• Title/Summary/Keyword: Dust reduction

Search Result 278, Processing Time 0.031 seconds

The Development of Cable Carrier Chain System with Low Noise and Dust for Moving Stages in Cleanrooms using TRIZ (TRIZ를 활용한 클린룸용 저소음 및 저분진 케이블 이송 체인 시스템의 개발)

  • Kim, Du-Jin;Hyun, Dong-Hoon;Kim, Young-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.83-88
    • /
    • 2009
  • In this paper TRIZ was used to solve noise and dust reduction related to cable carrier chain system. On modern machines in a clean room, the contradictions arose due to increase noise and dust for the high speed were eliminated with 40 principles and seperation rules. As the results, the sound pressure level of the new carrier chain system was reduced to below 40 dB(A), and cleanroom classifications was satisfied with ISO class 4. In these successful results, TRIZ showed its usefulness in solving the design problems even with severe constraints.

  • PDF

Reflectance Spectrum of Main Belt Asteroid P/2010 A2

  • Kim, Jun-Han;Ishiguro, Masateru;Hanayama, Hidekazu
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.41.2-41.2
    • /
    • 2011
  • P/2010 A2, a main-belt asteroid having comet-like dust trail was discovered in January 2010, but the origin of the trail is controversial. Moreno et al. (2010) reported water-ice sublimation as a mechanism for the comet-like activity, whereas other researches (Jewitt et al. 2010; Snodgrass et al. 2010) stated that impact collision contributed to the dust trail. For asteroids are categorized based on spectral shape, optical observation using different color filters makes it possible to determine the taxonomic type of P/2010 A2 nucleus, thus gives an answer to the question of activation mechanism of the object. In this presentation, we report multiband observation of P/2010 A2 in January and March 2010 with 1-meter telescope of Ishigaki-Jima Astronomical Observatory. We employed three broadband filters of g', Rc, and Ic. In this presentation, we focus on the data acquisition, the reduction and the derivation of the reflectance spectrum of debris in the trail. Finally we discuss the potential cause of dust ejection from this asteroid.

  • PDF

Purification on the Leaching Solution of the Crude Zinc Oxide Recovered from the Reduction of EAF Dust (전기로제강분진으로부터 환원휘발된 조산화아연의 침출용액 정액에 관한 연구)

  • Youn Ki-Byoung
    • Resources Recycling
    • /
    • v.13 no.1
    • /
    • pp.22-27
    • /
    • 2004
  • Purification on the leaching solution of the crude zinc oxide obtained by the reduction of EAF dust has been carried out. Pb and Cd ions in the leaching solution were precipitated and removed from the solution by the addition of zinc metal powder. The purification condition for electrowinning to obtain the high purity zinc metal was investigated by analyzing the effects of Pb and Cd ion concentrations on the contents of impurities in the recovered zinc metal. The 3 N purity zinc metal was obtained at the electrolysis condition of the concentrations of Pb less than 2 ppm and Cd less than 0.1 ppm in the purified solution. For this purification, the amounts of zinc metal powder more than 8.5 g/l should be added in the crude zinc oxide leached solution.

Development of the Experimental Apparatus to Measure a Pore Size of Micro-pore Fabrics Used for a Bedding to Block the House Dust Mite Allergen (집먼지 진드기 알레르겐 차단 침구에 사용되는 극세 공극 직물의 공극 측정을 위한 입자 투과 실험 장치의 개발)

  • Kim, Donhue
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.557-563
    • /
    • 2022
  • In order to measure the allergen penetration of micropore fabrics, it is necessary to develop a convenient and appropriate experimental method for measuring a pore size of micropore fabrics. In this study, a simple and economical experimental apparatus was developed for the analysis of the pore size of micropore fabrics by measuring the weight reduction rate. In addition, the allergen blocking properties was evaluated by measuring the pore sizes of various fabrics. According to this study, the size of the pores of the microporous fabric could be obtained by measuring the weight reduction rates. In addition, higher weight reduction rate was obtained as the suction pressure passing through the particle permeation device decreased and the suction time was increased. It is expected that the developed experimental method and apparatus can be utilized as an experimental standard for quality control methods to verify the effectiveness of micropore fabrics used for house dust mite blocking bedding.

Fine dust(PM10) emission calculated of Dong-Hae harbor around area using inverse modeling technique (역모델링 기법을 이용한 동해항 주변지역 미세먼지 배출량 산출)

  • Kim, Ji-Hyun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.649-660
    • /
    • 2015
  • Data obtained from the Calpuff inverse modeling estimate the emission amount of pollutants, and enable to establish the aim for reduction through the comparison of various cases. This study pursued to accumulate the fundamental data by the Calpuff inverse modeling for five areas in the vicinity of Donghae harbor, which focused on reduction of atmospheric fine dust. As a result of evaluation of the allowed emission amount for local sites, site-D required the most reduction, $4.95{\mu}g/m^2{\cdot}S$, based on the atmospheric guideline, $50{\mu}g/m^3$. The theoretical mitigation could decrease the average concentration of PM10 to $42.6{\mu}g/m^3$ for the study field (Donghae waste water treatment plant). Modeling only for site-A emission showed the potential concentration around the residential area of Donghae harbor, $40{\sim}50{\mu}g/m^3$. However, it will rise over $50{\mu}g/m^3$ with the addition of background level. Therefore no more emission would be allowed. Site-B including commercial area and unpaved field required the reduction of $0.11{\mu}g/m^2{\cdot}S$ due to vehicles and fugitive dust. Site-C and E did not emit additional pollutants.

Evaluation of Performance and Maintenance Cost for Roadside's Particulate Matter Reduction Devices Using Smart Green Infrastructure Technology (스마트 그린인프라 기술을 활용한 도로변 미세먼지 저감장치의 성능 및 유지·관리 비용 평가)

  • Song, Kyu-Sung;Seok, Young-Sun;Yim, Hyo-Sook;Chon, Jin-Hyung
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.25 no.4
    • /
    • pp.15-31
    • /
    • 2022
  • The Green Purification Unit System (GPUS) is a green infrastructure facility applicable to the roadside to reduce particulate matter from road traffic. This study introduces two types of GPUS (type1 and type2) and assesses the performance and maintenance costs of each of them. The GPUS's performance analysis used the data collected in November 2021 after the installation of the GPUS type1 and type2 at the study site in Suwon. The changes in the particulate matter concentration near the GPUS were measured. The maintenance cost of GPUS type1 and type2 was assessed by calculating the initial installation cost and the management and repair cost after installation. The results of the performance analysis showed that the GPUS type1, which was manufactured by combining plants and electric dust collectors, had a superior particulate matter reduction performance. In particular, type1 produced a greater effect of particulate matter reduction in the time with a high concentration (50㎍/m3 or higher) of particulate matter due to the operation of electric dust collectors. GPUS type2, which was designed in the form of a plant wall without applying an electric dust collector, showed lower reduction performance than type1 but showed sufficiently improved performance compared to the existing band green area. Meanwhile, the GPUS type1 had three times higher costs for the initial installation than GPUS type2. In terms of costs for managing and repairing, it was evaluated that type1 would be slightly more costly than type2. Finally, this study discussed the applicability of two types of GPUS based on the result of the analysis of their particulate matter performance and maintenance cost at the same time. Since GPUS type2 has a cheaper cost than type1, it could be more economical. However, in the area suffering a high concentration of particulate matter, GPUS type1 would be more effective than type2. Therefore, the choice of GPUS types should rely on the status of particulate matter concentration in the area where GPUS is being installed.

AN EXPERIMENTAL STUDY ON THE EFFICIENCY OF A LOCAL VENTILATION SYSTEM AND THE PROTECTING FACE MASKS IN DENTAL LABORATORIES

  • Kim, Uoong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.11 no.1
    • /
    • pp.95-102
    • /
    • 1989
  • This study was performed to study the efficiency of a local ventilation system, installed in dental laboratories, and of two types of protecting face masks. The dust originating from the workpiece as well as from the wheels and stones was collected on air filters in the cutting cycle during coarse and fine grinding, and in the subsequent polishing procedures of each specific dental material. The efficiency of the ventilation system was measured on the basis of weight reduction of dust in the breathing air at a distance about 20-40 cm from workpiece. The results were as follows: 1. Use of the local ventilation system reduced the amounts of respirable dust to an average level of 21.4%, although the efficiency of the local ventilation system varied depending upon materials used. 2. Mounting a nozzle on the tube improved the efficiency of the ventilation system considerably. The efficiency of the local ventilation system also increased as the workpiece was closing to the tube inlet. 3. With or without the local ventilation system, the distance between the position of the workpiece and sampler greatly affected the dust level. 4. The face masks covering the sampler improved the efficiency of the ventilation system considerably.

  • PDF

Efficacy of Half Dose House Dust Mites-Specific Immunotherapy on Canine Atopic Dermatitis

  • Park, Jeong-Ho;Lee, Wang-Hui;Park, Seong-Jun
    • Journal of Veterinary Clinics
    • /
    • v.34 no.1
    • /
    • pp.18-22
    • /
    • 2017
  • The aim of this study was to prove that the hypothesis of half dose (HD) allergen-specific immunotherapy (ASIT) in the treatment of canine atopic dermatitis (CAD) would result in a similar success rate compared to the standard dose (SD) ASIT. Clinical signs were evaluated using a third version of the Canine Atopic Dermatitis Extent and Severity Index (CADESI-03) prior to ASIT (day 0), at the end of induction (day 43), and at three month afterwards (day 90). Of the 18 atopic dogs, 12 dogs (SD group: 6; HD group: 6) had a good - excellent response to the house dust mites-specific immunotherapy. The efficacies of ASIT were 66.6% in both groups. The grades of reduction rate CADESI-03 were not different between two groups. Therefore, half dose protocol of house dust mites-specific immunotherapy is an effective and efficient method to treat CAD.

Development of the Dual Cyclone System for a High Efficient Vacuum Cleaner (사이클론 집진 원리를 적용한 진공청소기 개발에 관한 연구)

  • Lee, Jae-Keun;Lee, Jung-Eun;Kim, Seong-Chan;Cho, Min-Chul;Hyun, Choong-Nam;Kwack, Dong-Jin;Lim, Kyung-Suk;Lee, Sung-Hwa;Yang, Byung-Sun;Ji, Heon-Pyung;Jeong, Hoi-Kil;Park, Deog-Bae;Liu, Benjamin Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.644-649
    • /
    • 2000
  • A new cyclone system for the vacuum cleaner to collect dusts has been studied experimentally and numerically to meet the constant suction power, hygienic exhaust and a reduction of maintenance cost. The cyclone system of the vacuum cleaner consists of twin cyclones for improving dust collection efficiency. The first. cyclone catches large dust particles and the second one having two separated flows to decrease pressure drop collects small dust particles. The optimal design factors such as dust collection efficiency, pressure drop, and cut-size are investigated from the experimental results by the Taguchi method. Cyclone cleaner systems designed in this study has a good Performance taking into account the dust collection efficiency of 93% and the cut-size of $1.6{\mu}m$ in mass median diameter at the flow rate of 1 CMM. The cyclone vacuum cleaner showed the potential to be an effective method to collect dusts generated in the household.

  • PDF

A Study on Making of High-Purity Ferro-manganese from $Mn_3O_4$ Waste Dust ($Mn_3O_4$ 분진으로부터 고순도 훼로망간 제조에 관한 연구)

  • Kim, Youn-Che;Song, Young-Jun;Park, Young-Koo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.2
    • /
    • pp.135-139
    • /
    • 2011
  • In order to make high-purity ferro-manganese from $Mn_3O_4$ waste dust, the application of aluminothermite process to the reduction of the waste dust was investigated. The mixture from $Mn_3O_4$ dust as metallic source and Al metal powder as the reductant ignited, and reduced with an extremely intense exothermic reaction. The rapid propagation of the aluminothermite reaction occurred spontaneously and stably by ignition of the mixture. The Manganese having some alloy elements emerged as liquids due to the high temperatures reached up to about $2,500^{\circ}C$ and separated from the liquid by their differences of specific gravity. The result of thermite reaction showed the fact that can be obtained high purity ferro-manganese which have over about 90% of manganese content and lower impurities such as C, P, S than those of KS D3712 specification. The recovery of manganese from $Mn_3O_4$ dust was lower level of about 65% than about 75% from manganese ore by electric furnace process, that is due to spatter loss because of its extremely intense thermite reaction. But it will be improved by the process designed to provide CaO as the cooler or to use the Al metal powder having larger particle size distribution.