• Title/Summary/Keyword: Duration reduction

Search Result 708, Processing Time 0.03 seconds

Applicability of Stabilization with Iron Oxides for Arsenic-Contaminated Soil at the Forest Area near the Former Janghang Smelter Site ((구)장항제련소 주변 송림산림욕장 지역 비소 오염토양의 철산화물을 이용한 비소 안정화 공법 적용 가능성 평가)

  • Yang, Kyung;Kim, Byung Chul;Yu, Gihyeon;Nam, Kyoungphile
    • Journal of Soil and Groundwater Environment
    • /
    • v.21 no.6
    • /
    • pp.14-21
    • /
    • 2016
  • This study evaluated the applicability of stabilization of arsenic (As)-contaminated soil with iron (Fe) oxides at the former Janghang smelter site. Three Fe oxides (magnetite, goethite, and hematite) were tested as stabilizing agents to one soil sample collected from the study site. Amendment of 5% of magnetite, goethite, or hematite for one week showed the 64, 58, and 36% of reduction of the SBRC (Solubility/Bioavailability Research Consortium)-extractable (bioaccessible) As, respectively. Duration of stabilization more than one week did not show an additional reduction in SBRC-extractable As. Amendment of 5% of magnetite, which showed the highest As stabilization efficiency, was applied to 24 soil samples collected from the same site for one week, and 72% of reduction in the bioaccessible As was observed. The potential carcinogenic human health risk at the study site caused by As was $1.7{\times}10^{-5}$, which could be reduced to $8.1{\times}10^{-6}$ by the amendment of 5% magnetite for one week.

Calculation of the Areal Reduction Factor of Hancheon River Basin based on Considering the Rainfall Characteristics in Jeju Island (제주도의 강우특성을 고려한 한천유역의 면적감소계수 산정연구)

  • Kang, Myung-Soo;Yang, Sung-Kee;Kim, Young-seok;Kang, Bo-Seong;Yang, Se-Chang
    • Journal of Environmental Science International
    • /
    • v.26 no.12
    • /
    • pp.1389-1397
    • /
    • 2017
  • In this study, we calculated the fixed-type Areal Reduction Factor (ARF) of the Hancheon River basin in Jeju Island, and compared the calculated ARF and the ARF of the four major river basins suggested by the Ministry of Land, Infrastructure and Transport. As a result, the maximum fluctuation ratios of ARF for the four major river basins calculated using area, frequency, and initial duration time were significant: 7.61% for the Hangang River basin; 12.69% for the Nakdonggang River basin; 8.09% for the Kumgang River basin; and 17.98% for the Yeongsangang River basin. In addition, the differences between the maximum and minimum value of ARF for the Hancheon River basin based on 48 hours was 2.13%, and it was smaller than the one for the four major river basins: 8.92% for the Hangang River basin; 11.41% for the Nakdonggang River basin; 8.87% for the Kumgang River basin; and 17.17% for the Yeongsangang River basin. The Yeongsangang River basin had the highest difference.

MIXING CONDITIONS WITH SPRAY-JET INTERACTION FOR EFFECTIVE SOOT REDUCTION IN DIESEL COMBUSTION

  • Chikahisa, Takemi;Hishinuma, Yukio;Ushida, Hirohisa
    • International Journal of Automotive Technology
    • /
    • v.3 no.1
    • /
    • pp.17-26
    • /
    • 2002
  • The authors have reported significant reductions in particulate emissions of diesel engines by generating strong turbulence during the combustion process. This study aims to identify optimum conditions of turbulent mixing for effective soot reduction during combustion. The experiments were conducted with a constant volume combustion vessel equipped with abet-generating cell, in which a small amount of fuel is injected during the combustion of the main spray. The jet of burned gas from the cell impinges the main flame, causing changes In the mixing of fuel and air. Observation was made for a variety combinations of distances between spray nozzle and Jet orifice at different directions of impingement. It Is shown that compared with the case without Jet flame soot decreases when the jet impinges. When the jet is very close to the flame, it penetrates the soot cloud and causes little mixing. There were no apparent differences in the combustion duration when the direction of impingement was varied, although the mechanisms of soot reduction seemed different. An analysis of local turbulent flews with PIV (Particle image Velocimetry) showed the relationship between the scale of the turbulence and the size of the soot cloud.

The effect of decompression as treatment of the cysts in the jaws: retrospective analysis

  • Lee, Sun-Tae;Kim, Su-Gwan;Moon, Seong-Young;Oh, Ji-Su;You, Jae-Seek;Kim, Jae-Sung
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.2
    • /
    • pp.83-87
    • /
    • 2017
  • Objectives: The purpose of this study is to evaluate the treatment efficacy of enucleation after decompression. Materials and Methods: A total of 17 patients with cystic lesion of the jaw were treated with decompression followed by enucleation. Pre- and post-decompression panoramic radiographs were analyzed. Results: The mean percentage of reduction after decompression was 64%. The reaction was graded as good (>80%) in five patients (29.4%), moderate (50%-80%) in nine patients (52.9%), and poor (<50%) in three patients (17.6%). The reduction rate of larger cystic lesions was faster than that of smaller lesions. However, the reduction rate was not affected by age. The duration of follow-up ranged from one to eight years. There were no complications, and one case recurred. Conclusion: Decompression is an effective method for the initial treatment of jaw cysts.

Flexural performance of fire damaged and rehabilitated two span reinforced concrete slabs and beams

  • Yu, Jiang-Tao;Liu, Yuan;Lu, Zhou-Dao;Xiang, Kai
    • Structural Engineering and Mechanics
    • /
    • v.42 no.6
    • /
    • pp.799-813
    • /
    • 2012
  • Five two-span reinforced concrete (RC) slabs and seven two-span RC beams were tested under the ISO 834 standard fire with different durations. CFRP strengthening was then applied to some of the specimens after the damaged concrete was removed from the specimens and replaced with polymer mortar. All the specimens were loaded to failure to investigate the influence of fire-damage and the effectiveness of strengthening methods. Test results indicated that the flexural capacities of specimens decrease with the fire duration increases. Moreover, fire exposure had more significant effect on the flexural rigidity than on the bearing capacity of the specimens. After rehabilitation, the bearing capacities of specimens reached or even exceeded that of the reference RC specimen, and the strengthening methods seemed to have limited effect on flexural rigidity recovery. From the analysis of moment redistribution of tested beams, elevated temperature is found having different impacts on sagging moment region and hogging moment region. The damage of RC continuous member is definitely a comprehensive response of different regions.

An Experimental Study on the Propagation Characteristics and Reduction of Impulse Noises from a High Voltage COS Fuse (고전압 COS 퓨즈로부터 방사된 충격성 소음의 전파특성과 저감에 관한 실험적 연구)

  • Song, Hwa-Young;Ju, Kyung-Min;Lee, Dong-Hoon;Kang, Rae-Goog;Jung, Nak-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.71-74
    • /
    • 2005
  • This experimental study describes the propagation characteristics and reduction of impulse noises emitted from a high voltage COS(Cut Out Switch) fuse of a transformer. When a high voltage COS fuse becomes a short circuit by the over current. The peak sound Pressure above 150dB(A) is generated. In this study, an impulse noise generator is designed for generating the impulse noises similar to the noise level of COS fuse, which is utilized to test the noise reduction of a reactive silencer. The reactive silencers have been tested for 10 different types with each different porosity, hole diameter and length. From the experimental results, it is found that the reactive silencer has an excellent performance to greatly suppress the impulse noise and that its performance is closely connected with the porosity and hole diameter.

  • PDF

Evaluation on Reducing Peak Cooling Load Based on Dynamic Load Model of Building Perimeter Zones (건물의 외주부 존에 대한 동적 부하모델 이용 피크냉방부하 저감효과 분석)

  • Lee, Kyoung-Ho;Brau, James E.
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.1-8
    • /
    • 2011
  • In this paper, inverse building modeling was applied to building perimeter zones which have different window orientation. Two test zones of east-facing and west-facing zones in ERS(Energy Resource Station) building, which is representative of small commercial building, was used to test performance of cooling load calculation and peak cooling load reduction. The dynamic thermal load model for the east and west zone was validated using measured data for the zones and then it was used to investigate the effect of peak cooling load reduction by adjustment of indoor cooling temperature set points during on-peak time period. For the east zone, the peak load can be reduced to about 60% of the peak load for conventional control even without any precooling. For the west zone, PLR is nearly independent of the start of the on-peak period until a start time of 1pm. Furthermore, PLR has a small dependence on the precooling duration. Without any precooling, the peak cooling load can be reduced to about 35% of the peak load associated with conventional control.

Reduction of the cetrorelix dose in a multiple-dose antagonist protocol and its impact on pregnancy rate and affordability: A randomized controlled multicenter study

  • Dawood, Ayman S.;Algergawy, Adel;Elhalwagy, Ahmed
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.4
    • /
    • pp.232-238
    • /
    • 2017
  • Objective: To determine whether reducing the cetrorelix dose in the antagonist protocol to 0.125 mg had any deleterious effects on follicular development, the number and quality of retrieved oocytes, or the number of embryos, and to characterize its effects on the affordability of assisted reproductive technology. Methods: This randomized controlled study was conducted at the Fertility Unit of Tanta Educational Hospital of Tanta University, the Egyptian Consultants' Fertility Center, and the Qurrat Aien Fertility Center, from January 1 to June 30, 2017. Patients' demographic data, stimulation protocol, costs, pregnancy rate, and complications were recorded. Patients were randomly allocated into two groups: group I (n = 61) received 0.125 mg of cetrorelix (the study group), and group II (n = 62) received 0.25 mg of cetrorelix (the control group). Results: The demographic data were comparable regarding age, parity, duration of infertility, and body mass index. The dose of recombinant follicle-stimulating hormone units required was $2,350.43{\pm}150.76$ IU in group I and $2,366.25{\pm}140.34$ IU in group II, which was not a significant difference (p= 0.548). The duration of stimulation, number of retrieved oocytes, and number of developed embryos were not significantly different between the groups. The clinical and ongoing pregnancy rates likewise did not significantly differ. The cost of intracytoplasmic sperm injection per cycle was significantly lower in group I than in group II (US $ $494.66{\pm}4.079$ vs. US $ $649.677{\pm}43.637$). Conclusion: Reduction of the cetrorelix dose in the antagonist protocol was not associated with any significant difference either in the number of oocytes retrieved or in the pregnancy rate. Moreover, it was more economically feasible for patients in a low-resource country.

Fracture and Dislocation of Lisfranc Joint: Treatment with Screw and Kirschner Wire (리스프랑 관절 골절 및 탈구: 나사와 Kirschner 강선을 이용한 치료)

  • Ha, Dong-Jun;Kim, Jeon-Gyo;Gwak, Heui-Chul;Jang, Yue-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.4
    • /
    • pp.181-187
    • /
    • 2015
  • Purpose: The purpose of this study is to retrospectively analyze the clinical results of screws and Kirschner wire (K-wire) fixation in patients with fracture dislocation of Lisfranc joint and the consequence of screw breakage. Materials and Methods: Sixty patients underwent Lisfranc joint open reduction and removal of internal fixators from January 2007 to December 2011. Forty-nine cases (81.7%) underwent operations with screw alone, and 11 cases (18.3%) underwent operations with both screws and K-wires. Type of internal fixators, duration of internal fixator removal, breakage of internal fixators and satisfaction with reduction were investigated. Additionally, American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scales were analyzed. Results: The internal fixator was broken in 5 cases (8.3%). The average duration of instrument removal was 154 days in the non-broken screw group and 268.6 days in the broken screw group (p<0.05). The average AOFAS midfoot scale was 77.4 in the non-broken screw group and 74.2 in the broken screw group. The most commonly damaged portion was the first tarsometatarsal (Lisfranc) joint. Conclusion: Treatment with screws and K-wires was effective in patients with fracture dislocation of Lisfranc joint. The appropriate time for screw removal should be considered.

Optimum Conditions for Tobacco Seed Priming by PEG 6000

  • Tai-Gi, Min;Byung-Moon, Seo
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.3
    • /
    • pp.263-266
    • /
    • 1999
  • Tobacco (Nicotiana tabacum L. ‘KF109’) seeds were primed in polyethylene glycol 6000 (PEG 6000) solutions to determine a) what osmotic potential of the solution would be optimal for priming, i.e., critical potential level for preventing germination, and b) what temperature and duration would be the most effective in priming. The germination was completely prevented below -0.8 MPa of PEG 6000, that indicates a optimum water potential for seed priming. Seeds were primed for 0, 1, 2, 3, 5, 10 and 15 days at 15, 20 and $25^{\circ}C$, respectively, under the-0.8 MPa PEG 6000 solution to find out the most effective temperature and duration for priming. The effectiveness of priming, particularly in germination speed, was observed more distinctly when the primed seeds were germinated at 15$^{\circ}C$ than 2 5$^{\circ}C$. The greatest reduction of the time to 50% germination (T/sob 50/) was when the seeds were primed at $25^{\circ}C$. The reduction rate of the $T_{50}$ was rapid when primed from 1 day to 8 days and then slowed down in the seeds primed for longer than 8 days. The time from 10 to 90% germination ( $T_{10-90}$ increased in the primed seeds for longer than 8 days which showed the reversed effect of synchronous germination. However, $T_{50}$ was reduced continuously in the seeds even primed over 8 days. Thus, the optimum condition for tobacco seeds priming with PEG 6000 solution was -0.8 MPa in osmotic potential of the solution at $25^{\circ}C$ for 8 days.ays.

  • PDF