• Title/Summary/Keyword: Dust cleaning

Search Result 115, Processing Time 0.028 seconds

A Study on Collection Efficiency of Compact and Small Size Air-Cleaning Electrostatic Precipitator (공기정화용 소형 전기집진장치의 집진효율에 관한 연구)

  • Lee, S.H.;Yum, M.O.;Kang, K.O.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.1
    • /
    • pp.84-89
    • /
    • 1997
  • Recentely, a compact and small size air-cleaning Electrostatic Precipitator(ESP) is needed to develop for air conditioning devices. From Deutsch formula for ESP efficiency, collection efficiency is affected not only the structure of collection section but also the charge rate of dust. In terms of collection area, the most useful type is a scroll type ESP. In this work, we investigated experimentally aptimum design factor of scroll type ESP by application of Taguchi method. And we developed the scroll type ESP by using optimal condition of control factor.

  • PDF

Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries (산업용 필터백의 구조에 따른 여과성능 특성)

  • Jeon, Seong-Min;Hasolli, Naim;Lee, Kang-San;Lee, Jea-Rang;Kim, Kwang-Deuk;Park, Young-Ok
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.4
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

Application Study of $CO_2$ Snow Cleaning for Cleaning of Foreign Matter and Corrosion Products on Iron Artifacts ($CO_2$ Snow Cleaning 적용 철제유물 표면 이물질 제거 연구)

  • Lee, Eun-Ji;Cho, Nam-Chul;Lee, Jong-Myong;Yu, Jae-Eun
    • Journal of Conservation Science
    • /
    • v.27 no.3
    • /
    • pp.333-344
    • /
    • 2011
  • Cleaning of foreign matter and corrosion products on surface among conservation treatment of iron artifacts is an important part for looking up a original form. The sand blaster is the most popular equipment when it removes the foreign matter and corrosion products on iron artifacts surface. Current foreign matter and corrosion products equipment, which mostly uses, is sand blaster. Glass dust which sprayed from sand blaster is harmful and causing environmental pollution. In order to solve these problems, we investigated the $CO_2$ snow cleaning that use a eco-friendly equipment to apply for cleaning foreign matter and corrosion products on surface of iron artifacts. It examined by using sand blaster and $CO_2$ snow cleaning to aged steel coupon and iron artifacts. In case of aged steel coupon, the result showed that the sand blaster and $CO_2$ snow cleaning methods were similar to the degrees of cleaning foreign matter and corrosion products, through surface roughness, color measurement and SEM. $CO_2$ snow cleaning applied to aged steel coupons weren't worn out the surface in comparison with sand blaster by SEM. When applied to the iron artifacts, power nozzle of the $CO_2$ snow cleaning was an excellent cleaning effect that surface wern't worn out in comparison with sand blaster. And, it showed that internal structure change of metal was no found before and after cleaning by X-ray radiography. Consequently, we confirmed that cleaning of the sand blaster and power nozzle of $CO_2$ snow cleaning were similar to the effect. But, it's very careful to use this method because of high outlet pressure of power nozzle for applying to the iron artifacts. As a result of experiments, it could be found that the cleaning methods should be selected depending on internal state of the artifacts.

A Study on Indoor Air-quality Improvement System Using Actuator (선형엑츄에이터를 이용한 실내 공기질 개선 시스템에 대한 연구)

  • Seo, Do-Won;Yoon, Keun-Young
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.1
    • /
    • pp.183-190
    • /
    • 2021
  • This study is a study on the implementation and operation of smart air cleaning system to improve indoor air quality. Recently, the problem of indoor air quality is getting serious due to various environmental factors. In this study, to improve the problems of indoor air quality, we implement an air cleaning system using IoT sensor. In particular, we proposed a system that can measure air pollution in real time and change different air flow paths according to pollution level. Through this, we examined efficient air quality improvement, extension of filter life, and system energy reduction. In addition, the main functions of the indoor air quality improvement system were constructed and prototypes were manufactured to confirm the operability. Finally, the utility of fine dust resolution through the implementation of the indoor air quality improvement system was examined.

Development of an ionic wind dust collector towards coronavirus reduction in subway stations (지하철 역사 내 코로나 바이러스 저감을 위한 이온풍 집진기 개발)

  • Shin, Dongho;Kim, Younghun;Han, Bangwoo
    • Particle and aerosol research
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2022
  • Since 2019, the corona virus has been continuously affect human life. In particular, in the indoor space where people live, infection by airborne transmission of viruses is a problem. Among them, the spread in the subway, which is the main mode of transport for humans, can be serious. To solve this problem, our research team developed an ionic wind collector to collect and remove corona virus using an ionic wind collector and ozone. In order to apply the ionic wind collector to the subway, it must operate in two modes. Because large amounts of ozone are harmful to the human body. There is a mode that collects bio-aerosol from the air using ionic wind and a mode that inactivates viruses floating in the air by generating a large amount of ozone. As the applied voltage increased, the cleaning ability of the ionic wind collector increased, and the farther the distance between the discharge electrode and the ground plate, the higher the cleaning ability even at low current. In addition, clean air delivery rate (CADR) of an ionic wind collector was up to 5.5 m3/min. As a result of measuring the amount of ozone generated, it was confirmed that 50 ppb to 250 ppb was generated, and it was confirmed that ozone generation was controllable in the ionic wind dust collector.

Effectiveness of education for control of house dust mites and cockroaches in Seoul, Korea

  • JEONG Kyoung Yong;LEE In-Yong;LEE Jongweon;REE Han-Il;HONG Chein-Soo;YONG Tai-Soon
    • Parasites, Hosts and Diseases
    • /
    • v.44 no.1 s.137
    • /
    • pp.73-79
    • /
    • 2006
  • We evaluated the efficacy of health education in reducing indoor arthropod allergens in Seoul. The mite control measures comprised the use of mite-proof mattress and pillow coverings, regular washing of potentially infested materials, maintenance of a low humidity, removal of carpets, and frequent vacuum cleaning. Cockroach control measures included trapping, application of insecticides, and protecting food. Of 201 homes enrolled in October 1999, 63 volunteers were included in a 2-year follow-up survey between April 2000 and January 2002. Before intervention, the density of mites/g of dust varied greatly; 27.1/g in children's bedding, 20/g in adult bedding, 7.2/g on the floors of children's bedrooms, 6.8/g in sofas, 5.9/g on the floors of adult's bedrooms, 3.9/g on living room floors, 3.7/g in carpets, and 1.9 mites/g on kitchen floors. The predominant mite species and house percentages infested were; Dermatophagoides farinae $93\%$, D. pteronyssinus $9\%$, and Tyrophagus putrescentiae $8\%$. Comparing 1999 and 2001 infestations, before and after 25 mo of education, mite abundance was reduced by $98\%$, from 23.7 to 0.57 mites/g of dust. In 1999, cockroaches were detected in $62\%$ homes: $36\%$ Blattella germanica and $35\%$ Periplaneta spp., including $9\%$ double infestations of B. germanica and P. americana. Following intervention, cockroach infestation rates decreased to $22\%$ of houses in 2000 and $23\%$ in 2001. We conclude that continuous and repetitive health education resulted in the effective control of domestic arthropods.

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

Conservation Treatment of Jikgeum(Weave with Supplementary Golden Wefts) and Bugeum(Gold sticking) Textiles and Costumes Excavated from Tomb of Cheongyeongunju (a Princess) (청연군주묘(淸衍郡主墓) 출토복식(出土服飾) 중 직김(織金), 부김의(附金衣)의 보존처리)

  • Park, Seungwon;Lee, Yoonkyoung;Yu, Heisun
    • Conservation Science in Museum
    • /
    • v.9
    • /
    • pp.67-83
    • /
    • 2008
  • This study is process of conservation treatment for textiles and custumes containing Jikgeum(weave with supplementary golden wefts) and Bugeum(Gold sticking) among excavated ones(including all of Sinsu751) of Cheongyeongunju (a princess) collected by the National Museum of Korea. Adhesive strength was reinforced by coating 2% solution of glue on layer of gold disintegrated in the course of depletion of gold(Au) on the surface after conducting nondestructive test(X-ray fluorescent analysis) of flat gold strip and gold sticking. To remove dust on the surface and polluted materials, dry cleaning through vacuum suction and spray-type wet cleaning were conducted simultaneously and damaged part was restored to recover the relics to original state.

A study on Ash size and its distribution on cleaning of ceramic candle filter (세라믹캔들필터 집진 전후 Ash의 크기 및 분포에 관한 연구)

  • Jeong, Jin-Do;Lee, Jung-Beom;Kim, Jong-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.5
    • /
    • pp.1639-1648
    • /
    • 1996
  • Protection of gas turbine blade from its erosion and abrasion at high temperature and pressure is the first goal to cleanup the hot gas upstream for IGCC and PFBC. Ceramic filters represent an attractive technology for particle removal at high temperature and high pressure condition. They have demonstrated being a good system for improvement of thermal efficiency and reduction of effluent pollutants in advanced coal-based power systems such as IGCC and PFBC. Ceramic filter elements currently being developed were evaluated in the previous paper. In this paper, we measured the ash size and distribution on cleaning of ceramic candle filter. The results are as follows : in this experimental range, ceramic candle filter was shown to be fully adequate for the removal process of dust under high temperature and pressure. Also filtration efficiency of ceramic candle filter was higher than 98% compared with the regulation limit of particle size in gas turbine inlet.

A Study on the Performance of Pulse Jet Cleaning in High Temperature Filter (고온 세라믹필터의 펄스젯 탈진 성능에 관한 연구)

  • Kim Byong Ryol;Park Seung Chul;Park Byoung Chul;Cho Hynu Joon;Oh Hyoung Mo;Hwang Tae Won;Shin Sang Woon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.9-16
    • /
    • 2005
  • To evaluate parameters influencing on the dust removal of the High Temperature Filter(HTF) system, a computer simulation of fluid dynamics inside the system had been performed. The results showed that the optimum pulse jet periods were 50ms and 90ms for the 1000mm and 1500mm long filter elements respectively. Dust removal effect was very excellent under the pulse jet pressure of 3 bar. But the distance between the pulse jet nozzle and the venturi of a filter element had no meaningful effect on the performance with the variation from 5mm to 10mm. Compared to the dispersion mode of pulse jet, the collective mode of pulse jet flow was preferable in maintaining the pressure inside the system stable.

  • PDF