• Title/Summary/Keyword: E-Field sensor

검색결과 155건 처리시간 0.025초

붐방제기의 곡선행로 조향반경에 따른 붐의 구간별 유량제어 (Sectional Flow-rate Control of Boom Sprayer According to the Steering Radius along Winding Rows)

  • 김은수;김영주;이중용
    • Journal of Biosystems Engineering
    • /
    • 제31권3호
    • /
    • pp.146-152
    • /
    • 2006
  • Most upland in Korea have irregular field shapes. Boom sprayers working alone winding row will show considerable differences of spraying amount per unit area between left and right booms. If flow rates of both booms are equal. This phenomenon becomes significant as steering radius of sprayer decreases. This study was performed to seek a method which reduce the difference of the spray amount between left, right and center booms while spraying along curvy rows. A flow rate control method for keeping application rate of each boom section constant was proposed and experimentally proved using a boom sprayer attached to a cultivating tractor. The flow rate control device was composed of 3 ball valves and a rotary angle sensor. The rotary angle sensor showed a symmetric voltage output with respect to steering radius. The spray overlapping was happened in a boom nearby the steering center when steering radius of the sprayer was less than 5.2 m. Flow rates for left, right and center booms were regulated using ball valves based on the steering radius and spraying areas ration of right/left boom. The Maximum spraying area ratio ($S_{LR}$) of left to right boom section was 1:3.6 at the steering radius of 5.2 m. However, The Maximum achieved right and left spraying flow ratio was 1:2.7.

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

사면붕괴 모니터링에 사용되는 온도-함수비 복합계측시스템 개발에 관한 실험적 연구 (Experimental Study on Temperature-Moisture Combined Measurement System for Slope Failure Monitoring)

  • 남진원
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권2호
    • /
    • pp.33-39
    • /
    • 2015
  • 최근 급속한 기후변화 및 광범위한 사회간접시설의 개발 등으로 인해 사면붕괴가 곳곳에서 발생하고 있으며, 이에 대한 모니터링 및 예방시스템 구축에 대한 사회적인 관심이 증가하고 있는 상태이다. 사면붕괴 메카니즘에 영향을 미치는 중요한 영향인자는 지표내 수분 및 온도이며 이에 대한 변화 추이를 통해 사면붕괴를 예측할 수 있다. 따라서, 사면붕괴 모니터링을 위해서는 지표 깊이별 온도 및 함수비를 연속적으로 측정할 수 있는 복합센싱 기법이 필요하다고 볼 수 있다. 현재까지 온도 및 함수비에 대해 각각의 계측이 가능한 개별 센서는 다양하게 개발되어 있는 상태이지만, 온도 및 함수비를 동시에 연속적으로 측정할 수 있는 복합계측 시스템의 경우에는 많은 연구가 필요한 상태이다. 본 논문에서는 전류소모가 최소화된 측온 회로와 고주파 신호를 토양에 방사하는 수분 측정 센서를 적용한 고정밀 온도-함수비 복합센서를 개발하여 효율적이고 정확도를 향상시킨 사면붕괴 모니터링 시스템에 적용할 수 있도록 하였다. 개발된 복한센서의 성능검증을 위하여 기본성능 표준시험, 실내검증실험, 현장장기실험 등의 다양항 실험적 연구를 수행하였으며, 실험결과를 통해 개발된 복합센서를 이용한 모니터링 시스템은 지반의 온도 및 함수비를 정확하게 모니터링할 수 있는 것으로 나타났다.

Electrocaloric Effect in Pb0.865La0.09(Zr0.65Ti0.35)O3 Thin Film

  • Roh, Im-Jun;Kwon, Beomjin;Moon, Hi Gyu;Kim, Jin-Sang;Kang, Chong-Yun
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.224-228
    • /
    • 2014
  • The electrocaloric effect of 9/65/35 PLZT thin film fabricated by the sol-gel method, which has not been studied yet, was investigated for its structural, electrical properties as well as temperature change property. The relaxor ferroelectric property of 9/65/35 PLZT thin film was confirmed by examining its dielectric and electrical properties. The relaxor property can cause a more pronounced electrocaloric effect (ECE) in a wider temperature range than normal ferroelectric film. To avoid errors caused by using an indirect measurement method, the leakage current generated by increasing temperatures was minimized by using the optimal maximum electric field ($350kVcm^{-1}$) in the thin film. The largest temperature change ${\delta}T$ (0.23 K) and the electrocaloric strength ${\xi}$ (0.68 mkcm/kV), calculated by equations were obtained. The maximum field change ${\delta}E$ ($191kVcm^{-1}$) was in the vicinity of the curie temperature ($200^{\circ}C$).

FeCoSiB계 아몰퍼스 자성박막의 자기-임피 던스 효과 (Magneto-Impedance Effect of FeCoSiB Amorphous Magnetic Films)

  • 신용진;소대화;김현욱;김대주;서강수
    • 한국재료학회지
    • /
    • 제8권3호
    • /
    • pp.252-255
    • /
    • 1998
  • 본논문은 FeCoCiB계 아몰퍼스 자성박막의 주파수에 따른 자기 임피던스(MI)효과에 관하여 조사한 것이다. 영자왜를 갖는 아몰퍼스 자성박막은 고주파 스파터링법에 의하여 제작하였으며, 자계중 열처리를 행하였다. 제작된 자성박막에 직접 외부자계를 인가했을 때, 자성박막의 양단간의 전압진폭은 120[MHz]에서 약 76.2%의 변화를 보였으며, 임피던스는 2.1%/Oe의 변화가 나타났다. 따라서, 제작한 자성박막은 센서소자로서의 가능성을 갖고 있음을 확인하였다.

  • PDF

실내 주광조도 분포 예측식의 제안 및 검증 (Proposal of the Prediction Equation for Interior Daylight Illuminance)

  • 박웅규;박태주;강규민;이상엽;송두삼
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.114-123
    • /
    • 2013
  • In these days, most of the office buildings are being required to save energy for maintenance. lighting system constitutes 20% to 30% of the total annual electrical energy consumption in office buildings. As an energy saving strategy for lighting system, dimming control system based on illuminance sensors came into use. But the system is accompanied with many illuminance sensors to control lighting and needs a lot of initial investment. In this study, the prediction equation for indoor daylighting illuminance distribution is proposed through the review for conventional research results and field measurements. The proposed equation was verified by the comparison between predicted results and field measurement results. The developed prediction equation for daylighting can be used to control the indoor illuminance level with the limited sensor when dimming control system is operated.

Using machine learning for anomaly detection on a system-on-chip under gamma radiation

  • Eduardo Weber Wachter ;Server Kasap ;Sefki Kolozali ;Xiaojun Zhai ;Shoaib Ehsan;Klaus D. McDonald-Maier
    • Nuclear Engineering and Technology
    • /
    • 제54권11호
    • /
    • pp.3985-3995
    • /
    • 2022
  • The emergence of new nanoscale technologies has imposed significant challenges to designing reliable electronic systems in radiation environments. A few types of radiation like Total Ionizing Dose (TID) can cause permanent damages on such nanoscale electronic devices, and current state-of-the-art technologies to tackle TID make use of expensive radiation-hardened devices. This paper focuses on a novel and different approach: using machine learning algorithms on consumer electronic level Field Programmable Gate Arrays (FPGAs) to tackle TID effects and monitor them to replace before they stop working. This condition has a research challenge to anticipate when the board results in a total failure due to TID effects. We observed internal measurements of FPGA boards under gamma radiation and used three different anomaly detection machine learning (ML) algorithms to detect anomalies in the sensor measurements in a gamma-radiated environment. The statistical results show a highly significant relationship between the gamma radiation exposure levels and the board measurements. Moreover, our anomaly detection results have shown that a One-Class SVM with Radial Basis Function Kernel has an average recall score of 0.95. Also, all anomalies can be detected before the boards are entirely inoperative, i.e. voltages drop to zero and confirmed with a sanity check.

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

Effect of Proton Irradiation on the Magnetic Properties of Antiferromagnet/ferromagnet Structures

  • Kim, Dong-Jun;Park, Jin-Seok;Ryu, Ho Jin;Jeong, Jong-Ryul;Chung, Chang-Kyu;Park, Byong-Guk
    • Journal of Magnetics
    • /
    • 제21권2호
    • /
    • pp.159-163
    • /
    • 2016
  • Antiferromagnet (AFM)/ferromagnet (FM) bilayer structures are widely used in the magnetic devices of sensor and memory applications, as AFM materials can induce unidirectional anisotropy of the FM material via exchange coupling. The strength of the exchange coupling is known to be sensitive to quality of the interface of the AFM/FM bilayers. In this study, we utilize proton irradiation to modify the interface structures and investigate its effect on the magnetic properties of AFM/FM structures, including the exchange bias and magnetic thermoelectric effect. The magnetic properties of IrMn/CoFeB structures with various IrMn thicknesses are characterized after they are exposed to a proton beam of 3 MeV and $1{\sim}5{\times}10^{14}ions/cm^2$. We observe that the magnetic moment is gradually reduced as the amount of the dose is increased. On the other hand, the exchange bias field and thermoelectric voltage are not significantly affected by proton irradiation. This indicates that proton irradiation has more of an influence on the bulk property of the FM CoFeB layer and less of an effect on the IrMn/CoFeB interface.

열교환설비에서의 파울링 진단기술에 관한 연구 (A Study on the Diagnostic Technology for Fouling Occurred in Heat Exchanger)

  • 정경열;류길수;이후락
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권5호
    • /
    • pp.502-508
    • /
    • 2005
  • Fouling causes serious maintenance problems on heat exchanger tubes and process facilities. To avoid such fouling problems, numerous efforts have been tried. e.g., diagnosis of fouling, reducing and eliminating the fouling. etc.. The objective of the present study is to develop an innovative diagnostic system of fouling, which can detect the scaling attached to the wall non-homogeneously. The performance of the diagnostic system has been evaluated with a scaling simulator that generates scaling on tested tube wall. The measured values with the diagnostic system were compared with the amounts of the scaling generated by the simulator. In addition to, we showed the data that have been executed in field test for reliability verification.