• 제목/요약/키워드: Dynamic X-ray

검색결과 219건 처리시간 0.025초

적응 알고리즘에 의한 흉부 방사선 영상의 국부 대조도 개선 (Local Contrast Enhancement of X-ray Chest Image using Adaptive Algorithm)

  • 이세현;조병걸
    • 대한의용생체공학회:의공학회지
    • /
    • 제9권1호
    • /
    • pp.61-66
    • /
    • 1988
  • Because the amount of radiation emerging from the thorax behind the lungs is often literally thousands of times that exiting behind the mediastinum, the dynamic range of X-ray chest image is very large. In order to solve the dynamic range problem, we propose a signal adaptive algorithm which enhances the local contrast and contracts the enhancement of quantum noise by local mean/valiance estimator.

  • PDF

3D 동영상획득을 위한 Cone-Beam 형 X-Ray CT 시스템 구현에 관한 연구 (The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition)

  • 정찬웅;전계석
    • 한국음향학회지
    • /
    • 제28권4호
    • /
    • pp.370-374
    • /
    • 2009
  • 본 논문에서는 3차원 동영상을 구현하기 위하여 인체에 유해한 방사능 피폭량이 부챗살 형태의 Fan Beam 보다 상대적으로 적은 원추형 Cone Beam CT 시스템을 설계하였다. 설계된 시스템은 X-ray가 조사된 각도에서 획득한 데이터를 영상처리부로 전송하고 영상을 구성하는 계산 속도를 빠르게 하기 위하여 초월함수가 보다 적은 3단계 회전 행렬을 이용하여 3차원 영상을 구현하는 회전 기반법을 사용하였다. 본 연구에서는 3차원 영상을 구성하는 시간단축을 통해 초당 3~5장의 영상을 얻음으로써 3차원 동영상을 실시간으로 구현하였다.

Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

  • Akinori Hata;Yoshitake Yamada;Rie Tanaka;Mizuki Nishino;Tomoyuki Hida;Takuya Hino;Masako Ueyama;Masahiro Yanagawa;Takeshi Kamitani;Atsuko Kurosaki;Shigeru Sanada;Masahiro Jinzaki;Kousei Ishigami;Noriyuki Tomiyama;Hiroshi Honda;Shoji Kudoh;Hiroto Hatabu
    • Korean Journal of Radiology
    • /
    • 제22권4호
    • /
    • pp.634-651
    • /
    • 2021
  • Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.

X-ray and Plasma Process Induced Damages to PLZT Capacitor Characteristics for DRAM Applications

  • Kim, Jiyoung
    • The Korean Journal of Ceramics
    • /
    • 제3권3호
    • /
    • pp.213-217
    • /
    • 1997
  • In this paper, the imparct of X-ray and plasma process-induced-damages to La doped Lead Zirconate Titanate (PLZT, (Pb1-xLa)(Zr0.5Ti0.5)O3) capacitor characteristics have been investigated from the viewpoint of gigabit scale dynamic random access memory (DRAM) applications. Plamsa damage causes asymmetric degradation on hysteresis characteristics of PLZT films. On the other hand, X-ray damage results in a symmetrical reduction of charge storage densities (Qc's) for both polarities. As La concentration increases in the films, the radiation hardness of PLZT films on X-ray and plasma exposures is improved. It is observed that the damaged devices are fully recovered by thermal annealing under oxygen ambient.

  • PDF

단계적 충격하중에 의한 암석의 동적손상메커니즘에 관한 실험적 연구 (Experimental Study on the Dynamic Damage Mechanism of Rocks Under Different Impact Loadings)

  • 조상호;조슬기;김승곤;박찬;금자승비고
    • 터널과지하공간
    • /
    • 제19권6호
    • /
    • pp.545-557
    • /
    • 2009
  • 단계별 손상에 따른 취성재료의 동적손상메커니즘을 파악하고자 국내암석을 대상으로 스플릿 홉킨슨 압력바 시스템을 이용한 단계적 충격하중실험을 수행하였다. 실험시료 내 동적손상을 평가하기 위하여 고해상도 X-ray 단층촬영 시스템을 적용하였다. 그 결과 낮은 충격하중에서는 시료 내 전반적으로 축방향 균열 즉 수직균열이 발생하지만, 충격속도가 증가함에 따라 시료와 입사바 또는 전달바와의 접촉면에 구속효과가 발생하여 입사바와의 접촉면 중심부에 균열이 사라지는 경향을 보였다. 그러나 구속력을 적게 받는 시료의 원주표면 부근에서는 박리균열을 보였다.

치과용 X-선 관구의 조정시간 (Settling time of dental x-ray tube head after positioning)

  • 윤숙자;강병철;왕세명;고창성
    • Imaging Science in Dentistry
    • /
    • 제32권3호
    • /
    • pp.159-165
    • /
    • 2002
  • Purpose: The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. Materials and Methods: An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X -axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. Results : The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 1 I seconds for the mobile-types. Conclusion: Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after x-ray tube head positioning for better radiographic resolution.

  • PDF

RESULTS FROM THE YOHKOH SATELLITE

  • WATANABE TETSUYA
    • 천문학회지
    • /
    • 제29권spc1호
    • /
    • pp.291-294
    • /
    • 1996
  • The .Japanese sun observing satellite, Yohkoh, has been operational for five years and her scientific instruments are still in good condition. They have revealed ample of evidences that solar flares were triggered by magnetic reconnection, which was, for the first time, clearly indicated to take place in the solar corona. Cusp structures in soft X-rays and a new type of hard X-ray sources at the top of flaring loops have strongly supported the scenario originally proposed by C-S-H-KP. Nonthermal energy input in hard X-rays and thermal energy estimated from soft X-rays are fundamentally consistent with the interpretation of thick-target and chromospheric-evaporation models (Neupert effect). X-ray jets, another discovery of Yohkoh, were also associated with magnetic reconnection, as a result of the interaction of emerging fluxes with pre-existing coronal loops. Temperature structures of active regions, quiet sun, and coronal holes had very dynamic differential-emission-measure (DEM) distributions and high-temperature tails of DEM were considered to come from the contribution of flare-like activity.

  • PDF

MOSFET를 이용한 X선 신호의 전기적 획득에 관한 연구 (The study for electric readout of X-ray signal using MOSFET)

  • 박성광;강영수;서지현;박지군;남상희
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.295-296
    • /
    • 1998
  • With xeroradiography appearance, DR (Digital Radiography) system have been studying for X-ray detection using photoreceptor. Also detection method for receptor charge change have been developing variably. We use photoreceptor material of a-Se(Amorphous Selenium) with high DQE, high SNR(Signal to Noise Ratio) and high transformation efficiency of X-ray signals into electrical signals. After a-Se receptor is uniformly charged by using Arc discharge, X-ray is exposed. Then a-Se receptor produce subtle charge variation and MOSFET detect charge variations. The detected signal pass A/D converter and signal processing by PC. As results, the initial voltage is 8V. It has wide dynamic range needed digital radiography system. In this study, we obtained data with changing kVp(tube potential voltage) and fixed 8mAs(tube current by exposure time) in X-ray system. However MOSFET detector for X-ray signal is not tested X-ray mAs variations. But if MOSFET detector is tested X-ray mAs variation and exactly calibrated multichannel is made and noise-reduction is done, suitable DR system readout method will be done.

  • PDF

X-ray 영상에서 그리드 아티팩트 개선을 위한 동적 분할 기반 DCT 기법 (A Dynamically Segmented DCT Technique for Grid Artifact Suppression in X-ray Images)

  • 김형규;정중은;이지현;박준혁;서지수;김호준
    • 정보처리학회논문지:소프트웨어 및 데이터공학
    • /
    • 제8권4호
    • /
    • pp.171-178
    • /
    • 2019
  • 방사선 진단에서 산란선 보정 그리드의 사용은 굴절되는 신호에 의한 영상의 왜곡을 방지할 수 있는 장점이 있는 반면, X-ray 영상에서 그리드 아티팩트를 발생시키는 부작용을 수반한다. 본 논문에서는 이산코사인변환(DCT: discrete cosine transform)을 사용하여, 그리드 라인을 개선하는 기법을 제안한다. X-ray 영상에서 그리드 라인은 피사체의 형태와 영상의 영역에 따라 서로 다른 특성을 보인다. 이러한 점을 해결하기 위하여 동적 분할 구조를 기반으로 DCT 변환을 적용하고, 개별 분할별로 적합한 필터전달함수를 설계하였다. 세부적으로 주파수 영역 데이터에 대하여 그리드 라인의 대역을 검출하는 알고리즘을 제안하였으며, 필터전달함수로 Kaiser 윈도우와 Butterworth 필터를 조합한 형태의 밴드스톱필터(BSF: band stop filter)를 구현하였다. 또한 블로킹 현상을 개선하기 위하여 다중구조의 영상으로부터 픽셀값을 결정하는 방법론을 제시하였다. 총 140개의 실제 X-ray 영상을 사용한 실험결과로부터 제안된 이론의 타당성을 실험적으로 평가하였다.