• Title/Summary/Keyword: Dust particles

Search Result 496, Processing Time 0.027 seconds

The study of detonation of laser-ablated aluminum by high power laser (고 에너지 레이저를 통한 laser-ablated 알루미늄의 detonation 현상 연구)

  • Kim, Chang-Hwan;Yoh, Jack. J
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.425-429
    • /
    • 2011
  • The development of metal plasma generated by high laser irradiance and its effect on the surrounding air using shadowgraph images after laser pulse termination are studied; hence the formation of laser supported detonation and combustion processes has been investigated. The core of the paper is in detecting chemical reaction using X-Ray Diffraction (XRD) between ablated aluminum plasma and oxygen from air by inducing high power laser pulse (>1000 mJ/pulse) and conduct a quantitative comparison of chemically reactive laser initiated waves with the classical detonation of exploding aluminum (dust) cloud in air. This study may suggest a new approach of initiating detonation from metal sample in its bulk form without the need of mixing nano-particles with oxygen for initiation.

  • PDF

Examining the performance of PAI/ZnO synthesized with diamine and nano particles

  • Jianwei Shi;Xiaoxu Teng
    • Advances in nano research
    • /
    • v.14 no.2
    • /
    • pp.201-210
    • /
    • 2023
  • A ZnO/poly (amide-imide) hybrid nanocomposite film with different weight percentages of Zinc oxide (ZnO) nanoparticles is synthesized and characterized in this paper. A two-step reaction successfully synthesized a new kind of heteroaromatic diamine with bulky pendant groups. In order to produce 3, 5-dinitro-3, 3-bis (4-(4-Nitrophenoxy) phenyl) -2- benzofuran-1-one, 3, 3'-bis (4-hydroxyphenyl) benzofuran-1-one and 3'-bis (4-hydroxyphenyl) benzofuran-1-one were combined with 3'-bis (3-hydroxyphenyl) benzofuran-1-one. The obtained dinitro was then reduced by zinc dust and hydrochloric acid. The reaction of 4, 4* carbonyl diphthalic anhydride with amino acid L-alanine in acetic acid leads to the production of very high yields of chiral diacid monomer. As a result of the direct polymerization of these monomers, new optically active polymers were formed (amide-imide). In order to synthesize poly (amide-imide)/ZnO nanocomposites with different weight percentages (2, 4, 6, 8, and 10%), PAI and ZnO nanoparticles were combined using ultrasonication SEM, Fourier transform infrared spectroscopy, X-ray diffraction and thermal gravimetry were used to characterize the PAI films.

Pollution Characteristics of Hazardous Elements for Roadside Dust in Gwangju City, Korea (광주광역시 도로변 분진에 대한 유해원소의 오염특성)

  • Lee, Jang-Jon;Park, Young-Seog;Kim, Jong-Kyun;Han, Min-Su
    • Economic and Environmental Geology
    • /
    • v.40 no.3 s.184
    • /
    • pp.263-275
    • /
    • 2007
  • The purpose of this study was to show the pollution characteristics of hazardous elements from roadside dust in the Gwangju city. We collected 47 samples from November to December in 2004 and separated four groups such as residential area, industrialized area, downtown area and heavy traffic area fer characteristics comparison on hazardous elements. Roadside dust mostly consisted of quartz, albite, microcline, muscovite in XRD analysis. Content of hazardous elements varied: As $3.4{\sim}11.9 ppm$, Cd $0.2{\sim}28.2 ppm$, Co $32{\sim}526 ppm$, Cr $25{\sim}526 ppm$, Cu $11{\sim}375 ppm$, Ni $14{\sim}247 ppm$, Pb $13{\sim}413 ppm$ and Zn $101{\sim}972 ppm$. Average contents of hazardous elements of Zn>Cu>Pb>Cr>Co>Ni>Cd. Content of hazardous elements was low in residential area, whereas that of heavy metal was much the same in both in heavy traffic area. Content of hazardous elements such as Cd, Co, Cr, Cu, Ni, Pb, Zn was found to be particularly high in industrialized area. According to these results it was possible to presume that industrialized area was affected by industry activity such as machinery, petrochemical, automobile and electronics industry. The SEM analysis, detected Pb, Cr, Ni, and Fe particles in samples of industrialized area contaminated by industry activity. The correlation coefficient table resulted from the samples of roadside dust showed that there was same direction increase of content between elements. In other words, when the content of Cd increase, Cr and Ni increase, as Cr increase, Cu and Ni increase, as Cu increase Ni increase and Pb increase Zn increase. Based on these results it was possible to predict and interpret similar contamination patterns in this study.

Particulate Matter 10 from Asian Dust Storms Induces the Expression of Reactive Oxygen Species, NF-κ, TGF-β and Fibronectin in WI-26 VA4 Epithelial Cells (황사의 PM10이 WI-26 VA4 Cells에서 Reactive Oxygen Species, NFκB, TGF-β, Fibronectin의 발현에 미치는 영향)

  • Park, Kyeong Seon;Kim, Yu Jin;Yoon, Jin Young;Kyung, Sun Young;An, Chang Hyeok;Lee, Sang Pyo;Park, Jeong Woong;Jeong, Sung Hwan
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.6
    • /
    • pp.504-511
    • /
    • 2008
  • Background: Particulate matter may be toxic to human tissue. Ambient air particulate matter ${\leq}10{\mu}m$ in aerodynamic size ($PM_{10}$), which changes under different environmental conditions, is a complex mixture of organic and inorganic compounds. The Asian dust event caused by meteorological phenomena can also spread unique particulate matter in affected areas. We evaluated production of ROS, $TGF-{\beta}$, fibronectin, and $NF{\kappa}B$ by exposing normal epithelial cells to Asian dust particulate matter. Methods: Bronchial epithelial cells were exposed to 0, 50, ${\leq}100{\mu}g/ml$ of a suspension of $PM_{10}$ for 24 h. ROS were detected by measurement of DCF release from DCF-DA by FACScan. $TGF-{\beta}$, fibronectin, and $NF{\kappa}B$ were detected by western blotting. Results: $PM_{10}$ exposure increased the expression of $TGF-{\beta}$, fibronectin, and $NF{\kappa}B$. ROS production and $TGF-{\beta}$ levels were significantly higher with 50 or ${\leq}100{\mu}g/ml$ $PM_{10}$. Fibronectin and $NF{\kappa}B$ production were significantly higher after ${\leq}100{\mu}g/ml$ of $PM_{10}$. Conclusion: $PM_{10}$ from Asian dust particles might have fibrotic potential in bronchial epithelial cells via ROS induction after $PM_{10}$ exposure.

Characteristics of Metallic Elements Concentration of Fine Particles(PM10, PM2.5) at Busan in 2004 (2004년 부산지역 미세먼지(PM10, PM2.5) 중의 금속 농도 특성)

  • Jeon Byung-Il;Hwang Yong-Sik;Lee Hyeok-Woo;Yang Ah-Reum;Kim Hyun-Jung;Seol Jae-Hwan;Kang Young-Jin;Kim Taek-Hoon;Jang Hyun-Seok
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.573-583
    • /
    • 2005
  • [ $PM_{10}\;and\;PM_{2.5}$ ] aerosols were collected at Busan from March, 2004 to December, 2004, and the concentrations of some metal elements were chemically analyzed to study their characteristics. The mean concentration of $PM_{10}$ was $58.2{\mu}g/m^3$ with a range of 8.3 to $161.1{\mu}g/m^3$. The mean concentration of $PM_{2.5}$ was $29.3{\mu}g/m^3$ with a range of 2.8 to $65.3\mu}g/m^3$. The mean mass concentrations of Asian dust and non Asian dust in $PM_{10}$ were $121.5\mu}g/m^3$ and $56.0{\mu}g/,^3$ respectively. The mean values of crustal enrichment factors for six elements (Cd, Cr, Cu, Ni, Pb and Zn) were all higher than 10, possibly suggesting the influence of anthropogenic sources. The crustal enrichment factors of some heavy metal elements in non-Asian dust (NAD) were higher than those in Asian dust (AD), possibly due to anthropogenic emissions transported from industries around this area by westerly wind. The soil contribution ratios for $PM_{10}$ and $PM_{2.5}$ were $15.2\%$ and $17.5\%$ on the whole. and those of AD/NAD for $PM_{10}$ and $PM_{2.5}$ were 1.9 and 2.1, respectively.

A Study on the Resource Recovery of Fe-Clinker generated in the Recycling Process of Electric Arc Furnace Dust (전기로 제강분진의 재활용과정에서 발생되는 Fe-Clinker의 자원화에 관한 연구)

  • Jae-hong Yoon;Chi-hyun Yoon;Hirofumi Sugimoto;Akio Honjo
    • Resources Recycling
    • /
    • v.32 no.1
    • /
    • pp.50-59
    • /
    • 2023
  • The amount of dust generated during the dissolution of scrap in an electric arc furnace is approximately 1.5% of the scrap metal input, and it is primarily collected in a bag filter. Electric arc furnace dust primarily consists of zinc and ion. The processing of zinc starts with its conversion into pellet form by the addition of a carbon-based reducing agent(coke, anthracite) and limestone (C/S control). These pellets then undergo reduction, volatilization, and re-oxidation in rotary kiln or RHF reactor to recover crude zinc oxide (60%w/w). Next, iron is discharged from the electric arc furnace dust as a solid called Fe clinker (secondary by-product of the Fe-base). Several methods are then used to treat the Fe clinker, which vary depending on the country, including landfilling and recycling (e.g., subbase course material, aggregate for concrete, Fe-source for cement manufacturing). However, landfilling has several drawbacks, including environmental pollution due to leaching, high landfill costs, and wastage of iron resources. To improve Fe recovery in the clinker, we pulverized it into optimal -sized particles and employed specific gravity and magnetic force selection methods to isolate this metal. A carbon-based reducing agent and a binding material were added to the separated coarse powder (>10㎛) to prepare briquette clinker. A small amount (1-3%w/w) of the briquette clinker was charged with the scrap in an electric arc furnace to evaluate its feasibility as an additives (carbonaceous material, heat-generating material, and Fe source).

A Study on Livestock Odor Reduction Using Water Washing System (수세탈취시스템을 이용한 축산악취저감에 관한 연구)

  • Jeon, Kyoung-Ho;Choi, Dong-Yoon;Song, Jun-Ik;Park, Kyu-Hyun;Kim, Jae-Hwan;Kwag, Jung-Hoon;Kang, Hee-Sul;Jeong, Jong-Won
    • Journal of Animal Environmental Science
    • /
    • v.16 no.1
    • /
    • pp.21-28
    • /
    • 2010
  • The odor problem in the livestock is increasing by 7% annually. Most importantly, the livestock odor problem in swinery accounts for the maximum ratio (54%). In this study, we reviewed the possibility of deodorizing swinery using an odor reduction device that can be used with the water washing system. First, the study confirmed that the solubility of odor gas, which was hydrogen sulfide, was very low regardless of the contact time with solvent, but the solubility of methyl mercaptan was found to increase along with the increase in time. The solubility of other odor gases, such as dimethyl sulfide, dimethyl disulfide and ammonia, was considerably high. Consequently, it is considered that if the odor reduction device for the water washing system deodorization is used in a swinery, the time during which the exhaust gas is in contact with usable water must be extended, or solvent quantity must be expanded. However, it is predicted that although hydrogen sulfide is easily generated in the anaerobic condition, it is difficult to expect high odor reduction efficiency because this gas has low solubility in water, especially in case it is used in the deodorization of the water washing system. The result of the solubility experiment using the bench-scale device practically manufactured represented the higher odor reduction ratio than expected. This result was possible because the removal efficiency of dust particles could be reached up to 93%. Therefore, it is judged that also the odor gas absorbed on dust particles could be removed by removal of dust. Consequently, it is expected that the higher order reduction ratio will be possible by structural improvement for increasing contact with water and odor gas.

The development of the Ionizer using clean room (청정환경용 정전기 제거장치 개발)

  • Jeong, Jong-Hyeog;Woo, Dong Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.603-608
    • /
    • 2018
  • Although the voltage-applied discharge method is most widely used in the semiconductor and display industries, periodic management costs are incurred because the method causes defects due to the absorption of ambient fine dust and causes emitter tip contamination due to the discharge. The emitter tip contamination problem is caused by the accumulation of fine particles in ambient air due to the corona discharge of the ionizer. Fuzzy ball generation accelerates the wear of the emitter tip and deteriorates the performance of the ionizer. Although a mechanical cleaning method using a manual brush or an automatic brush is effective for contaminant removal, it requires management of additional mechanical parts by the user. In some cases, contaminants accumulated in the emitter may be transferred to the wafer or product. In order to solve this problem, we developed an ionizer for a clean environment that can remove the pencil-type emitter tip and directly ionize the surrounding gas molecules using the tungsten wire located inside the ion tank. As a result of testing and certification by the Korea Institute of Machinery and Materials, the average concentration was $0.7572particles/ft^3$, the decay time was less than two seconds, and the ion valance was 7.6 V, which is satisfactory.

Seasonal Changes in the Absorption of Particulate Matter and the Fine Structure of Street Trees in the Southern Areas, Korea: With a Reference to Quercus myrsinifolia, Quercus glauca, Quercus salicina, Camellia japonica, and Prunus × yedoensis (한국 남부지역 가로수종 잎 미세구조와 미세먼지 흡착량의 계절 변화: 가시나무, 종가시나무, 참가시나무, 동백나무, 왕벚나무 중심으로)

  • Jin, Eon-Ju;Yoon, Jun-Hyuck;Choi, Myung Suk;Sung, Chang-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.129-140
    • /
    • 2021
  • The study investigates the correlation between the seasonal changes in the absorption of fine dusts and the fine structure of surface on each type of street tree, such as Quercus myrsinifolia, Quercus glauca, Quercus salicina, Camellia japonica, and Prunus × yedoensis in the southernareas of Korea. The absorption ranges of fine dust were 31.51~110.44 ㎍/cm2 in January, 23.20~79.30 ㎍/cm2 in November, 22.68~76.90 ㎍/cm2 in May, and 9.88~49.91 ㎍/cm2 in August. The absorption value was about 54.4% higher in January than in May. With the grooves and hairs on the leaf surface and lots of wax, Q. salicina seems related to the high absorption rate of fine dust for each fine dust particle size. The one with gloss and smooth leaf surface has a low amount of wax. C. japonica Prunus × yedoensisshowed a low absorption rate of fine dust in each season. Whereas the increase in porosity density, length, and leaf area size can be related to the reduced PM and increasedabsorption rate, the leaf surface roughness, total wax amount, and porosity width can be related to the increase in the PM absorption rate. There was also a high correlation between the total wax amount and absorption rate of the leaf surface at the size of PM0.2 than PM10 and PM2.5. These results imply that the quantitative and qualitative trais of leaf, such as wax amounts and leaf surface,can increase the absorption of fine dusts, and the small-sized particles seem to be highly adsorbed with the high wax amounts.

Characteristics of Sawdust and Cocopeat Beddings, and Their Usefulness According to the Fan and Pen Location for Rearing Hanwoo Cattle

  • Ahn, Gyu Chul;Jang, Sun Sik;Lee, Kang Yeon;Kwak, Wan Sup;Oh, Young Kyun;Park, Keun Kyu
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.29 no.3
    • /
    • pp.444-454
    • /
    • 2016
  • This study was designed to examine the characteristics of sawdust and cocopeat bedding materials, including physicochemical properties (Exp. I) and on-farm trial (Exp. II). In Exp. I, the proportion of particle size was in the order of sawdust>cocopeat India>cocopeat Vietnam (p<0.05), and cocopeat contained higher proportion of small particles ($250{\mu}m$+below $250{\mu}m$) than sawdust, causing a dust production problem. Bulk density was cocopeat India>cocopeat Vietnam>sawdust (p<0.05), thus cocopeat treatments showed 4.4 times higher bedding cost than sawdust. The water absorption rates were 702.0% in cocopeat India, 678.3% in cocopeat Vietnam, and 444.0% in sawdust, showing cocopeat had approximately 1.5 times higher water absorption rate than sawdust. Moisture evaporation rates after 12 h of air blowing (2.00 m/s) were higher (p<0.05) in cocopeat Vietnam (80.4%) than sawdust (71.2%) and cocopeat India (72.8%). In vitro ammonia emissions were higher (p<0.05) in sawdust ($2.71mg/m^2/h$) than cocopeat India ($1.59mg/m^2/h$) and Vietnam ($1.22mg/m^2/h$), and total ammonia emissions were higher (p<0.05) in sawdust ($37.02mg/m^2$) than cocopeat India ($22.51mg/m^2$) and Vietnam ($13.60mg/m^2$). In Exp. II, an on-farm trial was conducted with 48 Hanwoo cattle in 16 pens using the same bedding materials as in Exp. I, with fan (blowing 2.00 m/s) and no fan treatments, and feed bunk side (FB) and water supply side (WS) within a pen (4.5 m, $width{\times}9.0m$, length). Beddings were replaced with fresh bedding materials when moisture concentrations were over 65%. No interactions among treatments were detected for moisture concentration and increment rates, and ammonia concentrations, but a significant effect was observed (p<0.01) for each of the treatments. Both concentrations and increment rate of moisture were higher (p<0.01) in the beddings without fan than with fan. Moisture concentrations and increment rate within a pen were also higher (p<0.01) in FB than WS. Thus, the whole no-fan-FB and sawdust-fan-FB were replaced with fresh bedding material between 4 to 5 experimental weeks. The ammonia concentrations and pH of beddings were not significantly different among treatments. Therefore, using cocopeat bedding with a blowing fan can extend twice the bedding utilization period, and WS within a pen showed twice the bedding-life compared to FB. Despite the outstanding characteristics of cocopeat compared with sawdust, using cocopeat as an alternative for sawdust bedding is not recommended for cattle management, considering it has 4.4 times higher bedding cost and a dust production problem.