• Title/Summary/Keyword: Dynamic cone penetrometer test

Search Result 33, Processing Time 0.029 seconds

Soil resistance estimation using smart instrumented dynamic penetrometers

  • Geunwoo Park;Namsun Kim;Yong-Hoon Byun;Sang Yeob Kim;Jong-Sub Lee
    • Smart Structures and Systems
    • /
    • v.34 no.1
    • /
    • pp.63-72
    • /
    • 2024
  • In-situ penetration tests using dynamic penetrometers are widely used for estimating soil resistance. Additionally, these dynamic penetrometers have been instrumented to improve tests accuracy. This paper introduces smart instrumented dynamic penetrometers and discusses experimental studies for various cases. An energy monitoring module was developed to enhance the dynamic penetration tests. The standard penetration test (SPT) and instrumented dynamic cone penetrometer (IDCP) tests were conducted using the energy monitoring module. Dynamic responses obtained by the energy monitoring module were used to calculate the transferred energies into the rod head and tip to correct the evaluation of ground strength. In addition, a crosshole-type dynamic penetrometer (CDP) was developed to measure the penetration index and shear wave velocity simultaneously to estimate the strength and stiffness of ground. The results of this study indicate that smart instrumented dynamic penetrometers may be effectively used to characterize the strength and stiffness of ground.

The Ground Investigation Technique of Railway Using Pagani Cone Test (Pagani Cone Test를 이용한 철도노반 조사 기법 연구)

  • Cho, Eun-Kyung;Cho, Kook-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.6
    • /
    • pp.792-801
    • /
    • 2016
  • Standard Penetration Test (SPT) and Cone Penetration Test (CPT) are widely used in geotechnical investigation methods for railway roadbed. However, SPT can not be used on the Railway track, since the equipment may contact to the electric lines. However, a portable equipment can be used for geotechnical investigation without electrical hazard. Dynamic Cone Penetrometer (DCP) is one of representative portable equipments. A normal portable DCP has usually not enough driving energy and the rigidity of cone-rod, so it is impossible to investigate the required investigate penetration depth. In this study, The adaptability of Pagani cone test which is one of portable dynamic cone penetrometer is studied and compared with SPT-N data. As a result of this study, the proposed correlation factors between Pagani cone test and SPT-N values after corrections is 1.48 for sandy soil and 1.33 for clayey soil.

Characterization of railway substructure using a hybrid cone penetrometer

  • Byun, Yong-Hoon;Hong, Won-Taek;Lee, Jong-Sub
    • Smart Structures and Systems
    • /
    • v.15 no.4
    • /
    • pp.1085-1101
    • /
    • 2015
  • Changes in substructure conditions, such as ballast fouling and subgrade settlement may cause the railway quality deterioration, including the differential geometry of the rails. The objective of this study is to develop and apply a hybrid cone penetrometer (HCP) to characterize the railway substructure. The HCP consists of an outer rod and an inner mini cone, which can dynamically and statically penetrate the ballast and the subgrade, respectively. An accelerometer and four strain gauges are installed at the head of the outer rod and four strain gauges are attached at the tip of the inner mini cone. In the ballast, the outer rod provides a dynamic cone penetration index (DCPI) and the corrected DCPI (CDCPI) with the energy transferred into the rod head. Then, the inner mini cone is pushed to estimate the strength of the subgrade from the cone tip resistance. Laboratory application tests are performed on the specimen, which is prepared with gravel and sandy soil. In addition, the HCP is applied in the field and compared with the standard dynamic cone penetration test. The results from the laboratory and the field tests show that the cone tip resistance is inversely proportional to the CDCPI. Furthermore, in the subgrade, the HCP produces a high-resolution profile of the cone tip resistance and a profile of the CDCPI in the ballast. This study suggests that the dynamic and static penetration tests using the HCP may be useful for characterizing the railway substructure.

Bearing Capacity of Pavement Foundation by Waste Lime Material using the Dynamic Cone Pentrometer (동적 콘관입시험기를 이용한 폐석회 혼합 도로노반 성토체의 현장 지지력 평가)

  • Kim, Young-Seok;Hong, Seung-Seo;Bae, Gyu-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.927-935
    • /
    • 2011
  • In-situ California Bearing Ratio(CBR) test has been widely used for evaluating the subgrade condition in pavements. However, because the in-situ CBR test is expensive and takes time for operation, it is difficult to figure out the in-situ characteristics of subgrade strength in detail. For faster and economical operation, the Dynamic Cone Penetrometer(DCP) has been often utilized for estimating the subgrade strength in the field. The purpose of this paper is to determine the relationship between CBR value and DCP index of the embankment constructed with mixtures of soil and waste lime. Waste lime used in this study is producted as a by-product in the manufacturing process of making $Na_2CO_3$ from local chemical factory in Incheon. In this field measurement, the geotechnical tests such as field water content, field density, field CBR test, and dynamic cone penetration test were conducted.

Development of Dynamic Cone Penetration Tester Module for Slope Vulnerability Assessment and Correlation of Its Results with Standard Penetration Test Values (비탈면 취약도 평가를 위한 동적콘관입시험기 모듈개발과 표준관입시험값과의 상관관계 연구)

  • Chae, Hwi-Young;Kwon, Soon-dal
    • The Journal of Engineering Geology
    • /
    • v.31 no.4
    • /
    • pp.541-547
    • /
    • 2021
  • To assess the stability of a slope and the likelihood of its loss or collapse requires information about the ground, such as the composition of the stratum and its mechanical characteristics. This information is generally gathered through standard penetration testing (SPT) and cone penetration testing. SPT is not widely used due to problems with accessing slopes, most of which are steep and without ramps. A drop cone penetrometer, a portable device that can make up for these shortcomings, can be used in a limited way in some circumstances. Therefore, we developed a portable drilling machine and a small dynamic cone penetration test module that can easily access a slope site and perform SPT. The correlation of the developed system's results with those from SPT was analyzed. Analysis of the correlation between the energy shear rate passing to the load during the different test types established that the energy shear rate is reflected in the test result. The correlation between corrected dynamic cone penetration testing and corrected SPT was Nd' = 3.13 N'.

Estimation of Bearing Capacity of Subbase and Subgrade Using Pavement Dynamic Cone Penetrometer (포장동적관입시험기(PDCP)에 의한 보조기층 및 노상 지지력 측정)

  • Roo, Myung-Chan
    • International Journal of Highway Engineering
    • /
    • v.5 no.1 s.15
    • /
    • pp.35-45
    • /
    • 2003
  • This paper presents a theoretical approach for estimation of CBR-value of subbase course and subgrade using a portable pavement dynamic cone penetrometer(PDCP). The PDCP used in this paper was based on a design from South Africa and extensive studies by Kleyn(1982) and more recently by Liveneh and Ishai(1987) and Chua(1988). To date, California Bearing Ratio[CBR] value was studied mainly for application of pavement structural design. This study was initiated to develop a method of obtaining the in situ CBR-values of subbase and subgrade for the structural evaluation of pavements in the swift and inexpensive manner. PDCP tests were implemented at 20 different kinds of soil samples in the lab and test results were analysed by a theoretical approach introduced. The procedure presented provides acceptable and promising results.

  • PDF

Comparison of Field Bearing Capacity Tests to Evaluate the Field Application of Dynamic Cone Penetrometer Test (동적 콘관입 시험의 현장적용성 평가를 위한 현장 지지력시험 상호 비교 연구)

  • Kim, Boo-Il;Jeon, Sung-Il;Lee, Moon-Sup
    • International Journal of Highway Engineering
    • /
    • v.8 no.4 s.30
    • /
    • pp.75-85
    • /
    • 2006
  • Plate Bearing Test(PBT) and California Bearing Ratio Test(CBR) usually have been used to evaluate the bearing capacity of sub-layer in pavement system. However, these tests have shortcomings for which man powers and time are spent greatly. Many researchers proposed a simple Dynamic Cone Penetrometer Test(DCP) to evaluate the bearing capacity of sub-layers in pavement system. This study performed several field bearing capacity tests(DCP, PBT, CBR, FWD) to evaluate field performance of DCP on sub-base and subgrade at four test sections simultaneously. The results showed that DCPI, $M_{FWD}$, and $PBT_K_{30}$ are highly correlated, but CBR and other test are not. This study proposed the following regression models between FWD, DCP, and PBT: $$M_{FWD}=993.10\Big(\frac{1}{DCPI}\Big)+33.95\;R^2=0.77$$ $$M_{FWD}=3.7533K_{30}+23.085\;R^2=0.69$$

  • PDF

Application of The Dynamic Cone Penetrometer for Strength Estimation of Pavement Foundation (현장에서의 동적관입시험을 이용한 노상토의 지지력 평가연구)

  • An, Ji-Hwan;Yang, Sung-Lin;Park, Hee-Mun;Kwon, Su-Ahn
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.17-26
    • /
    • 2004
  • The in-situ California Bearing Ratio (CBR) test has been widely used for evaluating the subgrade condition in asphalt concrete pavements. However, because the in-situ CBR test is expensive and takes plenty of time for operation, it is very difficult to figure out the in-situ characteristics of subgrade strength in detail. For faster and economical operation, the Dynamic Cone Penetrometer (DCP) has been often utilized for estimating the subgrade strength in the field. The relationship between the CBR value and DCP index obtained from the DCP testing has been studied using the laboratory and in-situ testing by other foreign researchers. The objective of this study is to determine the relationship between in-situ CBR value and DCP index of the subgrade materials used in Korea. The DCP index for evaluating the strength of subgrade materials produced in Korea is presented in this paper. Research results propose the regression equation to explain the relationship between the CBR and DCP tests. The in-situ CBR values of subgrade materials range from 20 to 45% indicating the good and sound subgrade condition.

  • PDF

Use of Dynamic Cone Penetrometer and Light-Weight Deflectometer for Quality Control on Subgrade Base (토공사 다짐품질 관리를 위한 동적콘관입시험 및 소형충격재하시험의 활용에 관한 연구)

  • Baek, Sung-Ha;Cho, Jin-Woo;Kim, Namgyu;Kim, Jin-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.11
    • /
    • pp.55-67
    • /
    • 2022
  • This study applied the dynamic cone penetrometer test (DCPT) and light-weight deflectometer test (LWDT) to the quality control of subgrade base by performing DCPT, LWDT, and plate load test (PLT) at two earthwork sites. Although DCPT and LWDT were performed under the same conditions, the results showed significant variation with the test location. Because the measured value at the time of the initial blow, which varies depending on the test location, significantly influenced the test result. Thus, it was appropriate to ignore the first two blows as preliminary blows and use subsequent measurements as quality control indicators. In addition, DCPT, LWDT, and PLT results showed a high correlation under the same conditions. Especially regression analyses using averaged data for each experiment condition tended to yield significantly improved R2 values over individual point data sets. This indicates that average DCPT and LWDT values at various adjacent locations are better quality control indicators for subgrade bases than individual point values.