• Title/Summary/Keyword: Dynamic Operation Test

Search Result 307, Processing Time 0.03 seconds

Cause Analysis for the Wall Thinning and Leakage of a Small Bore Piping Downstream of an Orifice (주증기계통 오리피스 후단 소구경 배관의 감육 및 누설 발생)

  • Hwang, Kyeong Mo
    • Corrosion Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.227-232
    • /
    • 2013
  • A number of components installed in the secondary system of nuclear power plants are exposed to aging mechanisms such as FAC (Flow-Accelerated Corrosion), Cavitation, Flashing, and LDIE (Liquid Droplet Impingement Erosion). Those aging mechanisms can lead to thinning of the components. In April 2013, one (1) inch small bore piping branched from the main steam line experienced leakage resulting from wall thinning in a 1,000 MWe Korean PWR nuclear power plant. During the normal operation, extracted steam from the main steam line goes to condenser through the small bore piping. The leak occurred in the downstream of an orifice. A control valve with vertical flow path was placed on in front of the orifice. This paper deals with UT (Ultrasonic Test) thickness data, SEM images, and numerical simulation results in order to analyze the extent of damage and the cause of leakage in the small bore piping. As a result, it is concluded that the main cause of the small bore pipe wall thinning is liquid droplet impingement erosion. Moreover, it is observed that the leak occurred at the reattachment point of the vortex flow in the downstream side of the orifice.

Combustion Stability for Utility Gas Turbines : Development of a Real-Time Assessment Software (발전용 가스터빈의 실시간 연소안정성 평가 소프트웨어 개발)

  • In, Byeung Goo;Song, Won Joon;Cha, Dong Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.306-315
    • /
    • 2017
  • This study introduces a software for real-time assessment of combustion stability for utility gas turbines. The software was written with LabView, and implemented the time-domain kurtosis as a parameter to proactively access the instantaneous combustion stability during operation of the industrial gas turbine. The simple time-domain assessment algorithm incorporated in the software is advantageous over conventional frequency-domain signal processing of dynamic pressure signal since it reduces the computational cost, thereby making the algorithm more appropriate for real-time monitoring of combustion stability. Benchmark data obtained from a model gas turbine combustor were used for the reproducibility test of the software. The assessment obtained from the software agreed well with previously published results, indicating that incorporation of the software could enhance the performance of systems monitoring the combustion stability for gas turbines during power generation.

Design and Control of Levitation and Guidance Systems for a Semi-High-Speed Maglev Train

  • Kim, Min;Jeong, Jae-Hoon;Lim, Jaewon;Kim, Chang-Hyun;Won, Mooncheol
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.117-125
    • /
    • 2017
  • Research on Maglev (Magnetic Levitation) train is currently being conducted in Korea, concerning Urban Transit (110 km/h of maximum speed), semi-high-speed (200 km/h of maximum speed), and high-speed (550 km/h of maximum speed) trains. This paper presents a research study on the levitation and guidance systems for the Korean semi-high-speed maglev train. A levitation electromagnet was designed, and the need for a separate guidance system was analyzed. A guidance electromagnet to control the lateral displacement of the train and ensure its stable operation was then also designed, and its characteristics were analyzed. The dynamic performance of the designed levitation and guidance electromagnets was modeled and analyzed, using a linearized modeling of the system equations of motion. Lastly, a test setup was prepared, including manufactured prototypes of the designed system, and the validity of the design was verified and examined with performance evaluation tests.

A new model for curbing filtrate loss in dynamic application of nano-treated aqueous mud systems

  • Okoro, Emmanuel E.;Oladejo, Bukola R.;Sanni, Samuel E.;Obomanu, Tamunotonjo;Ibe, Amarachukwu A.;Orodu, Oyinkepreye D.;Olawole, Olukunle C.
    • Advances in nano research
    • /
    • v.9 no.1
    • /
    • pp.59-67
    • /
    • 2020
  • Filter cake formation during rotary drilling operation is an unavoidable scenario, hence there is need for constant improvement in the approaches used in monitoring the cake thickness growth in order to prevent drill-string sticking. This study proposes an improved model that predicts the growth of mud cake thickness overtime with the consideration of the addition of nanoparticles in the formulated drilling fluid system. Ferric oxide, titanium dioxide and copper oxide nanoparticles were used in varying amounts (2 g, 4 g and 6 g), and filtration data were obtained from the HPHT filtration test. The filter cakes formed were further analyzed with scanning electron microscope to obtain the morphological characteristics. The data obtained was used to validate the new filtrate loss model. This model specifically presents the concept of time variation in filter cake formation as against the previous works of constant and definite time. Regression coefficient which is a statistical measure was used to validate the new model and the predicted results were compared with the API model. The new model showed R2 values of 99.9%, and the predictions from the proposed filtration model can be said to be more closely related to the experimental data than that predicted from the API model from the SSE and RMSE results.

EMTP Simulation of 345kV Substation in Large Network Using Newly Developed Thevenin Equivalent Network (345kv 미금 변전소 외부 계통의 등가축약 기법을 이용한 EMTP 모델링에 관한 연구)

  • Kwon, Ki-Jin;Jeong, Ki-Seok;Seo, Gyu-Seok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.14 no.3
    • /
    • pp.121-125
    • /
    • 2011
  • EMTP-RV is the very powerful program to analyze the dynamic operation of the power system. To use this package in the large complex power system, it is very important to simplify the power system to simple equivalent network. In our study the 100 MVA STATCOM is placed at 345kV "MIGUM" which is the one of the 345kV substations of the Korean Electric Power System that is consist of more than 1000-bus. MIGUM substation is connected with 7 separated transmission lines to main Korean Electric power system. We developed a new method to simplify the network except the substation that we want to analysis. The power system outside the 345kV substation is modeled into the equivalent network. The loop network outside the substation can be modeled to simplified Thevenin equivalent network. The proposed method is applied to IEEE-14 Reliability Test System and the results shows the effectiveness of the method.

Evaluation of a Self-Adaptive Voltage Control Scheme for Low-Power FPGAs

  • Ishihara, Shota;Xia, Zhengfan;Hariyama, Masanori;Kameyama, Michitaka
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.10 no.3
    • /
    • pp.165-175
    • /
    • 2010
  • This paper presents a fine-grain supply-voltage-control scheme for low-power FPGAs. The proposed supply-voltage-control scheme detects the critical path in real time with small overheads by exploiting features of asynchronous architectures. In an FPGA based on the proposed supply-voltage-control scheme, logic blocks on the sub-critical path are autonomously switched to a lower supply voltage to reduce the power consumption without system performance degradation. Moreover, in order to reduce the overheads of level shifters used at the power domain interface, a look-up-table without level shifters is employed. Because of the small overheads of the proposed supply-voltage-control scheme and the power domain interface, the granularity size of the power domain in the proposed FPGA is as fine as a single four-input logic block. The proposed FPGA is fabricated using the e-Shuttle 65 nm CMOS process. Correct operation of the proposed FPGA on the test chip is confirmed.

Study on the Dynamic Synchronizing Control of An Islanded Microgrid (독립운전 마이크로그리드의 능동형 동기 투입 제어에 관한 연구)

  • Cho, Chang-Hee;Jeon, Jin-Hong;Kim, Jong-Yul;Kwon, Soon-Man;Kim, Sung-Shin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1112-1121
    • /
    • 2011
  • A microgrid is an aggregation of multiple distributed generators (DGs) such as renewable energy sources, conventional generators, and energy storage systems that provide both electric power and thermal energy. Generally, a microgrid operates in parallel with the main grid. However, there are cases in which a microgrid operates in islanded mode, or in a disconnected state. Islanded microgrid can change its operational mode to grid-connected operation by reconnection to the grid, which is referred to as synchronization. Generally, a single machine simply synchronizes with the grid using a synchronizer. However, the synchronization of microgrid that operate with multiple DGs and loads cannot be controlled by a traditional synchronizer, but needs to control multiple generators and energy storage systems in a coordinated way. This is not a simple job, considering that a microgrid consists of various power electronics-based DGs as well as alternator-based generators that produce power together. This paper introduces the results of research examining an active synchronizing control system that consists of the network-based coordinated control of multiple DGs. Consequently, it provides the microgrid with a deterministic and reliable reconnection to the grid. The proposed method is verified by using the test cases with the experimental setup of a microgrid pilot plant.

Development of Common Database for the Application Programs of Distribution Management System (배전운영시스템용 응용 프로그램을 위한 공통 데이터베이스 구축)

  • Yun, Sang-Yun;Chu, Chul-Min;Kwan, Seong-Chul;Lee, Hak-Ju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1199-1208
    • /
    • 2013
  • In recent years, the development of application programs for distribution system analysis and control has been essential part for distribution management system (DMS). In this paper, we propose the common database for application programs of distribution management system. The proposed database model has several characteristics as followings. First, the proposed database model is designed for the common use of almost the whole distribution application software. The static equipment model and dynamic type tables are mixed and the parallel table structure is applied. Second, the linked list structure of database are used for the fast processing of applications. The database model includes the hierarchy and non-hierarchy distribution system structure. Third, the reduction method of distribution database is applied. For this, we present the network reduction rules. The basic concept of reduction rules are the electrical unification of successive line section which has not lateral branches and the removal of simple lateral branches which has no devices and other laterals. Proposed database model is tested for the Jeju system of Korea Electric Power Corporation (KEPCO). Through the test, we verified that the proposed database structure can be effectively used to accomplish the distribution system operation.

Dynamics Analysis and experiment verification of seatbelt system with pre-tensioner considering connection action of a human body (인체의 연계작용을 고려한 프리텐셔너를 가진 시트벨트 시스템의 동역학 해석 및 실험적 검증)

  • Kuk, Min-Gu;Tak, Tea-Oh;Park, Jae-Soon;Kim, Dae-Hee
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1009-1014
    • /
    • 2007
  • To improve passenger safety, seatbelt systems with pre-tensioner that tightens seatbelt webbing using explosives just before collision are widely adopted. Even though seatbelt must not be unlatched without passenger's operation, release of a buckle due to explosion of pre-tensioner takes place in some situations resulting in serious injury to passengers. To prevent the unintended unlocking, a pendulum like part called anti-g mass is attached to the buckle to block displacement of release button. In this study, the unlocking conditions of anti-g buckle when pre-tensioner explodes has been theoretically investigated. Through multibody model of the seatbelt system incorporating every detailed part of the buckle, dynamic analysis of the seatbelt system with pre-tensioner has been performed including the driver's body model that interacts with seatbelt system. The simulations results has been validated through actual sled test with driver dummy and the seatbelt system.

  • PDF

Field study of 5kW class PEMFC system (5kW급 고분자전해질 연료전지 시스템 실증연구)

  • Lee, SooJae;Choi, Dae Hyun;Jun, HeeKwon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF