• 제목/요약/키워드: Dye penetration

검색결과 181건 처리시간 0.024초

측방가압법과 System BTM를 이용한 근관충전시 근관만곡도에 따른 폐쇄효과의 비교 (COMPARISON OF THE INFLUENCE OF CANAL CURVATURE ON THE SEALING ABILITY OF LATERAL CONDENSATION AND SYSTEM BTM)

  • 임동열;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제24권3호
    • /
    • pp.482-489
    • /
    • 1999
  • The purpose of this study was to compare sealing ability between lateral condensation and continuous wave of condensation in depend of root canal curvature. In this study, we divided fifty-six human molar teeth into two group in depend of Schneider method, and then subdivided them into four experimental group (each group is composed of twelve teeth) by canal curvature and obturation method, and eight teeth were served as positive and negative controls. Specimens were prepared by Quantac 2000 series file and obturated by lateral condensation or System B. Specimens were immersed in india ink for 7 days, decalcified by 10% nitric acid, dehydrated by 75, 95 and 100% alcohol in order, cleared by methyl salicylate and then measured of dye penetration with stereomicroscope(${\times}6.5$ magnification) and Image Pro plus. The data were analyzed stastically by one-way ANOVA and Scheffe test. The data were as follows: 1. The mean leakage was $0.725{\pm}1.167$ for group A, $0.813{\pm}0.921$ for group B, $0.809{\pm}0.997$ for group C, $1.111{\pm}1.147$ for group D, but no significant difference among them(p>0.05). 2. Lateral condensation had better sealing ability than continuous wave of condensation, but no significant difference among them(p>0.05). 3. There was no significant difference between root canal curvature degree and microleakage(p>0.05).

  • PDF

구치부 복합레진의 변연누출에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON THE MARGINAL LEAKAGE OF THE POSTERIOR COMPOSITE RESTORATIONS)

  • 권병구;이정석;박동수;이승종;이찬영
    • Restorative Dentistry and Endodontics
    • /
    • 제15권1호
    • /
    • pp.44-56
    • /
    • 1990
  • This study was designed to assess the degree of the marginal leakage of posterior composite restorations with glass ionomer cement base and Scotchbond$^{(R)}$ by means of the dye penetration at the enamel and dentinal margins. 160 cavities of class V were prepared on the buccal and lingual surfaces of 80 extracted premolar and molar teeth, which were divided into two groups. The buccal cavities of one group were filled with GC lining cement$^{(R)}$, Scotchbond$^{(R)}$ and P 50$^{(R)}$ and the lingual cavities were filled with Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$. The Buccal cavities of other group were filled with Logobond$^{(R)}$, Scotchbond$^{(R)}$ and Heliomolar$^{(R)}$ and lingual cavities were filled with Scotchbond$^{(R)}$ and P 50$^{(R)}$. After finishing, all specimens were subjected manually to 50 thermal cycles at $4^{\circ}C$ and $60^{\circ}C$. They were immersed in 0.5% methylene blue solution for 24 hours and buccolingually sectioned with diamond disc. The sectioned specimens were examined under light microscope. The following results were obtained. 1. The group filled with glass ionomer cement base showed less marginal leakage than the group filled without glass ionomer cement base. 2. The enamel margins showed less microleakage than the dentinal margins in both of the two groups. 3. No significant difference was showed in the microleakage, irrespective of two glass ionomer cement base and posterior composite resin.

  • PDF

광중합형 레진에서 초기 저광도 광중합 및 연마 시기가 변연부 미세 누출에 미치는 영향 (INFLUENCE OF LOW-INTENSITY CURING AND POLISHING PERIOD ON MARGINAL LEAKAGE OF COMPOSITE)

  • 이상훈;정일영;노병덕
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.85-90
    • /
    • 2000
  • For more esthetic treatments the use of composite in molar areas are increasing. But polymerzation shrinkage that cause marginal leakage and cuspal deflection has been the problems of composites. The purpose of this study is to compare the effect of low intensity curing and polishing period on marginal leakage. Cavities were prepared on the buccal or lingual surface of forty five sound extracted human teeth and etching, application of bonding agent and filling of composite was done. Group 1 was light cured at intensity of 600$mW/cm^2$ for 41 seconds and polished. Group 2 was light cured at intensity of 300$mW/cm^2$ for 2 seconds and polished and after polishing it was light cured for 40 seconds at 600$mW/cm^2$. Group 3 was light cured at intensity of 300$mW/cm^2$ for 2 seconds and waited for 5 minutes and after curing at 600$mW/cm^2$ for 40 seconds polishing was done. The specimens were thermocycled at $5^{\circ}C$ and $55^{\circ}C$ for 1000 cycles and immersed in 2% methylene blue solution for 24 hours. Composite-tooth interface was examined under stereobinocular microscope for dye penetration. The results were as follows : 1. Group which were cured at low intensity and polished after curing at high intensity showed less marginal leakage than group which were cured at high intensity for 41 seconds(p<0.05). 2. Marginal leakage between group which were cured at low intensity and polished immediately and group which were cured at high intensity for 41 second were not significantly different. Light curing at low intensity can reduce marginal leakage but polishing immediately after curing at low intensity for short time can affect marginal leakage.

  • PDF

쐐기 형태의 5급와동에서 수복재료에 따른 변연 미세누출의 비교 (COMPARISON OF MARGINAL LEAKAGE OF WEDGE-SHAPED CLASS V CAVITY ACCORDING TO RESTORATIVE MATERIALS)

  • 장현주;이희주;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제25권1호
    • /
    • pp.56-62
    • /
    • 2000
  • The purpose of this study was to assess the effects of restorative materials on the marginal leakage of wedge-shaped class V cavity. The study was performed in vitro in 25 defect-free permanent, extracted teeth. Wedge-shaped class V cavities were prepared and then the teeth were randomly selected and restored according to the following. Group A : restoration with Tetric Ceram(composite resin) Group B : restoration with Tetric flow(flowable resin) Group C : restoration with Compoglass after acid etching(compomer) Group D : restoration with Compoglass(compomer) Group E : restoration with Fuji II LC improved(resin-modified GIC) After thermocycling, the specimens were immersed in 5% basic fuchsin solution for 6 hours and sectioned longitudinally through the center of the restoration. The degree of marginal leakage was measured as the extent of dye penetration under the stereomicroscope. The data were analysed using one-way ANOVA. When significant differences found, multiple comparisons were made using Duncan's Multiple Range Test. The results were as follows: 1. The occlusal margins of all groups except for Fuji II LC improved showed lesser leakage than gingival margins and there was statistically significant difference(p<0.05). 2. At the occlusal margins, group A, B showed same marginal leakage scores, and others were decreased as group C, D, E in that order. There were statistically significant difference between group A, Band group D, E, group C and group E(p<0.05). 3. At the gingival margins, group B, C showed same marginal leakage scores, and others were decreased as group A, D, E in that order. But there was statistically significant difference between group B, C and group E(p<0.05). 4. In the Compoglass restoration, acid-etching technique was beneficial for marginal sealing ability at all of margins. But there was no statistically significant difference (p>0.05). In the restorations for wedge-shaped class V cavities, resin restoration with acid etching technique is recommended.

  • PDF

치근 우식 수복에 사용되는 심미성 수복물의 변연누출에 관한 연구 (A STUDY ON THE MARGINAL LEAKAGE OF ESTHETIC RESTORATIVE MATERIALS ON ROOT CARIES RESTORATION)

  • 한진순;임미경
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.205-213
    • /
    • 1993
  • The purpose of the study was to evaluate the degree of the marginal leakage of esthetic restorative materials on root caries restoration. 120 cavities were prepared to $90^{\circ}$ butt joint on all margins on the crown and root portion, and divided into 4 groups. The four groups of cavity were filled with Amalgam(Dongmuyung Dental Alloy Co., Ltd, KOREA), Silux$^{(R)}$(3M Co., USA)-Scotch Bond 2$^{(R)}$(3M Co., USA), Silux$^{(R)}$-All Bond$^{(R)}$(BISCO USA), and GC Fuji II$^{(R)}$(G-C Co., JAPAN) respectively. The apical margin of the preparation was finished to leave a flash of restorative material. The coronal margin of the preparation was finished not to leave a flash of restorative material. All specimens were sectioned longitudinally with Isomet Low speed saw(Buether Ltd, USA). The degree of dye penetration was evaluated as the parameter of marginal leakage under the stereoscope. The results were as follows. 1. At the enamel and dentin/cementum margins, the margin were finished to leave a flash of material showed less marginal leakage than that were finished not to leave a flash of material (P<0.001). 2. The enamel margins showed less marginal leakage than the dentin/cementum margins(P<0.001). 3. There was no significant difference in the degree of the marginal leakage between Silux$^{(R)}$-Scotch Bond 2$^{(R)}$ group and Silux$^{(R)}$-All Bond$^{(R)}$ group.

  • PDF

Glass Ionomer Root Canal Sealer의 치근단 미세누출에 관한 연구 (A STUDY ON THE APICAL MICROLEAKAGE OF GLASS IONOMER ROOT CANAL SEALER)

  • 이소영;홍찬의
    • Restorative Dentistry and Endodontics
    • /
    • 제23권1호
    • /
    • pp.236-246
    • /
    • 1998
  • The purpose of this study was to compare the degree of micro- leakage of new glass ionomer root canal sealer, Ketac-Endo(ESPE Co., Seefeld, Germany) with that of AH-26(De Trey Co., Ltd., U.S.A.). Root canal treatment using K -file, H -file, Gate Glidden drill was conducted on 49 extracted single-rooted teeth. 45 teeth were randomly divided into 3 experimental groups(15 teeth per group) and 4 teeth were used as the control group. Group 1 was used AH -26 sealer with the lateral condensation method for canal filling, group 2 was used Ketac-Endo with the single cone method and group 3 was used Ketac-Endo with the lateral condensation method. The control group was obturated with the single cone method without sealer. The teeth were covered with two coats of nail varnish after 48 hours of obturation. The teeth were immersed in India ink for 1 week and cleaned with methyl salicylate and then the degree of dye penetration were measured with stereomicroscope. The data were analyzed statistically by one-way ANOVA. The results were as follows: 1. 7 teeth in group 1, 5 in group 2, and 3 in group 3, were showed evidence of microleakage implying appropriate canal filling. 2, The mean average of microleakage was $0.17{\pm}0.32mm$ in group 1, $0.30{\pm}0.37mm$ in group 2. $0.10{\pm}0.21mm$ in group 3, showing that canal filling using the lateral condensation canal filling method with Ketac-Endo showed the least microleakage and using the single cone method with Ketac-Endo showed the largest amount of microleakage, 3. There were no statistically significant difference in the variation of microleakage among groups. From the results above, Ketac-Endo which has the advantage of glass ionomer, whether using the single cone method or the lateral condensation method, showed similar results as AH-26, but for clinical application it is thought that were studies on the properties of Ketac-Endo should be followed.

  • PDF

인산농도에 따른 치질의 미세누출 효과 (EFFECT OF CONCENTRATION OF PHOSPHORIC ACID ON MICROLEAKAGE TO TOOTH STRUCTURE)

  • 김병태;조영곤;문주훈
    • Restorative Dentistry and Endodontics
    • /
    • 제21권2호
    • /
    • pp.559-568
    • /
    • 1996
  • The purpose of this study was to evaluate the micro leakage of composite resin when various phosphoric acid agents were used to etch the enamel and dentin. In this study, class V cavities were prepared on the buccal surfaces of fourty extracted human molar teeth, and they were randomly assigned into 4 groups with 10 teeth. The cavities of each groups were etched with 10%, 32%, 35% and 37% phosphoric acids for 15 seconds, washed and dried and the cavities were restored with composite resin after application of the adhesive. The specimens were immersed in 2% methylene blue solution for 3 days. And then, the specimens were sectioned buccoligually. Degree of dye penetration at tooth-restoration interfaces was examined by Inverted Metallurgical Microscope at the occlusal and gingival margins. The result were as follows : 1. The degree of microleakage at occlusal and gingival margin in all group was statistically difference among 10% and 35% (P<0.01), 10% and 37% (P<0.01), 32% and 35% (P<0.05) and 32% and 37% (P<0.05) acid concentrations, but was not statistically difference between 10% and 32%, 35% and 37% acid concentrations (P>0.05). The degree of microleakage was showed to dimish with increase of acid concentration. 2. The degree of microleakage at the occlusal margin was statistically significant difference among 10% and 32%,10% and 35%, 10% and 37% acid concentrations(P<0.05). The degree of microleakage among 32% and 35%, 32% and 37% and 32% and 37% acid concentrations was not statistically significant difference. 3. In comparison of microleakage at the gingival margin, the degree of microleakage above 32% acid concentration was not showed less than 10% acid concentration (P>0.05). In comparison of 32%, 35%, 37% acid concentrations, the degree of microleakage at 35% and 37% acid concentrations was showed less than 32% acid concentration(P<0.05).

  • PDF

VALIDATION AND UTILIZATION OF THE SKINTEXTM SYSTEM

  • Gordon, V.C.;Realica, B.;Tolstrup, K.;Puls, B.
    • 대한화장품학회지
    • /
    • 제17권1호
    • /
    • pp.64-80
    • /
    • 1991
  • The SKINTEX Method is based on a two-compartment physico-chemical model which includes a Biomembrane Barrier in compartment one and an organized macromolecular matrix in compartment two. Test samples absorb onto or permeate through the keratin/collagen Biomembrane Barrier and then can interact with the organized macromolecular matrix. Changes in the integrity of the barrier release a dye indicator: Changes in the matrix can alter its transparency. The sum of these two responses is read spectrophotometrically at 470nm. An early investigation of 950 chemicals and formulations in the SKINTEX System produced results which were 89% concordance to in vivo Draize dermal irritation results obtained with 24-hour occluded application of test samples with-out abrasion and standard scoring. Alkaline materials were analyzed in a specialized SKINTEX AMA Protocol. In this early study, the model did not distinguish nonirritant test materials and formulation with PDII(Primary Dermal Irritation Index)in the range from 0 to 1.2, A High Sensitivity Assay Protocol(HSA)was developed to amplify the changes in both compartments of this model and provide more accurate calibration of these changes. A study of 60 low irritation test samples including cosmetics, household products, chemicals and petro-chemicals distinguished nonirritants with PDII $\leq$ 0.7 for 26 of 30 nonirritants. A second protocol was developed to evaluate the SKINTEX model predictability with respect to human irritation. The Human Response Assay (HRA )has been optimized based on differences in penetration and irritation responses in humans and rabbits. An additional 32 test materials with different mechanisms and degrees of dermal toxicity were evaluated by the HRA. These in vitro results were 86% concordant to human patch test results. In order to further evaluate this model, a Standard Chemical Labelling (SCL) Protocol was developed to optimize this system to predict Draize dermal irritation results after a 4-hour application of the test material. In a study of 52 chemicals including acids, bases, solvents, salts, surfactants and preservatives, the SCL results demonstrated 85% concordance to Draize results for a 4-hour application of test samples on non-abraded rabbit skin. The SKINTEX System, including three specialized protocols, provided results which demonstrated good correlation to the endpoint of dermal irritation in man and rabbits at different application times.

  • PDF

Evaluation of Shear Bond Strength and Microleakage of Self-adhesive Giomer

  • Gwangsuk Kim;Juhyun Lee;Haeni Kim;Howon Park
    • 대한소아치과학회지
    • /
    • 제50권4호
    • /
    • pp.434-442
    • /
    • 2023
  • This study was aimed to evaluate the bonding performance of a self-adhesive giomer and compare it to a conventional flowable composite resin with regard to shear bond strength and microleakage in enamel and dentin. Healthy human premolars extracted for orthodontic treatments were used in the study. For shear bond strength tests, enamel and dentin specimens were prepared for the study group with self-adhesive giomer and for the control group with conventional flowable composite resin with a 5th-generation adhesive system. A universal testing machine was used to measure the shear bond strength. For the microleakage tests, specimens were immersed in a 2% methylene blue solution for 24 hours, cut into sections, and evaluated with a stereomicroscope for the extent of dye penetration. The results of the study showed no statistically significant difference in shear bond strength between the self-adhesive giomer and the conventional flowable composite resin in enamel (p = 0.091). On the contrary, in dentin, the self-adhesive giomer showed significantly lower shear bond strength (p < 0.0001). The microleakage of the self-adhesive giomer was significantly higher than that of the conventional flowable composite resin (p = 0.002). Self-adhesive giomer is considered useful for restoring small cavities at the enamel level of pediatric patients by reducing chair time with the advantage of a simple bonding process. However, as the study was conducted in a laboratory setting, further research in a clinical environment is deemed necessary.

Bulk-fill과 Conventional 복합레진의 물성비교 (Comparison of Mechanical Properties between Bulk-fill and Conventional Composite Resin)

  • 석유정;김종빈;김기섭;김종수
    • 대한소아치과학회지
    • /
    • 제43권4호
    • /
    • pp.427-434
    • /
    • 2016
  • 본 연구에서는 최근 개발된 교합면 수복용 bulk-fill resin인 Filtek Bulk Fill Posterior Restorative (FBF)와 $Tetric^{(R)}$-N-Ceram Bulk Fill (TBF)의 물성을 기존 복합레진($Filtek^{TM}$ Z-350 XT, 이하 Z-350)과 비교하여 그 효용성을 평가하고자 하였다. 재료의 중합도를 반영할 수 있는 미세경도 및 중합수축을 반영하는 미세누출 양을 염료침투실험으로 측정하였다. 실험오차를 줄이기 위하여 정형화 된 3D 프린팅 몰드에 충전하여 미세경도를 측정하고, 우치를 대상으로 미세누출을 평가하였다. 측정된 미세경도와 미세누출정도는 Kruskal-Wallis test와 Mann-Whitney test를 이용하여 95%의 신뢰도로 각 군별 유의성을 평가하였다. 하면 미세경도에서 광중합 시행 1시간 이내에는 FBF와 TBF가 Z-350에 비해 유의하게 낮은 미세경도를 보였으나(p < 0.05), 24시간 후에는 FBF의 미세경도가 Z-350과 유의한 차이를 보이지 않을 만큼 현저히 증가하였다(p > 0.05). 하면을 제외한 미세경도는 Z-350, FBF, TBF 순으로 유의한 차이를 보였으며(p < 0.05) 미세누출실험에서는 TBF가 다른 두 군에 비해 유의하게 작은 미세누출을 보였다(p < 0.05). Bulk-fill 레진의 임상적 적용을 위해서는 중합 역학의 특성 상 수복 후 24시간 동안 저작력에 대한 주의가 필요하며 미세누출량을 감소시키기 위한 추가적 연구가 필요할 것으로 사료된다.