• Title/Summary/Keyword: Dynamic Failure Behavior

Search Result 239, Processing Time 0.029 seconds

Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems (자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가)

  • Hu, Jong Wan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.1025-1037
    • /
    • 2015
  • Flexible base isolation bearings that separate superstructure from ground have been widely used in the construction field because they make a significant contribution to increasing the fundamental period of the structure, thereby decreasing response acceleration transmitted into the superstructure. However, the established bearing devices installed to uphold the whole building give rise to some problems involved with failure and collapse due to lack of the capacity as modern structures are getting more massive and higher. Therefore, this study suggests new isolation bearings assembled with additional restrainers enabled to reinforcing and recentering, and then evaluates their performance to withstand the seismic load. The superelastic shape memory alloy (SMA) bars are installed into the conventional lead-rubber bearing (LRB) devices in order to provide recentering forces. These new systems are modeled as component spring models for the purpose of conducting nonlinear dynamic analyses with near fault ground motion data. The LRB devices with steel bars are also designed and analyzed to compare their responses with those of new systems. After numerical analyses, ultimate strength, maximum displacement, permanent deformation, and recentering ratio are compared to each model with an aim to investigate which base isolation models are superior. It can be shown that LRB models with superelastic SMA bars are superior to other models compared to each other in terms of seismic resistance and recentering effect.

Rheological and Failure Properties of Polycarbonate/Poly(butylene terephthalate) Blends (폴리카보네이트/폴리(부틸렌 테레프탈레이트) 블렌드의 유변학적 및 파괴특성)

  • Nah, Chang-Woon;Huh, Mong-Young;Choi, Dae-Hwan;Kook, Jeong-Ho;Hwang, In-Ra;Jeong, Kwang-Un;Hong, Chang-Kook
    • Polymer(Korea)
    • /
    • v.31 no.5
    • /
    • pp.399-403
    • /
    • 2007
  • Trans-esterification behavior of polycarbonate/poly(butylene terephthalate) (PC/PBT) blends was investigated during the melt mixing process. Rheological and fracture behaviors, and fracture morphology were also investigated as a function of PC/PBT blend ratio. Based on FT-IR and $^1H-NMR$ results, a trans-esterification reaction was confirmed to occur between PC and PBT during the melt mixing process. The melt index(MI) decreased with increased PC content, indicating the higher flow resistance of PC. The storage and loss moduli were increased by increasing the PC loading, and the PC/PBT blends were rheologically incompatible based on the Cole-Cole plot. The tensile property increased linearly with the increased PC content. However, the impact strength increased until 50 wt% of PC loading, notably around $30{\sim}40wt%$, and then was levelled off at 50 wt%. Rough ridges were formed on the impact fracture surfaces above the 40 wt% of PC content, supporting the observed higher impact strength in this range.

Seismic Vulnerability Assessment of RC Frame Structures Using 3D Analytical Models (3차원 해석 모델을 이용한 RC 프레임 구조물의 지진 취약도 평가)

  • Moon, Do-Soo;Lee, Young-Joo;Lee, Sangmok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.724-731
    • /
    • 2016
  • As the structural damage caused by earthquakes has been gradually increasing, estimating the seismic fragility of structures has become essential for earthquake preparation. Seismic fragility curves are widely used as a probabilistic indicator of structural safety against earthquakes, and many researchers have made efforts to develop them in a more accurate and effective manner. However, most of the previous research studies used simplified 2D analytical models when deriving fragility curves, mainly to reduce the numerical simulation time; however, in many cases 2D models are inadequate to accurately evaluate the seismic behavior of a structure and its seismic vulnerability. Thus, this study provides a way to derive more accurate, but still effective, seismic fragility curves by using 3D analytical models. In this method, the reliability analysis software, FERUM, is integrated with the structural analysis software, ZEUS-NL, enabling the automatic exchange of data between these two software packages, and the first order reliability method (FORM), which is not a sampling-based method, is utilized to calculate the structural failure probabilities. These tools make it possible to conduct structural reliability analyses effectively even with 3D models. By using the proposed method, this study conducted a seismic vulnerability assessment of RC frame structures with their 3D analytical models.

Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing (유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가)

  • Kim, Jin-Seon;Lee, Kang-Seok
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.4
    • /
    • pp.83-91
    • /
    • 2021
  • In this study, to improve the connection performance between the existing reinforced concrete (R/C) frame and the strengthening member, we proposed a new H-section steel frame with elastic pad (HSFEP) system for seismic rehabilitation of existing medium-to-low-rise reinforced concrete (R/C) buildings. This HSFEP strengthening system exhibits an excellent connection performance because an elastic pad is installed between the existing structure and reinforcing frame. The method shows a strength design approach implemented via retrofitting, to easily increase the ultimate lateral load capacity of R/C buildings lacking seismic data, which exhibit shear failure mechanism. Two full-size two-story R/C frame specimens were designed based on an existing R/C building in Korea lacking seismic data, and then strengthened using the HSFEP system; thus, one control specimen and one specimen strengthened with the HSFEP system were used. Pseudodynamic tests were conducted to verify the effects of seismic retrofitting, and the earthquake response behavior with use of the proposed method, in terms of the maximum response strength, response displacement, and degree of earthquake damage compared with the control R/C frame. Test results revealed that the proposed HSFEP strengthening method, internally applied to the R/C frame, effectively increased the lateral ultimate strength, resulting in reduced response displacement of R/C structures under large scale earthquake conditions.

Case study of dramatherapy for a bulmina nervosa patient (폭식증 환자의 연극치료 사례)

  • Lee, Hyowon
    • Journal of Korean Theatre Studies Association
    • /
    • no.52
    • /
    • pp.359-397
    • /
    • 2014
  • This paper describes dramatherapy with a bulmina nervosa patient. She was in her early 20s and has been under the various psychotherapies for cure of deep depression since 2005. We had 24 sessions and 3 persons - the patient, the therapist, and the assist-therapist- participated in dramatherapy. I found there's a big collision between her important roles in the course of initial interview and diagnosis. Those roles are 'a good daughter of mom' and 'an independent adult'. Therefore I defined her bulmina nervosa as 'an symbolic behavior repeats compulsively the failure of separation from her mother.' And I set the general goals, the separation from her mother, the awareness and expression of negative emotions, and the diminuation of overeating and vomiting. To attain these object, we had many different dramatic experiences in dramatherapy. We made a self-portrait, the mask of bulmina nervosa, family sculpture, figure work, the past I and the present I, psychodramatic scene and several stories. In order to objective assessment, I used behavioral observation and 6PSM(6 Pieces Story Making) analysis. First of all the most noticeable change was a rapid decrease in over-eating and vomiting. Before the dramatherapy she had overeaten 30 times per week. At the closure it has fallen off to 1 time per week. Another behavioral changes were shift of outward appearance, not going church, working for living, and having a date with only one. She made 3 stories on 1th session, 13th session, and 23th session. And I comparatively analysed those stories with both qualitative and quantitative method. For qualitative analysis, I classified 5 structures according to the substantial similrarity. On protagonist structure, there's no difference. Three protagonists are dead things. The type of task structure is changed from an escape, a traveling, to metamorphosis. The type of obstruction structure is changed from the protagonist to an outside object. The type of closure structure is changed from an exaggerated happy ending, sad ending to probable happy ending. To quantitify the aspects of transformation, I developed an assesment tool using likert scale. It is composed of 4 sub-categories-reality testing, imagination, ego-strength, optimism problem-solving. In reality testing category, a shift of score was 9-11-15, imagination 2-5-5, ego strength 3-2-2, optimism 6-3-7, and total score 20-21-29. This change of score reflects the growth of problem solving capacity. Viewed in this light, dramatherapy with this girl was successful on the whole. The thing had significant effect on it was psycho-dynamic approach focused on separation from her mother and defence mechanism to avoid negative emotion. And assessment method used in this case will be full of suggestions to researches to come.

Effect of Repeated Wet/Dry Cycles of Salt Solution on Flexural Performance of Steel Fiber Reinforced Concrete (반복적 염수침지가 강섬유 혼입 콘크리트의 휨성능에 미치는 영향)

  • Kim, Ji-Hyun;Choi, Yu-Jin;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.553-564
    • /
    • 2022
  • Concrete is a representative composite material that shows excellent performance in the construction field. However, it is a brittle and nonhomogeneous material and exhibits weak behavior against bending and tensile forces. To compensate for such weakens, fiber reinforcement has been utilized, and steel fiber has been recognized as one of the best material for such purpose. However, steel fiber can seriously affect the durability of concrete exposed to the marine environment due to the corrosion caused by chlorine ions. This study intended to evaluate the mechanical performance of steel fiber reinforce concrete during and after repeated wet/dry cycles in salt solution. According to the experimental results, there was no reduction in the relative dynamic modulus of concrete during the repeated wet/dry cycles in salt solution for 37 weeks. Flexural strength was not decreased after completion of repeated wet/dry cycles in salt solution. There was no sign of corrosion in steel fibers after visual observation of fractured surface. However, the flexural toughness was decreased, and this is because about half of the concrete specimen showed failure before reaching the maximum displacement of 3 mm. Although repeated wet/dry cycles in salt solution did not cause cracks in concrete through corrosion of steel fibers, specific attention is required because it can reduce flexural toughness of steel fiber reinforced concrete.

Effects of particle size and loading rate on the tensile failure of asphalt specimens based on a direct tensile test and particle flow code simulation

  • Q. Wang;D.C. Wang;J.W. Fu;Vahab Sarfarazi;Hadi Haeri;C.L. Guo;L.J. Sun;Mohammad Fatehi Marji
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.607-619
    • /
    • 2023
  • This study, it was tried to evaluate the asphalt behavior under tensile loading conditions through indirect Brazilian and direct tensile tests, experimentally and numerically. This paper is important from two points of view. The first one, a new test method was developed for the determination of the direct tensile strength of asphalt and its difference was obtained from the indirect test method. The second one, the effects of particle size and loading rate have been cleared on the tensile fracture mechanism. The experimental direct tensile strength of the asphalt specimens was measured in the laboratory using the compression-to-tensile load converting (CTLC) device. Some special types of asphalt specimens were prepared in the form of slabs with a central hole. The CTLC device is then equipped with this specimen and placed in the universal testing machine. Then, the direct tensile strength of asphalt specimens with different sizes of ingredients can be measured at different loading rates in the laboratory. The particle flow code (PFC) was used to numerically simulate the direct tensile strength test of asphalt samples. This numerical modeling technique is based on the versatile discrete element method (DEM). Three different particle diameters were chosen and were tested under three different loading rates. The results show that when the loading rate was 0.016 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis till coalescence to the model boundary. When the loading rate was 0.032 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis. The branching occurs in these cracks. This shows that the crack propagation is under quasi-static conditions. When the loading rate was 0.064 mm/sec, mixed tensile and shear cracks were initiated below the loading walls and branching occurred in these cracks. This shows that the crack propagation is under dynamic conditions. The loading rate increases and the tensile strength increases. Because all defects mobilized under a low loading rate and this led to decreasing the tensile strength. The experimental results for the direct tensile strengths of asphalt specimens of different ingredients were in good accordance with their corresponding results approximated by DEM software.

Rainfall Forecasting Using Satellite Information and Integrated Flood Runoff and Inundation Analysis (I): Theory and Development of Model (위성정보에 의한 강우예측과 홍수유출 및 범람 연계 해석 (I): 이론 및 모형의 개발)

  • Choi, Hyuk Joon;Han, Kun Yeun;Kim, Gwangseob
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.6B
    • /
    • pp.597-603
    • /
    • 2006
  • The purpose of this study is to improve the short term rainfall forecast skill using neural network model that can deal with the non-linear behavior between satellite data and ground observation, and minimize the flood damage. To overcome the geographical limitation of Korean peninsula and get the long forecast lead time of 3 to 6 hour, the developed rainfall forecast model took satellite imageries and wide range AWS data. The architecture of neural network model is a multi-layer neural network which consists of one input layer, one hidden layer, and one output layer. Neural network is trained using a momentum back propagation algorithm. Flood was estimated using rainfall forecasts. We developed a dynamic flood inundation model which is associated with 1-dimensional flood routing model. Therefore the model can forecast flood aspect in a protected lowland by levee failure of river. In the case of multiple levee breaks at main stream and tributaries, the developed flood inundation model can estimate flood level in a river and inundation level and area in a protected lowland simultaneously.

Comparisons on the Interface Shear Strength of Geosynthetics Evaluated by Using Various Kinds of Testing Methods (다양한 시험법에 의해 산정된 토목섬유 사이의 접촉면 전단강도 비교)

  • Seo, Min-Woo;Oh, Myoung-Hak;Yoon, Hyun-Suk;Park, Jun-Boum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.2C
    • /
    • pp.73-80
    • /
    • 2006
  • The shear behavior of four different interfaces consisting of four types of geosynthetics was investigated, and both static and dynamic test for the geosynthetic interfaces were conducted. The monotonic shear experiments were performed by using an inclined board apparatus and large direct shear device. The interface shear strength obtained from the inclined board test was compared with calculated values from large direct shear tests. The comparison results indicated that direct shear tests show high possibility to over-predict the shear strength in the low normal stress range where direct shear tests are not performed. Curved failure envelopes were also obtained for interface cases where two static shear tests were conducted. By comparing the friction angles measured from three tests, i.e. direct shear, inclined board, and shaking table test, it was found that the friction angle might be different depending on the test method and normal stresses applied in the research. Therefore, it was concluded that the testing method should be determined carefully by considering the type of loads and the normal stress expected in the field with using the geosynthetic materials installed in the site.