• 제목/요약/키워드: Dust cleaning

검색결과 115건 처리시간 0.024초

공기정화용 소형 전기집진장치의 집진효율에 관한 연구 (A Study on Collection Efficiency of Compact and Small Size Air-Cleaning Electrostatic Precipitator)

  • Lee, S.H.;Yum, M.O.;Kang, K.O.
    • 한국정밀공학회지
    • /
    • 제14권1호
    • /
    • pp.84-89
    • /
    • 1997
  • Recentely, a compact and small size air-cleaning Electrostatic Precipitator(ESP) is needed to develop for air conditioning devices. From Deutsch formula for ESP efficiency, collection efficiency is affected not only the structure of collection section but also the charge rate of dust. In terms of collection area, the most useful type is a scroll type ESP. In this work, we investigated experimentally aptimum design factor of scroll type ESP by application of Taguchi method. And we developed the scroll type ESP by using optimal condition of control factor.

  • PDF

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

$CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구 (Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts)

  • 이은지;조남철;이종명;유재은
    • 보존과학회지
    • /
    • 제27권3호
    • /
    • pp.333-344
    • /
    • 2011
  • 철제유물의 보존처리 과정 중 표면 이물질 제거는 유물의 원형을 찾아주는 중요한 단계이다. 현재 표면 이물질 제거 시 가장 많이 사용하는 sand blaster (air brasive)의 경우, 분사되는 유리가루는 인체에 유해하고 환경오염을 유발하는 주요한 물질이다. 그러므로 이런 문제점을 보완하기 위해 타 산업분야에서 친환경세정장비로 많이 쓰이고 있는 $CO_2$ snow cleaning을 철제유물 표면 이물질 제거에 적용하여 비교·연구 하였다. 실험은 부식시험편과 철제유물에 sand blaster와 $CO_2$ snow cleaning을 적용하여 비교 분석하였다. 부식시험편의 경우, sand blaster와 $CO_2$ snow cleaning 방법 모두 이물질 제거 정도, 표면 거칠기, 색도 측정 결과가 유사하게 나타났으며, 특히 SEM을 통해 $CO_2$ snow cleaning을 적용한 부식시험편은 sand blaster에 비해 표면을 마모시키지 않는 것을 확인하였다. 또한 철제유물에 적용한 경우, $CO_2$ snow cleaning의 power nozzle은 sand blaster에 비해 표면을 마모시키지 않고 고른 표면을 유지하는 등 세정효과가 우수하게 나타났다. 그리고 X-ray촬영을 통해 이물질 제거 전과 후 금속 내부의 구조적 변화는 없음을 관찰하였다. 결론적으로 sand blaster와 $CO_2$ snow cleaning의 power nozzle은 이물질 제거 효과가 유사함을 확인할 수 있었다. 그러나 $CO_2$ snow cleaning의 power nozzle을 철제유물에 적용하여도 sand blaster와 유사한 효과는 얻을 수 있으나, 분사압력이 높을 경우 철제 유물이 손상될 우려가 있으므로 유물 내부 상태에 따라 적용여부를 판단해야 함을 본 실험을 통하여 알 수 있었다.

선형엑츄에이터를 이용한 실내 공기질 개선 시스템에 대한 연구 (A Study on Indoor Air-quality Improvement System Using Actuator)

  • 서도원;윤근영
    • 한국전자통신학회논문지
    • /
    • 제16권1호
    • /
    • pp.183-190
    • /
    • 2021
  • 본 논문은 실내 공기질 개선을 위한 스마트 공기청정 시스템 구현 및 구동에 관한 연구이다. 최근 다양한 환경적 요인으로 인해 실내 공기질 오염에 따른 문제가 심각해지고 있다. 본 연구에서는 이와 같은 실내 공기질 오염의 문제점을 개선하기 위해, IoT 센서를 활용한 스마트 공기청정 시스템을 구현하고자 한다. 특히 공기질 오염도를 실시간으로 측정하고, 오염도에 따라 서로 다른 공기 정화 경로를 가변시켜 줄 수 있는 시스템을 제안하였다. 이를 통해 효율적인 공기질 개선 및 필터의 수명 연장, 시스템 에너지 저감 등을 검토하였다. 또한 실내 공기질 개선 시스템에 대한 기능을 구현하기 위해 주요 부품을 선정하였고, 시제품을 제작하여 동작성을 확인하였다. 최종적으로 선형엑츄에이터를 활용한 실내 공기질 개선 시스템의 구현을 통해, 공기질 개선에 대한 효용성을 검토하였다.

지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발 (Development of an ionic wind dust collector towards coronavirus reduction in subway stations)

  • 신동호;김영훈;한방우
    • 한국입자에어로졸학회지
    • /
    • 제18권1호
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

Effectiveness of education for control of house dust mites and cockroaches in Seoul, Korea

  • JEONG Kyoung Yong;LEE In-Yong;LEE Jongweon;REE Han-Il;HONG Chein-Soo;YONG Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • 제44권1호
    • /
    • pp.73-79
    • /
    • 2006
  • We evaluated the efficacy of health education in reducing indoor arthropod allergens in Seoul. The mite control measures comprised the use of mite-proof mattress and pillow coverings, regular washing of potentially infested materials, maintenance of a low humidity, removal of carpets, and frequent vacuum cleaning. Cockroach control measures included trapping, application of insecticides, and protecting food. Of 201 homes enrolled in October 1999, 63 volunteers were included in a 2-year follow-up survey between April 2000 and January 2002. Before intervention, the density of mites/g of dust varied greatly; 27.1/g in children's bedding, 20/g in adult bedding, 7.2/g on the floors of children's bedrooms, 6.8/g in sofas, 5.9/g on the floors of adult's bedrooms, 3.9/g on living room floors, 3.7/g in carpets, and 1.9 mites/g on kitchen floors. The predominant mite species and house percentages infested were; Dermatophagoides farinae $93\%$, D. pteronyssinus $9\%$, and Tyrophagus putrescentiae $8\%$. Comparing 1999 and 2001 infestations, before and after 25 mo of education, mite abundance was reduced by $98\%$, from 23.7 to 0.57 mites/g of dust. In 1999, cockroaches were detected in $62\%$ homes: $36\%$ Blattella germanica and $35\%$ Periplaneta spp., including $9\%$ double infestations of B. germanica and P. americana. Following intervention, cockroach infestation rates decreased to $22\%$ of houses in 2000 and $23\%$ in 2001. We conclude that continuous and repetitive health education resulted in the effective control of domestic arthropods.

융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성 (Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector)

  • 박영옥;정주영
    • 한국입자에어로졸학회지
    • /
    • 제6권4호
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

청연군주묘(淸衍郡主墓) 출토복식(出土服飾) 중 직김(織金), 부김의(附金衣)의 보존처리 (Conservation Treatment of Jikgeum(Weave with Supplementary Golden Wefts) and Bugeum(Gold sticking) Textiles and Costumes Excavated from Tomb of Cheongyeongunju (a Princess))

  • 박승원;이윤경;유혜선
    • 박물관보존과학
    • /
    • 제9권
    • /
    • pp.67-83
    • /
    • 2008
  • 국립중앙박물관이 소장하고 있는 청연군주 출토복식(신수751 의류 일괄) 중 織金 및 金箔이 있는 복식의 보존 처리 과정을 소개하고자 한다. 금사 및 금박의 비파괴분석(X-선형광분석:XRF)을 실시한 다음 표면의 금(Au)이 열화가 진행되면서 분상화된 금층에 아교 2%용액을 도포하여 접착력을 강화하였다. 표면의 먼지와 오염물제거를 위해 진공흡입을 통한 건식세척과 분사식 습식세척을 병행하였고 손상부분을 보수하여 유물의 원형을 회복하였다.

세라믹캔들필터 집진 전후 Ash의 크기 및 분포에 관한 연구 (A study on Ash size and its distribution on cleaning of ceramic candle filter)

  • 정진도;이중범;김종영
    • 대한기계학회논문집B
    • /
    • 제20권5호
    • /
    • pp.1639-1648
    • /
    • 1996
  • Protection of gas turbine blade from its erosion and abrasion at high temperature and pressure is the first goal to cleanup the hot gas upstream for IGCC and PFBC. Ceramic filters represent an attractive technology for particle removal at high temperature and high pressure condition. They have demonstrated being a good system for improvement of thermal efficiency and reduction of effluent pollutants in advanced coal-based power systems such as IGCC and PFBC. Ceramic filter elements currently being developed were evaluated in the previous paper. In this paper, we measured the ash size and distribution on cleaning of ceramic candle filter. The results are as follows : in this experimental range, ceramic candle filter was shown to be fully adequate for the removal process of dust under high temperature and pressure. Also filtration efficiency of ceramic candle filter was higher than 98% compared with the regulation limit of particle size in gas turbine inlet.

고온 세라믹필터의 펄스젯 탈진 성능에 관한 연구 (A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter)

  • 김병렬;박승철;박병철;조현준;오형모;황태원;신상운
    • 방사성폐기물학회지
    • /
    • 제3권1호
    • /
    • pp.9-16
    • /
    • 2005
  • To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.

  • PDF