• 제목/요약/키워드: Dynamic magnetic field measurement

검색결과 18건 처리시간 0.025초

Dynamic Magnetic Field Measurement in the Air Gap of Magnetic Bearings Based on FBG-GMM Sensor

  • Jiayi, Liu;Zude, Zhou;Guoping, Ding;Huaqiang, Wang
    • Journal of the Optical Society of Korea
    • /
    • 제19권6호
    • /
    • pp.575-585
    • /
    • 2015
  • Magnetic field in magnetic bearings is the physical medium to realize magnetic levitation, the distribution of the magnetic field determines the operating performance of magnetic bearings. In this paper, a thin-slice Fiber Bragg Grating-Giant Magnetostrictive Material magnetic sensor used for the air gap of magnetic bearings was proposed and tested in the condition of dynamic magnetic field. The static property of the sensor was calibrated and a polynomial curve was fitted to describe the performance of the sensor. Measurement of dynamic magnetic field with different frequencies in magnetic bearings was implemented. Comparing with the finite element simulations, the results showed the DC component of the magnetic field was detected by the sensor and error was less than 5.87%.

교류 자기센서 특성 시험장치 설계에 관한 연구 (A Study on the Measurement System Design for Measuring Properties of AC Magnetic Field Sensor)

  • 정현주;양창섭;정우진
    • 한국군사과학기술학회지
    • /
    • 제18권3호
    • /
    • pp.244-252
    • /
    • 2015
  • This paper describes design and construction results of the measurement system developed on the purpose of measuring properties of AC magnetic field sensors used in the weapon system. The system for measuring the properties of AC magnetic field sensors consist of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and AC magnetic field sensor property measurement & analysis equipment including the operating software. By using this system, we can measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency from 1 Hz to 10 kHz. Finally we also verified its performance by measuring the property of a MAG 639, standard magnetic field sensor of bartington instruments, with the developed measurement system.

광대역 교류 자기센서 특성 시험장치 설계에 관한 연구 (A Study on the System Design for Measuring the Property of Broadband AC Magnetic Sensors)

  • 정현주;양창섭;정우진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.685-686
    • /
    • 2015
  • This paper describes design results of the measurement system to test the properties of broadband AC magnetic field sensors used in weapon system. This measurement system consists of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and measurement & analysis controller including the operating software. This system is able to measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency of 1 Hz to 10 kHz. The performance of this system was verified by measuring and analyzing the property of a MAG 639, standard magnetic field sensor of bartington instruments, with this developed system.

  • PDF

구동중인 자동차 배기계의 진동 특성 측정 (Vibration Measurement of an Automobile Exhaust System in Operation)

  • 김성국;이종남;한순우;정태진;이신영;장강원
    • 한국소음진동공학회논문집
    • /
    • 제17권3호
    • /
    • pp.235-240
    • /
    • 2007
  • In this work, the operational deflection shape(ODS) of an automobile exhaust system is measured by using a recently-developed magnetic sensor. The magnetic sensor is composed of a solenoid and two pairs of permanent magnets generating an antisymmetric magnetic field in the lateral direction inside the solenoid. Lateral movement of a ferromagnetic pipe inside the magnetic field of the suggested sensor induces an electromotive force in the solenoid corresponding to the lateral velocity of the pipe. Due to the simplicity and non-contact characteristics of the magnetic sensor, dynamic behaviors of the structures operating under high temperature such as an exhaust pipe can be efficiently observed. It is shown that the lateral ODS of an exhaust system can be successfully measured by the suggested sensors.

Performance Improvement of an INS by using a Magnetometer with Pedestrian Dynamic Constraints

  • Woyano, Feyissa;Park, Aangjoon;Lee, Soyeon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제6권1호
    • /
    • pp.1-9
    • /
    • 2017
  • This paper proposes to improve the performance of a strap down inertial navigation system using a foot-mounted low-cost inertial measurement unit/magnetometer by configuring an attitude and heading reference system. To track position accurately and for attitude estimations, considering different dynamic constraints, magnetic measurement and a zero velocity update technique is used. A conventional strap down method based on integrating angular rate to determine attitude will inevitably induce long-term drift, while magnetometers are subject to short-term orientation errors. To eliminate this accumulative error, and thus, use the navigation system for a long-duration mission, a hybrid configuration by integrating a miniature micro electromechanical system (MEMS)-based attitude and heading detector with the conventional navigation system is proposed in this paper. The attitude and heading detector is composed of three-axis MEMS accelerometers and three-axis MEMS magnetometers. With an absolute algorithm based on gravity and Earth's magnetic field, rather than an integral algorithm, the attitude detector can obtain an absolute attitude and heading estimation without drift errors, so it can be used to adjust the attitude and orientation of the strap down system. Finally, we verify (by both formula analysis and from test results) that the accumulative errors are effectively eliminated via this hybrid scheme.

Hyperpolarization: Sensitivity Boost in Magnetic Resonance Spectroscopy and Imaging

  • Ko, Hyeji;Gong, Gyeonghyeon;Jeong, Gijin;Choi, Ikjang;Seo, Hyeonglim;Lee, Youngbok
    • 한국자기공명학회논문지
    • /
    • 제19권3호
    • /
    • pp.124-131
    • /
    • 2015
  • Hyperpolarization methods are the most emerging techniques in the field of magnetic resonance (MR) researches since they make a contribution to overcoming sensitivity limitation of MR spectroscopy and imaging, leading to new fields of researches, real-time in vivo metabolic/molecular imaging and MR analysis of chemical/biological reactions in non-equilibrium conditions. Make use of enormous signal enrichments, it becomes feasible to investigate various chemical and biochemical systems with low ${\gamma}$ nuclei in real-time. This review deals with the theoretical principals of common hyperpolarization methods and their experimental features. In addition, more detailed theories, mechanisms, and applications of dissolution dynamic nuclear polarization (D-DNP) are discussed.

공기압용 전자밸브의 자장해석과 밸브설계에의 응용 (A study on Magnetic Field Analysis of Pneumatic Solenoid Valve and its Application to Valve Design)

  • 강보식;김형의
    • 한국기계연구소 소보
    • /
    • 통권20호
    • /
    • pp.41-48
    • /
    • 1990
  • Electro-pneumatic valves are an electro-mechanical device which convert electric signal into pneumatic flow rate or pressure signal. Recently, the development tendency of electro-pneumatic valve is to make the valve with more compact and less electric power consumption style. To make the valve such as a style, the role of solenoid part is very important. This paper is used in the finite-element method for the purpose of evaluating the magnetic property of solenoid and analyze flux distribution of solenoid theoretically. From flux contour line which is obtained by numerical analysis, it verified that the plunger shape and physical property of solenoid part have influence on saturation phenomenon and leakage of magnetic fluxs. This paper made an experiment on the measurement of dynamic response time and force in order to confirm the propety of analytic result, and confirmed a good agreement between analysis results and experiment results.

  • PDF

전동력설비의 운전에 의해 발생되는 자계의 측정과 해석 (Analysis and Measurement of the Magnetic Fields Cause by Operation of Electromotive Installations)

  • 이복희;길경석
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제9권2호
    • /
    • pp.58-67
    • /
    • 1995
  • 본 논문은 유도전동기의 운전조작시에 발생되는 자계변화특성에 대하여 기술하였다. 본 측정시스템은 자기적분형 자계센서, 증폭기, 능동형 적분기로 이루어졌으며, 교정실험에 대한 측정계의 주파수대역과 감도는 각각 20[Hz]~0.234[mV/$\mu$T]이다. 유도전동기의 기동과 정상운전중에 발생하는 자계성분을 측정하였으며, 고조파 성분을 고속 푸리에 변환기법으로 분석하였다. 유도전동기의 직입기동시에는 단일성 펄스자계가 강하게 발생하였으며, 이의 피크치는 정상상태의 값보다 5배이상 크게 나타났다. 이러한 긴 과도시간과 강한 자계의 세기는 전동기의 큰 인덕턴스와 동특성에 기인된다. 유도전동기의 정상운전시에는 유도전동기의 극수에 의존하는 기본파에 대한 분조파의 자계성분이 관측되었다. 또한, 자계의 분조파 성분은 전동기의 토크 변동으로 불균일한 회전토크로 인해 생기는 맥동전류와 전압플리커에 의해서 발생하는 것으로 생각된다. 인버터구동형 유도전동기에서는 직입기동에 비하여 많은 고조파 성분이 발생되고 있었으며, 특히 전동기의 구동주파수가 낮을수록 맥동토크에 의한 전류변화로 고조파 성분은 더욱 증가하였다.

  • PDF

포항방사광가속기 킼커 대출력 펄스전원장치 운전특성 (OPERATING CHARACTERISTICS OF THE PLS INJECTION KICKER MODULATOR)

  • 남상훈;정성훈;고인수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1800-1802
    • /
    • 1998
  • The Pohang Light Source (PLS) is a third generation 2 GeV synchrotron machine. An injection kicker modulator is positioned in the PLS storage ring tunnel. The kicker modulator is driving four kicker magnets simultaneously. The kicker magnets produce magnetic field to deflect the stored beam orbit in the storage ring closer to the injected beam from the PLS beam transfer line. The injected beam then falls into the storage ring beam dynamic aperture. The current kicker modulator was upgraded and installed on August 1995. Since then, the kicker modulator has shown very reliable and stable performance. The kicker modulator specifications are ${\sim}6.0{\mu}s$ full width, ${\sim}24$ kA peak current, and 10 Hz repetition rate. Output current waveform is a half sinusoid. Two thyratron switches(EEV CX-1536AX) are used in the kicker modulator. Total accumulated thyratron heater run hour is about 15,000 hours as of May 1998. Measurement result of spatial magnetic field distribution in the kicker magnet shows good uniformity.

  • PDF

Molecular Dynamics of the C-Terminal Domain Mouse CDT1 Protein

  • Khayrutdinov, Bulat I.;Bae, Won-Jin;Kim, Jeong-Ju;Hwang, Eun-Ha;Yun, Young-Mi;Ryu, Kyoung-Seok;Cheong, Hae-Kap;Kim, Yu-Gene;Cho, Yun-Je;Jeon, Young-Ho;Cheong, Chae-Joon
    • 한국자기공명학회논문지
    • /
    • 제11권1호
    • /
    • pp.30-41
    • /
    • 2007
  • The backbone molecular dynamics of the C-terminal part of the mouse Cdt1 protein (tCdt1, residues 420-557) was studied by high field NMR spectroscopy. The Secondary structure of this protein was suggested by analyzing of chemical shift of backbone atoms with programs TALOS and PECAN, together with NOE connectivities from 3D $^{15}N-HSQC-NOESY$ data. Measurement of dynamic parameters $T_1,\;T_2$ and NOE and limited proteolysis experiment provided information for domain organization of tCdt1(420-557). Analysis of the experimental data showed that the C-terminal part of the tCdt1 has well folded domain for residues 455-553. The residues 420-453 including ${\alpha}-helix$ (432-441) are flexible and probably belong to other functional domain in intact full length Cdt1 protein.

  • PDF