• Title/Summary/Keyword: Dynamic Load Calculation

Search Result 144, Processing Time 0.035 seconds

The plate on the nonlinear dynamic foundation under moving load

  • Phuoc T. Nguyen;Thieu V. Vi;Tuan T. Nguyen;Van T. Vu
    • Coupled systems mechanics
    • /
    • v.12 no.1
    • /
    • pp.83-102
    • /
    • 2023
  • First introduced in 2016, the dynamic foundation model is an interesting topic in which the foundation is described close to reality by taking into account the influence of the foundation mass in the calculation of oscillation and is an important parameter that should be considered. In this paper, a follow-up investigation is conducted with the object of the Mindlin plate on a nonlinear dynamic foundation under moving loads. The base model includes nonlinear elastic springs, linear Pasternak parameters, viscous damping, and foundation mass. The problem is formulated by the finite element analysis and solved by the Newmark-β method. The displacement results at the center of the plate are analyzed and discussed with the change of various parameters including the nonlinear stiffness, the foundation mass, and the load velocity. The dynamic response of the plate sufficiently depends on the foundation mass.

Evaluation on Reducing Peak Cooling Load Based on Dynamic Load Model of Building Perimeter Zones (건물의 외주부 존에 대한 동적 부하모델 이용 피크냉방부하 저감효과 분석)

  • Lee, Kyoung-Ho;Brau, James E.
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, inverse building modeling was applied to building perimeter zones which have different window orientation. Two test zones of east-facing and west-facing zones in ERS(Energy Resource Station) building, which is representative of small commercial building, was used to test performance of cooling load calculation and peak cooling load reduction. The dynamic thermal load model for the east and west zone was validated using measured data for the zones and then it was used to investigate the effect of peak cooling load reduction by adjustment of indoor cooling temperature set points during on-peak time period. For the east zone, the peak load can be reduced to about 60% of the peak load for conventional control even without any precooling. For the west zone, PLR is nearly independent of the start of the on-peak period until a start time of 1pm. Furthermore, PLR has a small dependence on the precooling duration. Without any precooling, the peak cooling load can be reduced to about 35% of the peak load associated with conventional control.

A Study on Development of Simplified Thermal Load Calculation Program for Building Energy Analysis (건물에너지 해석을 위한 간이열부하 해석프로그램 개발에 관한 연구)

  • Kang, Yoon-Suk;Um, Mi-Eun;Ihm, Pyeong-Chan;Park, Jong-Il
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.72-77
    • /
    • 2008
  • About 25% of overall energy use of Korea had been spent in buildings. It is crucial to acknowledge the importance of saving energy in buildings. In order to save energy, it is important to predict accurate energy use. There are numerous energy simulation program that predicts both energy load and energy use. The problem of the energy simulation program is that it holds too many input variables, and it needs experts to model a building. So, our purpose of this study is to develop the simplified thermal load calculation program for building energy analysis which eliminates coordinates of building components instead of using full coordinates by using DOE2. Since the engine of the program is DOE2, we verified the validity of S-DOE by comparing peak heating & cooling load results and annual energy use results. The results shows that there are little difference between VisualDOE and S-DOE. Also it showed that S-DOE took less time to input variables than VisualDOE. These results reveals that the application of S-DOE is possible to accurately predict energy load and energy use of the building and still have strong point that it takes less time to analyse building energy.

  • PDF

Intermittent Heating and Cooling Load Calculation Method -Comparing with ISO 13790

  • Lee, Sang-Hoon
    • Architectural research
    • /
    • v.14 no.1
    • /
    • pp.11-18
    • /
    • 2012
  • College of Architecture, Georgia Institute of Technology, Atlanta, GA, US Abstract The intermittent heating and cooling energy need calculation of the ISO 13790 monthly method was examined. The current ISO 13790 method applies a reduction factor to the continuous heating and cooling need calculation result to derive the intermittent heating and cooling for each month. This paper proposes a method for the intermittent energy need calculation based on the internal mean temperature calculation. The internal temperature calculation procedure was introduced considering the heat-balance taking into account of heat gain, heat loss, and thermal inertia for reduced heating and cooling period. Then, the calculated internal mean temperature was used for the intermittent heating and cooling energy need calculation. The calculation results from the proposed method were compared to the current ISO 13790 method and validated with a dynamic simulation using EnergyPlus. The study indicates that the intermittent heating and cooling energy need calculation method using the proposed model improves transparency of the current ISO 13790 method and draws more rational outcomes in the monthly heating and cooling energy need calculation.

Improved definition of dynamic load allowance factor for highway bridges

  • Zhou, Yongjun;Ma, Zhongguo John;Zhao, Yu;Shi, Xiongwei;He, Shuanhai
    • Structural Engineering and Mechanics
    • /
    • v.54 no.3
    • /
    • pp.561-577
    • /
    • 2015
  • The main objective of this paper is to study the dynamic load allowance (DLA) calculation methods for bridges according to the dynamic response curve. A simply-supported concrete bridge with a smooth road surface was taken as an example. A half-vehicle model was employed to calculate the dynamic response of deflection and bending moment in the mid-span section under different vehicle speeds using the vehicle-bridge coupling method. Firstly, DLAs from the conventional methods and code provisions were analyzed and critically evaluated. Then, two improved computing approaches for DLA were proposed. In the first approach, the maximum dynamic response and its corresponding static response or its corresponding minimum response were selected to calculate DLA. The second approach utilized weighted average method to take account of multi-local DLAs. Finally, the DLAs from two approaches were compared with those from other methods. The results show that DLAs obtained from the proposed approaches are greater than those from the conventional methods, which indicate that the current conventional methods underestimate the dynamic response of the structure. The authors recommend that the weighted average method based on experiments be used to compute DLAs because it can reflect the vehicle's whole impact on the bridge.

A Study on Side Impact Simulation Technique using Simple Beam Model (단순 보모델을 이용한 측면충돌 해석기술 연구)

  • 강성종
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.170-177
    • /
    • 1997
  • In this study, an analysis technique using simple beam model for predicting structure crashworthiness of the passenger car side impacted with an angle by another passenger car was investigated. The simple model was composed of major beam-like side structure which carry almost all side impact load. A procedure of component collapse test, calculation of load carrying capability and dynamic simulation was carryed out sequentially. Transient dynamic algorithms and a computer program to simulate deformations and motions of the impacted car was developed. The developed procedure was applied to a 3 door passenger car side impacted with an angle of 75 degree and the analysis results show good agreements with the actual test results.

  • PDF

Characteristics of Bearing Capacity and Reliability-based Evaluation of Pile-Driving Formulas for H Pile (H-pile의 지지력 특성 및 동역학적 공식의 신뢰도 평가)

  • 오세욱;이준대
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.1
    • /
    • pp.81-88
    • /
    • 2003
  • Recently, pile foundations were constructed in rough or soft ground than ground of well condition thus it is important that prediction of ultimate bearing capacity and calculation of proper safety factor applied pile foundation design. This study were performed to dynamic loading tests for the thirty two piles at four different construction sites and selected pile at three site were performed to static loading tests and then compare with measured value and value of static and dynamic loading tests. The load-settlement curve form the dynamic loading tests by CAPWAP was very similar to the results obtained from the static load tests. Based on dynamic and static loading tests, the reliability of pile-driving formula were analyzed and then suggested with proper safety factor for prediction of allowable bearing capacity in this paper.

DYNAMIC ANALYSIS AND DESIGN CALCULATION METHODS FOR POWERTRAIN MOUNTING SYSTEMS

  • Shangguan, W.B.;Zhao, Y.
    • International Journal of Automotive Technology
    • /
    • v.8 no.6
    • /
    • pp.731-744
    • /
    • 2007
  • A method for dynamic analysis and design calculation of a Powertrain Mounting System(PMS) including Hydraulic Engine Mounts(HEM) is developed with the aim of controlling powertrain motion and reducing low-frequency vibration in pitch and bounce modes. Here the pitch mode of the powertrain is defined as the mode rotating around the crankshaft of an engine for a transversely mounted powertrain. The powertrain is modeled as a rigid body connected to rigid ground by rubber mounts and/or HEMs. A mount is simplified as a three-dimensional spring with damping elements in its Local Coordinate System(LCS). The relation between force and displacement of each mount in its LCS is usually nonlinear and is simplified as piecewise linear in five ranges in this paper. An equation for estimating displacements of the powertrain center of gravity(C.G.) under static or quasi-static load is developed using Newton's second law, and an iterative algorithm is presented to calculate the displacements. Also an equation for analyzing the dynamic response of the powertrain under ground and engine shake excitations is derived using Newton's second law. Formulae for calculating reaction forces and displacements at each mount are presented. A generic PMS with four rubber mounts or two rubber mounts and two HEMs are used to validate the dynamic analysis and design calculation methods. Calculated displacements of the powertrain C.G. under static or quasi-static loads show that a powertrain motion can meet the displacement limits by properly selecting the stiffness and coordinates of the tuning points of each mount in its LCS using the calculation methods developed in this paper. Simulation results of the dynamic responses of a powertrain C.G. and the reaction forces at mounts demonstrate that resonance peaks can be reduced effectively with HEMs designed on the basis of the proposed methods.

The Study of Dynamic Characteristic Analysis of PMLSM according to Disturbance Load (영구자석형 선형 동기기의 부하 외란에 따른 동특성에 관한 고찰)

  • Lee, Seung-Hoon;Jang, Ki-Bomg;Kim, Gyu-Tak
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.82-84
    • /
    • 2007
  • In this paper, the dynamic characteristic according to disturbance load of Permanent magnet Linear Synchronous Motor(PMLSM) is dealt with carefully. In order to analyze dynamic characteristics, the simulink of Matlab is used. And F.E.M. is used for calculation of the parameter of PMLSM. The measuring system of the dynamic characteristics is manufactured and experiment results are compared with simulation results.

  • PDF

Aspects of the dynamic wind-induced response of structures and codification

  • Tamura, Yukio;Kareem, Ahsan;Solari, Giovanni;Kwok, Kenny C.S.;Holmes, John D.;Melbourne, William H.
    • Wind and Structures
    • /
    • v.8 no.4
    • /
    • pp.251-268
    • /
    • 2005
  • This paper describes the work of the International Association for Wind Engineering Working Group E -Dynamic Response, one of the International Codification Working Groups set up at the Tenth International Conference on Wind Engineering in Copenhagen. Comparisons of gust loading factors and wind-induced responses of major codes and standards are first reviewed, and recent new proposals on 3-D gust loading factor techniques are introduced. Then, the combined effects of along-wind, crosswind and torsional wind load components are discussed, as well as the dynamic characteristics of buildings. Finally, the mathematical forms of along-wind velocity spectra for along-wind response calculation and codification of acceleration criteria are discussed.