• Title/Summary/Keyword: Dust Analysis

Search Result 944, Processing Time 0.025 seconds

Evaluation of Ultrasonic Multiple Scattering Method to Improve the Accuracy of Fine Dust Measurement (비산먼지 측정 정확도 개선을 위한 시뮬레이션 초음파 다중 산란 알고리즘 검증)

  • Woo, Ukyong;Choi, Hajin
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.6
    • /
    • pp.119-128
    • /
    • 2020
  • An ultrasonic multiple scattering simulation using cross-section of fine dust particles were proposed. These days, along with awareness of air pollution, social interest in fine dust is increasing. In the construction field, awareness of fine dust is increasing, and research on preparing various countermeasures is underway. The light scattering method fine dust meter currently in use is affected by environmental factors such as relative humidity, and reliability problems in terms of accuracy are continuously reported. However, the transmission of ultrasonic waves can directly reflect the physical change of the medium based on the mechanical wave. Using these advantages of ultrasonic waves, fine dust measurement simulation was performed using the scattering cross section and ultrasonic multiple scattering theory. The shape data of the fine dust particles were collected using a SEM (Scanning Electron Microscope), and a cross-section according to the fine dust particles was derived through numerical analysis. As a result of signal processing, the error for the number density corresponding to each cross-section is minimum 19, maximum 3455.

Evaluation of the Location Efficiency of Fine Dust Shelters Considering Vulnerable Population in Seoul (취약계층을 고려한 미세먼지 쉼터 입지 효율성 평가)

  • Lim, Jae Kwon;Lee, Hye Kyung
    • Journal of KIBIM
    • /
    • v.12 no.4
    • /
    • pp.104-115
    • /
    • 2022
  • Fine Dust in Korea has been classified as a social disaster since 2019 due to continuous increase in concentration of Particulate Matter 10(PM 10) and PM 2.5. The fine dust issue has negative physical and mental impacts, especially on vulnerable population including children and the elderly. Seoul metropolitan government have installed fine dust shelters since 2019. However, there is a lack of research that evaluates spatiotemporal distribution of these facilities. Therefore, the first aim of this study is to find the relationship between PM levels and dust scattering construction sites, or air pollutant emission sites through in depth spatial analyses. The second purpose is to analyze the spatial distribution of PM shelters in Seoul, and to evaluate the location efficiency of them. Kernel density, krigging, and network analyses were conducted, and floating population was considered instead of census data for this research. The reults of network analysis based on the road system showed that Yangcheon-gu, Songpa-gu, Seongbuk-gu, and Dobong-gu were found to need additional fine dust shelters. Also, the results from analyzing the floating population that includes children and the elderly showed that Songpa-gu, Seodaemun-gu, Gangdong-gu, Seocho-gu, and Dongdaemun-gu need more placements of find dust shelters. The results of this study are expected to provide implications for urban planners to enhance find dust shelter placement in urban areas, and vulnerable population issues would be considered in many ways.

Differences in fine dust emissions based on bedding type and quantity in horse stables

  • Ji Hyun Yoo;Jong An Lee;Jae Young Choi;Sang Min Shin;Hyeon Ah Kim;Mi Young Won;Yong Jun Kang;Hee Chung Ji;In Cheol Cho;Jin Hyoung Kim
    • Korean Journal of Agricultural Science
    • /
    • v.50 no.4
    • /
    • pp.917-925
    • /
    • 2023
  • Efforts for developing the domestic horse industry in South Korea are evident through the various national policies. Proper management of stables for ensuring the health of horses is essential to sustain the growing equine industry. This study aimed to measure the fine dust emissions in stables based on the type and quantity of bedding used for horses, for establishing guidelines pertaining to bedding use in stables. The stables accommodated 12 horses. Sawdust, wood shavings, wood pellet, and straw were chosen as treatments. Three different quantities (approximately 3, 6, and 9 cm in height) were applied for each type. Fine dust measurements were carried out at three time points, with each measuring period lasting for approximately three weeks. Measurements included PM2.5 and PM10 fine dust levels. The initial analysis revealed that, sawdust with 9 cm bedding had the highest dust levels; approximately 54.6 ㎍/m3, for PM2.5 and 95.3 ㎍/m3, for PM10. Sawdust bedding at the highest quantity (9 cm) exhibited significantly higher initial fine dust emissions. These findings suggest that bedding materials with smaller particle size, such as sawdust and wood shavings, tend to produce finer dust. Initially, the fine dust emissions decreased in all bedding types and quantities, possibly due to the increased moisture content of bedding owing to horse manure production. However, emissions increased subsequently due to ammonia production.

Nonlinear Stress Analysis of Dust Covers for Ball Joint of Automotive Steering System (자동차 조향장치의 볼 조인트 더스트 커버의 비선형 응력해석)

  • Kim, Ji Ho;Lee, Boo Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.10
    • /
    • pp.1297-1303
    • /
    • 2013
  • A nonlinear finite element analysis is performed to evaluate the sealing capability and stress of dust covers for the ball joint of an automotive steering system. The analysis is performed for two types of dust covers: wrinkle type and pot type. The assembly condition and operation condition are analyzed, and the maximum stress and contact normal stress at the ribs are evaluated. It is confirmed that the sealing capability of both types is fairly good, but the wrinkle type is better than the pot type in terms of the maximum stress.

Dust collector strainer and carbon filter pressure permeation analysis (흡연집진기 내 스트레이너 및 카본필터 압력투과 해석)

  • Lee, Chi-Woo
    • Journal of Power System Engineering
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 2015
  • Dust collector is one of the most widely used equipment among the method of separating particles, it filters exhaust gas having various kinds of dusts through several filters installed on parallel. This research investigated the moving characteristic of Honeycomb-type carbon filter in pressure drop of smoking collector's ventilation system. It also compared pressure transmission coefficient through pressure drop according to flow velocity change.

Non-destruction and Neutralization Properties of Mortar Mixed with Non-active Hwangto and Stone Dust (비활성 황토와 석분을 혼입한 모르타르의 비파괴 및 중성화 특성)

  • 성찬용;윤준노
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.3
    • /
    • pp.59-64
    • /
    • 2003
  • Hwangto would be an environment-friendly material that can be readily used. The purpose of this study is to obtain the absorption ratio, ultrasonic pulse velocity and neutralization of the mortar with non-active Hwangto and stone dust. The absorption ratio and neutralization depth are increased with increase of non-active Hwangto. But, the ultrasonic pulse velocity is decreased with increase of non-active Hwangto. In results of SEM analysis, the crystals are increased with increase of non-active Hwangto.

Analysis of Quartz Contents by XRD and FTIR in Respirable Dust from Various Manufacturing Industries Part I - Foundry (제조업체에서 발생하는 호흡성분진중 XRD와 FTIR를 이용한 결정형 유리규산 농도의 비교분석 제 1부 - 주물사업장)

  • Kim, Hyunwook;Roh, Young Man;Phee, Young Gyu;Won, Jeoung IL;Kim, Yong Woo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.50-66
    • /
    • 1998
  • This study was conducted to estimate crystalline silica contents in airborne respirable dust from various manufacturing industries and to compare analytical performance of two methods of quantifying crystalline silica, X-ray diffraction(XRD) and Fourie transform infrared spectroscopy (FTIR). For this study, various manufacturing industries with a history of having pneumoconiosis cases and also known to generate dusts containing crystalline silica were investigated. These industries include: foundry, brick, potteries, concrete, and abrasive material, etc. Both personal and area respirable dust samples were collected using 10 mm, Dorr-Oliver nylon cyclone equipped with 37mm, $5{\mu}m$ pore size, polyvinylchloride (PVC) filters as collection media. In addition, total dust samples were collected side-by-side to the respirable samples. All samples were weighed before and after sampling and were pretreated according to the NIOSH sampling and analytical methods 0500, 7500, and 7602 for dust collection and quartz analysis. In addition, bulk samples were collected and analyzed by X-ray fluorescence (XRF) for minerals. In this article, only the results obtained from foundry are reported. The results from various other industries will be published in future articles. The respirable dust concentrations from personal samples by cyclone were $0.46-1.06mg/m^3$ and those from area samples were $0.34-0.73mg/m^3$. Dust concentrations of personal samples were significantly higher than those of area samples. The highest dust concentration was obtained from the personal samples of the finishing operation. Total dust concentration ranged $1.24-3.40mg/m^3$. The mean quartz contents estimated by FTIR and XRD in the personal respirable dust samples were 5.12% and 4.41%, respectively, without significant difference between them. For quartz analyses, the two techniques were highly correlated with $r^2$ ranged 0.803-0.920. But the results by FTIR were mostly higher than those by XRD. In addition, cristobalite was not detected by FTIR. Significant correlations between contents of crystalline silica and such minerals as $Al_2O_3$, CaO, $TiO_2$, and $K_2O$ suggest possible interferences from these minerals.

  • PDF

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

A Study on the Reliability Analysis for Smoke Detector using Dust (분진을 이용한 연기감지기 신뢰성 분석에 관한 연구)

  • Hong, Sung Ho;Choi, Moon Soo;Lee, Young Man
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.6
    • /
    • pp.11-16
    • /
    • 2013
  • This paper presents a study on the analyzing reliability of smoke fire detector using accelerated life test. In general, the smoke fire detector is broken by dust which flow in smoke detection chamber. In order to conduct accelerated life test of smoke fire detector dust is set accelerated factor in this paper. The dust is fly-ash which is test particle 5th regulated by KS A 0090. The dust accelerated level is 60 g, 180 g and 360 g and failure time is measured by smoke sensitivity testing. It is considered to failure of detector if detector don't operate within 30 secconds when subjected to an air stream having a velocity of 20 cm/s~40 cm/s containing smoke with a concentration of 15% of rate of light-response of 1 m. The goodness of fit test and mean life prediction conduct using the failure time. The result show that life distribution fits the weibull distribution for failure time data and the mean lifes calculate 22.5 year in domestic product and 14.7 years in overseas product applied dust stress only.

Strategic Vitalization Method of AMP Installation through SWOT/AHP Analysis (SWOT/AHP 분석을 통한 전략적 AMP 설치 활성화 방안)

  • Kim, In-Ho;Lee, Kang-Won
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.4
    • /
    • pp.49-60
    • /
    • 2019
  • Recently the concentration of fine dust and ultra fine dust becomes so bad, which seriously threatens the health and even the life of people. So, government started to investigate several ways to reduce the amount of fine dust and ultra fine dust. From a few years ago it has been known that ships anchored at port emit a lot of pollution and seriously affect air quality of neighboring cities. To reduce the pollution emitted by ship AMP (Alternative Maritime Power Supply) has been proposed, which uses the electricity instead of bunker C oil or diesel. Many developed countries already installed AMP to improve air quality in port area. Korea is in the stage of planning to install AMP at port. However, there are many complicated problems to be handled before AMP installation. Due to huge initial cost and long period of construction ship owner and habour operating company are reluctant to AMP installation. And there are serious technological difficulties in constructing AMP in existing harbour. Lack of AMP core technology and operational difficulties of AMP are also big challenges to be conquered. In this study SWOT/AHP method is used to find strategic and efficient ways to handle above complicated challenges and then to vitalize the AMP installation.