• Title/Summary/Keyword: Duty control rate

Search Result 91, Processing Time 0.019 seconds

Design of CMOS Optical Link Receiver for FTTH (FTTH용 CMOS Optical Link Receiver의 설계)

  • Kim Kyu-Chull
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.1
    • /
    • pp.47-52
    • /
    • 2004
  • This paper presents a CMOS optical receiver design featuring wide input dynamic range and low bit error rate suitable for FTTH application. We achieved 60dB input dynamic range for up to 100Mbps by controlling the PMOS feedback resistance of transimpedance preamplifier according to its output signal level. Auto-bias circuit is designed in current mirror configuration to minimize duty error. Circuit simulation has been performed using 2-poly, 3-metal, 0.6um CMOS process parameters. The designed receiver consumes less than 130mW at 100Mbps with 5V power supply.

Battery Cell Balancing with Hybrid Architecture of Serial and Parallel Charging (직·병렬 하이브리드 충전 구조를 사용한 배터리 균형 충전)

  • Jeong, Euihan;Yang, Changju;Han, Seungho;Kim, Hyongsuk
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.2 no.4
    • /
    • pp.609-613
    • /
    • 2016
  • A hybrid charging method with serial and parallel architecture has been developed to resolve the unbalanced charge problem among battery cells for Electric Vehicles. In this method, the major charging is performed with serial part and the balancing is carried out with the parallel part, where the serial part is big and heavy but the parallel part is smaller and lighter than serial part. A sensor array to detect the individual battery cell voltage, duty rate control incorporated IGBTs, and battery management system are employed as the core parts of the proposed system.

Character of Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터의 특성)

  • Mun, Sang-Pil;Kim, Chil-Ryong;Kwak, Dong-Kurl;Kim, Choon-Sam;Nakaoka, Mutsuo
    • Proceedings of the KIPE Conference
    • /
    • 2007.11a
    • /
    • pp.133-135
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Soft Switching High Frequency Inverter for New Induction Heating (새로운 유도가열용 소프트 스위칭 고주파 인버터)

  • Kim, C.Y.;Mun, S.P.;Kim, M.Y.;Kim, H.J.;Lyu, J.Y.;Kim, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.119-124
    • /
    • 2007
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Pull)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Induction Heating ZCS PWM SEPP High Frequency Inverter (유도가열용 ZCS PWM SEPP 고주파 인버터)

  • Mun, Sang-Pil;Gwon, Sun-Geol;Lee, Jong-Geol;Ju, Seok-Min;Gang, Sin-Chul
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.241-243
    • /
    • 2008
  • This research presented the new zero-current switching pulse width modulation SEPP(Single Ended Push-Full)high frequency inverter for solving the problem of the zero-current SEPP high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the zero-current switching pulse width modulation SEPP high frequency inverter. The inverter circuit which is attempted by on-off operation of a switch has the reduction effect of the power loss due to a soft switching and a high frequency switching. And it confirmed that the power regulation is possible continuously from 0.25[kW] until 2.84[kW] in the case the duty rate(D) changes from 0.08 to 0.3 under zero-current switching operating by a dissymmetry pulse width modulating control and the power conversion efficiency comes true the efficiency of 95[%]. Due to the result above, the ZCS PWM SEPP high frequency inverter will be effective as sources of an induction heating apparatus.

  • PDF

Characteristics Evaluation of Moving Picture Blur Noise for Liquid Crystal Display (액정 디스플레이의 동화상 퍼짐 노이즈 특성 평가)

  • Ryeom, Jeong-Duk
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.1
    • /
    • pp.27-35
    • /
    • 2009
  • The moving picture blur noise of LCD is measured and the characteristics of it are evaluated. From the results, blur noise is generated only when the sight line moves while pursuing the moving image and blur noise is not generated when the sight line is fixed. In addition, decrease of gray level by the image blur has a linearity and velocity dependence. The blur noise simulator based on this experimental results is developed. From the results of blur noise simulation, the faster the moving speed of image is, the more blur noise has increased and these agree with the results of measurement. In the result of simulating blur noise characteristics by the duty ratio control of backlight, noise is reduced by lowering of the duty ratio. but the blur noise increases if there is in the both of adjacent two frames. Moreover, the case of doubling the frame rate to 120[Hz], decreasing the moving speed of the image by making an new image between the adjacent two frames brings the reduction of blur noise.

Low Power MAC Protocol Design for Wireless Sensor Networks using Recursive Estimation Methods (회귀적 추정 방식을 이용한 무선 센서 네트워크용 저전력 MAC 프로토콜)

  • Pak, Wooguil
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39C no.3
    • /
    • pp.239-246
    • /
    • 2014
  • In the context of wireless sensor networks, one of major issues is energy conservation. For low power communication, by utilizing our experimental results for the relation between clock drift and synchronization interval, we designed a new protocol which can support a wide range of duty cycles for applications with very low traffic rate and insensitive delay. The transmission (TX) node in the protocol synchronizes with the reception (RX) node very before transmitting a packet, and it can adaptively estimate the synchronization error size according to the synchronization interval from minutes to hours. We conducted simulations and a testbed implementation to show the efficacy of the proposed protocol. We found that our protocol substantially outperforms other state-of-the-art protocols, resulting in order-of-magnitude increase in network lifetime over a variety of duty cycles.

Chopper Application for Magnetic Stimulation

  • Choi, Sun-Seob;Lee, Sun-Min;Kim, Jun-Hyoung;Kim, Whi-Young
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.213-220
    • /
    • 2010
  • Since the hypothalamus immediately reacts to a nerve by processing all the information from the human body and the external stimulus being conducted, it performs a significant role in internal secretion; thus, a diverse and rapid stimulus pulse is required. By detecting Zero Detector accurately via the application of AVR on-Chip (ATMEL) using commercial electricity, chopping generates a stimulus pulse to the brain using an IGBT gate to designate a new magnetic stimulation following treatment and diagnosis. To simplify and generate a diverse range of stimuli for the brain, chopping can be used as a free magnetic stimulator. Then, commercial frequency (60Hz) is chopped precisely at the first level of the leakage transformer to deliver an appropriate stimulus pulse towards the hypothalamus when necessary. Discharge becomes stable, and the chopping frequency and duty-ratio provide variety after authorizing a high-pressure chopping voltage at the second level of the magnetic stimulator. These methods have several aims. The first is to apply a variable stimulus pulse via accurate switching frequency control by a voltaic pulse or a pulse repetition rate, according to the diagnostic purpose for a given hypothalamus. Consequently, the efficiency tends to increase. This experiment was conducted at a maximum of 210 W, a magnetic induced amplitude of 0.1~2.5 Tesla, a pulse duration of $200{\sim}350\;{\mu}s$, magnetic inducement of 5 Hz, stimulus frequency of 0.1~60 Hz, and a duration of stimulus train of 1~10 sec.

A study on the status of working environment control and health management of workers in a manufacturing industries (일부 제조업 사업장의 작업환경 및 보건관리 실태)

  • Ham, Jung-O;Hwang, Kyu-Yoon;Ahn, Kyu-Dong;Lee, Byung-Kook;Nam, Tack-Sung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.275-284
    • /
    • 1990
  • To obtain the useful information for the status of working environment and health management of workers in manufacturing industries, comparision of results on the status of working environmental and health management of workers for 32 manufacturing industries in Chunan area from 1988 to 1989 was carried out. The results were as follows : 1. The rate of over-PEL (Permissible Exposure Limit) to for hazardous factors decreased significantly 23.5% in 1988, 18.3% in 1989 (p<0.05) and, the highest rate of over-PEL was the stone and sand handling industry, the highest rate of over-PEL was the dusty workplace as 38.5% in 1988, 35.2% in 1989. 2. The rate of workers exposed to hazardous factors in 1988 and in 1989 was 22.4% respectively, the rate of workers checked up special health examination was 40.1% in 1988, 75.3% in 1989. In stone and sand handling and medicochemical industries, none of workers exposed to hazardous factors was subjected to special health examination in 1988, but 75% of workers exposed to hazardous factors had checked up in 1989. 3. The 6 industries appointed as part-time factory physician among 17 industries which were supposed to have factory physician according to the Safety and Healthy Act of Korea, 6 out of 24 industries only appointed industrial hygienist, furthermore 4 out of 6 hygienists had another duty in addition to occupational hygiene itself.

  • PDF

A study on the haromnic attenuation of the BF Converter (BF 컨버터의 고조파 감쇠에 관한 연구)

  • 최태섭;안인수;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.4
    • /
    • pp.8-15
    • /
    • 2000
  • In this paper, we realize the active PFC(Power Factor Correction) system of BF(Boost Forward) converter with PWM-PFM(Pulse Width Modulation-Pulse Frequency Modulation) control technique to control DC output voltage, to remove the noise like harmonics at output voltage, and to control the input current with sinusoidal wave synchronized by the source voltage.To achieve the desired load voltage and improved PFC, we first implement current shaping control at the inverting stage and make the converted output DC voltage with forward converter. After making the ratio of output voltage to current as 50V/1A and the duty ratio greater than 0.5. When input voltage is 30V and boost inductance is 1.1mH. we control the voltage changing rate according to the variation of load resistance using a PWM-PFM control technique. And finally we prove experimentally, we attenuated its harmonics and improved PF up to 0.96 using the current shaping technique.

  • PDF