• Title/Summary/Keyword: Dynamic X-ray

Search Result 219, Processing Time 0.023 seconds

Local Contrast Enhancement of X-ray Chest Image using Adaptive Algorithm (적응 알고리즘에 의한 흉부 방사선 영상의 국부 대조도 개선)

  • 이세현;조병걸
    • Journal of Biomedical Engineering Research
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 1988
  • Because the amount of radiation emerging from the thorax behind the lungs is often literally thousands of times that exiting behind the mediastinum, the dynamic range of X-ray chest image is very large. In order to solve the dynamic range problem, we propose a signal adaptive algorithm which enhances the local contrast and contracts the enhancement of quantum noise by local mean/valiance estimator.

  • PDF

The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition (3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구)

  • Jeong, Chan-Woong;Jun, Kyu-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.4
    • /
    • pp.370-374
    • /
    • 2009
  • In this paper, we presents a new cone beam computerized tomography (CB CT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time.

Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

  • Akinori Hata;Yoshitake Yamada;Rie Tanaka;Mizuki Nishino;Tomoyuki Hida;Takuya Hino;Masako Ueyama;Masahiro Yanagawa;Takeshi Kamitani;Atsuko Kurosaki;Shigeru Sanada;Masahiro Jinzaki;Kousei Ishigami;Noriyuki Tomiyama;Hiroshi Honda;Shoji Kudoh;Hiroto Hatabu
    • Korean Journal of Radiology
    • /
    • v.22 no.4
    • /
    • pp.634-651
    • /
    • 2021
  • Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.

X-ray and Plasma Process Induced Damages to PLZT Capacitor Characteristics for DRAM Applications

  • Kim, Jiyoung
    • The Korean Journal of Ceramics
    • /
    • v.3 no.3
    • /
    • pp.213-217
    • /
    • 1997
  • In this paper, the imparct of X-ray and plasma process-induced-damages to La doped Lead Zirconate Titanate (PLZT, (Pb1-xLa)(Zr0.5Ti0.5)O3) capacitor characteristics have been investigated from the viewpoint of gigabit scale dynamic random access memory (DRAM) applications. Plamsa damage causes asymmetric degradation on hysteresis characteristics of PLZT films. On the other hand, X-ray damage results in a symmetrical reduction of charge storage densities (Qc's) for both polarities. As La concentration increases in the films, the radiation hardness of PLZT films on X-ray and plasma exposures is improved. It is observed that the damaged devices are fully recovered by thermal annealing under oxygen ambient.

  • PDF

Experimental Study on the Dynamic Damage Mechanism of Rocks Under Different Impact Loadings (단계적 충격하중에 의한 암석의 동적손상메커니즘에 관한 실험적 연구)

  • Cho, Sang-Ho;Jo, Seul-Ki;Ki, Seung-Kon;Park, Chan;Kaneko, Katsuhiko
    • Tunnel and Underground Space
    • /
    • v.19 no.6
    • /
    • pp.545-557
    • /
    • 2009
  • In order to investigate dynamic damage mechanism of brittle materials, Split Hopkinson Pressure Bar (SHPB) have been adapted to apply different impact levels to rocks in South Korea. High resolution X-ray Computed Tomography (CT) was used to estimate the damage in tested rock samples nondestructively. The cracks which are parallel to the loading axis are visible on the contact surface with the incident bar under lower level of impact. The surface cracks disappeared with increment of impact level due to confined effect between the incident bar and sample, while axial splitting are happened near the outer surface.

Settling time of dental x-ray tube head after positioning (치과용 X-선 관구의 조정시간)

  • Yoon Suk-Ja;Kang Byung-Cheol;Wang Se-Myung;Koh Chang-Sung
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

RESULTS FROM THE YOHKOH SATELLITE

  • WATANABE TETSUYA
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.291-294
    • /
    • 1996
  • The .Japanese sun observing satellite, Yohkoh, has been operational for five years and her scientific instruments are still in good condition. They have revealed ample of evidences that solar flares were triggered by magnetic reconnection, which was, for the first time, clearly indicated to take place in the solar corona. Cusp structures in soft X-rays and a new type of hard X-ray sources at the top of flaring loops have strongly supported the scenario originally proposed by C-S-H-KP. Nonthermal energy input in hard X-rays and thermal energy estimated from soft X-rays are fundamentally consistent with the interpretation of thick-target and chromospheric-evaporation models (Neupert effect). X-ray jets, another discovery of Yohkoh, were also associated with magnetic reconnection, as a result of the interaction of emerging fluxes with pre-existing coronal loops. Temperature structures of active regions, quiet sun, and coronal holes had very dynamic differential-emission-measure (DEM) distributions and high-temperature tails of DEM were considered to come from the contribution of flare-like activity.

  • PDF

The study for electric readout of X-ray signal using MOSFET (MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구)

  • Park, S.K.;Kang, Y.S.;Seo, J.H.;Park, J.K.;Nam, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images (X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법)

  • Kim, Hyunggue;Jung, Joongeun;Lee, Jihyun;Park, Joonhyuk;Seo, Jisu;Kim, Hojoon
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.4
    • /
    • pp.171-178
    • /
    • 2019
  • The use of anti-scatter grids in radiographic imaging has the advantage of preventing the image distortion caused by scattered radiation. However, it carries the side effect of leaving artifacts in the X-ray image. In this paper, we propose a grid line suppression technique using discrete cosine transform(DCT). In X-ray images, the grid lines have different characteristics depending on the shape of the object and the area of the image. To solve this problem, we adopt the DCT transform based on a dynamic segmentation, and propose a filter transfer function for each individual segment. An algorithm for detecting the band of grid lines in frequency domain and a band stop filter(BSF) with a filter transfer function of a combination of Kaiser window and Butterworth filter have been proposed. To solve the blocking effects, we present a method to determine the pixel values using multiple structured images. The validity of the proposed theory has been evaluated from the experimental results using 140 X-ray images.