2007
  • The actuators of anti-vibration system(AVS) can be separated into several types: piezoelectric actuators, pneumatic springs, cylinders, rotating motor and linear motor. The last one has some advantages, such as low noise, low vibration, simpler configuration and possibility of direct drive. The voice coil motor(VCM) is one type of linear motor, originally used in speaker system. VCM actuators are usually used in occasions that rapid and controlled motion of devices are required. In this paper, a controller which satisfies system specification(e.g. current controller bandwidth) within whole operation range is designed. For that objective, parameters as position were initially obtained with 3D FEM analysis and motor modeling was performed. A current controller in 2-axis VCM drive system was designed and then performance of the proposed controller was verified with simulation using Simplorer and an experimental result.

  • PDF

A Study on Influences of the Antibacterial Activity of Methampicillin Lysinate by the Several Medicinals (병용약물(倂用藥物)이 Methampicillin Lysinate의 항균력(抗菌力)에 미치는 영향(影響))

  • Kim, Seung-Up;Kim, Young-Il;Kim, Johng-Kap
    • Journal of Pharmaceutical Investigation
    • /
    • v.8 no.1
    • /
    • pp.1-5
    • /
    • 1978
  • Drug interaction of a new antibiotic, methampicillin lysinate (MAL) with nine drugs were investigated using four species of gram positive and gram negative bacteria. The experimental results were as follows: 1. MIC of MAL were found to be decreased against E. coil when combined with mefenamic acid, probenecid, aluminium hydroxide gel or corticosteroids. The other drugs did not affect MIC of MAL against the same bacteria. 2. MIC of MAL were found to be increased against Staphylococcus aureus ATCC 6538-P, 9441 when combined with mefenamic acid, aluminum hydroxide gel or dexamethasone acetate. The other drugs did not affect MIC of MAL against the same bacteria. 3. MIC of MAL were found to be increased against Shigella dysenteriae when either of the nine drugs was combined. 4. MIC of MAL were found to be increased approximately 2.5 times when combined with Streptokinase-Streptodornase or hydrocortisone and to be decreased approximately 2 times when combined with probenecid or dexamethasone against Salmonella typhi(type 2). It seems the other drugs do not affect the MIC of MAL against the same bacteria.

  • PDF

Soil Water Diffusivity and Soil Water Stress Coefficient Studies Using Weighting Lysimeter Data (토양수분확산계수 측정과 자동측정리이시메타를 이용한 토양수분계수 추정)

  • Oh, Dong-Shig;Ayars, James E.;Soppe, Richard;Eom, Ki-Cheol
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.32 no.4
    • /
    • pp.344-356
    • /
    • 1999
  • A new and relatively simple equation for the soil water content-pressure head curve, ${\theta}$(h) is described in this paper. The particular form of the equation enables one to derive closed-form analytical expressions for the relative hydraulic conductivity, Kr, when substituted in the predictive conductivity models of Y. Mualem. Hopmans' equation is presented as an experimental method. The experienced method, $ET_a=K_sK_cET_o$ is introduced to estimate the actual evapotranspiration, $ET_a$(or $ET_c$). Using $ET_c$ and coil water data measured automatically in a weighing lusimeter, $K_s$ and $K_c$ values are estimated. Recently, FAO has introduced calculation procedures for the soil water(stress) coefficient, Ks in "Guidelines for computing crop water requirements".

  • PDF

Accelerating Magnetic Resonance Fingerprinting Using Hybrid Deep Learning and Iterative Reconstruction

  • Cao, Peng;Cui, Di;Ming, Yanzhen;Vardhanabhuti, Varut;Lee, Elaine;Hui, Edward
    • Investigative Magnetic Resonance Imaging
    • /
    • v.25 no.4
    • /
    • pp.293-299
    • /
    • 2021
  • Purpose: To accelerate magnetic resonance fingerprinting (MRF) by developing a flexible deep learning reconstruction method. Materials and Methods: Synthetic data were used to train a deep learning model. The trained model was then applied to MRF for different organs and diseases. Iterative reconstruction was performed outside the deep learning model, allowing a changeable encoding matrix, i.e., with flexibility of choice for image resolution, radiofrequency coil, k-space trajectory, and undersampling mask. In vivo experiments were performed on normal brain and prostate cancer volunteers to demonstrate the model performance and generalizability. Results: In 400-dynamics brain MRF, direct nonuniform Fourier transform caused a slight increase of random fluctuations on the T2 map. These fluctuations were reduced with the proposed method. In prostate MRF, the proposed method suppressed fluctuations on both T1 and T2 maps. Conclusion: The deep learning and iterative MRF reconstruction method described in this study was flexible with different acquisition settings such as radiofrequency coils. It is generalizable for different in vivo applications.

Analysis of Electromagnetic Characteristics of a 1MW Class HTS Synchronous Motor (1MW급 고온초전도 동기기의 전자기적 특성 해석)

  • Baik, S.K.;Kwon, Y.K.;Lee, E.Y.;Lee, J.D.;Kim, Y.C.;Moon, T.S.;Park, H.J.;Kwon, W.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.32-36
    • /
    • 2007
  • On the contrary of a conventional motor with very narrow air-gap. it is difficult to calculate the accurate magnetic field distribution and the performance of an air-cored superconducting motor by 2 dimensional analysis. which does not use high permeability material except outer machine shield. This paper aims to do analysis of magnetic field and force distribution from the 3 dimensional modelling of a 1MW class superconducting synchronous motor. Especially. the field coil composed of Bi-2223 high-temperature superconductor and the outer machine shield are modelled by finite element analysis software according to their structures and the self-inductance and Lorentz force are calculated based on the 3 dimensional magnetic field calculation. Moreover. the influence of an important parameter, synchronous reactance, has been analyzed on the machine performances such as voltage variation and output power.

Operation result of the Cryogenic and Mechanical Measurement System for KSTAR (KSTAR 저온 및 구조 계측 시스템 운전 결과)

  • Kim, Y.O.;Chu, Y.;Yonekawa, H.;Bang, E.N.;Lee, T.G.;Baek, S.H.;Hong, J.S.;Lee, S.I.;Park, K.R.;Oh, Y.K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.3
    • /
    • pp.26-30
    • /
    • 2009
  • Korea Superconducting Tokamak Advanced Research(KSTAR) device is composed of 30 superconducting magnets, magnet structure, vacuum vessel, cryostat, current feeder system, and etc. KSTAR device is operated in the cryogenic temperature and high magnetic field. We install about 800 sensors - temperature sensors, stain gages, displacement gages, hall sensors - to monitor the thermal, mechanical, electrical status of KSTAR during operation. As a tremendous numbers of sensors should be installed for monitoring the KSTAR device, the method of effective installation was developed. The sensor test was successfully carried out to check its reliability and its reproduction in the cryogenic temperature. The sensor signal is processed by PXI-based DAQ system and communicated with central control system via machine network and is shown by Operator Interface(OPI) display in the main control room. In order to safely operate the device, any violations of mechanical & superconductive characteristic of the device components were informed to its operation system & operator. If the monitored values exceed the pre-set values, the protective action should be taken against the possible damage. In this paper, the system composition, operation criteria, operation result were presented.

Iatrogenic mixed pial and dural arteriovenous fistula after pterional approach for surgical clipping of aneurysm: A case report

  • Seung-Bin Woo;Young San Ko;Chang-Young Lee
    • Journal of Cerebrovascular and Endovascular Neurosurgery
    • /
    • v.25 no.4
    • /
    • pp.440-446
    • /
    • 2023
  • Craniotomy is known as a cause of iatrogenic dural cerebral arteriovenous fistula (AVF). However, mixed pial and dural AVFs after craniotomy are extremely rare and require accurate diagnosis and prompt treatment due to their aggressiveness. We present a case of an iatrogenic mixed pial and dural AVF diagnosed 2 years after pterional craniotomy for surgical clipping of a ruptured anterior choroidal aneurysm. The lesion was successfully treated using single endovascular procedure of transvenous coil embolization through the engorged vein of Labbe and the superficial middle cerebral vein. The possibility of the AVF formation after the pterional approach should always be kept in mind because it usually occurs at the middle cranial fossa, which frequently has an aggressive nature owing to direct cortical venous or leptomeningeal drainage patterns. This complication is believed to be caused by angiogenetic conditions due to coagulation, retraction, and microinjuries of the perisylvian vessels, and can be prevented by performing careful sylvian dissection according to patient-specific perisylvian venous anatomy.