• Title/Summary/Keyword: Dynamic diagnosis

Search Result 362, Processing Time 0.03 seconds

Sewer Decontamination Mechanism and Pipe Network Monitoring and Fault Diagnosis of Water Network System Based on System Analysis (시스템 해석에 기초한 하수관망 오염 매카니즘과 관망 모니터링 및 이상진단)

  • Kang, OnYu;Lee, SeungChul;Kim, MinJeong;Yu, SuMin;Yoo, ChangKyoo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.980-987
    • /
    • 2012
  • Nonpoint source pollution causes leaks and overtopping, depending on the state of the sewer network as well as aggravates the pollution load of the aqueous water system as it is introduced into the sewer by wash-off. According, the need for efficient sewer monitoring system which can manage the sewage flowrate, water quality, inflow/infiltration and overflow has increased for sewer maintenance and the prevention of environmental pollution. However, the sewer monitoring is not easy since the sewer network is built in underground with the complex nature of its structure and connections. Sewer decontamination mechanism as well as pipe network monitoring and fault diagnosis of water network system on system analysis proposed in this study. First, the pollution removal pattern and behavior of contaminants in the sewer pipe network is analyzed by using sewer process simulation program, stormwater & wastewater management model for expert (XP-SWMM). Second, the sewer network fault diagnosis was performed using the multivariate statistical monitoring to monitor water quality in the sewer and detect the sewer leakage and burst. Sewer decontamination mechanism analysis with static and dynamic state system results showed that loads of total nitrogen (TN) and total phosphorous (TP) during rainfall are greatly increased than non-rainfall, which will aggravate the pollution load of the water system. Accordingly, the sewer outflow in pipe network is analyzed due to the increased flow and inflow of pollutant concentration caused by rainfall. The proposed sewer network monitoring and fault diagnosis technique can be used effectively for the nonpoint source pollution management of the urban watershed as well as continuous monitoring system.

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF

MR Findings of Papillary Neoplasms of the Breast (유두 종양의 자기공명 영상소견)

  • Jo, Yeseul;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.43-51
    • /
    • 2014
  • Purpose : To review MR imaging finding of papillary lesion identified as additional suspicious lesion on MR image in women with biopsy-proven breast cancer and to evaluate upgrading rates after subsequent surgical histopathological diagnosis. Materials and Methods: Among 1729 preoperative MR image of women with biopsy proven breast cancer, US-guided CNB-proven 22 papillary lesions from 21 patients, which showed additional suspicious contrast enhancement other than index cancer on MR image, were subjected to the study. Some of these lesions underwent surgery, thus the comparisons between the histopathologic results were able to be compared to the results of US-guided CNB. Also retrospective analysis was done for MR findings of these lesions by BI-RADS MRI lexicon. Results: On MR imaging, 8 mass lesions, 7 non-mass lesions, 7 focus lesions were detected. All of the focus lesion (100%, 7/7) was diagnosed as benign lesion and showed plateau and washout pattern in dynamic MR image. After excisional biopsy, one of 9 benign papilloma (11.1%), 3 of 3 papillary neoplasm with atypia component (100%), 3 of 5 papillary neoplasm (60%) were upgraded to malignancy such as ductal carcinoma in situ (DCIS), invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC). Conclusion: The MR images of papillary lesions diagnosed by US-guided CNB exhibit no significant differences between malignancy and benign lesion. Also 41.2% of the lesion (7/17) was upgraded after subsequent surgery. Thus all of the papillary lesions require excisional biopsy for definite diagnosis and the MR imaging, it's just not enough by itself.

Process Fault Probability Generation via ARIMA Time Series Modeling of Etch Tool Data

  • Arshad, Muhammad Zeeshan;Nawaz, Javeria;Park, Jin-Su;Shin, Sung-Won;Hong, Sang-Jeen
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.241-241
    • /
    • 2012
  • Semiconductor industry has been taking the advantage of improvements in process technology in order to maintain reduced device geometries and stringent performance specifications. This results in semiconductor manufacturing processes became hundreds in sequence, it is continuously expected to be increased. This may in turn reduce the yield. With a large amount of investment at stake, this motivates tighter process control and fault diagnosis. The continuous improvement in semiconductor industry demands advancements in process control and monitoring to the same degree. Any fault in the process must be detected and classified with a high degree of precision, and it is desired to be diagnosed if possible. The detected abnormality in the system is then classified to locate the source of the variation. The performance of a fault detection system is directly reflected in the yield. Therefore a highly capable fault detection system is always desirable. In this research, time series modeling of the data from an etch equipment has been investigated for the ultimate purpose of fault diagnosis. The tool data consisted of number of different parameters each being recorded at fixed time points. As the data had been collected for a number of runs, it was not synchronized due to variable delays and offsets in data acquisition system and networks. The data was then synchronized using a variant of Dynamic Time Warping (DTW) algorithm. The AutoRegressive Integrated Moving Average (ARIMA) model was then applied on the synchronized data. The ARIMA model combines both the Autoregressive model and the Moving Average model to relate the present value of the time series to its past values. As the new values of parameters are received from the equipment, the model uses them and the previous ones to provide predictions of one step ahead for each parameter. The statistical comparison of these predictions with the actual values, gives us the each parameter's probability of fault, at each time point and (once a run gets finished) for each run. This work will be extended by applying a suitable probability generating function and combining the probabilities of different parameters using Dempster-Shafer Theory (DST). DST provides a way to combine evidence that is available from different sources and gives a joint degree of belief in a hypothesis. This will give us a combined belief of fault in the process with a high precision.

  • PDF

Dynamic Analysis of 3 Different Cross-Sectional Shapes of a Fill Dam using 3D FEM Analysis (3차원 유한요소해석에 의한 필 댐의 3가지 단면 형상을 고려한 지진해석)

  • Choi, Byoungil
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.8
    • /
    • pp.37-43
    • /
    • 2015
  • Dam movements are identified in real-time with measuring instruments for dam maintenance. However, for dams that have aged, the measuring instruments that were installed during the dam construction are frequently malfunctioning or completely failing altogether. Precision safety diagnosis is being executed for dams that are national facilities Type 1. During the diagnosis, a safety assessment is conducted for the dam body. Normally, during the analysis of dam safety, the widest cross-section is selected and a two-dimensional numerical analysis is taken place for the cross-section. However, numerous researchers have recently looked into applying the 3-dimensional numerical analysis program developments to precisely analyze the structure of the dam, as well as the surrounding strata, and the lower dam strata. In this study, PLAXIS 3D, a geotechnical generic FEM analysis program, was used to conduct dam safety assessments for earthquakes. The following were compared and analyzed: considering the seismic properties of the dam body with all zoned structures reflected as one rock-fill zone together with the dam body, considering the dam body as the rock-fill zone and the core zone, and the numerical analysis results. Thus, the study was aimed to analyze the impact properties of seismic waves according to the different zones.

POST-EXTUBATION ACUTE RESPIRATORY DISTRESS SYNDROME OCCURRED IN THE ORTHOGNATHIC SURGERY PATIENT : A CASE REPORT (악교정 수술 환자에서 발관 후 발생된 급성 호흡곤란 증후군 : 증례보고)

  • Park, Ji-Young;Lee, Jung-A;Yun, Sung-Hun;Park, Min-Kyou;Kim, Chang-Hyun;Park, Je-Uk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.29 no.1
    • /
    • pp.79-84
    • /
    • 2007
  • Acute respiratory distress syndrome(ARDS) is severe acute hypoxic respiratory failure state with dynamic impairment in oxygen and carbon dioxide transfer with the need for high levels of supplementary oxygen and a high minute ventilation. This syndrome is caused by pulmonary edema due to increased permeability of the alveolar capillary barrier by various factors. ARDS is an uncommon, but a potentially life-threatening complication. Therefore, immediate diagnosis and appropriate therapy must be performed. The present case is post-extubation ARDS immediately occurred in an orthognathic surgery patient who are healthy 19-year-old man. He rapidly recovered from ARDS without complication by early diagnosis and proper treatment. This case report was aimed to describe the process of the development, possible causes and the management of ARDS occurred in an orthognathic surgery patient

Establishment of the large-scale longitudinal multi-omics dataset in COVID-19 patients: data profile and biospecimen

  • Jo, Hye-Yeong;Kim, Sang Cheol;Ahn, Do-hwan;Lee, Siyoung;Chang, Se-Hyun;Jung, So-Young;Kim, Young-Jin;Kim, Eugene;Kim, Jung-Eun;Kim, Yeon-Sook;Park, Woong-Yang;Cho, Nam-Hyuk;Park, Donghyun;Lee, Ju-Hee;Park, Hyun-Young
    • BMB Reports
    • /
    • v.55 no.9
    • /
    • pp.465-471
    • /
    • 2022
  • Understanding and monitoring virus-mediated infections has gained importance since the global outbreak of the coronavirus disease 2019 (COVID-19) pandemic. Studies of high-throughput omics-based immune profiling of COVID-19 patients can help manage the current pandemic and future virus-mediated pandemics. Although COVID-19 is being studied since past 2 years, detailed mechanisms of the initial induction of dynamic immune responses or the molecular mechanisms that characterize disease progression remains unclear. This study involved comprehensively collected biospecimens and longitudinal multi-omics data of 300 COVID-19 patients and 120 healthy controls, including whole genome sequencing (WGS), single-cell RNA sequencing combined with T cell receptor (TCR) and B cell receptor (BCR) sequencing (scRNA(+scTCR/BCR)-seq), bulk BCR and TCR sequencing (bulk TCR/BCR-seq), and cytokine profiling. Clinical data were also collected from hospitalized COVID-19 patients, and HLA typing, laboratory characteristics, and COVID-19 viral genome sequencing were performed during the initial diagnosis. The entire set of biospecimens and multi-omics data generated in this project can be accessed by researchers from the National Biobank of Korea with prior approval. This distribution of large-scale multi-omics data of COVID-19 patients can facilitate the understanding of biological crosstalk involved in COVID-19 infection and contribute to the development of potential methodologies for its diagnosis and treatment.

Primary Colonic Epithelioid Angiosarcoma with Hepatic Metastasis: A Case Report (간전이를 동반한 대장 상피모양혈관육종: 증례 보고)

  • Jiyun Lim;Seong Sook Hong;Jiyoung Hwang;Hyun-joo Kim;So-Young Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.2
    • /
    • pp.432-438
    • /
    • 2022
  • Colonic angiosarcoma is an extremely rare and aggressive malignant tumor with poor prognosis. We report a case of colonic epithelioid angiosarcoma with colonic obstruction and rapidly progressive hepatic metastasis in a 44-year-old female. Abdominal CT revealed a heterogeneously enhancing irregular mass in the ascending colon, causing proximal bowel distension. The patient underwent surgery, and histopathological examination revealed a poorly differentiated carcinoma. A follow-up liver dynamic MRI after 4 months revealed newly developed diffusely scattered numerous small nodules in both hepatic lobes with peripheral and nodular marked arterial hyperenhancement, raising the suspicion of hepatic angiosarcoma. A pathologic second opinion was obtained, and additional immunohistochemistry revealed colonic epithelioid angiosarcoma. The patient showed progressive hepatic metastasis on follow-up abdominal CT after 6 months and died 8 months after initial diagnosis. We describe an educational case of colonic angiosarcoma, a rare malignant tumor, with rapidly progressive hepatic metastasis that showed radiologic findings suggestive of angiosarcoma and enabled a re-diagnosis for proper treatment and prognosis prediction.

Small Animal PET Imaging Study of 68Ga-BAPEN (68Ga-BAPEN 소동물 PET영상 연구)

  • Kim, Ji-Who;Lee, Jae-Sung;Yang, Bo-Yeun;Kim, Su-Jin;Kim, Joong-Hyun;Jeong, Jae-Min;Lee, Dong-Soo
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.172-177
    • /
    • 2011
  • The purpose of this study was to analyze $^{68}Ga$-BAPEN dynamic PET image in rat myocardium to evaluate potential of this radiotracer as a perfusion imaging agent. Animal PET/CT scan was done in 9 rats during 120 minutes. Especially we synthesized $^{68}Ga$-BAPEN with kit which is simple and low cost method. PET images showed the in vivo dynamic distribution of $^{68}Ga$-BAPEN in the chest region of rats. Initially $^{68}Ga$-BAPEN PET images showed aorta and liver activities and a few minutes later, $^{68}Ga$-BAPEN moved to myocardium. Regions of interest were drawn on myocardium, liver, lung and blood pool. Time-activity curves showed significant uptake of $^{68}Ga$-BAPEN in myocardium. The contrast ratios of myocardial to blood pool, lung and liver at 60 minutes after injection were 1.66, 2.82 and 0.60. To estimate accurate kinetic parameters, 60 minutes after injection was required to PET scan as myocardium image contrast ratios reached to constant values. As a result, $^{68}Ga$-BAPEN would be suitable radiotracer for PET which can applied to diagnosis of myocardial perfusion diseases after further preclinical and clinical investigations.

Characteristics of Vibration Response Imaging in Healthy Koreans

  • Choi, Kyu-Hee;Kim, Kwan-Il;Bang, Ji-Hyun;Kim, Jae-Hwan;Choi, Jun-Yong;Jung, Sung-Ki;Jung, Hee-Jae
    • The Journal of Korean Medicine
    • /
    • v.32 no.6
    • /
    • pp.10-17
    • /
    • 2011
  • Background: Vibration response imaging (VRI) is a new technology that records energy generated by airflow during the respiration cycle. Analysis of lung sound using VRI may overcome the limitations of auscultation. Objectives: To set a VRI standard for healthy Koreans, we conducted a clinical assessment to evaluate breath sound images and quantification in healthy subjects and compared the findings with reported breath sound characteristics. Methods: Recordings were performed using the VRIxp. Eighty subjects took a deep breath four times during a 12-second interval while sitting upright. The quantitative aspect was analyzed using the VRI quantitative lung data (QLD) for total left lung, total right lung and for six lung regions: left upper lung (LUL), left middle lung (LML), left lower lung (LLL), right upper lung (RUL), right middle lung (RML), right lower lung (RLL). The qualitative aspect was provided through image assessments by three reviewers. Results: In all regions the left lung had significantly higher QLD than the right lung (P<0.005, paired t-test). The inter-rater agreement was 0.78. 84% of the images were found normal by the final assessment. Among the 16% (n=13) of images with abnormal final assessment, the most common flawed features were dynamic image (77%, n=10) and maximum energy frame (MEF) shape (77%, n=10). No significant differences were found between males and females for QLD but there were significant differences in qualitative aspects including dynamic images, MEF shape, and missing LLL. Conclusion: The characteristics of healthy Koreans are similar to those of Western subjects reported previously. VRI is easy to use and objective, and so is helpful to diagnose patients with respiratory diseases and to monitor the progress of diseases after medical treatments.