• 제목/요약/키워드: Dynamic matrix

검색결과 1,218건 처리시간 0.03초

Improvement of the Reliability Graph with General Gates to Analyze the Reliability of Dynamic Systems That Have Various Operation Modes

  • Shin, Seung Ki;No, Young Gyu;Seong, Poong Hyun
    • Nuclear Engineering and Technology
    • /
    • 제48권2호
    • /
    • pp.386-403
    • /
    • 2016
  • The safety of nuclear power plants is analyzed by a probabilistic risk assessment, and the fault tree analysis is the most widely used method for a risk assessment with the event tree analysis. One of the well-known disadvantages of the fault tree is that drawing a fault tree for a complex system is a very cumbersome task. Thus, several graphical modeling methods have been proposed for the convenient and intuitive modeling of complex systems. In this paper, the reliability graph with general gates (RGGG) method, one of the intuitive graphical modeling methods based on Bayesian networks, is improved for the reliability analyses of dynamic systems that have various operation modes with time. A reliability matrix is proposed and it is explained how to utilize the reliability matrix in the RGGG for various cases of operation mode changes. The proposed RGGG with a reliability matrix provides a convenient and intuitive modeling of various operation modes of complex systems, and can also be utilized with dynamic nodes that analyze the failure sequences of subcomponents. The combinatorial use of a reliability matrix with dynamic nodes is illustrated through an application to a shutdown cooling system in a nuclear power plant.

A HYBRID SCHEME USING LU DECOMPOSITION AND PROJECTION MATRIX FOR DYNAMIC ANALYSIS OF CONSTRAINED MULTIBODY SYSTEMS

  • Yoo, W.S.;Kim, S.H.;Kim, O.J.
    • International Journal of Automotive Technology
    • /
    • 제2권3호
    • /
    • pp.117-122
    • /
    • 2001
  • For a dynamic analysis of a constrained multibody system, it is necessary to have a routine for satisfying kinematic constraints. LU decomposition scheme, which is used to divide coordinates into dependent and independent coordinates, is efficient but has great difficulty near the singular configuration. Other method such as the projection matrix, which is more stable near a singular configuration, takes longer simulation time due to the large amount of calculation for decomposition. In this paper, the row space and the null space of the Jacobian matrix are proposed by using the pseudo-inverse method and the projection matrix. The equations of the motion of a system are replaced with independent acceleration components using the null space of the Jacobian matrix. Also a new hybrid method is proposed, combining the LU decomposition and the projection matrix. The proposed hybrid method has following advantages. (1) The simulation efficiency is preserved by the LU method during the simulation. (2) The accuracy of the solution is also achieved by the projection method near the singular configuration.

  • PDF

단어 구름과 동적 그래픽스 기법을 이용한 영어성경 텍스트 시각화 (English Bible Text Visualization Using Word Clouds and Dynamic Graphics Technology)

  • 장대흥
    • 응용통계연구
    • /
    • 제27권3호
    • /
    • pp.373-386
    • /
    • 2014
  • 단어 구름은 문자 텍스트 상의 복수개의 단어들을 대상으로 그 단어들의 출현 빈도에 비례하는 글자의 크기나 글자의 색깔로 중요도를 나타내는 텍스트 시각화 방법이다. 이 그림은 텍스트 상의 핵심단어를 재빨리 인지하고 단어들의 상대적 출현빈도수에 맞추어 배열하는 데 유용하다. 동적 그래픽스를 이용하여 텍스트 장들의 변화에 따른 핵심단어와 단어출현빈도의 패턴의 변하는 모습을 살필 수 있다. 행들이 텍스트 상의 장들이고 열들이 텍스트에 출현하는 단어들의 출현빈도수 순위들인 단어출현빈도행렬을 정의할 수 있고 이 행렬을 이용하여 단어출현빈도행렬그림을 그릴 수 있다. 동적 그래픽스를 이용하여 출현빈도수 순위의 변화에 따른 단어출현빈도행렬의 패턴의 변하는 모습을 살필 수 있다. 우리는 단어 구름과 동적 그래픽스 기법을 사용하여 영어성경 텍스트 시각화를 수행할 수 있다.

Geometrically non-linear dynamic analysis of plates by an improved finite element-transfer matrix method on a microcomputer

  • Chen, YuHua
    • Structural Engineering and Mechanics
    • /
    • 제2권4호
    • /
    • pp.395-402
    • /
    • 1994
  • An improved finite element-transfer matrix method is applied to the transient analysis of plates with large displacement under various excitations. In the present method, the transfer of state vectors from left to right in a combined finite element-transfer matrix method is changed into the transfer of generally incremental stiffness equations of every section from left to right. Furthermore, in this method, the propagation of round-off errors occurring in recursive multiplications of transfer and point matrices is avoided. The Newmark-${\beta}$ method is employed for time integration and the modified Newton-Raphson method for equilibrium iteration in each time step. An ITNONDL-W program based on this method using the IBM-PC/AT microcomputer is developed. Finally numerical examples are presented to demonstrate the accuracy as well as the potential of the proposed method for dynamic large deflection analysis of plates with random boundaries under various excitations.

유한요소-전달행렬의 혼합물을 이용한 3차원 구조물의 진동해석 (Vibration Analysis of 3-Dimensional Structure by using Mixed Method of Finite Element-Transfer Matrix)

  • 이동명
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.16-22
    • /
    • 2001
  • In this study for reduction degree of freedom of dynamic model, a mixed method to combined finite element method and transfer matrix method is presented. This offers the advantages of an automatic reduction in the size of the eigenvalues problem and of a straightforward means of dynamic substructuring. The analytical procedure in this method for dynamic analysis of 3-dimensional cantilevered box beam are described. the result of numerical example is shown to demonstate the efficiency and accuracy of this method. The result form this example agree well those obtained by ANSYS, By using this technique, the number of nodes required in the regular finite element method is reduced and therefore a smaller com-puter can be used.

  • PDF

Temperature Control of Ultrasupercritical Once-through Boiler-turbine System Using Multi-input Multi-output Dynamic Matrix Control

  • Moon, Un-Chul;Kim, Woo-Hun
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.423-430
    • /
    • 2011
  • Multi-input multi-output (MIMO) dynamic matrix control (DMC) technique is applied to control steam temperatures in a large-scale ultrasupercritical once-through boiler-turbine system. Specifically, four output variables (i.e., outlet temperatures of platen superheater, finish superheater, primary reheater, and finish reheater) are controlled using four input variables (i.e., two spray valves, bypass valve, and damper). The step-response matrix for the MIMO DMC is constructed using the four input and the four output variables. Online optimization is performed for the MIMO DMC using the model predictive control technique. The MIMO DMC controller is implemented in a full-scope power plant simulator with satisfactory performance.

유한요소-경계요소 조합에 의한 3차원 유체저장 구조물의 주파수 응답해석 (Three Dimesional Analysis of Liquid Storage Tanks Using FE-BE Coupling Method in Frequency Domin)

  • 김문겸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1999년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.275-283
    • /
    • 1999
  • To predict the dynamic behavior of the cylindrical liquid storage tank subjected to seismic ground motion three dimesional analysis with liquid-structure interaction must be performed, In this study a three dimensional dynamic analysis method over the frequency domain using FE-BE coupling technique which combines the efficiency of the boundary elements for liquid with the versatility of the finite shell elements for tank. The liquid region is modeled using boundary elements which can counter the sloshing effect at free surface and the structure region the tank itself is modeled using the degenerated finite shell elements. At the beginning of the procedure the equivalent mass matrix of the liquid is generated by boundary elements procedure. Then this equivalent mass matrix is combined with the mass matrix of the structure to produce the global mass matrix in the equation of the motion of fluid-structure interaction problem In order to demonstrate the accuracy and validity of the developed method the numerical results re compared with the previous studies. Finally the effects of the fluid-structure interaction on the natural frequency and dynamic response of the system are analyzed.

  • PDF

재해석 기법을 이용한 동적 구조시스템의 System Identification (System Identification of Dynamic Systems Using Structural Reanalysis Method)

  • 한경봉;박선규;김형열
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 추계 학술발표회 제16권2호
    • /
    • pp.421-424
    • /
    • 2004
  • Model updating is a very active research field, in which significant efforts has been invested in recent years. Model updating methodologies are invariably successful when used on noise-free simulated data, but tend to be unpredictable when presented with real experimental data that are-unavoidably-corrupted with uncorrelated noise content. In this paper, Reanalysis using frequency response functions for correlating and updating dynamic systems is presented. A transformation matrix is obtained from the relationship between the complex and the normal frequency response functions of a structure. The transformation matrix is employed to calculate the modified damping matrix of the system. The modified mass and stiffness matrices are identified from the normal frequency response functions by using the least squares method. Full scale pseudo dynamic pier test is employed to illustrate the applicability of the proposed method. The result indicate that the damping matrix of correlated finite element model can be identified accurately by the proposed method. In addition, the robustness of the new approach uniformly distributed measurement noise is also addressed.

  • PDF

Enhanced generalized modeling method for compliant mechanisms: Multi-Compliant-Body matrix method

  • Lim, Hyunho;Choi, Young-Man
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.503-515
    • /
    • 2022
  • The multi-rigid-body matrix method (MRBMM) is a generalized modeling method for obtaining the displacements, forces, and dynamic characteristics of a compliant mechanism without performing inner-force analysis. The method discretizes a compliant mechanism of any type into flexure hinges and rigid bodies by implementing a multi-body mass-spring model using coordinate transformations in a matrix form. However, in this method, the deformations of bodies that are assumed to be rigid are inherently omitted. Consequently, it may yield erroneous results in certain mechanisms. In this paper, we present a multi-compliant-body matrix-method (MCBMM) that considers a rigid body as a compliant element, while retaining the generalized framework of the MRBMM. In the MCBMM, a rigid body in the MRBMM is segmented into a certain number of body nodes and flexure hinges. The proposed method was verified using two examples: the first (an XY positioning stage) demonstrated that the MCBMM outperforms the MRBMM in estimating the static deformation and dynamic mode. In the second example (a bridge-type displacement amplification mechanism), the MCBMM estimated the displacement amplification ratio more accurately than several previously proposed modeling methods.

99mTc-DTPA 신장 동적 검사(Renal Dynamic Scan) 시 동위원소 용량 변화와 Matrix Size 변경에 따른 사구체 여과율(Glomerular Filtration Rate, GFR) 수치 변화 비교 (Comparison of Activity Capacity Change and GFR Value Change According to Matrix Size during 99mTc-DTPA Renal Dynamic Scan)

  • 김현;도용호;김재일;최현준;우재룡;박찬록;하태환
    • 핵의학기술
    • /
    • 제24권1호
    • /
    • pp.27-32
    • /
    • 2020
  • 사구체 여과율은 신 기능의 평가와 신 질환의 경과 관찰에 중요한 지표다. 현재 임상에서 사구체 여과율을 측정하는 방법은 크게 혈청 크레아티닌 수치와 99mTc-DTPA을 이용해서 계산하는 검사가 유용하게 이용되고 있다. Gates 공식이 발표된 이후, 99mTc-DTPA Renal Dynamic Scan 검사시 이를 적용해 GFR을 감마카메라 장비를 이용하여 측정하고 있다. 본 논문의 목적은 Gates 공식을 적용해 사구체 여과율을 측정할 때 동위원소의 용량 변화, Matrix Size 변경에 따른 사구체 여과율을 분석해 보고자 한다. 본원에서 99mTc-DTPA Renal Dynamic Scan 검사를 받은 성인 환자 5명 (환자나이 = 62 ± 5, 남자 3명, 여자 2명)의 결과를 분석하였다. 99mTc-DTPA 15 mCi를 환자의 정맥에 순간 주사 후 21분간 동적 영상을 획득하였다. Activity, Matrix Size 변화에 따라 사구체 여과율을 평가하기 위해 2-3분 구간의 양쪽 신장과 조직에 관심 영역을 설정 후 총 계수를 측정하였다. Detector와 Table 간의 거리는 30cm로 유지하였고, 동위원소의 용량 변화 평가를 위해 Pre Syringe(PR)의 용량을 15, 20, 25, 30 mCi로 설정하였고, Post Syringe(PO)의 용량을 1, 5, 10, 15 mCi로 각각 설정하였다. 그리고 각각의 Matrix size를 32 × 32, 64 × 64, 128 × 128, 256 × 256, 512 × 512, 1024 × 1024로 변경하여 값을 비교 평가하였다. Matrix Size에서 동위원소의 용량이 증가할수록 사구체 여과율의 차이는 최대 52.95%에서 최소 16.67%로 점차 감소하였다. Matrix size 변화에 따른 사구체 여과율 값은 128에서 256, 256에서 512, 512에서 1024로 변경 시 2.4%, 0.2%, 0.2%로 유사하게 나타났으나, 32에서 64, 64에서 128로 변경 시 54.3 %, 39.43%로 GFR 값의 차이가 발생하였다. 마지막으로, 현재 사용 중인 256 Matrix, Pre syringe 15 mCi의 GFR 값을 기준으로 32 Matrix, Pre Syringe 15 mCi, Post Syringe 1 mCi 조건에서 82%로 가장 큰 차이가 발생하였고, 64 Matrix, Pre Syringe 30 mCi, Post Syringe 15 mCi의 조건에서 0.2%로 유사한 결과 값을 나타내었다. 본 논문을 통해 99mTc-DTPA Renal Dynamic Scan에서 Gates 공식을 이용해 사구체 여과율을 측정할 때, 동위원소의 용량과 Matrix Size 변화에 따라 사구체 여과율 측정에 영향이 있음을 확인하였다. 그러므로 각 병원에서 이를 적용해 GFR을 측정할 때 적절한 Parameter를 적용해서 검사의 유용성을 높아야 한다고 생각한다.