• 제목/요약/키워드: Dynamic ECG

검색결과 26건 처리시간 0.031초

ECG 원칩 솔루션의 진단용 심전계 적용을 위한 타당성 연구 (A Feasibility Study for Application of Single-Chip Solution for Diagnostic Resting ECG)

  • 강범선;최기상
    • 대한의용생체공학회:의공학회지
    • /
    • 제36권4호
    • /
    • pp.86-94
    • /
    • 2015
  • In order for medical devices to be used outside hospital, they have to be not only of small size but also power consumption has to be kept at low level. This study investigates the feasibility of application of ADS1298 ECG single-chip solution developed by Texas Instruments Inc. for use in development of a new platform for diagnostic resting ECG. To prove the feasibility of commercial products based on the ADS1298 chip, the performance of the ADS1298 chip was measured in terms of input impedance, common mode rejection, frequency response, and input dynamic range using the testing method under the suitability criteria of the IEC 60601-2-25 standard. Result of the this study shows that commercialization of the ECG products based on the ADS1298 ECG single-chip solution that satisfies the international standards would be possible, if the manufactures take the filter characteristics into account in building a new platform for diagnostic resting ECG.

착용형 심장활동 모니터링 시스템을 활용한 정신적 스트레스 평가 (The Assessment of Dynamic Mental Stress with Wearable Heart Activity Monitoring System)

  • 김경섭;신승원;이정환;최희정
    • 전기학회논문지
    • /
    • 제57권6호
    • /
    • pp.1109-1115
    • /
    • 2008
  • In the ubiquitous health monitoring environments, it is quite important not only to evaluate the physiological health condition but also mental stress condition. In order to achieve this goal, a heart activity monitoring system utilizing a wearable bipolar electrode is devised and the heart rate variability(HRV) is extracted and interpreted in both frequency and time feature domains. Consequently, to evaluate the emotional stress condition of the subjects, a stress-induced experimental protocol was applied to healthy subjects and the time and frequency features of heart activity were analyzed in terms of the ratio of low frequency components v.s., high frequency components and the relevant the moving average distributions compromising the successive RR peaks intervals in the ambulatory ECG measurement system.

DTW 최소누적거리를 이용한 심전도 이상 검출 알고리즘 구현 및 평가 (Implementation and Evaluation of Abnormal ECG Detection Algorithm Using DTW Minimum Accumulation Distance)

  • 노윤홍;이영동;정도운
    • 센서학회지
    • /
    • 제21권1호
    • /
    • pp.39-45
    • /
    • 2012
  • Recently the convergence of healthcare technology is used for daily life healthcare monitoring. Cardiac arrhythmia is presented by the state of the heart irregularity. Abnormal heart's electrical signal pathway or heart's tissue disorder could be the cause of cardiac arrhythmia. Fatal arrhythmia could put patient's life at risk. Therefore arrhythmia detection is very important. Previous studies on the detection of arrhythmia in various ECG analysis and classification methods had been carried out. In this paper, an ECG signal processing techniques to detect abnormal ECG based on DTW minimum accumulation distance through the template matching for normalized data and variable threshold method for ECG R-peak detection. Signal processing techniques able to determine the occurrence of normal ECG and abnormal ECG. Abnormal ECG detection algorithm using DTW minimum accumulation distance method is performed using MITBIH database for performance evaluation. Experiment result shows the average percentage accuracy of using the propose method for Rpeak detection is 99.63 % and abnormal detection is 99.60 %.

이동형 심전도 신호의 잡음 제거 및 유사도 평가 (Noise Reduction and Estimating the Similarity of Ambulatory ECG Signals)

  • 신승원;이정환;이강휘;김동준;김경섭
    • 전기학회논문지
    • /
    • 제57권3호
    • /
    • pp.507-513
    • /
    • 2008
  • In this study, we develope an ambulatory ECG acquisition system by implementing a patch-style and wireless electrode. To alleviate the inherent noisy characteristics of the mobile signal, we apply a matched filter and concurrently detect R-peak values. Moreover, the measure for resolving shape distance is computed to estimate the relative similarity between two ECG signals and to decide whether the abnormal characteristics in ECG exist or not.

워핑(Warping) 기법을 이용한 심전도 신호 자동 분할 (Automated ECG Signal Segmentation by Warping Method)

  • 신승원;김경섭;윤태호;이정환;김동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1918-1919
    • /
    • 2007
  • In this study, dynamic time warping(DTW) is utilized especially for automatically segmenting ECG(Electrocardiogram) signal to extract a periodic time information. For the possible medical application for diagnosing the abnormalities of ECG, the relative metric distance of the warped ECG signals are computed to decide whether the abrupt variations of ECG signal occur or not.

  • PDF

Improved Dynamic Programming in Local Linear Approximation Based on a Template in a Lightweight ECG Signal-Processing Edge Device

  • Lee, Seungmin;Park, Daejin
    • Journal of Information Processing Systems
    • /
    • 제18권1호
    • /
    • pp.97-114
    • /
    • 2022
  • Interest is increasing in electrocardiogram (ECG) signal analysis for embedded devices, creating the need to develop an algorithm suitable for a low-power, low-memory embedded device. Linear approximation of the ECG signal facilitates the detection of fiducial points by expressing the signal as a small number of vertices. However, dynamic programming, a global optimization method used for linear approximation, has the disadvantage of high complexity using memoization. In this paper, the calculation area and memory usage are improved using a linear approximated template. The proposed algorithm reduces the calculation area required for dynamic programming through local optimization around the vertices of the template. In addition, it minimizes the storage space required by expressing the time information using the error from the vertices of the template, which is more compact than the time difference between vertices. When the length of the signal is L, the number of vertices is N, and the margin tolerance is M, the spatial complexity improves from O(NL) to O(NM). In our experiment, the linear approximation processing time was 12.45 times faster, from 18.18 ms to 1.46 ms on average, for each beat. The quality distribution of the percentage root mean square difference confirms that the proposed algorithm is a stable approximation.

24시간 HOLTER ECG에서 QT interval 분석을 위한 새로운 Algorithm에 관한 연구 (A New algorithm for at interval analysis in 24 hour Holter BCG)

  • 윤형로;이윤선;이경중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1989년도 춘계학술대회
    • /
    • pp.13-14
    • /
    • 1989
  • Prolongation in QT corrected interval (QTc), measured in surface ECG, has been shown in the majority af patients to be marker of bad prognosis in postmyocardial infarction patients (PMIP). Hence it would seem logical that dynamic QTc interval measurement can be a very usefull indicator to stratify prognosis in PMIP. We present a new algorithm for QT as well as for QTP (distance value from Q wave onset to T wave peak) intervals measurement in 24 hour ECG Holter tapes. Validation of the algorithm by hand measurement has been done on first beats of 18 Holter tapes, resulting in a magnitude of deviations between 10 and 15 ms. Application on 24 hour Holter ECG signal has also been done.

  • PDF

RF 무선통신 기술을 이용한 심전도 및 온.습도 측정 시스템 (The Measurement System of ECG, Temperature and Humidity Using RF wireless Communication Technique)

  • 임진희;남효덕;정우철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.356-357
    • /
    • 2007
  • In this paper, we developed an integrated miniaturized device which acquires and transmits the signal of ECG an interested heartbeat and body's temperature and humidity. Using an amplifier circuit on the electrodes and the radio frequency transmission, the developed system dispenses with the use of cables among the electrodes, amplifier, and the post processing system. The sensor signals are transmitted to the RF-wireless terminal that was developed using the micro controller Aduc812, LCD, RF-module (frequency 424MHz, 9600-bps). In results, the developed system improves not only the signal-to-noise ration in dynamic ECG & and body's temperature and humidity measurement, but also the user convenience.

  • PDF

심전도와 심탄도의 무구속적 동시 측정을 위한 의자 등받이 개발 (Development of Chair Backrest for Non-intrusive Simultaneous Measurement of ECG and BCG)

  • 임용규
    • 융합신호처리학회논문지
    • /
    • 제19권3호
    • /
    • pp.104-109
    • /
    • 2018
  • 심전도와 심탄도를 무구속적으로 동시에 측정하는 시스템을 개발하였다. 제안된 시스템은 의자의 보조 등받이에 설치되어 맥파전달시간(PAT), Pre-ejection period (PEP) 등의 심혈관계 역학 정보를 일상생활에서 무구속적으로 측정하는 것을 목적으로 개발되었다. 본 연구에서는, 의자의 등받이에 부착된 용량성 능동전극과 용량성 접지를 이용한 간접접촉 심전도 (IDC-ECG) 측정 방법에 의해 무구속적으로 심전도를 측정하였으며, 등받이에 부착된 EMFi 압력 센서를 사용하여 무구속적으로 심탄도(ballistocardiogram)를 측정하였다. 제안된 시스템으로 심전도와 심탄도가 무구속적으로 동시에 측정됨을 확인하였으며, 측정된 심탄도는 피검자 사이에서 일정한 패턴을 보이는 것을 알 수 있었다. 또한 심전도의 Q파와 심탄도의 첫 번째 첨두간의 시간차가 pre-ejection period와 높은 상관관계를 보이는 것도 확인할 수 있었다. 이 연구에서 개발된 시스템은 심혈관계의 다양한 지표(심전도, 심박수, PAT, PEP 등)를 무구속적으로 일상생활에서 측정할 수 있음을 보였다.

차감 동작 기법 기반의 효율적인 R파 검출 (Efficient R Wave Detection based on Subtractive Operation Method)

  • 조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제17권4호
    • /
    • pp.945-952
    • /
    • 2013
  • QRS 영역 중 R파는 ECG 신호 중 가장 큰 대표 신호라 할 수 있으며, 이 점을 기준으로 다양한 특징점을 검출하기 때문에 R파의 검출성능을 높이기 위해 많은 노력을 기울여 왔다. 하지만 R파 검출은 여러 종류의 잡음성분들로 인하여 이를 분석하는데 어려움을 준다. 또한 QRS 영역의 진폭과 유사한 T파나 P파를 R파로 오인함으로써 검출의 어려움이 발생한다. ECG 신호처리는 하드웨어 및 소프트웨어 자원에 대한 효율성을 고려해야 하며, 소형화 및 저 전력을 위해 단순해야 한다. 즉, 최소한의 연산량으로 정확한 R파를 검출함으로써 다양한 부정맥을 분류할 수 있는 적합한 알고리즘의 설계가 필요하다. 따라서 본 연구에서는 차감 동작 기법(Subtractive Operation Method, 이하 SOM) 기반의 심전도 신호의 R파 검출 방법을 제안한다. 이를 위해 형태 연산을 통한 전처리 과정과 경험적 문턱값과 차감신호를 통해 R파를 검출하였으며, 검출의 효율성을 위하여 RR 간격을 이용한 동적 역탐색 기법을 적용하였다. 제안한 알고리즘의 R파 검출 성능을 평가하기 위해서 MIT-BIH 부정맥 데이터베이스를 사용하였다. 성능평가 결과, R파는 평균 99.41%의 검출결과가 나타났다.