• 제목/요약/키워드: Dynamic diagnosis

검색결과 368건 처리시간 0.022초

Regulation of post-translational modification in breast cancer treatment

  • Heo, Kyung-Sun
    • BMB Reports
    • /
    • 제52권2호
    • /
    • pp.113-118
    • /
    • 2019
  • The small ubiquitin-related modification molecule (SUMO), one of the post-translational modification molecules, is involved in a variety of cellular functions where it regulates protein activity and stability, transcription, and cell cycling. Modulation of protein SUMOylation or deSUMOylation modification has been associated with regulation of carcinogenesis in breast cancer. In the dynamic processes of SUMOylation and deSUMOylation in a variety of cancers, SUMO proteases (SENPs), reverse SUMOylation by isopeptidase activity and SENPs are mostly elevated, and are related to poor patient prognosis. Although underlying mechanisms have been suggested for how SENPs participate in breast cancer tumorigenesis, such as through regulation of target protein transactivation, cancer cell survival, cell cycle, or other post-translational modification-related machinery recruitment, the effect of SENP isoform-specific inhibitors on the progression of breast cancer have not been well evaluated. This review will introduce the functions of SENP1 and SENP2 and the underlying signaling pathways in breast cancer for use in discovery of new biomarkers for diagnosis or therapeutic targets for treatment.

회전근개 파열의 수술적 치료 후 회전근개 초음파 소견 (Postoperative Ultrasound Findings of the Rotator Cuff Tendon after Arthroscopic Repair of a Rotator Cuff Tear)

  • 권동락
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.64-69
    • /
    • 2020
  • Ultrasound (US) imaging is an efficient, easy to use, rapid, dynamic, noninvasive, with rare side-effects and inexpensive tool allowing for facilitated diagnosis and management of the painful shoulder. It also has advantages over other imaging modalities in the evaluation of the postoperative shoulder for rotator cuff integrity and correct anchor and suture placement, as well as rotator cuff analysis following repair surgery. Early postoperative tendons frequently had a hypo- echoic echo texture and the absence of a fibrillar pattern, which might be misinterpreted as recurrent tears. however, these features often normalized into tendons with an increased echo texture and the reappearance of a fibrillar pattern at 6 months. Based on these sequential findings, the US findings within 3 months after surgery should be interpreted with caution to accurately understand and monitor the repaired tendon status.

Performance Evaluation of Pixel Clustering Approaches for Automatic Detection of Small Bowel Obstruction from Abdominal Radiographs

  • Kim, Kwang Baek
    • Journal of information and communication convergence engineering
    • /
    • 제20권3호
    • /
    • pp.153-159
    • /
    • 2022
  • Plain radiographic analysis is the initial imaging modality for suspected small bowel obstruction. Among the many features that affect the diagnosis of small bowel obstruction (SBO), the presence of gas-filled or fluid-filled small bowel loops is the most salient feature that can be automatized by computer vision algorithms. In this study, we compare three frequently applied pixel-clustering algorithms for extracting gas-filled areas without human intervention. In a comparison involving 40 suspected SBO cases, the Possibilistic C-Means and Fuzzy C-Means algorithms exhibited initialization-sensitivity problems and difficulties coping with low intensity contrast, achieving low 72.5% and 85% success rates in extraction. The Adaptive Resonance Theory 2 algorithm is the most suitable algorithm for gas-filled region detection, achieving a 100% success rate on 40 tested images, largely owing to its dynamic control of the number of clusters.

Quantitative real-time PCR assays for the concurrent diagnosis of infectious laryngotracheitis virus, Newcastle disease virus and avian metapneumovirus in poultry

  • Mo, Jongseo;Angelichio, Michael;Gow, Lisa;Leathers, Valerie;Jackwood, Mark W.
    • Journal of Veterinary Science
    • /
    • 제23권2호
    • /
    • pp.21.1-21.7
    • /
    • 2022
  • Newcastle disease (ND), infectious laryngotracheitis (ILT) and avian metapneumovirus (aMPV) can be similar making it critical to quickly differentiate them. Herein, we adapted pre-existing molecular-based diagnostic assays for NDV and ILTV, and developed new assays for aMPV A and B, for use under synchronized thermocycling conditions. All assays performed equivalently with linearity over a 5 log10 dynamic range, a reproducible (R2 > 0.99) limit of detection of ≥ 10 target copies, and amplification efficiencies between 86.8%-98.2%. Using biological specimens for NDV and ILTV showed 100% specificity. Identical amplification conditions will simplify procedures for detection in diagnostic laboratories.

Current Status of Magnetic Resonance Imaging in Patients with Malignant Uterine Neoplasms: A Review

  • Yu-Ting Huang;Yen-Ling Huang;Koon-Kwan Ng;Gigin Lin
    • Korean Journal of Radiology
    • /
    • 제20권1호
    • /
    • pp.18-33
    • /
    • 2019
  • In this study, we summarize the clinical role of magnetic resonance imaging (MRI) in the diagnosis of patients with malignant uterine neoplasms, including leiomyosarcoma, endometrial stromal sarcoma, adenosarcoma, uterine carcinosarcoma, and endometrial cancer, with emphasis on the challenges and disadvantages. MRI plays an essential role in patients with uterine malignancy, for the purpose of tumor detection, primary staging, and treatment planning. MRI has advanced in scope beyond the visualization of the many aspects of anatomical structures, including diffusion-weighted imaging, dynamic contrast enhancement-MRI, and magnetic resonance spectroscopy. Emerging technologies coupled with the use of artificial intelligence in MRI are expected to lead to progressive improvement in case management of malignant uterine neoplasms.

Solitary Necrotic Nodules of the Liver Mimicking Hepatic Metastasis: Report of Two Cases

  • Kwon-Ha Yoon;Ki Jung Yun;Jung-Min Lee;Chang Guhn Kim
    • Korean Journal of Radiology
    • /
    • 제1권3호
    • /
    • pp.165-168
    • /
    • 2000
  • We present two cases of solitary necrotic nodules of the liver which on radiologic images mimicked hepatic metastasis. Solitary necrotic nodule of the liver is a rare but benign entity which histopathologically consists of an outer fibrotic capsule with inflammatory cells and a central core of amorphous necrotic material. The lesion was seen on contrast-enhanced CT as an ovoid-shaped hypoattenuating nodule; on CT during hepatic arteriography as enhancing nodule; on intraoperative US as a target-appearing hypoechoic nodule; on T2WI as a hyperintensity nodule, and on dynamic MR as a subtle peripheral enhancing nodule. Although the radiologic features are not specific, solitary necrotic nodule of the liver should be included in the differential diagnosis of hepatic metastasis.

  • PDF

Portal cavernoma cholangiopathy: Update and recommendations on diagnosis and management

  • Ruchir Bhavsar;Amitabh Yadav;Samiran Nundy
    • 한국간담췌외과학회지
    • /
    • 제26권4호
    • /
    • pp.298-307
    • /
    • 2022
  • Portal cavernoma cholangiopathy is defined as an obstruction of the biliary system due to distended veins surrounding bile ducts that mainly occur in patients with extrahepatic portal venous obstruction. The periductal venous plexuses encircling the ducts can cause morphological changes which may or may not become symptomatic. Currently, non-invasive techniques such as ultrasonography, computed tomography, magnetic resonance cholangiopancreatography, and dynamic contrast enhanced magnetic resonance images are being used to diagnose this disorder. Only a few patients who have symptoms of biliary obstruction require drainage which might be accomplished using endoscopic stenting, decompression of the portal venous system usually via a lienorenal shunt, a difficult direct hepaticojejunostomy, and rarely a liver transplant.

간혈관종의 검사기법과 영상소견 (Examination Techniques and Imaging Findings of Hepatic Hemangioma)

  • 구창회;금종완;석지은;최동철;최윤호;한만석;전민철
    • 한국방사선학회논문지
    • /
    • 제17권3호
    • /
    • pp.375-384
    • /
    • 2023
  • 간혈관종은 우리 몸에서 흔하게 발생하는 간병변 중 하나이다. 대부분 간혈관종은 증상이 없고 크기도 작기에 병리학적 검사로는 발견하기 어렵다. 따라서 간혈관종의 초기 발견 및 진단을 하기 위해서는 방사선 진단은 필수이다. 본 연구는 간혈관종에 대한 방사선진단인 전산화단층촬영, 자기공명영상, 핵의학, 초음파 검사의 방법에 대하여 연구하였다. 전산화단층촬영에서는 조영제를 이용한 삼중시기 기법, 자기공명영상 검사에서는 T1, T2 강조영상, 조영제를 이용한 동적 자기공명영상, 초고속 자기공명 영상기법, 확산강조영상의 방법, 핵의학에선 99mTc 표지 적혈구를 사용한 혈액풀 스캔방법, 초음파에선 색조도플러의 방법에 대해 연구하였다. 대부분의 간혈관종은 양성종양이기에 간세포암 등과 같은 악성 종양과 혼동하지 않게 주의하여 불필요한 시술을 방지해야 한다. 그러므로 정확한 진단을 하기 위해서는 간혈관종의 영상소견을 정확히 숙지하여 검사를 시행하는 것이 중요하다.

초음파 검사에서 신장 결석의 검출 요인에 관한 연구 (The Study on the Factors for Detection of Renal Stone on Ultrasound)

  • 심현선;정홍량;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권1호
    • /
    • pp.1-6
    • /
    • 2006
  • I. 목 적: 신장 결석은 흔하며, 전형적으로 수집계에서 발생한다. 신동부는 수집계, 신혈관, 림프관, 지방, 섬유조직 등을 포함하고 있다. 초음파 장치 수신기의 신호 처리 과정에서 모든 큰 에코의 압축 때문에 일반적으로 신결석으로부터의 에코는 신동부의 정상적인 구조로부터 발생하는 큰 에코는 구별할 수 없다. 따라서 초음파 검사에서 후방음향음영이 동반하지 않은 크기가 작은 신장 결석 또는 결석의 화학적 구성 성분에 따라 결석 검출이 어려웠다. 본 연구의 목적은 다양한 스캔 변수에 따라 결석 후방에 발생하는 후방음향음영을 측정하여 신장결석 진단에 도움을 주고자 한다. II. 재료 및 방법: 결석을 수조 속 스폰지 위에 올려놓고 LOGIQ 400(U.S.A.)의 3.5 HMz와 7.5 HMz 탐촉자를 이용하였다. 첫째, 게인을 조절해가며 실험하였다. 둘째, 동적범위를 조절해가며 실험하였다. 셋째, 초점 영역을 조절해가며 실험하였다. 넷째, 깊이조절에 따른 저주파수와 고주파수의 에코 레벨을 측정하였다. III. 결 과: 1) 평균 에코 레벨은 총 게인이 10 dB일 때 98, 총 게인이 40 dB일 때 142로 나타났다. 결석의 후방음향음영은 총 게인이 낮을 때 뚜렷하게 나타났다. 2) 동적범위가 42 dB와 72 dB일 때 평균 에코 레벨이 각각 129와 101로 측정되었다. 신장 결석의 후방음향음영은 동적범위가 높을수록 뚜렷하게 나타났다. 3) 결석이 탐촉자의 초점영역에 위치할 때에 후방음영이 분명하게 나타났다. 4) 결석은 저주파수(3.5 MHz)보다 고주파수(7.5 MHz)에서 분명하게 나타났으며, 결석의 왜곡 없었다. IV. 결 론: 신장결석의 후방음향음영의 표현 총 게인, 동적범위, 초점영역, 주파수 등 다양한 기술적 요소들에 의존하며, 이러한 요소들은 신장결석 진단에 도움을 줄 것으로 생각된다.

  • PDF

풍력터빈 기어박스 내의 기어균열에 대한 모델 기반 고장진단 (Model-based Diagnosis for Crack in a Gear of Wind Turbine Gearbox)

  • 임상혁;박성훈;최주호
    • 한국전산구조공학회논문집
    • /
    • 제26권6호
    • /
    • pp.447-454
    • /
    • 2013
  • 모델기반 고장 진단법은 풍력발전기의 상태감지 시스템(Condition monitoring system)에 적용을 목적으로 변동 하중조건하에서 작동하는 기어박스내의 기어의 균열을 진단하기 위해 제시하였다. 두 개의 평기어(Spur gear)로 구성된 간단한 테스트 베드가 위의 접근방법을 검증하기 위해 구축되었고, 기어의 균열은 기어의 뿌리부분에 균열을 인가하여 묘사하였다. 축의 회전속도에 독립적인 타코미터를 기반으로 한 오더분석(Order analysis)을 균열크기 진단에 적용하였고, 테스트 베드의 작동을 시뮬레이션하기 위해 집중변수 모델(Lumped parameter dynamic model)이 사용되었다. 모델에서 균열과 밀접히 관련된 변수는 측정된 신호와 시뮬레이션된 신호 간의 차이를 최소화하는 최적화 기법으로 역추정하였다. 제시한 방법의 유효성을 보이기 위해, 미리 정의된 모델 변수로부터 생성된 시뮬레이션 신호를 테스트-베드로부터 측정된 신호로 가정하고, 제시한 방법을 사용하여 변수를 역추정하였다. 결과는 실제 값과 일치하였고, 이를 통해 알고리즘이 제대로 작동함을 알 수 있었다. 다음 연구에서는 실제 테스트 베드의 실제균열에 적용하고자 한다.