• 제목/요약/키워드: Dynamic exposure conditions

검색결과 31건 처리시간 0.026초

Color Capture Device의 저조도 감도 향상 방안 (Sensitivity Improvement Method for Color Capture Device At Low Illumination Conditions)

  • 김일도;전재성;최병선;박상규
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.235-236
    • /
    • 2007
  • CCD(Charge-Coupled Device) 혹은 CMOS (Complementary Metal Oxide Semiconductor)와 같은 소자를 이용하여 빛을 전기적 신호인 Image로 재구성하는 촬상소자(Color Capture Device)는 촬영환경이 어두워지면 Dynamic Range가 작아지고, Noise가 상대적으로 심해진다[1][2]. 본 논문에서는 촬영 환경이 어두울 때, Resolution을 Preserving하는 Pixel Pitch가 큰 촬상 소자와 Motion Blur를 억제하는 Exposure Time이 긴 촬상 소자의 조합을 신호처리로 구현하여, 신호의 Power를 향상시켜 Dynamic Range를 키우고 Noise의 Boost-up을 억제하여 SNR(Signal to Noise Ratio)을 향상시키는 방식으로, 촬상 장치의 감도를 향상시켜 화질을 개선하는 방법을 제안한다.

  • PDF

현장 해양 콘크리트의 동탄성계수와 정탄성계수 분석 (Analysis of Dynamic and Static Elastic Modulus of In-situ Marine Concrete)

  • 한상훈;박우선
    • 한국해안·해양공학회논문집
    • /
    • 제21권6호
    • /
    • pp.437-443
    • /
    • 2009
  • 콘크리트 구조물의 안전성이나 내구성을 파악하기 위해 비파과 검사를 실시하는데, 충격공진법을 이용하면 동탄성계수를 얻을 수 있다. 동탄성계수는 일축압축실험에서 얻을 수 있는 일반적인 정탄성계수와는 절대값에서 차이가 있다. 본 연구에서는 현장 항만 콘크리트 구조물에서 채취된 코어시료에 대한 실내실험을 통해 동탄성계수와 정탄성계수의 상관관계를 규명하고자 하였다. 현장 항만 콘크리트 코어는 완도항, 마산항, 인천항에서 채취하였으며, 노출환경에 따라 대기부, 비말대, 간만대로 나누어 작업을 실시하였다. 채취된 시료는 실험실로 이송하여 충격공진법과 일축압축실험을 실시하였다. 충격공진법을 이용하면 개별시료의 공진주파수를 측정할 수 있으며, 이를 바탕으로 동탄성계수를 계산할 수 있다. 일축압축실험을 수행하면 시료의 응력-변형률 곡선을 얻을 수 있는데, 이를 바탕으로 일반적으로 설계에 사용되는 정탄성계수(현탄성계수)와 낮은 응력수준의 초기현탄성계수를 구하였다. 동탄성계수와 정탄성계수 및 초기현탄성계수의 상관관계는 채취 지역에 따라 차이가 있었지만 같은 안벽 내에서의 노출 환경에 따라서는 거의 차이가 없었다. 또한, 압축강도와 동탄성계수의 상관관계도 코어채취지역에 따라 조금씩 차이가 있었다. 그러나, 압축강도와 정탄성계수는 코어채취지역에 따라 차이가 발생하지 않았다.

한국인 앉은 자세에 대한 수직방향의 전신진동 피폭에 대한 겉보기 질량의 실험적 연구 (Experimental investigation on the apparent mass during exposure to whole-body vertical vibration for Korean-seated postures)

  • 김영태;정완섭;윤용산
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.241-245
    • /
    • 2003
  • When considering the effects of whole-body vertical vibration, it is valuable to have an understanding of the mechanical characteristics (mechanical impedance and apparent mass) of the body. This paper addresses experimental results carried out to investigate the characteristics of apparent masses fer 41 Korean. The apparent masses of the seated human body in vertical direction were measured during different experimental conditions, such as vibration excitation level (0.5-2 ms$\^$-2/ r.m.s). frequency range (1-50Hz), and upper body posture (relaxed, normal and backrest-upright). We showed the average of all subjects and all conditions and compared the results with ISO5982/DIS (2000).

  • PDF

콘크리트의 동결융해 내구성에 공기량, 제설제, 노출조건이 미치는 영향에 관한 연구 (Effect of Air Contents, Deicing Salts, and Exposure Conditions on the Freeze-Thaw Durability of the Concrete)

  • 이병덕
    • 한국도로학회논문집
    • /
    • 제12권2호
    • /
    • pp.107-113
    • /
    • 2010
  • 콘크리트의 박리(scaling)는 수분의 존재하에 동결융해 싸이클에 따른 콘크리트의 점진적인 표면열화이다. 특히, 이것은 제설제에 염화물의 존재가 콘크리트 표면박리(스켈링)와 더불어 심한 경우, 굵은골재의 노출 및 탈리로 이어질 수 있다. 본 연구에서는 콘크리트의 스켈링에 대한 저염화물계 제설제(low chloride deicier, LCD)와 염화칼슘 및 염화나트륨 제설제의 상대적인 영향을 ASTM C672에 준하여 실시하였다. 시험 제설제의 농도는 1, 4, 10% 이고, 수돗물은 기준으로 사용하였다. 박리량은 중량으로 평가하였다. 연구결과 4% 농도를 적용하였을 때, 동결융해 56 싸이클 후 콘크리트의 박리는 수돗물에 비해 LCD 용액에서 약 9배, 염화칼슘 용액에서 약 18배, 염화나트륨 용액에서 약 33배 정도 크게 발생하였다. 용액의 농도에 따라서는 고농도인 10%에 비해 4% 농도에서 표면 박리가 가장 현저하게 발생하였는데, 이는 스켈링 발생이 염농도가 3~4%일 때 가장 현저해진다는 기존의 연구결과와 일치함을 알 수 있었다(일본콘크리트공학회, 1999). 또한 콘크리트가 경화된 후, 현장에서 염화나트륨 및 저염화물계 제설제(LCD, 염소이온 중량비 50%)가 살포되고 동결융해 싸이클에 노출된 경우, 제설제에 노출되지 않은 경우의 콘크리트 동해열화에 대해, 콘크리트의 공기량에 따른 영향을 실험적으로 연구하였다. 연구 결과 동결융해 싸이클에 따른 콘크리트 시편은 제설제에 노출되지 않은 것 보다 염화물 제설제 노출에서 스켈링이 더 심한 것으로 나타났고, 염화물 제설제에 노출된 시편이 노출되지 않은 시편 보다 중량 손실이 2배나 되었다. 콘크리트 시편의 상대 동탄성계수는 염화물 제설제에 노출되지 않은 것과 비교하여 염화물 제설제에 노출된 것에서 더 빠르게 감소하였다. 또한 염화나트륨 제설제에 노출된 콘크리트 시편의 상대 동탄성계수는 저염화물계 제설제에 노출된 것 보다 더 빠르게 감소하였다. AE 콘크리트는 염화물과 동결융해 싸이클에 노출되었을 때, Non-AE 콘크리트 보다 성능저하가 크게 지연되었다.

COHERENT AND CONVEX HEDGING ON ORLICZ HEARTS IN INCOMPLETE MARKETS

  • Kim, Ju-Hong
    • Journal of applied mathematics & informatics
    • /
    • 제30권3_4호
    • /
    • pp.413-428
    • /
    • 2012
  • Every contingent claim is unable to be replicated in the incomplete markets. Shortfall risk is considered with some risk exposure. We show how the dynamic optimization problem with the capital constraint can be reduced to the problem to find an optimal modified claim $\tilde{\psi}H$ where$\tilde{\psi}H$ is a randomized test in the static problem. Convex and coherent risk measures defined in the Orlicz hearts spaces, $M^{\Phi}$, are used as risk measure. It can be shown that we have the same results as in [21, 22] even though convex and coherent risk measures defined in the Orlicz hearts spaces, $M^{\Phi}$, are used. In this paper, we use Fenchel duality Theorem in the literature to deduce necessary and sufficient optimality conditions for the static optimization problem using convex duality methods.

미세 3차원 구조물 제조를 위한 디지털 마이크로미러소자 응용 마이크로 광조형 (Digital Micromirror Device Based Microstereolithography for the Fabrication of 3D Microstructures)

  • 주재영;김성훈;정성호
    • 한국레이저가공학회지
    • /
    • 제9권1호
    • /
    • pp.1-7
    • /
    • 2006
  • In order to increase the productivity of conventional microstereolithography (MSL), digital micromirror device($DMD^{TM}$) based MSL is proposed and the feasibility of 3D rnicrocomponents fabrication is demonstrated in two ways; free surface and constrained surface techniques. The clearness of optical images at the exposure plane was confirmed for the fabrication of an accurate 3D structure by controlling the dynamic viscosity of FA1260T and the shape accuracy of a structure fabricated with epoxy-based resin ($Somos^{\circledR}$ 10120) was analyzed to determine the optimum curing conditions. After finding the appropriate process variables, the feasibility of multiple microstructures is then demonstrated. Due to the high productivity, MSL using $DMD^{TM}$ showed the potential to replace the existing focused laser beam MSL.

  • PDF

인체 두부에서 Dynamic Tomogram의 응용에 관한 연구 (A STUDY ON THE APPLICATION OF DYNAMIC TOMOGRAM OF THE HUMAN HEAD)

  • 최의환;김재덕
    • 치과방사선
    • /
    • 제21권2호
    • /
    • pp.317-326
    • /
    • 1991
  • The purpose of this study was to establish the principle and the clinical application of dynamic tomogram of a human head by using the dental machine. For this study, a block of wax with details lying at three parallel planes and a human dry skull were used. This experiment was reexamined the dynamic tomogram with specialized radiographic device and view box, and the radiograms taken by the change of exposure time according to the numbers of film used in x-ray taking and taken according to the change of kVp and the types of film were analyzed density with the densitometer. From this study, the obtained results were as follows: 1. When the underexposed radiograms taken by angulation of clockwise and counter-clockwise direction of the film and skull. were superimposed and moved laterally, it was possible to focus on right and left jaws and teeth. 2. The superimposition of the two underexposed radiograms according to each condition of x-ray taking showed some differencies in density visually, and the measurement of density with the densitometer was 1.23 to 1.57 in 75kVp and 1.34 to 1.70 in 90kVp. 3. The superimposition of the two underexposed radiograms according to the kinds of x-ray film showed almost equal density visually, and the measurement of density with the densiometer was 1.34 to 1.37. 4. When seven radiograms taken by each condition of x-ray taking were superimposed on the view box, a intense rear light of view box didn't transilluminate film density regardless of the conditions of x-ray taking. Even though seven radiograms taken according to types of film were superimposed on the view box, a more intense rear light of view box was required to transilluminate total density of films. 6. Long film-object distance resulted in the enlargement and blurring of radiographic images.

  • PDF

진동대 시험에 의한 편평한 암석 절리면의 동적 마찰거동 특성 (Dynamic Frictional Behavior of Saw-cut Rock Joints Through Shaking Table Test)

  • 박병기;전석원
    • 터널과지하공간
    • /
    • 제16권1호
    • /
    • pp.58-72
    • /
    • 2006
  • 암반구조물의 규모가 점차 대형화됨에 따라 암반이 자유면에 노출되는 확률이 높아지고 있으며, 최근 들어 지진이나 발파, 고속철도의 운행에 의한 진동 등으로 야기되는 동적 하중의 발생빈도가 증가하는 추세이므로 동적 하중조건 하에서 암반 불연속면의 거동 특성 파악을 위한 연구의 필요성이 증대되고 있다. 본 연구에서는 자유면에 노출된 블록의 동적 거동을 모사할 수 있도록 경사면 진동대 시험장비를 제작하였고, 다양한 동적 하중 조건하에서 편평한 화강암 절리면의 마찰 거동 특성을 분석하였다. 경사시험을 통해서 구한 한계 경사각과 진동하중 하에서의 임계가속도로부터 역산한 정적 마찰각을 비교한 결과 동하중 하에서 정적마찰각이 $4.5\~8.2^{\circ}$ 정도 낮게 산정되는 경향을 보였다. 이론적인 암석 블록의 마찰 거동을 표현하는 블록 거동 프로그램을 작성하고, 진동하중에 의해 미끄러지는 암석 블록의 가속도 및 변위 계측결과를 개발된 프로그램에 의한 결과와 비교하여 암석 절리면의 동적 마찰각을 산정하였는데 동적 마찰각 역시 한계 경사각에 비해 $2.0\~7.5^{\circ}$ 정도 감소하는 결과를 얻었다. 동하중 하에서 측정된 정적 마찰각과 동적 마찰각은 가해진 가속도의 크기나 진폭 등의 하중 특성과 기하조건에 따라 달라지는 경향을 보였다. 개별요소 프로그램을 이용하여 진동대 시험을 모사하였는데, 계측결과 및 개발된 프로그램에 의한 결과와 비교적 잘 일치하였다. 진동대 시험에 의한 동적, 정적 마찰각은 직접전단시험에 의한 기본 마찰각보다 현저히 작게 산정되었다.

진동하중 하에서 거친 암석 절리면의 동력 마찰거동 (Dynamic Frictional Behavior of Artificial Rough Rock Joints under Dynamic Loading)

  • 전석원;박병기
    • 터널과지하공간
    • /
    • 제16권2호
    • /
    • pp.166-178
    • /
    • 2006
  • 암반구조물의 대형, 대단면화에 따라 자유면에 노출된 암반블록의 거동특성 평가가 더욱 중요해지고 있으며, 최근 들어 지진이나 발파, 고속철도의 운행에 의한 진동 등으로 야기되는 동적하중의 발생빈도가 증가하는 추세이므로 동적 하중조건 하에서 암반 절리의 거동특성 파악을 위한 연구의 필요성이 증대되고 있다. 본 연구에서는 거친 절리면의 동적 마찰거동 특성 파악을 위해 인공 인장절리시료를 제작하고 3차원 표면거칠기 측정을 통해 인장절리면의 거칠기 특성을 분석하였으며, 다양한 조건에서 진동대 시험을 수행하였다. 절리면이 맞물린 조건에서 경사시험을 통해 구한 한계 경사각과 진동하중 하에서의 임계가속도로부터 역산한 정적 마찰각을 비교한 결과 동하중 하에서 정적 마찰각이 평균 $2.7^{\circ}$ 정도 낮게 산정되는 경향을 보였다. 엇물린 상태에서 진동하중에 의해 미끄러지는 암석블록의 가속도 및 변위 계측결과를 블록거동 프로그램에 의한 결과와 비교하여 동적 마찰각을 산정하였는데 동적 마찰각 역시 한계 경사각에 비해 평균 $1.8^{\circ}$ 감소하는 결과를 얻었다. 미끄러짐 변위패턴을 4가지로 분류하였으며 이는 절리면의 1차 거칠기와 관련있는 것으로 나타났다. 절리면이 맞물린 상태에서 측정된 한계 경사각과 정적 마찰각은 2차 거칠기를 표현하는 파라미터인 평균 거 각과 상관성을 가지는 것으로 보이나, 엇물린 상태에서 측정된 한계 경사각과 동적 마찰각은 거칠기 파라미터와 특별한 상관성을 파악할 수 없었다. 진동대 시험에 의한 동적, 정적 마찰각은 직접전단시험에 의한 마찰각 결과보다 작게 산정되었다.

Myocardial Coverage and Radiation Dose in Dynamic Myocardial Perfusion Imaging Using Third-Generation Dual-Source CT

  • Masafumi Takafuji;Kakuya Kitagawa;Masaki Ishida;Yoshitaka Goto;Satoshi Nakamura;Naoki Nagasawa;Hajime Sakuma
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.58-67
    • /
    • 2020
  • Objective: Third-generation dual-source computed tomography (3rd-DSCT) allows dynamic myocardial CT perfusion imaging (dynamic CTP) with a 10.5-cm z-axis coverage. Although the increased radiation exposure associated with the 50% wider scan range compared to second-generation DSCT (2nd-DSCT) may be suppressed by using a tube voltage of 70 kV, it remains unclear whether image quality and the ability to quantify myocardial blood flow (MBF) can be maintained under these conditions. This study aimed to compare the image quality, estimated MBF, and radiation dose of dynamic CTP between 2ndDSCT and 3rd-DSCT and to evaluate whether a 10.5-cm coverage is suitable for dynamic CTP. Materials and Methods: We retrospectively analyzed 107 patients who underwent dynamic CTP using 2nd-DSCT at 80 kV (n = 54) or 3rd-DSCT at 70 kV (n = 53). Image quality, estimated MBF, radiation dose, and coverage of left ventricular (LV) myocardium were compared. Results: No significant differences were observed between 3rd-DSCT and 2nd-DSCT in contrast-to-noise ratio (37.4 ± 11.4 vs. 35.5 ± 11.2, p = 0.396). Effective radiation dose was lower with 3rd-DSCT (3.97 ± 0.92 mSv with a conversion factor of 0.017 mSv/mGy∙cm) compared to 2nd-DSCT (5.49 ± 1.36 mSv, p < 0.001). Incomplete coverage was more frequent with 2nd-DSCT than with 3rd-DSCT (1.9% [1/53] vs. 56% [30/54], p < 0.001). In propensity score-matched cohorts, MBF was comparable between 3rd-DSCT and 2nd-DSCT in non-ischemic (146.2 ± 26.5 vs. 157.5 ± 34.9 mL/min/100 g, p = 0.137) as well as ischemic myocardium (92.7 ± 21.1 vs. 90.9 ± 29.7 mL/min/100 g, p = 0.876). Conclusion: The radiation increase inherent to the widened z-axis coverage in 3rd-DSCT can be balanced by using a tube voltage of 70 kV without compromising image quality or MBF quantification. In dynamic CTP, a z-axis coverage of 10.5 cm is sufficient to achieve complete coverage of the LV myocardium in most patients.