• Title/Summary/Keyword: Dynamic CT

Search Result 143, Processing Time 0.029 seconds

Treatment of Quadriceps Contracture with Femoral Shortening Ostectomy, Rectus Femoris Muscle Transposition and Dynamic Stifle Flexion Apparatus in a Dog

  • Roh, Yoon-Ho;Choi, Min-Ho;Lee, Je-Hun;Mok Jeong, Seong;Lee, HaeBeom
    • Journal of Veterinary Clinics
    • /
    • v.37 no.3
    • /
    • pp.163-167
    • /
    • 2020
  • A 13-month-old, 3.3 kg castrated male Shih-tzu presented with right hindlimb lameness. The physical examination revealed atrophy of the right thigh muscles, hyperextension of the stifle joint and external torsion of the tibia. On the radiographic examination, patella alta and genu recurvatum were observed. A biapical deformity of the tibia and external torsion of the distal tibia were detected by computed tomography (CT). A three-dimensional (3D) printed bone model was designed and constructed for the preoperative plan prior to surgery. Rectus femoris muscle transposition, femoral shortening ostectomy and open wedge osteotomy of the distal tibia were performed using hybrid external skele/t0al fixation (hybrid-ESF). A dynamic stifle flexion apparatus was used to prevent recurrence of a quadriceps contracture (QC). Intense physiotherapy was administered postoperatively. The dog began to use the affected limb one week after surgery. Functional improvement in the affected limb was observed, and full weight-bearing was possible at 3 months after surgery. Union of the osteotomy lines was observed at 3 months, and the stifle joint was fully movable at 7 months after surgery. Regarding the treatments for QC, these methods may be excellent candidates, as they do not lead to severe damage to the limb or amputation.

Implementation of 3D Video using Time-Shortening Algorithm (시간단축 알고리즘을 통한 3D 동영상 구현)

  • Shin, Jin-Seob;Jeong, Chan-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.6
    • /
    • pp.123-128
    • /
    • 2020
  • In this paper, we presents a new cone beam computerized tomography (CBCT) system for the reconstruction of 3 dimensional dynamic images. The system using cone beam has less the exposure of radioactivity than fan beam, relatively. In the system, the reconstruction 3-D image is reconstructed with the radiation angle of X-ray in the image processing unit and transmitted to the monitor. And in the image processing unit, the Three Pass Shear Matrices, a kind of Rotation-based method, is applied to reconstruct 3D image because it has less transcendental functions than the one-pass shear matrix to decrease a time of calculations for the reconstruction 3-D image in the processor. The new system is able to get 3~5 3-D images a second, reconstruct the 3-D dynamic images in real time. And we showed the Rotation-based method was good rather than existing reconstruction technique for 3D images, also found weakness and a solution for it.

A 9 mW Highly-Digitized 802.15.4 Receiver Using Bandpass ∑Δ ADC and IF Level Detection

  • Kwon, Yong-Il;Park, Ta-Joon;Lee, Hai-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.8 no.2
    • /
    • pp.76-83
    • /
    • 2008
  • A low power(9 mW) highly-digitized 2.4 GHz receiver for sensor network applications(IEEE 802.15.4 LR-WPAN) is realized by a $0.18{\mu}m$ CMOS process. We adopted a novel receiver architecture adding an intermediate frequency (IF) level detection scheme to a low-power complex fifth-order continuous-time(CT) bandpass L:tl modulator in order to digitalize the receiver. By the continuous-time bandpass architecture, the proposed $\Sigma\Delta$ modulator requires no additional anti-aliasing filter in front of the modulator. Using the IF detector, the achieved dynamic range(DR) of the over-all system is 95 dB at a sampling rate of 64 MHz. This modulator has a bandwidth of 2 MHz centered at 2 MHz. The power consumption of this receiver is 9.0 mW with a 1.8 V power supply.

The effects of vertebroplasty on adjacent vertebra (척추성형술이 인접 척추체에 미치는 영향)

  • Park, Jung-Soo;Choi, Chul-Hyun;Chae, Soo-Won
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.746-750
    • /
    • 2007
  • Vertebroplasty has drawn much attention as a medical treatment for the compression fracture of spine, which strengthens the vertebral body and corrects deformity, and relieves pain in patients by injecting bone cement. However vertebroplasty can cause fracture on adjacent vertebra due to relative stiffness change. This study involves the biomechanical evaluation of the vertebroplasty especially on adjacent vertebral body. The finite element method has been employed to analyze the patient who was treated vertebroplasty under static and dynamic loading. For this study, a three-dimentioal model of the three-level ligamentous lumbar segment ($L1{\sim}L3$)is created from medical image data (CT)and compared with the experimental results in vitro.

  • PDF

Establishment of 345kV transformer protective relay dynamic performance test environment (345kV 변압기 보호 계전기 동특성 성능검증 기반 구축)

  • Jang, B.T.;Choi, C.Y.;Kim, J.Y.;Lee, C.H.;Yang, G.J.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.101-102
    • /
    • 2006
  • 345kV 변전소는 국내 전력계통의 근간으로서 고장 시계통 안정도에 미치는 영향이 크기 때문에 고장 제거가 착신하고 신속해야 한다. 따라서 345kV 변전소의 보호 장치들은 CT, PT, 차단기(trip coil), 보호계전기, DC전원 등이 모두 2계열화되어 있으며 보호 계전기는 각 계열마다 주보호와 후비보호가 따로 구비되어 있다. 본 논문에서는 34skv 변압기 보호용 보호계전기에 내장된 계전요소들의 유기적인 성능 검증을 할 수 있는 동특성 시험에 관한 기반 구축 과정 및 결과에 대해서 기술한다.

  • PDF

A Study on the Optimization of the Alignment Considering the Ride Comfort in the Case of the Superimposition of Vertical and Horizontal Curves (종곡선/평면곡선 경합 시 승차감을 고려한 선형최적화에 관한 연구)

  • Um, Ju-Hwan;Yang, Sin-Chu;Choi, Il-Yoon
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1943-1950
    • /
    • 2010
  • Superimposition of horizontal and vertical curves may hamper the ride comfort and the running stability of train and largely affect the maintenance cost. However, in many cases, it's not easy to make a track plan because of the fixed points (bridge, tunnel, turnout, catenary system, etc.) to be avoided due to the geographic conditions or to be passed for utilization of existing structures. In this study, when the horizontal and vertical curves are superimposed, in order to optimize the horizontal curve in aspect of the ride comfort, the object function $P_{CT}$ was developed and verified by vehicle dynamic analysis. Also, the solution algorithm for simplified evaluation method was presented.

  • PDF

Modeling and Simulation of Human Knee Joint in Three Dimension By Using the Method of Optimal Triangular Patches (최단 거리 삼각형 패치 형성법을 이용한 무릎 관절의 3차원 형상 모델링과 시뮬레이션)

  • Moon, Byung-Young;Son, Kwon;Kim, Kwang-Hoon;Seo, Jung-Tak
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.12
    • /
    • pp.205-212
    • /
    • 2003
  • Many people are exposed to accidents by vehicles or sports. The most frequent injuries by these accidents is concerned with a knee joint. The three-dimensional surface model of a knee is needed for dynamic analysis of knee motion and knee reconstruction. three-dimensional motion data of a knee joint were obtained using X-ray and precise magnetic sensors. The surface data of a femur and a tibia were obtained using cross-sectional pictures by CT. The three-dimensional surface models of a femur and a tibia were made by the method of optimal triangular patch. Using obtained motion data, we simulated the motion of three-dimensional knee joint model.

Imaging diagnosis of clonorchiasis

  • Choi, Don-Gil;Hong, Sung-Tae
    • Parasites, Hosts and Diseases
    • /
    • v.45 no.2 s.142
    • /
    • pp.77-85
    • /
    • 2007
  • Among several diagnostic tools for clonorchiasis (Clonorchis sinensis infection), radiologic examinations are commonly used in clinical practices. During the 2 past decades, many reports regarding imaging findings of clonorchiasis were introduced. The basic imaging finding of clonorchiasis is diffuse dilatation of the peripheral intra-hepatic bile ducts, without dilation of the large intrahepatic or extrahepatic bile ducts. By this finding, however, active clonorchiasis cannot be differentiated from cured infection. Some recent radiologic studies suggested specific findings of active clonorchiasis. Besides direct demonstration of worms, increased periductal echogenicity on sonography and periductal enhancement on dynamic contrast-enhanced CT or MR imaging possibly represent active clonorchiasis. Those images of the liver clonorchiasis are known to be correlated with worm burdens (EPG counts) in their frequency and also severity. The images of cholangiocarcinoma associated with clonorchiasis show both the tumor with obstruction images and diffuse dilatation of the peripheral intrahepatic bile ducts. Radiological images can be a good practical alternative diagnostic method of clonorchiasis.

A Case of Isolated Right Pulmonary Artery Agenesis (고립성 우측 폐동맥 형성부전증 1례)

  • Kim, Do Youn;Lee, Jae Sung;Kim, Young;Chang, Yoon Soo;Kim, Hyung Jung;Kim, Tae Hoon;Ahn, Chul Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.57 no.5
    • /
    • pp.489-493
    • /
    • 2004
  • Unilateral pulmonary artery agenesis is a rare congenital anomaly usually associated with other cardiovascular anomalies such as tetralogy of Fallot or septal defect. Unilateral pulmonary artery agenesis without other coexisting cardiovascular abnormality (isolated unilateral pulmonary artery) is extremely rare and often asymptomatic until adulthood. In these patients, diagnostic clue is found in a plain chest roentgenogram, showing a hyperlucent contracted hemithorax. We have recently experienced a case of isolated right pulmonary artery agenesis, which was diagnosed by chest dynamic CT, perfusion scan, echocardiogram and 3-dimensional reconstruction cardiac CT angiography in a 50-year old female who had suffered from mild dyspnea on exertion and improved with conservative treatment. We report this case with a brief review of the relevant literature.

Clinical and Statistical Analysis in 452 Cases of Nasal Bone Fracture Patients (코뼈 골절 환자 452례에 대한 임상 통계학적 분석)

  • Kang, Jae-Hoon;Bang, Yoo-Hyun;Lee, Yong-Hae;Choi, Chang-Yong
    • Archives of Plastic Surgery
    • /
    • v.38 no.6
    • /
    • pp.775-782
    • /
    • 2011
  • Purpose: Nasal bone fracture is most common facial bone fracture. The cause of fractures is mainly trauma such as fighting, automobile accident and fall down, and it commonly involves young males. Very frequently nasal bone fractures are associated with other facial injuries such as orbital bone fracture, maxillary bone fracture and nasal septal deformities. Because of various dynamic directions of power are involved, phenomenon of fractures are also various and treatment cannot be simple. Methods: We studied and analyzed retrospectively 452 cases nasal bone fractures from January 2008 to December 2010. Diagnosis were made with physical examination, Nasal bone X-rays, Facial bone CT and 3D facial bone CT. Four surgeons are involved in treatments of these patients and applied different procedure along patient's condition and deformity. We analyzed the cause of nasal bone fractures, deformities, associate injuries and applied surgical technique, and patient's satisfaction rate. In this study, old nasal bone fractures were excluded. Results: Young male group was most commonly sustained nasal bone fracture and physical violence was most common cause of injury. 64 of 452 patient was involved associate injuries of face. Closed reduction were applied 246 cases and C-arm quide reduction were 167 cases and in 20 cases lateral osteotomy were applied. Approximately, more than 80% of the Patients were satisfied with the outcomes. Conclusion: Diagnosis and treatment of nasal bone fractures are considered simple but because of various deformity and associate injuries, treatment is not always simple and universal. Time to time, we face unsatisfied patient after treatment of nasal bone fractures. For obtaining satisfactory result, cause of injury and state of deformities and associate injuries such as nasal septal deformity should be evaluated properly and proper treatment should be applied.