• Title/Summary/Keyword: Dynamic RCS

Search Result 24, Processing Time 0.027 seconds

Thermal Cycling Screening Criteria to RCS Branch Lines in Domestic Nuclear Power Plant (국내 원전 RCS 분기배관에 대한 열피로 선정기준)

  • Park, Jeong Soon;Choi, Young Hwan;Lim, Kuk Hee;Kim, Sun Hye
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.2
    • /
    • pp.54-60
    • /
    • 2010
  • Piping failures due to thermal fatigue have been widely reported in normally stagnant non-isolable reactor coolant branch lines. Since the thermal fatigue due to thermal stratification was not considered in the piping fatigue design in old NPPs, it is important to evaluate the effect of thermal stratification on the integrity of branch lines. In this study, geometrical screening criteria for Up-horizontal branch lines in MRP-132 were applied to SI(Safety Injection) lines of KSNP 2-loop and WH 3-loop. Some computational fluid dynamic(CFD) analyses on the Reactor Coolant System(RCS) branch lines were also performed to develop the regulatory guidelines for screening criteria. As a result of applying MRP-132 screening criteria, KSNP 2-loop and WH 3-loop SI lines are determined to need further detailed evaluation. Results of CFD analyses show that both valve isolation and amount of leakage through valve can be used as technical bases for the screening criteria on the thermal fatigue analysis.

  • PDF

TCP Accelerator for DVB-RCS SATCOM Dynamic Bandwidth Environment with HAIPE

  • Kronewitter, F. Dell;Ryu, Bo;Zhang, Zhensheng;Ma, Liangping
    • Journal of Communications and Networks
    • /
    • v.13 no.5
    • /
    • pp.518-524
    • /
    • 2011
  • A high assurance IP encryption (HAIPE) compliant protocol accelerator is proposed for military networks consisting of red (or classified) networks and black (or unclassified) networks. The boundary between red and black sides is assumed to be protected via a HAIPE device. However, the IP layer encryption introduces challenges for bandwidth on demand satellite communication. The problems experienced by transmission control protocol (TCP) over satellites are well understood: While standard modems (on the black side) employ TCP performance enhancing proxy (PEP) which has been shown to work well, the HAIPE encryption of TCP headers renders the onboard modem's PEP ineffective. This is attributed to the fact that under the bandwidth-on-demand environment, PEP must use traditional TCP mechanisms such as slow start to probe for the available bandwidth of the link (which eliminates the usefulness of the PEP). Most implementations recommend disabling the PEP when a HAIPE device is used. In this paper, we propose a novel solution, namely broadband HAIPE-embeddable satellite communications terminal (BHeST), which utilizes dynamic network performance enhancement algorithms for high latency bandwidth-on-demand satellite links protected by HAIPE. By moving the PEP into the red network and exploiting the explicit congestion notification bypass mechanism allowed by the latest HAIPE standard, we have been able to regain PEP's desired network enhancement that was lost due to HAIPE encryption (even though the idea of deploying PEP at the modem side is not new). Our BHeST solution employs direct video broadcast-return channel service (DVB-RCS), an open standard as a means of providing bandwidth-on-demand satellite links. Another issue we address is the estimation of current satellite bandwidth allocated to a remote terminal which is not available in DVBRCS. Simulation results show that the improvement of our solution over FIX PEP is significant and could reach up to 100%. The improvement over the original TCP is even more (up to 500% for certain configurations).

Improving Efficiency of Timeslot Assignment for Non-realtime Data in a DVB-RCS Return Link: Modeling and Algorithm

  • Lee, Ki-Dong;Cho, Yong-Hoon;Lee, Ho-Jin;Oh, Deock-Gil
    • ETRI Journal
    • /
    • v.25 no.4
    • /
    • pp.211-218
    • /
    • 2003
  • This paper presents a dynamic resource allocation algorithm with multi-frequency time-division multiple access for the return link of interactive satellite multimedia networks such as digital video broadcasting return channel via satellite systems. The proposed timeslot assignment algorithm, called the very efficient dynamic timeslot assignment (VEDTA) algorithm, gives an optimal assignment plan within a very short period. The optimality and computational efficiency of this algorithm demonstrate that it will be useful in field applications.

  • PDF

Assessment of seismic design coefficients for composite special moment frames with reinforced concrete columns and steel beams: Evaluation of code recommendations

  • Elmira Tavasoli Yousef Abadi;Mohammad T. Kazemi
    • Steel and Composite Structures
    • /
    • v.50 no.6
    • /
    • pp.643-658
    • /
    • 2024
  • The main aim of this study is to quantify the code seismic design coefficients of the RCS system, which consisted of reinforced concrete columns and steel beams, based on the FEMA P-695 methodology. The underlying intention is to evaluate the seismic performance of the RCS system at the system level rather than the connection level. A set of 24 archetype buildings with a various number of stories, beam span lengths, gravity load levels, and seismic load levels are selected and designed based on the prevailing code requirements. Nonlinear analytical models are developed and validated by experimental tests. The pushover and response history dynamic analyses are conducted to evaluate the required data in the performance quantification process. The results show that the design coefficients suggested by the code are acceptable. However, the level of conservatism is very high. Thus, it is possible to use a larger R-factor in the design process or make some relaxations in the design requirements related to this structural system.

The Development of the Multi-function Radar Signal Processor Having the High Spurious Free Dynamic Range (불요신호 특성이 우수한 다기능레이더 신호처리기 개발)

  • Lee, Hee-Young
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.140-146
    • /
    • 2010
  • The multi-function radar can detect and track the low RCS targets. For this purpose the multi-function radar uses the pulse train waveform. because this waveform has high dynamic range and good SNR(Signal to Noise Ratio). But the spurious signals can also be detected by processing the pulse train waveform. Thus the multi-function radar signal processor must have the high SFDR(Spurious Free Dynamic Range). This paper describes the development of the multi-function radar signal processor having the high SFDR.

A New Method for Assessing Dynamic Reliability for the Mid-loop Operation (원전의 부분충수운전에 대한 동적 신뢰도평가)

  • 제무성;박군철
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.52-59
    • /
    • 1996
  • This paper presents a new approach for assessing the dynamic reliability in a complex system such as a nuclear power plant. The method is applied to a dynamic analysis of the potential accident sequences which may occur during mid-loop operation. Mid-loop operation is defined as an operation to make RCS water level below the top of the flow area of the hot legs at the junction with the reactor vessel for repairs and maintenance of steam generators and reactor coolant pumps for a specific time. The Idea behind this approach consists of both the use of the concept of the performance achievement/requirement correlation and of a dynamic event tree generation method. The assessment of the system reliability depends on the determination of both the required performance distribution and the achieved performance distribution. The quantified correlation between requirement and achievement represents a comparison between two competing variables. It is demonstrated that this method is easily applicable and flexible in that it can be applied to any kind of dynamic reliability problem.

  • PDF

An Enhanced Harmonic Voltage Compensator for General Loads in Stand-alone Distributed Generation Systems

  • Trinh, Quoc-Nam;Lee, Hong-Hee;Chun, Tae-Won
    • Journal of Power Electronics
    • /
    • v.13 no.6
    • /
    • pp.1070-1079
    • /
    • 2013
  • This paper develops an enhanced harmonic voltage compensator which is implemented with the aid of two repetitive controllers (RCs) in order to improve the output voltage performance of stand-alone distributed generation (DG) systems. The proposed harmonic voltage compensator is able to maintain the DG output voltage sinusoidal regardless of the use of nonlinear and/or unbalanced loads in the load side. In addition, it can offer good steady-state performance under various types of loads and a very fast dynamic response under load variations to overcome the slow dynamic response issue of the traditional RC. The feasibility of the proposed control strategy is verified through simulations and experiments.

Analysis of Micro-Doppler Signatures from Rotating Propellers Using Modified HHT Method (수정된 HHT 기법을 이용하여 회전하는 프로펠러 날개에 의한 마이크로 도플러 신호의 해석)

  • Park, Ji-Hoon;Choi, Ik-Hwan;Myung, Noh-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.9
    • /
    • pp.1100-1106
    • /
    • 2012
  • This paper has presented the analysis of the micro-Doppler signatures scattered from the blades of the rotating propeller using the modified HHT method, one of the joint time-frequency analysis methods. The field scattered from the blade edge of the propeller was calculated using equivalent current method(ECM). After the acquisition of the scattered field data in the time domain, the modified HHT method was applied to analyze the micro-Doppler signature. The analysis results showed not only a good agreement with the realistic dynamic characteristic of the blade but also sinusoidally varing characteristics of the micro-Doppler signatures generated from rotating objects. It could be concluded that the joint time-frequency analysis via the modified HHT provided the discriminative characteristics for recognizing a small aircraft target with small RCS value.

Implementation of Inter-vehicle Communication System and Experiments of Longitudinal Vehicle Platoon Control via a Testbed

  • Kim, Tae-Min;Choi, Jae-Weon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.711-716
    • /
    • 2003
  • This study considers the implementation issues of the inter-vehicle communication system for the vehicle platoon experiments via a testbed. The testbed, which consists of three scale vehicles and one RCS(remote control station), is developed as a tool for functions evaluation between simulation studies and full-sized vehicle researches in the previous study. The cooperative communication of the vehicle-to-vehicle or the vehicle-to-roadside plays a key role for keeping the relative spacing of vehicles small in a vehicle platoon. The static platoon control, where the number of vehicles remains constant, is sufficient for the information to be transmitted in the suitably fixed interval, while the dynamic platoon control such as merge or split requires more flexible network architecture for the dynamical coordination of the communication sequence. In this study, the wireless communication device and the reliable protocol of the flexible network architecture are implemented for our testbed, using the low-cost, ISM band transceiver and the 8-bit microcontroller.

  • PDF

A Numerical Study on the IRWST Pool Temperature Distributionin in APR1400 (APR1400 IRWST Pool 온도분포 해석)

  • Kang, Hyung-Seok;Bae, Yoon-Y.;Park, Jong-Kyung
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.813-820
    • /
    • 2001
  • The Safety depressurization System(SDS) of KNGR prevents RCS from overpressurization by discharging high pressure and temperature coolant through the I-sparger into the IRWST during an accident. If IRWST water temperature rise locally, around the sparger, beyond $200_{\circ}$2000 F by the discharged coolant, unstable steam condensation can cause large pressure load on the IRWST wall. To investigate whether this condition can be avoided for the design basis event IOPOSRV(Inadvertent Opening of one Pilot Operated Safety Relief Valve), the flow and temperature distribution of water in the IRWST is calculated by using CFX 4.3 computational fluid dynamic code. According to the results, since pool water temperature does not exceeds temperature limit within 50 seconds after the opening of one POSRV, it can be assured that the integrity of IRWST wall is maintained.

  • PDF