• Title/Summary/Keyword: Dust cleaning

Search Result 115, Processing Time 0.021 seconds

A Feasibility Study of Using a Mini-dish Cluster for Solar Power Generation (소형 태양 반사경 클러스터를 이용한 태양열 발전에 대한 타당성 연구)

  • Oh, Seung-Jin;Lee, Jung-Sung;Hyun, Joon-Ho;Kim, Nam-Jin;Chun, Won-Gee
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.161-164
    • /
    • 2006
  • This paper introduces a preliminary work for the design of a mini-dish cluster system for power general ion. Each mini-dish (typically has a 20 to 30cm in diameter) is designed with a simple parabolic profile, concentrating sun light (after the glass glazing cover to avoid dust deposition on the reflector and facilitate cleaning) onto a centrally located small plane(or concave) mirror which is placed on the bottom side of the transparent glass cover. The mirror with a mini-dish concentrator is designed to focus beam radiation onto a focal point before it enters a bundle of optical fibers connected to a remote receiver for power generation different options are considered In designing a mini-dish concentrator to maximize its effectiveness for the collection and use of solar energy.

  • PDF

Performance Test of Domestic Glass Fabric by varying cleaning conditions in a Pulse-Jet Cleaned Fabric Filter (충격기류 탈진방식 여과포집진장치에서 탈진조건 변화에 따른 국산유리섬유여과포의 성능시험)

  • 박영옥;구철오;임정환;김영성;손재익
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.10 no.3
    • /
    • pp.183-190
    • /
    • 1994
  • Performance of domestic glass fabrics was tested in a Pulse- jet cleaned fabric filter under simulated coal combustion. Pulse Pressure were 2.5, 4.0kgf/$\textrm{cm}^2$ and pulse air nozzle diameter were 4.0, 6.0mm Pressure drop and penetration turned out to be low at small pulse air nozzle diameter and low pulse air pressure. Fractional penetration through the dust cake and fabric at face velocity of 1.7m/min was higher than that at face velocity of 1.0m/min. As a consequense, the performance of domestic glass fabrics was better with face velocity of less than 1.0m/min, pulse air pressure of 2.5 kgf/$\textrm{cm}^2$ and pusle air nozzle diameter of 4.0mm.

  • PDF

New Design of Cap Type Filter for Oil Mist Removal (미세 분무유 제거를 위한 신개념 특수필터 설계)

  • Kim, Hong-Gun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.20 no.1
    • /
    • pp.13-16
    • /
    • 2011
  • It is a tendency where the number of the restaurant is increasing recently with advancement of the food service industry. In comparison, Noxiousness fine MIST and the removal are passively done in about offensive odor which occurs meat products processing as emitting like that in the atmosphere. Because adherence lamination in the exhaustion line pipe has need of a periodic cleaning and change, it must discontinue the business of long time. In this paper, The technique development on fine MIST, dust of offensive odor and filtering which occur meat products processing prevents adherence/lamination of fine MIST in exhaustion line pipe. And the source prevents the environmental matter which is emitted in the atmosphere under maximizing boil offensive odor and the filtering effect of noxiousness MIST.

A study on the safety of the Environment Corrosion of Suspension Insulater of a Catenary Trolley Wire Systems (카테나리 전차선로 현수애자의 환경부식에 따른 안전성 연구)

  • Lee, Jae-Bong;So, Sun-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.864-874
    • /
    • 2007
  • Suspension insulator in Catenary Trolley Wire Systems must have two characteristics, electric insulation and mechanical endurance. Because suspension insulator is used in supporting and insulating position between power supply parts and earth conducted supporting parts. The insulator's electric characteristics can be influenced by surface pollution and damage from the environment such as humidity, dust, smoke, salt. etc. And, the insulating parts can be electrically short. These electrically damaged insulator can cause serious accidents that have far-reaching effect. So appropriate management basis of suspension insulator is needed. And we present appropriate cleaning and the changing period of suspension insulator on the basis of actual data.

  • PDF

A Feasibility Study of using Mini-dish Systems for Solar Power Generation (소형 태양 반사경 Cluster를 이용한 태양열 발전에 대한 타당성 연구)

  • Oh, Seung-Jin;Hyun, Joon-Ho;Chun, Won-Gee;Han, Hyun-Joo;Kim, Jeong-Tai
    • New & Renewable Energy
    • /
    • v.2 no.4 s.8
    • /
    • pp.39-45
    • /
    • 2006
  • This paper introduces a preliminary work for the design of a mini-dish cluster system for power generation. Each mini-dish [typically has a 20 to 30 cm in diameter] is designed with a simple parabolic profile concentrating sun light [after the glass glazing cover to avoid dust deposition on the reflector and facilitate cleaning] onto a centrally located small plane[or concave] mirror which is placed on the bottom side of a transparent glass cover. The mirror with a mini-dish concentrator is designed to focus beam radiation onto a focal point before it enters a bundle of optical fibers connected to a remote receiver for power generation. Different options are considered in designing a mini-dish concentrator to maximize its effectiveness for the collection and use of solar energy.

  • PDF

Study of Pressure and Flow in the Air-Cleaner of Commercial Vehicle (디젤엔진의 공기청정기내 압력 및 유동분포에 관한 연구)

  • 류명석;구영곤;김경훈;맹주성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.3
    • /
    • pp.47-53
    • /
    • 1997
  • The importance of intake system can not be overstressed in the recent heavy duty commercial vehicle design. The basic requirements of intake system are to have less flow resistance and better air cleaning performance which have direct effects on the performance and service life of engine. In order to improve the performance of engine intake system, the flow phenomena in the intake system should be fully understood. With readily availble CFD code, the numerical analysis becomes the more reliable tools for flow optimization in recent design work. In this research, flow field in the intake system was analyzed by STAR-CD, the 3-D computational fluid dynamics code. Especially, the flow inside of air cleaner was thoroughly analyzed. Pressure distribution and velocity profile in the air cleaner and intake duct was obtained. Having the dust seperated from incoming air at the expense of less pressure drop is the ultimate goal for the research.

  • PDF

The Performance Loss by the Soiling of Photovoltaic Modules (태양전지 모듈의 소일링에 의한 성능 저하)

  • Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korean Solar Energy Society
    • /
    • v.35 no.2
    • /
    • pp.63-71
    • /
    • 2015
  • Soiling is the accumulation of dirt on photovoltaic (PV) modules and can reduce the performance of the PV power plant depending on the site location. Nevertheless, the reason which can not be the great interest to researchers of PV reliability is the phenomenon of performance loss caused by external environmental factors, not the internal degradation of the PV module. In this paper, we provide the phenomenon, history, research overview and mitigation method in order to help understanding of the soiling.

Trace element Analysis and Source Assessment of Apartment Parking Lot Dust in Daegu, Korea (공동주택 주차장의 축적먼지 중 미량원소성분 분석과 오염원 평가)

  • Bae, Gun-Ho;Jung, Cheol-Su;Park, Kyu-Tae;Lee, Myoung-Sook;Shin, Dong-Chan;Kim, Yong-Hye;Yoon, Min-Hye;Han, Young-Jin;Choi, Hyuek;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.10
    • /
    • pp.756-766
    • /
    • 2011
  • In order to investigate the degree of apartment parking lot dust contamination, total 72 samples of parking lot dust (36 from ground parking lots and 36 from the underground parking lots) were collected in Daegu city from the end of March to the early June 2010. The dust samples were sieved below $100{\mu}m$, and analysed by ICP for 14 elements after an acid extraction. Results obtained from the source assessment of trace element using enrichment factor showed that Fe, K, Mg, Mn, Na and V were influenced by natural sources, while Cd, Cr, Cu, Ni, Pb and Zn were influenced by anthropogenic sources in both the ground parking lot and the underground parking lot. And results showed that Ca were influenced by natural sources in the ground parking lot, but influenced by anthropogenic sources in the underground parking lot. The measured values were remarkably higher in components from natural sources than in components from anthropogenic sources. Underground parking lot dust was more affected by anthropogenic sources and contaminated compared with the ground parking lot dust. Pollution index of heavy metals revealed that underground parking lot dust was 5.5 times more contaminated with heavy metal components than the ground parking lot dust. The results of correlation analysis among trace elements indicated that components in the ground parking lot were more correlated than those in the underground parking lot, and especially more correlated with natural sources-natural sources. Analysis for correlations between components and influencing factors in the underground parking lot showed that concentrations of heavy metals were higher with smaller number of parking spaces and no ventilation system, and older apartments in last paint and cleaning had relatively higher contents of heavy metals than those of recently painted and cleaned.

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF